• 제목/요약/키워드: modified base materials

검색결과 84건 처리시간 0.026초

Effects of incorporation of 2.5 and 5 wt% TiO2 nanotubes on fracture toughness, flexural strength, and microhardness of denture base poly methyl methacrylate (PMMA)

  • Naji, Sahar Abdulrazzaq;Behroozibakhsh, Marjan;Kashi, Tahereh Sadat Jafarzadeh;Eslami, Hossein;Masaeli, Reza;Mahgoli, Hosseinali;Tahriri, Mohammadreza;Lahiji, Mehrsima Ghavvami;Rakhshan, Vahid
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권2호
    • /
    • pp.113-121
    • /
    • 2018
  • PURPOSE. The aim of this preliminary study was to investigate, for the first time, the effects of addition of titania nanotubes ($n-TiO_2$) to poly methyl methacrylate (PMMA) on mechanical properties of PMMA denture base. MATERIALS AND METHODS. $TiO_2$ nanotubes were prepared using alkaline hydrothermal process. Obtained nanotubes were assessed using FESEM-EDX, XRD, and FT-IR. For 3 experiments of this study (fracture toughness, three-point bending flexural strength, and Vickers microhardness), 135 specimens were prepared according to ISO 20795-1:2013 (n of each experiment=45). For each experiment, PMMA was mixed with 0% (control), 2.5 wt%, and 5 wt% nanotubes. From each $TiO_2$:PMMA ratio, 15 specimens were fabricated for each experiment. Effects of $n-TiO_2$ addition on 3 mechanical properties were assessed using Pearson, ANOVA, and Tukey tests. RESULTS. SEM images of $n-TiO_2$ exhibited the presence of elongated tubular structures. The XRD pattern of synthesized $n-TiO_2$ represented the anatase crystal phase of $TiO_2$. Moderate to very strong significant positive correlations were observed between the concentration of $n-TiO_2$ and each of the 3 physicomechanical properties of PMMA (Pearson's P value ${\leq}.001$, correlation coefficient ranging between 0.5 and 0.9). Flexural strength and hardness values of specimens modified with both 2.5 and 5 wt% $n-TiO_2$ were significantly higher than those of control ($P{\leq}.001$). Fracture toughness of samples reinforced with 5 wt% $n-TiO_2$ (but not those of 2.5% $n-TiO_2$) was higher than control (P=.002). CONCLUSION. Titania nanotubes were successfully introduced for the first time as a means of enhancing the hardness, flexural strength, and fracture toughness of denture base PMMA.

PCR에 의한 수입식품의 유전자재조합 원료 분석 및 모니터링 (Monitoring and Analysis of Genetically Modified Ingredients of Imported Foods by PCR)

  • 김희연;박용춘;노혜림;조준일;김은정;남혜선;이진경;이진하;강윤숙;이종옥
    • 한국식품과학회지
    • /
    • 제38권5호
    • /
    • pp.605-608
    • /
    • 2006
  • 2004년 9월부터 12월까지 경인지역으로 수입되는 원료농산물 및 가공식품에 대하여 유전자재조합성분 함유여부 및 유전자재조합식품 표시제 이행실태를 확인하기 위하여 모니터링을 실시하였다. 분석방법은 유전자재조합식품 검사지침에 따랐으며, 콩류가공품(원료콩 포함) 64건, 옥수수 가공품(원료 옥수수 포함) 52건, 콩 및 옥수수 함유식품 4건 등 총 120 건을 분석대상으로 하였다. 분석결과 콩을 원료로 하는 콩류가공품 1건, 콩 및 옥수수 혼합 가공식품 1건 등 총 2건에서 유전자재조합 콩인 round-ready soybean 성분을 확인 할 수 있었다. 그러나 유전자재조합 옥수수 (Bt11, GA21, T25, E176, Mon810)를 포함하는 가공식품은 확인되지 않았다. 그리고 콩 가공품 3건, 옥수수가공품 8건, 콩 및 옥수수가공품 1건 등 총 12건에서는 내재성유전자를 확인할 수 없어 검사불능으로 판정되었다. 유전자재조합성분이 확인된 시료 2건은 구분유통증명서를 구비하고 있었으며, 검사불능 시료의 경우 대부분 옥수수전분을 포함하는 제품으로 확인되었고, 추출된 유전자를 양상을 분석한 결과 크기가 300 bp 이하로 절단되어 PCR법을 이용한 분석 시 주형유전자로 사용하기에는 충분 하지 않은 것으로 판단된다.

