• 제목/요약/키워드: modified response displacement method

검색결과 41건 처리시간 0.028초

도시철도 지중 콘크리트 구조물의 내진해석법 적용에 관한 연구 (A Study of seismic analysis method of urban rail transit's underground concrete structure)

  • 이희영;이동호;김은겸
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.1159-1164
    • /
    • 2005
  • Seismic analysis methods in use on ground structure are equivalentstatic analysis, response-displacement method and dynamic analysis etc. Equivalentstatic analysis does not considerdynamic effect, and dynamic analysis process is very complex. then 'Urbanrail transit earthquake-resistance design standard (2005.06)' is persuading that analyze by response displacement method that consider enough dynamic effect of ground structure statically. But, It is very complex and difficult to apply response-displacement method in the field. So, modified equivalentstatic analysis or pseudo static analysis that is easy to apply in the field and have rationality of design is practically used. In this study, I try to prescribe the applicable scale of structure and static analysis that have calculative effectiveness about response-displacement method by comparing and analyzing the result of each analysis method according to the scale of urban rail transit' box type concrete structure and by performing seismic analysis that apply modified equivalentstatic analysis, pseudo static analysis and response-displacement method changing the kind of ground, depth of bedrock, size of structure.

  • PDF

BOX 형 지하구조물의 내진설계 기준 확립을 위한 해석기법개발 (Development of the Modified Seismic Coefficient Method to Establish Seismic Design Criteria of Buried Box Structures.)

  • 박성우
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.194-201
    • /
    • 2000
  • In this study the modified seismic coefficient method for seismic analysis of buried box structures is developed for practical purpose. The loading coefficient in the modified seismic coefficient method is determined from the results of the response displacement analysis. In the developed method adequate velocity response spectrum in accordance with soil condition is also needed to seismic design of buried box structures, In order to investigate applicability of the modified seismic coefficient method various analyses are performed with different parameters such as depth of base rock height and width of box buried depth and value of standard penetration test. Results from the modified seismic coefficient method are compared with those of the response displacement method in terms of the maximum bending moment and the location of it. From the comparison it is shown that the feasibility of the modified seismic coefficient method for seismic analysis of buried box structures.

  • PDF

역량스펙트럼 방법과 수정변위계수법을 이용한 다경간 교량의 내진성능 평가 (Seismic Performance Evaluation of Multi-Span Bridges using CSM and modified DCM)

  • 남왕현;송종걸;정영화
    • 산업기술연구
    • /
    • 제26권B호
    • /
    • pp.119-126
    • /
    • 2006
  • Capacity spectrum method(CSM) of ATC-40(1996) and displacement coefficient method(DCM)of FEMA-273(1997) are applied to evaluate the seismic performance of bridges. In this study, equivalent response is obtained from nonlinear static analysis for the 3spans continues bridge and nonlinear maximum displacement response is calculated using CSM and DCM. Nonlinear maximum displacement response of DCM is larger than this of CSM. It is method that DCM can evaluate target displacement and ductility of structural to be easy and simple, but tend to overestimate the maximum displacement response. Therefore, this method is mainly used at preparation design level to evaluate the structural response. It is not desirable to evaluate the seismic performance using DCM.

  • PDF

국내 특성이 반영된 지하구조물의 내진설계를 위한 수정응답변위법 (Modification of Response Displacement Method for Seismic Design of Underground Structures under Domestic Conditions)

  • 김명철;김영일;조우연;김문겸
    • 한국지진공학회논문집
    • /
    • 제8권2호
    • /
    • pp.83-93
    • /
    • 2004
  • 본 연구에서는 지하구조물의 내진 설계를 위한 수정된 응답변위법을 제안하였다. 먼저 기존 응답변위법의 적용성을 검증하기 위해서 매설심도와 지반조건을 변수로 하여 국내의 특성이 반영된 경우에 대한 해석을 수행하였으며 정밀 동적 해석의 결과와 비교하였다. 최대휨모멘트 및 상대 변위를 비교한 결과, 응답변위법의 정확도에 영향을 크게 미지는 속도응답스펙트럼과 지반반력계수 산정의 필요성이 확인되었다. 따라서 국내의 실정에 맞도록 수정된 속도응답스펙트럼과 새로운 지반반력계수 산정식 제안을 위한 방법을 고찰하였다. 제안된 응답변위법의 타당성 및 적용성을 검증하기 위하여, 지반의 조건 및 구조물의 크기 매설심도, 기반암의 위치를 변화시키면서 해석을 수행하였다. 응답변위법의 해석결과와 정밀 동적 해석법의 결과를 비교ㆍ분석하여 국내 지하구조물의 내진 설계를 위한 응답변위법의 적용 가능성을 검증하였다.

정적변위를 고려한 플랜트 구조물의 단자유도 폭발 해석 (Blast Analysis of Single Degree of Freedom Plant Structures Considering Static Displacement)

  • 이재균;이승훈;김한수
    • 한국전산구조공학회논문집
    • /
    • 제35권5호
    • /
    • pp.317-324
    • /
    • 2022
  • 본 논문에서는 등가 단자유도를 이용하여 구조부재의 정적변위를 고려하는 해석기법을 제시하였다. 기존의 단자유도 비선형 동적 해석 알고리듬을 구조부재의 초기정적변위의 영향을 고려할 수 있도록 개선하였다. 가정된 폭발하중 지속시간과 부재의 고유주기 비에 따라 정적변위가 최대응답에 미치는 영향의 차이와 폭발하중의 방향과 초기변위의 방향에 따른 차이를 확인하였다. 이에 따라 기존의 응답 차트를 정적변위를 고려할 수 있도록 폭발하중의 형태에 따라 각각 제시하였다. 설계 예제를 정적변위가 고려된 응답 차트에 적용하여 부재의 최대 변위를 비교 및 분석하였다. 본 연구의 결과를 통해 초기 정적변위를 고려한 구조부재의 최대응답을 쉽게 산정할 수 있으며 본 연구에서 제시한 응답 차트는 플랜트 또는 군사시설물의 내폭 설계에 활용될 수 있다.

