• 제목/요약/키워드: model transformer

검색결과 583건 처리시간 0.024초

Transformer Winding Modeling based on Multi-Conductor Transmission Line Model for Partial Discharge Study

  • Hosseini, Seyed Mohammad Hassan;Baravati, Peyman Rezaei
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.154-161
    • /
    • 2014
  • To study and locate partial discharge(PD) and analyze the transient state of power transformer, there is a need for a high frequency model of transformer winding and calculation of its parameters. Due to the high frequency nature of partial discharge phenomenon, there is a need for an accurate model for this frequency range. To attain this goal, a Multi-Conductor Transmission Line (MTL) model is used in this paper for modeling this transformer winding. In order that the MTL model can properly simulate the transformer behavior within a frequency range it is required that its parameters be accurately calculated. In this paper, all the basic parameters of this model are calculated by the use of Finite Element Method (FEM) for a 20kV winding of a distribution transformer. The comparison of the results obtained from this model with the obtained shape of the waves by the application of PD pulse to the winding in laboratory environment shows the validity and accuracy of this model.

동력분산형 고속철도용 변압기 설계 및 자계해석 모델 (A Transformer Design and Magnetic Analysis Model for the High-Speed EMU)

  • 박병건;현동석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집 특별세미나,특별/일반세션
    • /
    • pp.517-524
    • /
    • 2009
  • This paper proposes a magnetic analysis model and design method of transformer for the high-speed EMU. It has a many part of the consideration in design because the transformer in high-speed train has the multiple output. Also the output characteristic, weight, and size of transformer is an important factor. This research proposes a design method of transformer in high-speed EMU. And it is easy to design by using the analysis model in design the transformer through the establishment of the magnetic analysis model.

  • PDF

효율적인 Transformer 모델 경량화를 위한 구조화된 프루닝 (Structured Pruning for Efficient Transformer Model compression)

  • 류은지;이영주
    • 반도체공학회 논문지
    • /
    • 제1권1호
    • /
    • pp.23-30
    • /
    • 2023
  • 최근 거대 IT 기업들의 Generative AI 기술 개발로 Transformer 모델의 규모가 조 단위를 넘어가며 기하급수적으로 증가하고 있다. 이러한 AI 서비스를 지속적으로 가능케 하기 위해선 모델 경량화가 필수적이다. 본 논문에서는 하드웨어 친화적으로 구조화된(structured) 프루닝 패턴을 찾아 Transformer 모델의 경량화 방법을 제안한다. 이는 모델 알고리즘의 특성을 살려 압축을 진행하기 때문에 모델의 크기는 줄어들면서 성능은 최대한 유지할 수 있다. 실험에 따르면 GPT2 와 BERT 언어 모델을 프루닝할 때 제안하는 구조화된 프루닝 기법은 희소성이 높은 영역에서도 미세 조정된(fine-grained) 프루닝과 거의 흡사한 성능을 보여준다. 이 접근 방식은 미세 조정된 프루닝 대비 0.003%의 정확도 손실로 모델매개 변수를 80% 줄이고 구조화된 형태로 하드웨어 가속화를 진행할 수 있다.

변압기를 모델링한 두 개의 동심 원형 실린더 내에서 난류 자연대류의 수치해석 (Numerical analysis of turbulent natural convection in a cylindrical transformer enclosure)

  • 오건제;하수석
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.157-166
    • /
    • 1999
  • Numerical calculations of turbulent natural convection in an enclosure of the 20 kYA oil-immersed transformer model are presented. The transformer is modelled as two concentric cylinders with different heights and diameters. The thermal boundary layers are well represented in the temperature distributions along the wall of the transformer model. The flow stratification between the hot and cold walls can not be seen in the transformer model. The turbulence eddy viscosity has its maximum at the center of the core and its maximum values at the top of the core are larger than those at the bottom of the core.

  • PDF

복합격자 생성기법을 이용한 전력용 변압기의 2차원 온도분포 해석 (Analysis of Temperture Distribution in 2-D Power Transformer Using Hybrid Mesh Model)

  • 민경조;김중경;한성진;주수원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.993-995
    • /
    • 2005
  • Recently, the efficiency of power transformer is improved as well as the size is becoming smaller. So, it is very important that temperature characteristics of the transformer should be estimated and predicted precisely. This paper deals with the temperature distribution of power transformer by simplified 2-D hybrid mesh model. The temperature distribution of model transformer was obtained by CFD algorithm considering natural convection. Heat sources are calculated first by magnetic field analysis based on F.E.M. and are usedas the input data for thermal field problem based on computational fluid dynamics(CFD) algorithm. The calculated temperature distribution of the simplified 2-D power transformer model shows good results in accuracy as well as in computing time.

