• Title/Summary/Keyword: modulation-transfer function (MTF)

Search Result 201, Processing Time 0.03 seconds

Image Quality Evaluation of Digital X-Ray Detector Using Amorphous Selenium Layer and Amorphous Silicon TFT Array (비정질 셀레늄층과 비정질 실리콘TFT배열을 사용하는 디지털 X-선 검출기의 영상특성 평가)

  • Kim, Chang-Won;Yoon, Jeong-Key;Kim, Jong-Hyo
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.219-226
    • /
    • 2008
  • In this study, we have conducted characterization of imaging performance for a flat panel digital X-ray detector using amorphous Selenium and a-Si TFT which was developed by the authors. The procedures for characterization were in concordance with internationally recommended standards such as IEC (international electrotechnical commission). The measures used for imaging performance characterization include response characteristic, modulation transfer function (MTF), detective quantum efficiency (DQE), noise power spectrum (NPS), and quantum limited performance. The measured DQEs at lowest and highest spatial frequencies were 40% and 25% respectively, which was superior to that of commercial products by overseas vendor. The MTF values were significantly superior to that of CR and indirect type DRs. The quantum limited performance showed the detector was limited by quantum noise at the entrance exposure level below 0.023 mR, which is sufficiently low for general X-ray examination.

  • PDF

A Study on Image Coding using the Human Visual System and DCT (시각특성과 DCT를 이용한 영상부호화에 관한 연구)

  • 남승진;최성남;전중남;박규태
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.4
    • /
    • pp.323-335
    • /
    • 1992
  • In this paper, an adaptive cosine transform coding scheme which incorporate human visual properties into the coding scheme is investigated. Human vision is relatively sensitive to mid-frequency band, and insensitive to very low and very high frequency band. These property was mathematically modelled with MTF(Modulation Transfer Function) through many psychovisual experiment. DCT transforms energy in spatial domain into frequency domain, so can exploit the MTF very efficiently. Another well-known visual characteristics is spatial masking effect that visibility of noise is less in regions of high activity than in regions of low activity. Proposed coding scheme imploys quantization matrix which represent the properties of these spatial frequency response of human vision, and adaptively quality of an image. To compute the activity index of an image block, simple operation is performed in spatial domain, and according to activity index. block of low activity region is more exactly quantized relatively than that of high activity region. Results showed that, at low bit rate, the subjective quality of the reconstructed images by proposed coding scheme is acceptible than that of coding scheme without HVS properties.

  • PDF

Study on the Resolution Characteristics by Using Magnetic Resonance Imaging 3.0T (3.0T 자기공명영상을 이용한 해상력 특성에 대한 연구)

  • Min, Jung-Whan;Jeong, Hoi-Woun;Han, Ji-Hyun;Lee, Si-Nae;Han, Song-Yi;Kim, Ki-Won;Kim, Hyun-Soo;Son, Jin-Hyun
    • Journal of radiological science and technology
    • /
    • v.43 no.4
    • /
    • pp.251-257
    • /
    • 2020
  • This study was purpose to quantitative evaluation of edge method of modulation transfer function(MTF) and physical image characteristics of by obtain the optimal edge image by using magnetic resonance imaging(MRI). The MRI equipment was used (MAGNETOM Vida 3.0T MRI, Siemense healthcare system, Germany) and the head/neck matrix shim MR coil were 20 channels(elements) receive coil. The MTF results of showed the best value of 0.294 based on the T2 Nyquist frequency of 1.0 mm-1. The MTF results of showed that the T1 image is 0.160, the T1 CE image is 0.250, T1 Conca2 image is 0.043, and the T1 CE (Concatenation) Conca2 image is 0.190. The T2 image highest quantitatively value for MTF. The physical image characteristics of this study were to that can be used efficiently of the MRI and to present the quantitative evaluation method and physical image characteristics of 3.0T MRI.

A Study on the MTF Analysis for the Three Primary Colors of Light within Diffraction-Limitted System (회절제한시스템에 속한 빛의 3원색의 변조전달함수 해석에 관한 연구)

  • Che, Kyu-Shik;Chang, Won-Seok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.863-866
    • /
    • 2012
  • The optical system develops remarkably as well as the development of civilization. The modulation transfer function(MTF) was introduced as one of the important estimation methods to estimate the performance of optical systems. The calculation of MTF is very boring and tiresome. We express the MTF curves three primary colors of light in the diffraction-limitted systems.

  • PDF

Spatial Characterization of MAC, a High-Resolution Optical Earth Observation Camera for Small Satellites

  • Kim Eugene D.;Choi Young-Wan;Yang Ho-Soon;Ismail Mohd. Afiq bin
    • Journal of the Optical Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.79-83
    • /
    • 2005
  • Spatial calibrations have been performed on the Medium-sized Aperture Camera (MAC) of the RazakSAT satellite. Topics discussed in this paper include the measurements of system modulation transfer function (MTF), relative pixel line-of-sight (LOS), and end-to-end imaging tests. The MTF measurements were made by capturing the scanned knife-edge image on a pixel, and an issue in the MTF calculation algorithm is discussed. The method used to place the focal plane at the correct focal position is described, since they make use of MTF measurements. Relative LOS measurements are done by theodolite measurements of the telescope. Qualitative ground test result of end-to-end imaging is given.

