• Title/Summary/Keyword: mode volume

Search Result 595, Processing Time 0.031 seconds

Critical Conduction Mode BOOST Type Solar Array Regulator (임계모드 부스트형 태양전력 조절기)

  • Yang, JeongHwan;Ryu, SangBurm;Yun, SeokTeak
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.3
    • /
    • pp.86-90
    • /
    • 2014
  • A DC-DC Converter operates in CCM(Continuous Coundcution Mode), DCM(Discontinuous Conduction Mode), CRM(Critical Conduction Mode). The CRM is boundary between CCM and DCM. If a DC-DC converter is designed to operate in CRM, its inductor volume can decrease and power loss which caused by switch and diode can decrease. In this paper, the DC-DC converter which operates in CRM is applied to a solar array regulator(SAR) for the satellite. The switching frequency of the CRM boost SAR changes according to input and output condition. The switching frequency limit logic is applied to limit the maximum switching frequency. Meanwhile, the small signal transfer function of the CRM boost SAR is simple, so the controller design is also simple. In this paper, the small signal transfer function from control reference to solar array voltage is induced. And the voltage controller is designed based on the small signal transfer function. Finally, the CRM boost SAR is verified by simulation.

Design of Dual-band Ortho-mode Transducer for Ka-band VSATs (Ka 대역 VSAT용 이중대역 직교모드변환기 설계)

  • Lee, Hongyeol;Uhm, Manseok;Yun, Sohyeun;Yom, Inbok;Kim, Hyunsoo;Park, Jeongwoo
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.3
    • /
    • pp.47-51
    • /
    • 2013
  • In this paper, we present design and test results of a Ka-band dual-band ortho-mode transducer (OMT) for use in a feed assembly for the very small aperture terminals (VSATs). The designed ortho-mode transducer have wideband characteristics to separate the signals that have two orthogonal linear polarizations operating at 20GHz of receive frequency band and at 30GHz of transmit frequency band. In addition, in order to reduce the volume of the feed assebly, a Boifot based ortho-mode transducer has been designed with a dual-band. Experimental results for the design verification, the return loss in the receive band and in the transmit band for the horizontal polarization showed over 20dB and 21dB, respectively, and for the vertical polarization showed over 20dB and 24dB, respectively. The port isolation for the horizontal polarization and the vertical polarization showed over 43dB and 52dB, respectively, in the receive band and in the vertical band.

A Study on characteristics analysis of autotrophic denitrification microbial community using sulfur granule (황입자를 이용한 T. denitrificans에 의한 질소제거 최적화 연구)

  • Yoon, Su Chul;Joo, Jae-Young;Nam, Duck-Hyun;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.2
    • /
    • pp.259-265
    • /
    • 2008
  • Generally speaking, there are two widely used methods of Nitrogen removal from waste water: 1) nitrification using autotrophic microorganisms, and 2) denitrification using heterotrophic microorganisms. The C/N ratio is an important factor of the denitrification process. In this case, if methanol is added to increase the lacking organic matter, a high economic cost is incurred and methanol is left in the processed water. In an effort to fix these issues, autotrophic denitrification through the use of Hydrogen, Iron and Sulfur is being studied, and among those Sulfur is cheaper and carries out denitrification effectively, and therefore is being studied the most. In this study, after cultivating T. denitrificans, the presence of T. denitrificans was determined and the effectiveness of denitirification via T. denitrificans was studied. In order to find out about the inhibition of T. denitrificans from the loading of organic matter, this shows that the greater the loading of organic matter, the more the denitrification ability of T. denitrificans is hindered. In order to research the hindrance of T. denitrificans resulting from the loading of $NO_3{^-}-N$, these results show that concentrations less than 100mg/L per 100mL of gel volume do not hinder T. denitrificans. In order to research the optimization of denitrification resulting from T. denitrificans, three 500mL samples of Sulfur granules were prepared: 1) one with only T. denitrificans attached (Mode I), 2) one with both T. denitrificans and active sludge attached (Mode II), and 3) one with only active sludge attached (Mode III). The results showed that autotrophic denitrification using S from Mode I was the most active.

A Study on Source Mechanisms of Micro-Cracks Induced by Rock Fracture (암석파괴시 발생되는 미세균열의 발생원에 대한 연구)

  • 김교원
    • The Journal of Engineering Geology
    • /
    • v.6 no.2
    • /
    • pp.59-64
    • /
    • 1996
  • Acoustic Emission(AE) signals are emitted by a sudden release of strain energy associated with material damage. A multi-channels of LeCroy system and piezoelectric pressure transducers are employed for AE measurement to investigate the roles of AE in the propagation of macro cracks as well as the characteris-tics of AE wave in occurrence, amplitude and dominant frequency with changes in macro loading modes. Deduced crack opening volume of micro cracks varied widely and implies that AE events could be caused by crystal dislocations on a small scale and grain boundary movements on a large scale. Amplitude of first arrival AE wave emitted during mode I test was approximately 3 times higher than those from mixed mode test, while the number of AE count in mode I test was only 25% of mixed mode. It may imply that the total energy required for generation of a given fracture surface is similar regardless in change of macroloading modes.

