• Title/Summary/Keyword: module performance

Search Result 2,736, Processing Time 0.031 seconds

Experimental Study of Standalone Cooling and Heating System using Thermoelectric Element for Vehicles (열전소자를 이용한 차량용 독립 냉난방시스템에 대한 실험적 연구)

  • Lee, Dae-Woong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.8
    • /
    • pp.375-380
    • /
    • 2014
  • The purpose of this paper is to investigate the cooling and heating performance of a standalone-type thermoelectric system equipped with a thermoelectric module. The system consists of a blower and two thermoelectric modules with a fin, which is soldered onto both sides of the thermoelectric module and a courtesy light. The thermoelectric system experiment is conducted with the intake voltage to find the optimum cooling and heating performance of each. The results showed that the cooling capacity and coefficient of performance (COP) were 22 W and 0.31, and the heating capacity and COP were 147 W and 1.1, respectively. In the vehicle cooling and heating performance test in a climate wind tunnel, the results showed that the standalone thermoelectric system's cooling performance was slightly better than the base system; and the heating performance of the standalone thermoelectric system was $54.1^{\circ}C$ and the COP was 1.3, compared to the base system.

Fabrication of 50GHz internal wavelength locker module for DWDM applications (DWDM 광통신용 50GHz 내장형 파장안정화 모듈 제작)

  • Choi, Kwang-Seung;Park, Heung-Woo;Park, Jun-Hee;Choi, Byung-Seok;Lee, Jong-Hyun;Yun, Ho-Kyung;Eom, Yong-Sung;Moon, Jong-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.198-202
    • /
    • 2003
  • Tunable laser diode module with 50GHz-spacing internal wavelength locker was developed. Angle tilting dependency on FSR and peak wavelength shift and the proper initial tilting angle was calculated. By tilting the etalon, the response of the internal wavelength locker module was tuned. As a result, the fabricated internal wavelength locker module showed good performance over 62 channels.

  • PDF

An Experimental Study of Short Stack on the Performance of the Proton Exchange Membrane Fuel Cell for the Residential Power generation (소형 모듈 스택을 이용한 가정용 연료전지 성능의 실험적 고찰)

  • Choi, Won-Seok;Kim, Yong-Mo;Yu, Sang-Seok;Lee, Young-Duk;Hong, Dong-Jin;Ahn, Kook-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.21-24
    • /
    • 2008
  • Proton Exchange Membrane Fuel Cell (PEMFC) is an attractive candidate for residential power generator due to fast start-up and stop, high efficiency, low emission, and high power density. In this study, we employ short module stack to understand the performance of the unit cell of the stack in terms of operating temperatures. To simulate the practical fuel cell stack of residential power generator, the structure and active area of the short module stack is kept the same as that of the practical fuel cell. The results shows that the electric potential of short module stack is different from the number of cells times the potential of unit cell because of cell-to-cell variation.

  • PDF

Optimum Design of Packaging Container for Bulk Materials(II)-Computer Program Development (벌크화물용 포장용기의 최적 설계(II)-프로그램 개발)

  • Park, Jong-Min;Kwon, Soon-Hong;Chung, Sung-Won
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.6 no.1
    • /
    • pp.12-18
    • /
    • 2000
  • If optimum design technique is applied in the design of packaging container for bulk materials, merits on the side of not only economic and compression performance but distribution efficiency are expected. In this study, on the ground of the optimum models for required board area and compression strength performance, optimum design program having faculties of outward and inward optimum design and information design was developed. This program was composed of input module, output module, database and management module, and calculation module. Though the packaging specifications ars same, requied board area, board composition and cost of container were greatly different according to exterior packaging conditions. Also, about 12% in weight of container was lighter, and about $13{\sim}17%$ in cost of container was reduced when the program was applied for 2 kinds of bulk materials.

  • PDF

Phase and Amplitude Drift Research of Millimeter Wave Band Local Oscillator System

  • Lee, Chang-Hoon;Je, Do-Heung;Kim, Kwang-Dong;Sohn, Bong-Won
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.2
    • /
    • pp.145-152
    • /
    • 2010
  • In this paper, we developed a local oscillator (LO) system of millimeter wave band receiver for radio astronomy observation. We measured the phase and amplitude drift stability of this LO system. The voltage control oscillator (VCO) of this LO system use the 3 mm band Gunn oscillator. We developed the digital phase locked loop (DPLL) module for the LO PLL function that can be computer-controlled. To verify the performance, we measured the output frequency/power and the phase/amplitude drift stability of the developed module and the commercial PLL module, respectively. We show the good performance of the LO system based on the developed PLL module from the measured data analysis. The test results and discussion will be useful tutorial reference to design the LO system for very long baseline interferometry (VLBI) receiver and single dish radio astronomy receiver at the 3 mm frequency band.

