• 제목/요약/키워드: mode volume

검색결과 595건 처리시간 0.026초

일정체적 변단면 기둥의 자유진동 (Free Vibrations of Tapered Columns with Constant Volume)

  • 이병구;이태은;최규문;송주한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.417-422
    • /
    • 2002
  • The main purpose of this paper is to determine the dynamic optimal shapes of tapered column with constant volume. The linear, parabolic and sinusoidal tapers with the regular polygon cross-section are considered, whose material volume and span length are always held constant. The ordinary differential equation including the effect of axial load is applied to calculate the natural frequencies. The Runge-Kutta method and Regula-Falsi methods are used to integrate the differential equation and compute the frequencies, respectively. Then the dynamic optimal shape whose lowest natural frequency is highest is determined by reading the critical value of the frequency versus section ratio curve plotted by the frequency data. In the numerical examples, the tapered columns are analysed and the numerical result of this study are shown in table and figures.

  • PDF

Averaged strain energy density to assess mixed mode I/III fracture of U-notched GPPS samples

  • Saboori, Behnam;Torabi, A.R.;Berto, F.;Razavi, S.M.J.
    • Structural Engineering and Mechanics
    • /
    • 제65권6호
    • /
    • pp.699-706
    • /
    • 2018
  • In the present contribution, fracture resistance of U-notched GPPS members under mixed mode I/III loading conditions is assessed by using the Averaged Strain Energy Density (ASED) criterion. This criterion has been founded based on the ASED parameter averaged over a well-defined control volume embracing the notch edge. The validation of the theoretical criterion predictions is evaluated through comparing with the results of a series of mixed mode I/III fracture tests conducted on rectangular-shaped GPPS specimens weakened by a single edge U-notch. A recently developed apparatus for mixed mode I/III fracture experiments is employed for measuring the fracture loads of the specimens. The test samples are fabricated with different notch tip radii with the aim of evaluating the influence of this major feature of the U-notched components on the mixed mode I/III fracture behavior. It is shown that the onset of brittle fracture in U-notched GPPS specimens under various combinations of tension and out-of-plane shear can well be predicted by means of the ASED criterion.

ISG 시스템용 고효율 양방향 DC-DC 컨버터의 설계 및 자율적이며 끊김없는 모드전환을 위한 제어전략 (Design and Control Strategy for Autonomous and Seamless Mode Transition of High Efficiency Bidirectional DC-DC Converter for ISG Systems)

  • 박준성;권민호;최세완
    • 전력전자학회논문지
    • /
    • 제21권1호
    • /
    • pp.19-26
    • /
    • 2016
  • In this study, a bidirectional DC-DC converter for idle stop and go (ISG) is developed to reduce fuel consumption. A three-phase non-isolated half-bridge converter is selected through a design method by considering efficiency and volume. According to the state of charge of the batteries at both the low-voltage and high-voltage sides, buck mode, which charges a low-voltage battery from the generated motor energy, and boost mode, which provides power to the motor from the low- and high-voltage battery sides, are required in the ISG system. Hence, an autonomous and seamless bidirectional control method using a variable current limiter is proposed for mode change. A 1.8 kW engineering sample of the proposed converter has been built and tested to verify the validity of the proposed concept. The maximum efficiencies, including gate driver and control circuit losses, are 96.4% in charging mode and 96.1% in discharging mode.