  • PDF

The simulation study on natural circulation operating characteristics of FNPP in inclined condition

  • Li, Ren;Xia, Genglei;Peng, Minjun;Sun, Lin
    • Nuclear Engineering and Technology
    • /
    • v.51 no.7
    • /
    • pp.1738-1748
    • /
    • 2019
  • Previous research has shown that the inclined condition has an impact on the natural circulation (natural circulation) mode operation of Floating Nuclear Power Plant (FNPP) mounted on the movable marine platform. Due to its compact structure, small volume, strong maneuverability, the Integral Pressurized Water Reactor (IPWR) is adopted as marine reactor in general. The OTSGs of IPWR are symmetrically arranged in the annular region between the reactor vessel and core support barrel in this paper. Therefore, many parallel natural circulation loops are built between the core and the OTSGs primary side when the main pump is stopped. and the inclined condition would lead to discrepancies of the natural circulation drive head among the OTSGs in different locations. In addition, the flow rate and temperature nonuniform distribution of the core caused by inclined condition are coupled with the thermal hydraulics parameters maldistribution caused by OTSG group operating mode on low power operation. By means of the RELAP5 codes were modified by adding module calculating the effect of inclined, heaving and rolling condition, the simulation model of IPWR in inclined condition was built. Using the models developed, the influences on natural circulation operation by inclined angle and OTSG position, the transitions between forced circulation (forced circulation) and natural circulation and the effect on natural circulation operation by different OTSG grouping situations in inclined condition were analyzed. It was observed that a larger inclined angle results the temperature of the core outlet is too high and the OTSG superheat steam is insufficient in natural circulation mode operation. In general, the inclined angle is smaller unless the hull is destroyed seriously or the platform overturn in the ocean. In consequence, the results indicated that the IPWR in the movable marine platform in natural circulation mode operation is safety. Selecting an appropriate average temperature setting value or operating the uplifted OTSG group individually is able to reduce the influence on natural circulation flow of IPWR by inclined condition.

Digital Variable Focal Liquid Lens (초점 조절이 가능한 디지털 유체 렌즈)

  • Lee, Dong-Woo;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.5
    • /
    • pp.557-560
    • /
    • 2010
  • We have designed a digital variable-focal-length liquid lens by using 4-bit actuators. Each bit actuator consists of 1, 2, 4, and 8 unit actuators, squeezes discrete fluidic volume of $2^4$ different levels into the lens The 4-bit digital actuation mode ($b_4b_3b_2b_1$) affords $2_4$ different lens curvatures and focal lengths. The on/off control of the bit actuators helps in solving the main problem associated with analog liquid lenses, i.e., precise control of the pressure or volume of the fluid for changing the lens curvature and focal length. Experimentally, it has been found that the 4-bit actuators allow 0.074 nl (${\pm}0.02\;nl$) of the given fluid per bit to enter the lens and help in increasing the focal length from 3.63 mm to 38.6 mm in $2^4$ different levels; no high-cost controllers are required for precise control of the pressure or volume in this case. Therefore, the present digital liquid lens is more suitable to integrated optical systems by reducing additional component for pressure and volume control.

Cost-Efficient and Automatic Large Volume Data Acquisition Method for On-Chip Random Process Variation Measurement

  • Lee, Sooeun;Han, Seungho;Lee, Ikho;Sim, Jae-Yoon;Park, Hong-June;Kim, Byungsub
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.2
    • /
    • pp.184-193
    • /
    • 2015
  • This paper proposes a cost-efficient and automatic method for large data acquisition from a test chip without expensive equipment to characterize random process variation in an integrated circuit. Our method requires only a test chip, a personal computer, a cheap digital-to-analog converter, a controller and multimeters, and thus large volume measurement can be performed on an office desk at low cost. To demonstrate the proposed method, we designed a test chip with a current model logic driver and an array of 128 current mirrors that mimic the random process variation of the driver's tail current mirror. Using our method, we characterized the random process variation of the driver's voltage due to the random process variation on the driver's tail current mirror from large volume measurement data. The statistical characteristics of the driver's output voltage calculated from the measured data are compared with Monte Carlo simulation. The difference between the measured and the simulated averages and standard deviations are less than 20% showing that we can easily characterize the random process variation at low cost by using our cost-efficient automatic large data acquisition method.