Modified complex mode superposition design response spectrum method and parameters optimization for linear seismic base-isolation structures

  • Huang, Dong-Mei;Ren, Wei-Xin;Mao, Yun
    • Earthquakes and Structures
    • /
    • 제4권4호
    • /
    • pp.341-363
    • /
    • 2013
  • Earthquake response calculation, parametric analysis and seismic parameter optimization of base-isolated structures are some critical issues for seismic design of base-isolated structures. To calculate the earthquake responses for such non-symmetric and non-classical damping linear systems and to implement the earthquake resistant design codes, a modified complex mode superposition design response spectrum method is put forward. Furthermore, to do parameter optimization for base-isolation structures, a graphical approach is proposed by analyzing the relationship between the base shear ratio of a seismic base-isolation floor to non-seismic base-isolation one and frequency ratio-damping ratio, as well as the relationship between the seismic base-isolation floor displacement and frequency ratio-damping ratio. In addition, the influences of mode number and site classification on the seismic base-isolation structure and corresponding optimum parameters are investigated. It is demonstrated that the modified complex mode superposition design response spectrum method is more precise and more convenient to engineering applications for utilizing the damping reduction factors and the design response spectrum, and the proposed graphical approach for parameter optimization of seismic base-isolation structures is compendious and feasible.

유한 요소법을 이용한 대변위 압전 Bimorph 설계 (Design of Large Displacement Piezoelectric Bimorphs with Finite Element Method)

  • 임종인;노용래;김선욱
    • 한국세라믹학회지
    • /
    • 제34권4호
    • /
    • pp.337-342
    • /
    • 1997
  • This paper describes the design and evaluation of new type piezoelectric bimorph actuator that shows much large mechanical response than those conventional types. The bimorph actuator has modified structure combined with the multilayer actuator(MLA) and the composite multilayer actuator called "Moonie". The design and performancean alysis of bimorph actuator are carried out with Finite Element Method (FEM). Theoretical calculation results show that the generating force and displacement of Moonie-modified bimorph actuator can be improved by about 130% and 150%, respectively. The overshooting and ringing phenomena of the bimorph can be effectively restrained by the pseudo step electric field having a rising time coincied with a period of the fundamental vibration mode of the bimorph.e bimorph.

  • PDF

진동대시험에 근거한 댐의 내진설계시 해석 방법의 비교 (The Comparision of Analysis Methods in dynamic Design of Dam based on Shaking Table tests)

  • 황성춘;오병현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.732-737
    • /
    • 2005
  • This paper performed pseudo static analysis and dynamic analysis for CFRD and evaluated reliability with the results of Shaking Table Test. The Seismic coefficient method, modified seismic coefficient method, Newmark method of Pseudo static analysis and frequency domain response analysis, time domain history analysis of dynamic analysis were used. The analysis results were differ between analysis method, but the trends of acceleration and displacement were good agreement with the results of shaking table test.

  • PDF

고차전단변형과 대처짐을 고려한 복합적층판의 저속충격거동 해석 (Low-Velocity Impact Response Analysis of Composite Laminates Considering Higher Order Shear Deformation and Large Deflection)

  • 최익현;홍창선
    • 대한기계학회논문집
    • /
    • 제17권12호
    • /
    • pp.2982-2994
    • /
    • 1993
  • Low-velocity impact responses of composite laminates are investigated using the finite element method based on various theories. In two-dimensional nonlinear analysis, a displacement field considering higher order shear deformation and large deflection of the laminate is assumed and a finite element formulation is developed using a C$^{o}$-continuous 9-node plate element. Also, three-dimensional linear analysis based on the infinitesimal strain-displacement assumptions is performed using 8-node brick elements with incompatible modes. A modified Hertzian contact law is incorporated into the finite element program to evaluate the impact force. In the time integration, the Newmark constant acceleration algorithm is used in conjuction with successive iterations within each time step. Numerical results from static analysis as well as the impact response analysis are presented including impact force histories, deflections, strains in the laminate. Impact responses according to two typical low-velocity impact conditions are compared each other.

Nonlinear oscillations of a composite microbeam reinforced with carbon nanotube based on the modified couple stress theory

  • M., Alimoradzadeh;S.D., Akbas
    • Coupled systems mechanics
    • /
    • 제11권6호
    • /
    • pp.485-504
    • /
    • 2022
  • This paper presents nonlinear oscillations of a carbon nanotube reinforced composite beam subjected to lateral harmonic load with damping effect based on the modified couple stress theory. As reinforcing phase, three different types of single walled carbon nanotubes distribution are considered through the thickness in polymeric matrix. The non-linear strain-displacement relationship is considered in the von Kármán nonlinearity. The governing nonlinear dynamic equation is derived with using of Hamilton's principle.The Galerkin's decomposition technique is utilized to discretize the governing nonlinear partial differential equation to nonlinear ordinary differential equation and then is solved by using of multiple time scale method. The frequency response equation and the forced vibration response of the system are obtained. Effects of patterns of reinforcement, volume fraction, excitation force and the length scale parameter on the nonlinear responses of the carbon nanotube reinforced composite beam are investigated.