  • PDF

LVI 시험기의 개발과 변압기 권선변형 분석의 적용에 관한 연구 (A study on the development of LVI tester and applying the winding deformation of transformers with this tester)

  • 조국희;김광화
    • 조명전기설비학회논문지
    • /
    • 제15권6호
    • /
    • pp.58-64
    • /
    • 2001
  • 본 논문은 LVI시험기 및 모델 변압기의 설계와 제작에 관하여 기술하였다. 이들을 이용하여 LVI 시험 분석기 술을 개발하였다. LVI시험기는 본테, 터미널 박스 및 케이블로 구성하였고, ANSI규격에서 요구하는 출력특성을 갖는 것으로 평가되었다. 모델변압기는 탭들을 만들어 변압기의 권선변형 모델을 만들 수 있도록 하였고, LVI시험기로써 실험을 실시하여 LVI시험분석 기술에 관하여 논하였다.

  • PDF

틸팅열차 주변압기 냉각시스템의 온도설정알고리즘 (Temperature Setpoint Algorithm for the Cooling System of a Tilting Train Main Transformer)

  • 한도영;노희전;원재영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.387-392
    • /
    • 2008
  • In order to improve the efficiency of the main transformer in a tilting train, the optimal operation of a cooling system is necessary. For the development of the optimal control algorithm of a cooling system, the mathematical model of a main transformer cooling system was developed. This includes the dynamic model of a main transformer, an oil pump, an oil cooler and a blower. The system algorithm of a cooling system, which consists of the temperature setpoint algorithm and the temperature control algorithm, was developed. Optimal oil temperatures of the inlet and the outlet of the main transformer were obtained by considering the total electric power consumption of the system. The oil inlet temperature was controlled by the blower and the oil outlet temperature was controlled by the oil pump. A simulation program was developed by using the mathematical model and the system algorithm. Simulation results showed that the system algorithm developed from this study may be effectively used to control the main transformer cooling system in a tilting train.

  • PDF

Simulink를 이용한 교류 급전변전소의 스코트변압기 모델링 (Scott Transformer Modeling using Simulink on the AC Substation)

  • 김태근;박영;이종우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.2317-2322
    • /
    • 2011
  • In three-phase power, when the power is supplied to the single phase load, there is the unbalance of load in the three-phase power. So the scott transformer is used in the power system to supply a single phase load in three-phase power without the unbalance of loads. Especially, the scott transformer is used in the AC substation of electric railroad. Two single phase transformers are combined by T-wiring in the scott transformer. So, two single phase voltage is provided by differing $90^{\circ}$ phase in three-phase power. The selection of related equipment and correction of protective relay are not easy from characteristic of the scott transformer when shunt and ground faults occur. In this paper, electric model of the scott transformer is suggested and the current of the scott transformer in shunt and ground faults is analyzed. Also, the scott transformer model is demonstrated by using Sinulink.

  • PDF

전기철도의 교류 급전변전소에서 PSIM을 이용한 스코트변압기 모델링 (Scott Transformer Modeling using PSIM on the AC Substation in the Elect ric Railroad)

  • 김성대;최규형
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1892-1897
    • /
    • 2010
  • In three-phase power, when the power is supplied to the single phase load, there is the unbalance of load in the three-phase power. So the scott transformer is used in the power system to supply a single phase load in three-phase power without the unbalance of loads. Especially, the scott transformer is used in the AC substation of electric railroad. Two single phase transformers are combined by T-wiring in the scott transformer. So, two single phase voltage is provided by differing $90^{\circ}$ phase in three-phase power. The selection of related equipment and correction of protective relay are not easy from characteristic of the scott transformer when shunt and ground faults occur. PSIM(Power Electronics Simulator) is optimal simulation software in field of the power electronics and provide the simple and convenient user interface. In this paper, electric model of the scott transformer is suggested and the current of the scott transformer in shunt and ground faults is analyzed. Also, the scott transformer model is demonstrated by using PSIM.

  • PDF

Development of CNN-Transformer Hybrid Model for Odor Analysis

  • Kyu-Ha Kim;Sang-Hyun Lee
    • International Journal of Advanced Culture Technology
    • /
    • 제11권3호
    • /
    • pp.297-301
    • /
    • 2023
  • The study identified the various causes of odor problems, the discomfort they cause, and the importance of the public health and environmental issues associated with them. To solve the odor problem, you must identify the cause and perform an accurate analysis. Therefore, we proposed a CNN-Transformer hybrid model (CTHM) that combines CNN and Transformer and evaluated its performance. It was evaluated using a dataset consisting of 120,000 odor samples, and experimental results showed that CTHM achieved an accuracy of 93.000%, a precision of 92.553%, a recall of 94.167%, an F1 score of 92.880%, and an RMSE of 0.276. Our results showed that CTHM was suitable for odor analysis and had excellent prediction performance. Utilization of this model is expected to help address odor problems and alleviate public health and environmental concerns.