• Title/Summary/Keyword: module configuration

Search Result 344, Processing Time 0.022 seconds

Strength of Joint in Floating Structures Constructed with Precast Concrete Modules (프리캐스트 콘크리트 부유식 구조물의 모듈 접합부 강도)

  • Yang, In-Hwan;Kim, Kyung-Cheol
    • Journal of Navigation and Port Research
    • /
    • v.36 no.3
    • /
    • pp.197-204
    • /
    • 2012
  • The behavior of floating structures constructed with precast concrete modules is dependent of the behavior of joints between the concrete modules. To accurately predict the floating structure response under the ultimate loading, knowledge of joint behavior is essential. This study aims to investigate the structural behavior of concrete module joints under various configuration of joint and confining stress levels. The shear behavior, shear capacity and crack patterns of shear keys in concrete module have been studied. Test results indicated that the shear capacity of joints increased as shear key inclination increased. In addition, shear capacity of concrete module joint increased with the increase of confining stress levels. The test results were compared with the AASHTO design recommendations. The AASHTO design recommendations underestimated the shear strength of test specimens.

High Power Density Open-frame Type DC-DC Converter Module with Constant Current Control (정전류 제어 기능이 부가된 고전력밀도의 개방형 DC-DC 컨버터 모듈)

  • Lee Darl-Woo;Ahn Tae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.380-387
    • /
    • 2005
  • We report the performance of an open-frame type low-voltage high-current DC-DC converter module developed using an active clamp forward converter circuit and single ended rectifier. The converter module is designed with the specifications of an 3.3V output voltage, 30A output current, 100W output power and 36-75V input voltage. The synchronous rectifier is used to reduce the conduction loss at high current level and constant current control using precision PCB resistance is adapted to enhance the over current protection function in the system configuration. A prototype converter module is successfully implemented within 8mm height and quarter brick size (58x37mm) and recorded an $95W/in^3$ power density, 90.6$\%$ efficiency and 0.07$\%$ voltage regulation for the entire Input voltage range, thereby demonstrating its application potentials to future telecommunication electronics.

A Plug-in Development for Interworking between SysML Model and Plant Information (SysML모델과 플랜트정보 간 상호연동을 위한 플러그인 개발)

  • Kim, Joon Young;Lee, Tae Kyong;Cha, Jae Min
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.15 no.2
    • /
    • pp.17-30
    • /
    • 2019
  • Due to difficulties in tracking design information of existing document-based configuration management, the research on the development of plant SysML model was started to apply the model-based system engineering methodology to comprehensively manage various design information. However, until now, in order to create the SysML model, the engineers are checking the design information and inputting it to the SysML model. This process requires a lot of time and manpower, it is required to minimize it. Therefore, this study has recognized the problem, a plug-in that extracts the plant design information in the design document and automatically converts the SysML plant model from it. Specifically, the development was performed in the following order. First, the extraction file was selected as the most commonly used Excel file as the plant design document. Next, the design information in the document was analyzed, and extracted information including tag number, name, and the capacity were selected. Finally, the plant SysML model conversion module was implemented. The developed plug-in is confirmed that the task load of the engineers by the SysML model conversion can be minimized and the model can be generated more quickly and accurately.

Electric Propulsion Naval Ships with Energy Storage Modules through AFE Converters

  • Kim, So-Yeon;Choe, Sehwa;Ko, Sanggi;Kim, Sungmin;Sul, Seung-Ki
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.402-412
    • /
    • 2014
  • This paper proposes a novel electric propulsion system for naval ships, which consists of Active Front End (AFE) converters directly connected to battery Energy Storage Modules (ESMs). Employing the proposed AFE converters with ESMs in the power systems of naval ships can enhance the reliability and quality of the electric power. Furthermore, the fuel-efficiency of the generator can be improved by a higher loading factor of the generator and its prime movers. The proposed AFE configuration does not require an additional dedicated DC/AC converter for the ESMs. Instead of that, the AFE converter itself can control the DC link voltage and the discharging and/or charging of the ESMs. A control scheme to achieve these control objectives is also presented in this paper. The overall power system, including the generators and electrical loads of a naval ship, is implemented by a small scaled Power Hardware-In-the-Loop (PHIL) simulator. Through this experimental setup, the proposed system configuration and the power control strategies are verified. It is shown that the fuel-efficiency and transient dynamics can be improved in the normal and contingency operation modes.

Grounding Radial Stub for the Vertical Microstrip Transition (수직으로 전이되는 마이크로스트립의 접지용 방사형 스터브)

  • Gwon, Deok-Gyu;Lee, Jong-Ho;Lee, Hae-Yeong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.3
    • /
    • pp.58-63
    • /
    • 2000
  • For the microwave high density devices and modules of the 3D configuration, we proposed radial stub for the ground connection. The proposed structure is analyzed by the full-wave analysis of finite element method (FEM) and characterized experimentally. The results show that the return loss is more than 15 dB and the insertion loss is less than 0.5 dB in the frequency range from 2.5 GHz to 6.3 GHz. The proposed grounding scheme will be useful for the ground connection lot the microwave high density devices and module of 3D configuration.