70 kW 이하 가정용 가스보일러 에너지소비효율 실험방법 개발 (A Development of Test Method on the Energy Consumption Efficiency of Domestic Gas Boiler below 70 kW)

  • 박찬일;김래현
    • 에너지공학
    • /
    • 제25권3호
    • /
    • pp.73-82
    • /
    • 2016
  • 표시가스 소비량이 70 kW 이하인 가정용 가스보일러에 대하여 여러 가지 운전조건하의 에너지 소비효율 측정에 대해 고찰하였다. 실제 운전상태와 유사한 실험조건에서 행한 에너지 효율실험 결과를 국내의 효율등급표시 실험방법 결과와 비교 분석하였다. 실험에 사용된 가정용가스보일러는 일반보일러와 콘덴싱 보일러 각 1개씩이며, 각각의 보일러에 대하여 네 가지 조건으로 실험하였다. 실험종류를 구분하면 실험실 모드와 실제 가동모드로 나누고, 각각의 모드별로 최대가스소비량 상태와 소비자판매 상태로 나누어 적용하였다. 효율실험을 위해 사용하는 장비는 KS 표준과 유럽의 EN 규격 등 가스보일러 관련 규격에서 제시하는 실험장치의 기능을 다하면서, 여러 가지 측정 인자를 지속적으로 축적, 기록 및 저장할 수 있는 장치로 하였다. 측정 대상 인자들은 유량(가스, 물), 온도(실험실, 난방공급수, 난방환수, 배기가스), 압력(가스미터 내부, 가스보일러 입구, 대기압) 등이다. 위 네 가지 모드의 실험결과 에너지소비효율은 실험실 상태(보일러의 안정화 상태로 실험 시작)로 실험할 때가 실제 소비자가 사용하는 패턴으로 실험할 때 보다 일반보일러의 경우 약 10 %, 콘덴싱 보일러의 경우 약 20% 높은 소비효율로 측정되었다. 에너지소비효율등급을 부여하는 정부 고시의 효율실험방법도 본 연구에서 실시한 것과 같이 실제상황을 가정한 효율실험방법을 도입 운영할 필요가 있다.

NiAl/Ni 미세적층복합재료의 고속변형거동 (High Strain-rate Deformation Behavior of NiAl/Ni Micro-laminated Composites)

  • 김희연;김진영;정동석;;홍순형
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2004년도 춘계학술발표대회 논문집
    • /
    • pp.237-240
    • /
    • 2004
  • High strain-rate deformation behavior of NiAl/Ni micro-laminated composites was characterized by split hopkins on pressure bar(SHPB). When the strain rate increased, the compressive stress of micro-laminated composites were increased a little. When the intermetallic volume fraction increased, the compressive stress of micro-laminated composites increased linearly irrespective of strain rate. Absorbed energy during the quasi-static and SHPB tests was calculated from the integrated area of stress-strain curve. Absorbed energy of micro-laminated composites deviated from the linearity in terms of the intermetallic volume fraction but merged to the value of intermetallic as the strain rate increased. This was due to high tendency of intermetallic layer for the localization of shear deformation at high strain rate. Microstructure showing adibatic shear band(ASB) confirmed that the shear strain calculated from the misalignment angle of each layer increased and ASB width decreased when the intermetallic volume fraction. Simulation test impacted by tungsten heavy alloy cylinder resulted that the absorbed energies multiplied by damaged volume of micro-laminated composites were decreased as the intermetallic volume fraction increased. Fracture mode were changed from delamination to single fracture when the intermetallic volume fraction and this results were good matched with previous results[l] obtained from the fracture tests.

  • PDF

스카이라디오미터 관측을 통한 서울 상공 에어러솔의 광학적 특성 분석 (Analysis of Aerosol Optical Properties in Seoul Using Skyradiometer Observation)

  • 구자호;김준;김미진;조희구
    • 대기
    • /
    • 제17권4호
    • /
    • pp.407-420
    • /
    • 2007
  • Optical characteristics of aerosols in Seoul are investigated from the measurements of sky radiance by Skyradiometer at Yonsei University from December 2005 to November 2006. Aerosol optical depth (AOD) shows a maximum in June due to weak ventilation and particle growth by aging process and hygroscopic effect. Single scattering albedo (SSA) and Angstrom Exponent (AE) show the lowest value in spring due to the Asian dust. It is clear that coarse mode is dominant in spring and fine mode is dominant in summer from the volume size distribution measured in this study. The explanations on the changes of aerosol loadings are provided through the correlation between AOD and AE, while the pattern of wavelength dependency related to particle size is shown through the correlation between SSA and AE. Backward trajectory analysis by HYSPLIT provides information about origin of aerosol, which allows us to classify the case according to the source region and the path distance. Although the direction of backward trajectory traces back mostly to west, coarse mode particle is dominant in the case of long pathway and fine mode particle is dominant in the case of short pathway. This discrepancy is caused by the regional difference of emitted particles.