The Performance Analysis of the Satellite EOS(Electro Optical Subsystem) using the Design Parameters of Camera Electronics (카메라 전자부 설계 파라미터를 이용한 위성 전자광학시스템의 성능분석)

  • Kong, Jong-Pil;Heo, Haeng-Pal;Kim, Young-Sun;Park, Jong-Euk
    • Aerospace Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.73-78
    • /
    • 2007
  • In this study, we reviewed the variations of GSD, line rate of a electro-optical payload caused by the changes of operational altitude and attitude of a satellite by applying design parameters of the EC6 which is under development. we also reviewed adjustable increments/decrements of line_rate which are limited by CEU(Camera Electronic Unit) design and then the effect on the MIF(Modulation Transfer Function) performance due to the un-synchronization between line_rate of EOS and ground scan velocity of the satellite based on the design parameters of CEU to show that CEU design is appropriate in terms of line_rate control of EOS.

  • PDF

A Simple Human Visual Weighted Hadamard Transform Image Coding (단순한 시각적 하중에 의한 아다마르 영상부호화)

  • Hwang, Jae-Jeong;Lee, Moon-Ho
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.4
    • /
    • pp.98-105
    • /
    • 1989
  • Various models incorporating Human Visual System (HVS) with the Hadamard transform (HT) represented by Walsh functions are considered. Using the exact frequency components of HT basis functions, the optimum modulation transfer function (MTF) which has a higher peak frequency than DCT schemes is obtimum modulation transfer function (MTF) which has a higher peak frequency than DCT schemes is obtained analytically and visually. The main criterion, for error measurement, is errors at the block boundaries which is an important factor in transform coding. The scheme which has no inverse HVS is proposed. It causes some degradation of image data but it is insignigicant. Crossing area of 4 blocks is equalized by the HVS weighting coefficients. The HVS weighted coding results in perceptually higher quality images compared with the unweighted scheme.

  • PDF

Evaluation of Resolution of UAV-Image Using Circular Target (Circular target을 이용한 무인항공영상의 해상도 평가)

  • Lee, Jae-One;Sung, Sang-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.474-480
    • /
    • 2019
  • We propose a method to evaluate a Modulation Transfer Function (MTF) using a circular target. In addition, a MATLAB GUI-based resolution analysis tool was developed to enhance the reliability of UAV image quality and the efficiency of the work. For this purpose, images were taken with an FC-6310 during flights at altitudes of 80 m, 120 m, and 150 m and by an iXM-100 at altitudes of 150 m, 200 m, and 400 m. The MTFs of UAV images were compared with traditional photogrammetry by measuring and analyzing MTFs on images taken by the UltraCAM Eagle Mark-2 sensor at a flight altitude of 1000 m. The results show that ${\sigma}MTF$ of the FC-6310 were 0.431(80 m), 0.524(120 m), and 0.699(150 m), and those of the iXM-100 were 0.332(150 m), 0.393(200 m), and 0.631(400 m), respectively. At the altitude of 150 m, the image quality of the iXM-100, which has a high-performance camera, was very high, and the effect of the camera performance on the image quality was confirmed. In addition, the ${\sigma}MTF$ of the UltraCAM Eagle Mark-2 was 0.711 due to the high flight altitude. This was the worst value among all UAV images. However, the ${\sigma}MTF$ of the FC-6310 at 150-m altitude was 0.699, which is almost the same as that of a manned aerial image.

Signal and Noise Analysis of Indirect-Conversion Digital Radiography Detectors Using Linear-systems Transfer Theory (선형시스템 전달이론을 이용한 간접변환방식 디지털 래디오그라피 디텍터의 신호 및 잡음 분석)

  • Yun, Seung-Man;Lim, Chang-Hwy;Han, Jong-Chul;Joe, Ok-La;Kim, Jung-Min;Kim, Ho-Kyung
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.261-273
    • /
    • 2010
  • For the use of Indirect-conversion CMOS (complementary metal-oxide-semiconductor) detectors for digital x-ray radiography and their better designs, we have theoretically evaluated the spatial-frequency-dependent detective quantum efficiency (DQE) using the cascaded linear-systems transfer theory. In order to validate the developed model, the DQE was experimentally determined by the measured modulation-transfer function (MTF) and noise-power spectrum, and the estimated incident x-ray fluence under the mammography beam quality of W/Al. From the comparison between the theoretical and experimental DQEs, the overall tendencies were well agreed. Based on the developed model, we have investigated the DQEs values with respect to various design parameters of the CMOS x-ray detector such as phosphor quantum efficiency, Swank noise, photodiode quantum efficiency and the MTF of various scintillator screens. This theoretical approach is very useful tool for the understanding of the developed imaging systems as well as helpful for the better design or optimization for new development.

Performance Evaluation of MTF Peak Detection Methods by a Statistical Analysis for Phone Camera Modules

  • Kwon, Jong-Hoon;Rhee, Hyug-Gyo;Ghim, Young-Sik;Lee, Yun-Woo
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.150-155
    • /
    • 2016
  • To evaluate the autofocusing performance of recent mobile phone cameras, it is necessary to determine the peak position of the center field MTF (Modulation Transfer Function), -known as the through focus MTF- of the module. However, the MTF peak position found by conventional methods deviates from the ideal position due to the focus scanning resolution of mobile phone cameras. This inaccurate peak position results in false judgements of the optical performance, leading to yield losses or customer complaints. An increase in the focus scanning resolution can address this problem, but the manufacturing UPH (Unit per Hour) level will also unfortunately increase as well, resulting in a loss of manufacturing capabilities. In this paper, several fitting models are studied to find an accurate MTF peak position within a short period of time. With an analysis of a large amount of manufacturing data, it is demonstrated that the fitting methods can reduce false judgements and simultaneously increase the capabilities of the manufacturing system.