연마시 여러 가지 수복재와 이장재의 사용에 따른 치수내 온도변화 (TEMPERATURE CHANGES IN THE PULP ACCORDING TO VAR10US RESTORATIVE MATERIALS AND BASES DURING POLISHING PROCEDURE)

  • 백병주;이두철;김미라;김재곤
    • 대한소아치과학회지
    • /
    • 제27권3호
    • /
    • pp.410-418
    • /
    • 2000
  • 치아수복시 마무리 과정에서의 연마는 수복물의 수명 및 심미성을 결정하는 중요한 과정으로서 연마시 마찰열의 발생으로 인하여 치수에 위해작용을 줄 수 있으므로 주의를 하여야 한다. 여러 가지 수복 재료를 연마하는 동안 치수내에서 발생하는 열의 변화를 수복물 종류, 이장재 종류, 잔존 상아질의 두께, 연마 시간의 차이에 따라 조사하고자 발치된 구치에 수복물을 충전한 후 aluminum-oxide coated disc를 이용하여 연마하는 과정에서 thermocouple을 이용하여 치수내 온도값을 측정하였으며, 이에 대한 통계적 분석을 시행하여 다음과 같은 결과를 얻었다. 모든 경우에서 연마 시간이 증가함에 따라 치수내 온도가 증가하였으며, 아말감 연마시 다른 수복 재료에 비해 큰 온도 증가치를 보였으나 composite resin, glass ionomer cement, 그리고 compomer에서는 연마에 따른 온도 변화차가 관찰되지 않았다. 아말감 하방에 이장재를 사용한 경우에 이장재를 사용하지 않았을 경우에 비해 온도 증가량이 적었으며, 다른 수복재에서는 이장재 사용여부에 따른 온도 증가량의 차이는 존재하지 않았다. 본 실험에서 사용된 이장재 중 glass ionomer cement와 zinc phosphate cement에 비해 zinc oxide eugenol cement의 열 차단 효과가 가장 작았다. 수복물에 간헐적인 연마를 시행한 경우, 지속적인 연마를 시행한 경우에 비해 온도 증가량이 작았으며, 아말감 하방의 잔존 상아질의 두께가 감소하면 온도 증가량이 더 커졌으나, 다른 세 종류의 수복재에서는 잔존 상아질의 두께에 따른 차이가 발생하지 않았다.

  • PDF

에폭시수지계 중성자 차폐재 제조 및 특성 (Fabrication and Characteristics of Epoxy Resin-Type Based Neutron Shielding Materials)

  • 조수행;김익수;도재범;노성기;박현수
    • 한국재료학회지
    • /
    • 제8권5호
    • /
    • pp.457-463
    • /
    • 1998
  • 방사선물질의 수송 및 저장용기 등에 사용되는 에폭시수지계 중섣자 차폐재, KNS-201, KNS-301 및 KNS-601을 제조하였다. 기본물질은 개질 및 수소 첨가된 비스페놀 A형 그리고 노블락형 에폭시수지이며, 첨가제로는 수산화알루미늄 및 탄화붕소이다. 이들 중성자 차폐재들의 열적 및 역학적 성질 및 재방사선성 등을 평가하기 위해 여러 특성시험을 행하였다. 조사된 제반 특성들은 열분해온도;$257~280^{\circ}C$, 열전도도;0.95~1.14W/m.K, 열팽창계수 ;0.77~1.26x$10^{-6}$$^{\circ}$$C^{-1}$, 연소특성;$800^{\circ}C$이하, 평균연소시간;5초 이하, 평균연소길이 ;5mm 이하, 인장강도;2.5~3.2Kg/$\textrm{mm}^2$,압축강도:13.2~15.2kg/$\textrm{mm}^2$ 굴곡강도:5.2~604Kg/$\textrm{mm}^2$ 등을 나타냈다. 전반적으로 개발된 중성자 차폐재들의 관련 특성들이 외국에서 사용되는 중성자 차폐재, NS-4-RF보다 우수한 것으로 나타났다. 또한 KNS-601의 내방사선성이 KNS-201과 KNS-301보다 우수한 것으로 나타났다. 또한 KNS-601의 내방사선이 KNS-201과 KNS-301보다 우수한 것으로 나타났다.