A Functional Design of Programmable Logic Controller Based on Parallel Architecture (병렬 구조에 의한 가변 논리제어장치의 기능적 설계)

  • 이정훈;신현식
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.8
    • /
    • pp.836-844
    • /
    • 1991
  • PLC(programmable logic controller) system is widely used for the control of factory. PLC system receives ladder diagram which is drawn by the user to implement hardware logic, converts the ladder diagram into sequence program which is executable in the PLC system, and executes the sequence program indefinitely unless user breaks. The sequence program processes the data of on/off signal, and endures 1 scan delay and missing of pulse-type signal shorter than a scan time. So, data dependency doesn't exist. By applying theis characteristics to multiprocessor architecture, we design parellel PLC functionally and evaluate performance upgrade. Parallel PLC consists of central processing module, N general processing unit, and a shared memory by master-slave type. Each module executes allocated sequence program by the control of central processing module. We can expect performance upgrade by parallel processing, and reliability by relocation of sequence program when error occurs in processing module.

  • PDF

Development of the intelligent building control system simulator for the performance analysis (인텔리젼트 빌딩 제어 시스템의 성능해석을 위한 시뮬레이터 개발)

  • 배중원;임동진;송규동
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.624-627
    • /
    • 1996
  • To provide pleasant building environment and the ease of maintenance and facility management, many new office buildings are being built as intelligent buildings. Building control systems which are employed in intelligent buildings require advanced types of controllers and varieties of control schemes. Designing and installation of these types of advanced building control systems take a lot of effort and also they are costly. In order to design these systems, it is necessary for the designers to have means to analyze and estimate the performance of control systems. The simulator which is presented in this paper is composed of three parts, HVAC simulation module, elevator simulation module, and evacuation modeling module for the outbreak of fire or similar disasters. In this paper, the functions and modelling method for each module are explained and simulation results are presented.

  • PDF

Development of Performance and Evaluation Program for Optical Filters (광필터 성능평가 프로그램 개발)

  • Choi D.-S.;Park H. S;Seo Y. H;Jae T.-J.;Whang K.-H.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.9 no.3
    • /
    • pp.220-225
    • /
    • 2004
  • This paper presents a program for the automatic alignment of optical axes and evaluation of the optical filter performance which is a key technologies for the production of optical module. Recently the production of optical filter module mostly depends upon handwork or semi-automation. Moreover, they have used an expensive spectrum analyzer. In this work, we have developed an automatic alignment and evaluation program of optical filter module using photo detector and developed program for automation and cost reduction of the production of optical titter module.

Demonstration Study of 10kW Poly Metal Panel integrated PV Module (10kW급 지붕재용 태양전지모듈 실증연구)

  • Yi, So-Mi;Noh, Ji-Hee;Joo, Man-Sic
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.246-249
    • /
    • 2007
  • The application of photovoltaics into building as integrated building components has been paid more attention worldwide. Photovoltaics or solar electric modules are sol id state devices, directly converting solar radiation into electricity; the process does not require fuel and any moving parts, and produce no pollutants. And the prefab building method is very effective because the pre- manufactured building components is simply assembled to making up buildings in the construction fields especially the sandwich panel. So, this paper describes a design and performance test of the 10kW poly metal pv module(pmpp) system. It is concluded that the prediction of BIPV system's performance should be based on the more accurate PV module installation.

  • PDF

BIM-Based Integrated Module for Apartment Environmental Performance and Energy Analysis (BIM기반 공동주택 환경성능 및 에너지 해석 시스템 통합 개발)

  • Suh, Hye-Soo;Lee, Soo-Hyun;Lim, Jae-Sang;Choi, Cheol-Ho
    • Journal of KIBIM
    • /
    • v.4 no.2
    • /
    • pp.1-9
    • /
    • 2014
  • As interest in green building has increased, construction market has evolved through BIM-based architecture also, BIM-based technologies have been developed simultaneously. Due to this aspect, the need of environmental analysis software utilizing BIM data became essential. This study shows that BIM-based integrated module provides objective analysis to proceed quick decision-making for a proposal. In addition to that, this integrated module creates a model through BIM data to analyze and report residential environment and energy consumption such as, daylight, view, ventilation and privacy in order to practically apply the BIM technology from the schematic design.