  • PDF

Performance Comparison of HEVC and H.264/AVC Standards in Broadcasting Environments

  • Dissanayake, Maheshi B.;Abeyrathna, Dilanga L.B.
    • Journal of Information Processing Systems
    • /
    • v.11 no.3
    • /
    • pp.483-494
    • /
    • 2015
  • High Efficiency Video Coding (HEVC) is the most recent video codec standard of the ITU-T Video Coding Experts Group and the ISO/IEC Moving Picture Experts Group. The main goal of this newly introduced standard is for catering to high-resolution video in low bandwidth environments with a higher compression ratio. This paper provides a performance comparison between HEVC and H.264/AVC video compression standards in terms of objective quality, delay, and complexity in the broadcasting environment. The experimental investigation was carried out using six test sequences in the random access configuration of the HEVC test model (HM), the HEVC reference software. This was also carried out in similar configuration settings of the Joint Scalable Video Module (JSVM), the official scalable H.264/AVC reference implementation, running on a single layer mode. According to the results obtained, the HM achieves more than double the compression ratio compared to that of JSVM and delivers the same video quality at half the bitrate. Yet, the HM encodes two times slower (at most) than JSVM. Hence, it can be concluded that the application scenarios of HM and JSVM should be judiciously selected considering the availability of system resources. For instance, HM is not suitable for low delay applications, but it can be used effectively in low bandwidth environments.

Performance Test for a Horizontal Regenerative Evaporative Cooler (수평형 재생증발식 냉방기의 성능시험)

  • Song, Gwi-Eun;Lee, Dae-Young
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.621-626
    • /
    • 2006
  • Regenerative evaporative cooling is known as an environment-friendly and energy efficient cooling method. A regenerative evaporative cooler (REC) consisting of dry and wet channels is able to cool down the air stream below the inlet wet-bulb temperature. In the regenerative evaporative cooler, the cooling effect is achieved by redirecting a portion of the air flown out of the dry channel into the wet channel and spraying water onto the redirected air. In this study, a horizontal regenerative cooler is considered. In the horizontal regenerative cooler, the flow direction of evaporating water has a right angle to the flow direction of supply air. This difference was investigated with visualization technique and simplified 2-module performance test was done in a thermo-environment chamber. Optimum design configuration is changed due to the wet channel which are easily fully covered with evaporating water and block the air flow inside the channel. Applying the optimized fin configuration design with the highly wetting surface treatment, a regenerative evaporative cooler was fabricated and tested to Identify the cooling performance improvement and operation characteristics. From the experimental results at the intake condition of $32^{\circ}C$ and 50% RH, the supply temperature was measured to be around $23.4^{\circ}C$. The cooling effectiveness based on the inlet dewpoint temperature was evaluated 73% which is almost close to the design expectation.

  • PDF

Experimental Study on an Underwater Pole Climb Robot for the Maintenance of Offshore Wind Turbine Substructures (해상풍력발전 지지구조물의 유지보수용 수중 기둥등반로봇에 관한 실험적 연구)

  • Im, Eun Cheol;Ko, Jin Hwan
    • The Journal of Korea Robotics Society
    • /
    • v.17 no.2
    • /
    • pp.238-244
    • /
    • 2022
  • Maintenance works of offshore wind turbines could take a longer time, which causes the reduction of their energy production efficiency, than those of onshore wind turbines owing to severe offshore environment. Subsequently, preventive maintenance measures are required to increase the production efficiency. Thus, we proposed a wheel-based Underwater Pole Climbing Robot (UPCR) platform, which was aimed at the periodic inspection and maintenance of the substructures of the offshore wind turbines, with three advantages: high speed, good mobility and low power consumption. In the proposed platform, a self-locking system using a gripper module was adopted for preventing slippery problem and a dual configuration was chosen for moving on a branched structure. As a result, the proposed robot was able to continuously climb, preserve it's position at the pole without consuming energy, and move from the pole to the other branched pole. The results of this research show that the UPCR has basic moving capabilities required for the underwater work for the substructures of the offshore wind turbines.

Development of E-learning System for Vocational Rehabilitation of Students with Mental Retardation (정신지체 학생의 직업교육을 위한 e-러닝 시스템 개발)

  • Kim, C.G.;Ryu, G.J.;Song, B.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.6 no.2
    • /
    • pp.49-54
    • /
    • 2012
  • In this study, an E-learning system was developed for vocational rehabilitation training of intellectual disabilities. The developed system is available to have acquirement of knowledge through step by step learning and is configured to relearn through problem-solving and demonstration video. In addition, the learned information was composed to check the configuration which is correctly learning through rehearsal function. The device for rehearsal consists of a transmitter and the receiver. The transmitter is formed Pressure sensor, IR sensor for detecting client's work and Bluetooth module for wireless network. The receiver includes a Bluetooth module for wireless network and USB input terminal for communication with computer.

  • PDF

The Characteristic of TEC Power Consumption of Laser Diode Module (레이저다이오드 모듈 냉각용 TEC 소비전력 특성)

  • Lee Jong Jin;Yu Chong Hee;Kang Hyun Seo;Koh Jai Sang
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.3 s.32
    • /
    • pp.71-76
    • /
    • 2004
  • The power consumption of TEC for Laser diode cooling was predicted by 3-D FEM simulation and verified by experiment. The operating conditions such as power consumption of Laser diode, set temperature, ambient temperature, resistance of thermal path was considered to estimate the TEC power consumption. Using 3-D FEM simulation, the relation between TEC configuration defined by the pellet dimension and the number and power consumption was investigated for low power consumption scheme. As a result, as the thermal resistance of the pellet increased, the power consumption decreased.

  • PDF