Effect of Hemodialysis on Left and Right Ventricular Volume and Function (말기신질환에서 혈액투석에 따르는 좌우심실용적 및 기능변화에 관한 연구)

  • Han, Jin-Suk;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.19 no.2
    • /
    • pp.43-50
    • /
    • 1985
  • With the improvement of hemodialysis, the course of the disease in patient with endstage renal disease has been clearly improved. Nevertheless, among several shortcomings to our present mode of renal replacement therapy, cardiovascular complications have been the leading cause of morbidity and mortality. Several factors such as anemia, arteriovenous shunting of blood, intermittent extracorporeal circulation and hypertension may be contributing. But little is known about the quantitative cardiac hemodynamic characteristics occurred during hemodialysis. The purpose of this study is to observe the sequential hemodynamic changes before, during and after the hemodialysis and to investigate reliable parameters in the detection of ventricular dysfunction. In the present study, equilibrium radionuclide cardiac angiography was performed and left and right ventricular volume indices, ejection phase indices of both ventricular, performance were measured in the 16 stable patients with chronic renal failure treated with maintenance hemodialysis sequentially i.e. before, during (early and late phase) and after the hemodialysis. The results obtained were as follows; 1) The indices of the left ventricular function were not changed during the hemodialysis but increased after the hemodialysis. 2) The indices of the right ventricular function(EF, SVI) were significantly decreased in the early phase (15, 30 minutes after starting extracorporeal circulation) but recovered after the hemodialysis. 3) The ratio of right ventricular to left ventricular ejection fraction was significantly decreased in the early phase and the lung volume indices were significantly increased at the same phase. As a conclusion, hemodialysis improves left ventricular function maybe due to increased contractility, and effects on the right ventricular function maybe due to the increased lung volume in the early phase of hemodialysis.

  • PDF

Analysis of the dynamic confining effect of CRAC short column under monotonic loadings

  • Wang, Changqing;Xiao, Jianzhuang
    • Structural Engineering and Mechanics
    • /
    • v.74 no.3
    • /
    • pp.351-363
    • /
    • 2020
  • Based on the dynamic tests of recycled aggregate concrete (RAC) short columns confined by the hoop reinforcement, the dynamic failure mechanism and the mechanical parameters related to the constitutive relation of confined recycled aggregate concrete (CRAC) were investigated thoroughly. The fracturing sections were relatively flat and smooth at higher strain rates rather than those at a quasi-static strain rate. With the increasing stirrup volume ratio, the crack mode is transited from splitting crack to slipping crack constrained with large transverse confinement. The compressive peak stress, peak strain, and ultimate strain increase with the increase of stirrup volume ratio, as well as the increasing strain rate. The dynamic confining increase factors of the compressive peak stress, peak strain, and ultimate strain increase by about 33%, 39%, and 103% when the volume ratio of hoop reinforcement is increased from 0 to 2%, but decrease by about 3.7%, 4.2%, and 9.1% when the stirrup spacing is increased from 20mm to 60mm, respectively. This sentence is rephrased as follows: When the stirrup volume ratios are up to 0.675%, and 2%, the contributions of the hoop confinement effect to the dynamic confining increase factors of the compressive peak strain and the compressive peak stress are greater than those of the strain rate effect, respectively. The dynamic confining increase factor (DCIF) models of the compressive peak stress, peak strain, and ultimate strain of CRAC are proposed in the paper. Through the confinement of the hoop reinforcement, the ductility of RAC, which is generally slightly lower than that of NAC, is significantly improved.

Development of Dual-mode Signal Processing Module for Multi-slit Prompt-gamma Camera (다중 슬릿 즉발감마선 카메라를 위한 이중모드 신호처리 모듈 개발)

  • Park, Jong Hoon;Lee, Han Rim;Kim, Sung Hun;Kim, Chan Hyeong;Shin, Dong Ho;Lee, Se Byeong;Jeong, Jonh Hwi
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.37-45
    • /
    • 2016
  • In proton therapy, in vivo proton beam range verification is very important to deliver conformal dose to the target volume and minimize unnecessary dose to normal tissue. For this purpose, a multi-slit prompt-gamma camera module made of 24 scintillation detectors and 24-channel signal processing system is under development. In the present study, we have developed and tested a dual-mode signal processing system, which can operate in the energy calibration mode and the fast data acquisition mode, to process the signals from the 24 scintillation detectors. As a result of performance test, using the energy calibration mode, we were able to perform energy calibration for the 24 scintillation detectors at the same time and determine the discrimination levels for the detector channels. Further, using the fast data acquisition mode, we were able to measure a prompt-gamma distribution induced by a 45 MeV proton beam. The measured prompt gamma distribution was found similar to the proton dose distribution at the distal fall-off region, and the estimated beam range was $17.13{\pm}0.76mm$, which is close to the proton beam range of 16.15 mm measured by an EBT film.