• Title/Summary/Keyword: modified test

Search Result 3,950, Processing Time 0.033 seconds

Optimal Signal Segment Length for Modified Run-test and RA(reverse arrangement)-test for Assessing Surface EMG Signal Stationarity (표면근전도 신호의 정상성 검사를 위한 수정된 Run-검증과 RA-검증에 최적인 신호분할 길이)

  • Lee, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.8
    • /
    • pp.1128-1133
    • /
    • 2014
  • Most of the statistical signal analysis processed in the time domain and the frequency domain are based on the assumption that the signal is weakly stationary(wide sense stationary). Therefore, it is necessary to know whether the surface EMG signals processed in the statistical basis satisfy the condition of the weak stationarity. The purpose of this study is to find optimal segment length of surface EMG signal for assessing stationarity with the modified Run-test and RA-test. Ten stationary surface EMG signals were simulated by AR(autoregressive) modeling, and ten real surface EMG signals were recorded from biceps brachii muscle and then modified to have non-stationary structures. In condition of varying segment length from 20ms to 100ms, stationarity of the signals was tested by using six different methods of modified Run-test and RA-test. The results indicate that the optimal segment length for the surface EMG is 30ms~35ms, and the best way for assessing surface EMG signal stationarity is the modified Run-test (Run2) method using this optimal length.

The Modified Hanbok Jeogori Pattern Development Using Virtual Dressing System - Based on Female Bodice Pattern -

  • Jeon, Seong Yeon;Wee, Hye Jung
    • Journal of Fashion Business
    • /
    • v.21 no.6
    • /
    • pp.66-76
    • /
    • 2017
  • This study used a virtual wearing system equipped with body shape data with a 3D scanner, based on a female basic bodice, to develop a modified Hanbok Jeogori with high fitness capabilities to provide basic data for the development of the modified Hanbok Jeogori pattern for the academic and industrial fields. In this study, the representative modified Hanbok design which most frequently appeared in broadcasting ads and on line was selected. The wearing test was conducted by six professionals, and three times wearing tests were implemented based on 17 evaluation items. The data for this study was processed statistically using SAS 9.0. We conducted, the F-test for significance verification, the Duncan-test for a post test, and a correlation analysis of Cronbach's alpha coefficient for a reliability test of dressing test results were implemented for each of the three tests. The pattern of the developed modified Hanbok Jeogori overcame the defects of the short length of the conventional modified hanbok, and could fix the length issue. The developed Hanbok pattern solved the overlapping problem of the shoulder, back neck point-sleeve length(Whajang), and armhole, displayed in a straight line from the Godae point of the previous modified Hanbok; it suggested the position of the Seop and neck line in the basic bodice. Based on this, the Seop width, Git form, Goreum and the width, length, and position of the string whose dimensions can differ in accordance with the trend can be applied in various forms.

Burn-up Characteristics of Polymer-Modified Cement Mortar Used for Building Repair (고온시에서의 폴리머 시멘트 모르타르의 연소특성에 관한 연구)

  • Kim, Hyung-Jun;Noguchi, Takahumi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.295-298
    • /
    • 2012
  • Repair and strengthening is necessary to extend the service life of existing buildings. Polymer-modified cement mortar (PCM) has been extensively used as a high performance material particularly for finishing and repairing works in concrete building because of itsexcellent adhesion, waterproofing, resistance to chemical attack, and workability. As PCM contains organic polymer, it is necessary to clarify its properties at high temperature under fire, on which sufficient data are not available. This paper evaluated the burn-up characteristics of polymer-modified cement mortar with cone calorimeter test, non-combustibility test and flammability test with experimental parameters such as the types of polymer, unit-polymer content, polymer-cement ratio and thickness of the specimen.