Bound Mode의 외중력파에 의한 항내 이상파 생성가능성에 대하여 (On the Feasibility of Freak Waves Formation within the Harbor Due to the Presence of Infra-Gravity Waves of Bound Mode Underlying the Ever-Present Swells)

  • 조용준;배정현
    • 한국해안·해양공학회논문집
    • /
    • 제31권1호
    • /
    • pp.17-27
    • /
    • 2019
  • Bound mode의 외중력파와 이로 인한 보강간섭이 이상파 생성 기작이라는 가설을 확인하기 위해 OpenFoam 기반 Tool box인 ihFoam과 Bi-spectrum에 기초한 수치모의를 수행하였다. 수치모의는 건설 과정에서 이상파가 관측된 삼척 LNG 생산기지 전용부두를 대상으로 수행되었으며, Bound mode의 외중력파는 Bi-spectrum에 기반하여 출현빈도가 높은 주기가 7초인 국지 풍성파와 11.4초인 너울의 difference interaction으로 생성하였다. 또한 비교를 위해 비선형 Cnoidal wave, linear wave를 대상으로 한 수치모의도 병행하여 수행하였다. 모의결과 N 계열 bound mode의 외중력파에 의해 삼척 LNG 생산기지 전용부두를 따라 진행되는 연파가 생성되며, 이상파는 전술한 연파와 남측 도류제로부터의 반사파가 더해져 출현하는 것으로 모의되었다.

전산화단층촬영 소아 흉부검사에서 관전압의 변화에 따른 화질변화에 관한 연구 (A Study on the Change of Image Quality According to the Change of Tube Voltage in Computed Tomography Pediatric Chest Examination)

  • 김구;김경립;성순기;곽종혁
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.503-508
    • /
    • 2019
  • 흉부 CT 검사의 스캔 기법의 하나인 VOLUME AXIAL MODE를 이용하여 관전압의 변화에 따라 진단적으로 가치가 높은 영상을 얻기 위하여 화질을 평가하고 적절한 관전압을 제시하고자 한다. CT 장비는 GE사의 Revolution(GE Healthcare, Wisconsin USA)모델을 이용하였으며, Phantom은 Pediatric Whole Body Phantom PBU-70을 사용하였다. Heart의 SNR 평균차이분석에서는 70 kvp에서 $-4.53{\pm}0.26$ 이었고 80 kvp는 $-3.34{\pm}0.18$ 이었으며 100 kvp는 $-1.87{\pm}0.15$이었고 70 kvp가 100kvp 보다 약 -2.66정도 SNR이 높았으며 통계적으로 유의하였다.(p<0.05) Lung의 SNR 평균차이분석에서는 70 kvp에서 $-78.20{\pm}4.16$이었고 80 kvp는 $-79.10{\pm}4.39$이었으며 100 kvp는 $-77.43{\pm}4.72$이었고 70 kvp가 100 kvp 보다 약 -0.77정도 SNR이 높았으며 통계적으로 유의하였다.(p<0.05). Lung의 CNR 평균차이분석에서는 70 kvp에서 $73.67{\pm}3.95$이었고 80 kvp는 $75.76{\pm}4.25$이었으며 100 kvp는 $75.57{\pm}4.62$이었고 80 kvp가 70 kvp 보다 약 20.9정도 CNR이 높았으며 통계적으로 유의하였다.(p<0.05) 관전압 100 kvp에서는 70 kvp와 80k vp를 비교 했을 때 심장 영상의 질을 유지하면서 SNR이 1에 가까웠다. 하지만 70 kvp와 80kvp에서는 SNR 차이가 없어 70 kvp 로 소아 흉부 CT 검사를 하여 방사선량을 줄일 수 있을 것이다. 반면에 CNR은 70 kvp에서 가장 1에 근사치를 나타냈었으며 80kvp와 100kvp에서는 차이가 없어 80 kvp로 소아 흉부 CT 검사를 하여 방사선량을 줄일 수 있을 것이다. 또한 Volume Axial mode 검사 시 0.3초의 짧은 scan time으로 검사 할 수 있어서 움직이거나 진정이 필요한 소아환자에게 유용할 것으로 사료된다.