  • PDF

탄성 의치상 이장재의 표면 특성 및 적합도에 관한 비교 실험 연구 (A COMPARATIVE EXPERIMENTAL STUDY ON THE SURFACE CHARACTERISTICS AND THE FITTNESS OF THE RESILIENT DENTURE LINES)

  • 이수백;윤창근
    • 대한치과보철학회지
    • /
    • 제25권1호
    • /
    • pp.137-154
    • /
    • 1987
  • The purpose of this investigation was to determine the surface characteristics and the fittness of the resilienct denture lines. Firstly, 50 samples ($2.0{\times}4.0{\times}0.3cm$) of 4 resilient lining materials (Molloplast B, Coe Super Soft, Mollosil, Coe Soft) and one conventional acrylic resin (K-33) were processed according to manufacture's direction and examined the surface characteristics by use of surface profilometer and scanning electron microscopy. Secondly, 50 identical maxillary casts were made and 50 denture bases were pro cessed of 4 resilient liners and one conventional acrylic resin and they were stored in the room temperature water bath of 1 day, 1 week, 2 weeks, 3 weeks, 4 weeks and 6 weeks after processing. The original casts were cut away 1 cm from the posterior border, the dentures were seated, and the existing space was measured at seven regions according to the storage time by use of the modified thickness guage. The results were as follows. 1. Surface roughness (Rz) were $4.00{\pm}1.60{\mu}m$ in Mollosil, $4.47{\pm}2.21{\mu}m$ in Molloplast B, $7.46{\pm}1.70{\mu}m$ in Coe Super Soft, $12.70{\pm}2.39{\mu}m$ in Coe Soft and $13.03{\pm}2.74{\mu}m$ in K-33. 2. The generation of porosity was far more active in cold-cured resilient liners (Coe Soft and Mollosil) than in heat cured resilient liners (Molloplast B, and Coe Super Soft) and conventional heat cured resin (K-33). 3. Denture bases showed the greatest discrepancy at the central portion of the posterior palatal border and the intimate contact in the buccal flange regardless of denture base materials. 4. When the denture bases were stored in the water for 1 day and 6 weeks after processing, the sum of average discrepancies in the seven regions of the denture base was the greatest in K-33 followed by Molloplast B, Mollosil, Coe Soft and Coe Super Soft but followed by Coe Soft, Molloplast B, Mollosil, Coe Super Soft in that order respectively. 5. There was not a significant difference (p>0.05) in Coe Super Soft, K-33 but there was a significant difference (P<0.01) in Molloplast B, Mollosil, Coe Soft at the amount of dimensional changes according to the storage time.

  • PDF

Evaluation of effect of galvanic corrosion between nickel-chromium metal and titanium on ion release and cell toxicity

  • Lee, Jung-Jin;Song, Kwang-Yeob;Ahn, Seung-Geun;Choi, Jung-Yun;Seo, Jae-Min;Park, Ju-Mi
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권2호
    • /
    • pp.172-177
    • /
    • 2015
  • PURPOSE. The purpose of this study was to evaluate cell toxicity due to ion release caused by galvanic corrosion as a result of contact between base metal and titanium. MATERIALS AND METHODS. It was hypothesized that Nickel (Ni)-Chromium (Cr) alloys with different compositions possess different corrosion resistances when contacted with titanium abutment, and therefore in this study, specimens ($10{\times}10{\times}1.5mm$) were fabricated using commercial pure titanium and 3 different types of Ni-Cr alloys (T3, Tilite, Bella bond plus) commonly used for metal ceramic restorations. The specimens were divided into 6 groups according to the composition of Ni-Cr alloy and contact with titanium. The experimental groups were in direct contact with titanium and the control groups were not. After the samples were immersed in the culture medium - Dulbecco's modified Eagle's medium[DMEM] for 48 hours, the released metal ions were detected using inductively coupled plasma mass spectrometer (ICP-MS) and analyzed by the Kruskal-Wallis and Mann-Whitney test (P<.05). Mouse L-929 fibroblast cells were used for cell toxicity evaluation. The cell toxicity of specimens was measured by the 3-{4,5-dimethylthiazol-2yl}-2,5-diphenyltetrazolium bromide (MTT) test. Results of MTT assay were statistically analyzed by the two-way ANOVA test (P<.05). Post-hoc multiple comparisons were conducted using Tukey's tests. RESULTS. The amount of metal ions released by galvanic corrosion due to contact between the base metal alloy and titanium was increased in all of the specimens. In the cytotoxicity test, the two-way ANOVA showed a significant effect of the alloy type and galvanic corrosion for cytotoxicity (P<.001). The relative cell growth rate (RGR) was decreased further on the groups in contact with titanium (P<.05). CONCLUSION. The release of metal ions was increased by galvanic corrosion due to contact between base metal and titanium, and it can cause adverse effects on the tissue around the implant by inducing cytotoxicity.