  • PDF

Optimum multi-objective modified step-stress accelerated life test plan for the Burr type-XII distribution

  • Srivastava, P.W.;Mittal, N.
    • International Journal of Reliability and Applications
    • /
    • v.15 no.1
    • /
    • pp.23-50
    • /
    • 2014
  • This paper deals with formulation of optimum multi-objective modified step-stress accelerated life test (ALT) plan for Burr type-XII distribution under type-I censoring. Since it is impractical to estimate only one objective parameter after conducting costly ALT tests; also, it is not desirable to assume instantaneous changes in stress levels because of limited capacity of test equipments and the presence of undesirable failure modes, therefore, an optimum multi-objective modified step-stress ALT plan has been designed. The optimal test plan consists in determining the optimum low stress level and optimal time at which stress starts linearly increasing from low stress by minimizing the weighted sum of the asymptotic variances of the maximum likelihood estimator of quantile lifetimes at design constant stress. The method developed has been illustrated using an example. Sensitivity analysis has been carried out. Comparative study has also been done to highlight the merits of the proposed model.

  • PDF

An Accuracy Analysis of Run-test and RA(Reverse Arrangement)-test for Assessing Surface EMG Signal Stationarity (표면근전도 신호의 정상성 검사를 위한 Run-검증과 RA-검증의 정확도 분석)

  • Lee, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.291-296
    • /
    • 2014
  • Most of the statistical signal analysis processed in the time domain and the frequency domain are based on the assumption that the signal is weakly stationary(wide sense stationary). Therefore, it is necessary to know whether the surface EMG signals processed in the statistical basis satisfy the condition of weak stationarity. The purpose of this study is to analyze the accuracy of the Run-test, modified Run-test, RA(reverse arrangement)-test, and modified RA-test for assessing surface EMG signal stationarity. Six stationary and three non-stationary signals were simulated by using sine wave, AR(autoregressive) modeling, and real surface EMG. The simulated signals were tested for stationarity using nine different methods of Run-test and RA-test. The results showed that the modified Run-test method2 (mRT2) classified exactly the surface EMG signals by stationarity with 100% accuracy. This finding indicates that the mRT2 may be the best way for assessing stationarity in surface EMG signals.

A Study on the Antibacterial Activity of Chitosan on the MRSA by the AATCC Test Method 100 and Modified AATCC Test Method 100

  • Choi, Jeong-Im;Jeon, Dong-Won
    • Fashion & Textile Research Journal
    • /
    • v.4 no.6
    • /
    • pp.557-563
    • /
    • 2002
  • Water-soluble chitosan and water-insoluble chitosan with molecular weight of 2,000,000, 500,000, 80,000, and 40,000 with more than 90%of degree of deacetylation were produced to test antibacterial activity of chitosan against a pathogenic bacteria, Methicillin Resistant Staphylococcus aureus(MRSA). the AATCC Test Method 100and Modified AATCC Test Method 100 were used to evaluate the antibacterial activity of chitosan. Antibacterial activity of chitosan/acetic acid solution was the same when they were tested by two different methods, but those of polyester fabrics treated with chitosan/acetic acid solution were different in different antibacterial test. So several problems were found in the experimental methods. The AATCC Test Method 100 seems that excessive nutrition exists in inoculum solution by quantitative analysis on the basis the result of antibacterial activity on chitosan/acetic acid solution and amount of chitosan attached to the surface of treated fabrics.

The Effect of Modified CIMT Combined with Kinesio-Taping on Upper Limb Function in Hemiplegic Patients (테이핑을 이용한 건측 억제유도 운동이 만성 뇌졸중 환자의 상지기능에 미치는 영향)