CPAP 및 SIMV Mode하에서 Pressure Support 사용이 호흡역학에 미치는 효과 (The Effect of Pressure Support on Respiratory Mechanics in CPAP and SIMV)

  • 임채만;장재원;최강현;이상도;고윤석;김우성;김동순;김원동;박평환;최종무
    • Tuberculosis and Respiratory Diseases
    • /
    • 제42권3호
    • /
    • pp.351-360
    • /
    • 1995
  • 연구배경: 압력보조는 환자의 흡기시 정해진 양의 양압을 보조하여 상시호흡량을 증가시키거나, 호흡일을 경감시키는 목적으로 쓰이는 기계환기법으로 본 연구는 자발적 호흡이 허용되는 SIMV 및 CPAP 양식에서 PS를 사용할 경우 환자의 호흡역학상 어떤 차이가 있는지 알아보고자 하였다. 방법: 중환자실에 입원하여 호흡부전으로 기계환기중인 환자로 임상적으로 안정되었고 자발적 호흡횟수가 분당 12회 이상인 환자 14명을 대상으로, 먼저 CPAP(3 cm $H_2O$) 양식하에서 0, 5, 10 및 15 cm $H_2O$의 PS를 순서대로 적용하면서 CP-100 pulmonary monitor(Bicore, USA)를 이용하여 호흡역학 지수들을 측정하고 이어서 SIMV 양식으로 바꾸어 같은 방법으로 호흡역학 지수들을 측정하였다. 결과: 1) CPAP 및 SIMV 방식하에서 PS가 호흡역학에 미친 공통된 효과 CPAP 양식하에서 PS를 증가시킴에 따라 상시호흡량은 증가하였고, WOB과 PTP는 감소하였다. SIMV 방식하에서도 PS를 증가시킴에 따라 상시호흡량은 증가하였고, WOB과 PTP 역시 유의하게 감소하였다. 2) CPAP 및 SIMV 방식하에서 PS가 호흡역학에 미치는 효과의 차이 CPAP 방식하에서 PS를 증가시킴에 따라 분당호흡수는 유의한 변동이 없었고, $P_{0.1}$$T_1/T_{TOT}$은 유의하게 감소되었다. SIMV 방식하에서 PS를 증가시킴에 따라 분당호흡수는 유의하게 감소한 반면, $P_{0.1}$$T_1/T_{TOT}$은 유의한 변동이 없었다. 3) CPAP+PS 양식에서 SIMV 단독양식에서와 같은 상시호흡량을 얻는 상태에서의 호흡역학의 비교 동일 환자에서 CPAP+PS 양식으로 SIMV 단독양식에서의 상시호흡량이 얻어지는 상태에서 분당호흡수 WOB, $P_{0.1}$ 등에는 양 방식 간에 차이가 없었으나 PTP와 $T_1/T_{TOT}$은 CPAP+PS 양식이 유의하게 낮았다. 결론: 기계호흡에서 압력보조의 사용은 CPAP 및 SIMV 양식 모두에서 상시호흡량을 증가시키고, 환자의 호흡일, 호흡근 산소소모량 지수를 감소시켰으며, 분당호흡수의 감소는 SIMV 방식에서만 관찰되었고, 중추성호흡추진력의 감소와 호흡근의 지구력지수의 호전은 CPAP 방식에서만 관찰되었다. 한편 상시호흡량이 같은 수준에서의 CPAP+ PS 방법은 SIMV 법에 비해 호흡근의 일효율이 더 높고 호흡근의 지구력지수가 더 우수하였다. 따라서, 기계적환기 유지기나 이탈과정의 환자에서 압력보조의 겸용은 환자의 호흡역학 상태를 개선하는 것으로 사료된다.