강화형 글라스 아이오노머 합착용 시멘트의 접합강도 및 변연누출에 대한 연구 (COMPARISON OF SHEAR BOND STRENGTH AND MARGINAL LEAKAGE OF RESIN MODIFIED GLASS IONOMER CEMENTS)

  • 박혜양;오남식;이근우;이호용
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.647-661
    • /
    • 1997
  • The resin modified glass ionomer cements(RMGICs) have been used for years since 1989. Recently it has been developed for luting of fixed restorations. To evaluate the bond strength and marginal leakage of RMGICs for luting usage, the 80 extracted human molars which had uniform area of exposed dentin were cemented with 3 types of RMGICs(Fuji Duet, Advance, Vitremer), a conventional Glass Ionomer Cement(GIC-Fuji I), and a resin cement (Panavia 21) to base metal alloy(Ni-Cr-Be). After thermocycling the specimens were immersed in basic fuschin dye for measuring marginal leakage. The shear bond strength was measured with Instron and the maximum dye penetration was measured to 0.1mm. The types of fractured patterns were determined with stereoscope(${\times}7.5$). The results are as follows. 1. The difference between 3 RMGICs and a conventional GIC in shear bond strength was not statistically significant. It seemed that RMGICs had lower shear bond strength than resin cement. (p<0.01) 2. The mean scores of marginal leakage had no significant difference between the resin cement and 3 RMGICs but it was much higher in conventional GIC than the RMGICs (p<0.05) 3. It was determined that the manufacturer and the methods of dentin pretreatment determined the pattern of fracture surfaces and the frequency of adhesive failure between teeth and 3 RMGICs standed as in following order - Vitremer, Advance, Fuji Duet. (p<0. 01) When the fracture pattern was analyzed, it could be said that the materials and the method of dentin pretreatment have much effect on bonding states. This means that the dentin bonding agents should be improved. But the limited products in this experiment can not evaluate the physical properties of the entire RMGICs. Therefore a further study which can evaluate various RMGICs should be in progress to develope better cements.

  • PDF

구치부 제2급 와동에서 고흐름성 복합레진을 이용한 적층 충전술식의 미세누출에 미치는 영향 (THE EFFECT OF SANDWICH TECHNIQUE USING FLOWABLE COMPOSITE RESIN BASE ON THE MICROLEAKAGEIN CLASS II CAVITIES OF MOLAR)