  • Kim, Myung-Kwon;Ji, Sang-Ku;Jun, Hye-Jin;Lee, Chang-Ryeol;Lee, Moon-Hwan
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.4 no.3
    • /
    • pp.183-192
    • /
    • 2009
  • Purpose:This study was conducted to investigate whether modified CIMT with Kinesio-Taping on paretic upper limb effects upper limb function in stroke patients in comparison to those receiving only modified CIMT. Methods:20 out-patients with hemiplegia were randomly assigned to either an experimental or a control group. Both groups received modified CIMT during a 10-week period. Additionally, an experimental group received modified CIMT with Kinesio-Taping on paretic upper limb and trunk. Results:In Manual function test, Grip strength, Jebsen-Taylor hand function test, MAL(Motor Activity Log) and Functional independence measure (FIM) were significantly different at all intervals of the study period(0, 3, 6, 10-week) in the experimental and control groups(p<.05). Exceptionally there was no significant difference in Jebsen-Taylor hand function test between the experimental and control groups. Conclusion:These results suggest that modified CIMT with Kinesio-taping improve the upper limb function. And also increase usage of affected upper limb and assist in daily living activity more than only modified CIMT.

  • PDF

Derivation of Modified Anderson-Darling Test Statistics and Power Test for the Gumbel Distribution (Gumbel 분포형의 수정 Anderson-Darling 검정통계량 유도 및 기각력 검토)

  • Shin, Hong-Joon;Sung, Kyung-Min;Heo, Jun-Haeng
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.9
    • /
    • pp.813-822
    • /
    • 2010
  • An important problem in frequency analysis is the estimation of the quantile for a certain return period. In frequency analysis an assumed probability distribution is fitted to the observed sample data to estimate the quantile at the upper tail corresponding to return periods which are usually much larger than the record length. In most cases, the selection of an appropriate probability distribution is based on goodness of fit tests. The goodness of fit test method can be described as a method for examining how well sample data agrees with an assumed probability distribution as its population. However it gives generally equal weight to differences between empirical and theoretical distribution functions corresponding to all the observations. In this study, the modified Anderson-Darling (AD) test statistics are provided using simulation and the power study are performed to compare the efficiency of other goodness of fit tests. The power test results indicate that the modified AD test has better rejection performances than the traditional tests. In addition, the applications to real world data are discussed and shows that the modified AD test may be a powerful test for selecting an appropriate distribution for frequency analysis when extreme cases are considered.

A Regression Test Selection and Prioritization Technique

  • Malhotra, Ruchika;Kaur, Arvinder;Singh, Yogesh
    • Journal of Information Processing Systems
    • /
    • v.6 no.2
    • /
    • pp.235-252
    • /
    • 2010
  • Regression testing is a very costly process performed primarily as a software maintenance activity. It is the process of retesting the modified parts of the software and ensuring that no new errors have been introduced into previously tested source code due to these modifications. A regression test selection technique selects an appropriate number of test cases from a test suite that might expose a fault in the modified program. In this paper, we propose both a regression test selection and prioritization technique. We implemented our regression test selection technique and demonstrated in two case studies that our technique is effective regarding selecting and prioritizing test cases. The results show that our technique may significantly reduce the number of test cases and thus the cost and resources for performing regression testing on modified software.

Delay Test for Boundary-Scan based Architectures (경계면 스캔 기저 구조를 위한 지연시험)

  • 강병욱;안광선
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.6
    • /
    • pp.199-208
    • /
    • 1994
  • This paper proposes a delay fault test technique for ICs and PCBs with the boundary-scan architectures supporting ANSI/IEEE Std 1149.1-1990. The hybrid delay fault model, which comprises both of gate delay faults and path delay faults, is selected. We developed a procedure for testing delay faults in the circuits with typical boundary scan cells supporting the standard. Analyzing it,we concluded that it is impractical because the test clock must be 2.5 times faster than the system clock with the cell architect-ures following up the state transition of the TAP controller and test instruction set. We modified the boundary-scan cell and developed test instructions and the test procedure. The modified cell and the procedure need test clock two times slower than the system clock and support the ANSI/IEEE standard perfectly. A 4-bit ALU is selected for the circuits under test. and delay tests are simulated by the SILOS simulator. The simulation results ascertain the accurate operation and effectiveeness of the modified mechanism.

  • PDF