  • PDF

기계 호흡 중 불안정한 호흡역학을 보인 환자에서 압력조절용적조정양식(Pressure-regulated Volume Control Mode)의 효용 (The Usefulness of Pressure-regulated Volume Control(PRVC) Mode in Mechanically Ventilated Patients with Unstable Respiratory Mechanics)

  • 손장원;고윤석;임채만;심태선;이종덕;이상도;김우성;김동순;김원동
    • Tuberculosis and Respiratory Diseases
    • /
    • 제44권6호
    • /
    • pp.1318-1325
    • /
    • 1997
  • 연구배경 : 일정한 분시 유지하면서도 기도압의 하나인 압력조절용적조정양식(PRVC)의 입상적 유용성에 대한 보고는 없었다. 본 연구는 호흡역학이 불안정한 환자에서 PRVC 양식이 원래의 개발 목적대로 압력 조절 양식에 비해 일호흡량을 일정하게 유지하면서 용적조절양식에 비해 기도압을 낮게 유지하는지를 관찰하였다. 연구방법 : 기계 호흡 중이며 활력징후의 안정을 보이는 환자 중 15분간 관찰 결과 VCV에서 최고 홉기압의 변이계수가 10이상으로 최고 홉기압의 변화가 심하거나, PCV에서 상시 호흡량의 변이계수가 10이상으로 일 호흡량의 변화가 심한 환자 8 명(남 : 녀=6 : 2, $56{\pm}26$세)를 대상으로 하여 일호흡량을 비슷한 유지하도록 VCV, PCV, PRVC 양식을 설정한 후 각 환기양식에서 15분간 일호흡량과 최고 흡기압을 관찰하였다. 결 과 : 1) 평균 일호흡량은 VCV에서 $431{\pm}102ml$, PCV에서 $417{\pm}99ml$, PRVC에서 $414{\pm}97ml$였으며 각 환기양식 간에 차이가 없었다. 2) 상시 호흡량의 변이계수는 VCV에서 $5.2{\pm}3.9%$, PCV에서 $15.2{\pm}7.5%$ PRVC에서 $19.3{\pm}10.0%$로 PCV와 PRVC에서 상시 호흡량의 변화가 심하였다(p<0.01). 3) 평균 최고 홉기압은 VCV에서 $31.0{\pm}6.9cm$ $H_2O$, PCV에서 $26.0{\pm}6.5cm$ $H_2O$, PRVC에서 $27.0{\pm}6.4cm$ $H_2O$로 PCV와 PRVC의 최고 흡기압의 VCV의 경우보다 낮게 유지되었다(p<0.01). 4) 최고 홉기압의 변이계수는 VCV에서 $13.9{\pm}3.7%$, PCV에서 $4.9{\pm}2.6%$, PRVC에서 $12.2{\pm}7.0%$로 VCV와 PRVC에서 최고 홉기압의 변동이 심하였다(p<0.01). 결 론 : PRVC 양식은 호흡역학이 불안정한 환자에서는 VCV에 비해 평균 최고 홉기압은 낮게 유지하였으나 최고 흡기압의 변동이 심하였고, PCV에 비해 상시 호흡량의 변동이 심하여 이중조절환기양식 본래의 목적을 달성하기 어려울 것으로 사료된다.

  • PDF