  • 이강;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제27권5호
    • /
    • pp.502-514
    • /
    • 2002
  • The aim of this study was to evaluate the marginal adaptation of direct class II sandwich restoration with packable composites(P-60), resin modified glass ionomer cement(Fuji-II LC), flowable compomer(Dyract Flow), flowable composites(Filtek Flow) in comparison with total bond restorations. In addition, for sandwich restorations, influence of different sandwich techniques was also evaluated. Large butt-joint box typed class II cavites with cervical margins 1mm below the cemento-enamel junction were cut into 70 extracted human molars. The cavities(7 groups, n=10) were filled using a closed/open sandwich restoration or total bond restoration technique with materials according to the manufacturer's recommandation using the single-component bonding agent for each system. Teeth were thermocycled 500 times between 5$^{\circ}C$ and 55$^{\circ}C$ with 30-second dwell time. The teeth were then coated with nail polish 1mm short of the restoration, placed in a 2% methylene blue for 24 hours, and sectioned with diamond wheel. Sections were examined with a stereoscope to determine the extent of microleakage. Dentine /Cementum margins were analyzed for microleakage on scale of 0(no leakage) to 4(entire axial wall) and interface between materials, on scale of 0(no leakage) to 3(axial wall). Results were evaluated with Kruskal Wallis Test, corrected for ties, to determine whether there were statistically significant differences among the seven groups. Pairs of groups were analyzed using the Student-Newman-Keuls Method and Dunn s Method. The results were as follows : 1. All groups showed some micoleakage in cervical portion. But there were no microleakage in interface between materials. 2. Closed sandwich restorations with Fuji-II LC and Filtek Flow had significantly lower leakage rating than total restorations with only P-60. However, open sandwich restorations with Dyract Flow showed significantly higher (P<0.05) 3. Closed sandwich restorations had significantly lower leakage rating than total restorations. However open sandwich restoration s showed significantly higher (P<0.05). 4. Sandwich restorations with Fuji-II LC were iou$.$or leakage than only P-60. Filtek Flow, Dyract Flow. But there were no statistically differences among the materials. From the results above, it could be concluded, closed sandwich restorations was effective in reducing microleakage of class II restorations. The best results showing the least microleakage were for the closed sandwich technique with Fuji-II LC and Filtek Flow.

고품질 재활용 아스팔트 혼합물의 현장적용성에 대한 연구 (A Study on the Field Application of Superior Recycled Pavement of the Waste Asphalt)

  • 김지원;천병식
    • 한국지반환경공학회 논문집
    • /
    • 제13권2호
    • /
    • pp.67-73
    • /
    • 2012
  • 폐아스콘은 순재료와 첨가제를 섞어 분쇄와 가열을 통하여 재활용될 수 있다. 본 연구에서는 고품질재생아스팔트(SRP)의 질을 향상시키기 위하여 Sasol 왁스와 폴리올레핀 탄성체를 이용하였다. 첨가제로써 중간층 및 표층용은 PG 70-22를 목표로 아스팔트량의 1.5%를 사용하였고, 중교통 표층용은 PG 76-22를 목표로 아스팔트량의 3% 개질제와 혼합물의 0.1%에 해당하는 셀룰로스 화이버를 첨가하였다. 두 혼합물은 마샬안정도시험, 간접인장강도시험, 잔류간접인장강도시험, 휠트래킹시험 등을 수행하였다. 시험결과는 KS F 2349와 GR F 4005의 기준을 만족하였으며, 고품질재생아스팔트는 중교통도로의 표층 및 기층재료로 사용이 적합하였다. 현재 약 13,000톤의 고품질재생아스팔트 혼합물이 서울 올림픽 도로에 현장시공 되었다.

Poly(ethylene Terephthalate) 필름의 표면모폴로지와 표면특성 (The Surface Morphology and Characteristics of Poly (ethylene Terephthalate) Film)

  • 강인숙;문미화;나종주
    • 한국의류학회지
    • /
    • 제34권11호
    • /
    • pp.1880-1888
    • /
    • 2010
  • This study was a preliminary investigation of the influence of surface characteristics of substrates on the detergency of particulate soil. A PET film was surface modified with NaOH and DMF for different times. The surface morphology of the film was scanned by AFM and the surface energies were calculated from the measured contact angles between several solutions and film based on a geometric mean and the Lewis acid base method. The surface morphology of the PET film treated with NaOH and DMF became more etched and swelled with an increased treatment time, respectively. The surface roughness and surface area of film treated with NaOH enlarged with increased treatment time. However, the coefficient of friction of film treated with NaOH and coefficient of friction, surface roughness, and surface area of film treated with DMF increased and then decreased with increased treatment time. The contact angle of film treated with DMF decreased with increased treatment time in water and surfactant solution; however, the effect of treatment time on the contact angle was different in both solutions for film treated with NaOH. By the treatment of PET film with NaOH and DMF, the polar group of the surface energy increased and the nonpolar group decreased; however, the change of total surface energy was not significant.