• Title/Summary/Keyword: mode shape

Search Result 1,545, Processing Time 0.025 seconds

An Experimental Study on Deep Collapse of Steel Tubes under Pure Bending (순수 굽힘 시험기를 이용한 연강 사각관의 굽힘 붕괴에 관한 실험적 연구)

  • KiM, C.S.;Chung, T.E.;Kang, S.Y.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.9
    • /
    • pp.37-44
    • /
    • 1997
  • In this paper the bending collapse characteristics of square and rectangular steel tubes were studied with the pure bending test machine which apply pure bending moment without imposing shear and tensile forces. Under pure bending moment, delayed buckling modes occur and depend on test length and shape of section. For delayed mode, the endrgy of bending moment is absorbed by strain hardening energy. The pre- dictions of maximum moment and moment-rotation angle curve from those concepts are in good agreement with experimental observations.

  • PDF

Estimations of Offshore Structure Damages by Modal Perturbation Method (Modal-Perturbation 기법을 이용한 항만 구조물의 손상부위 추정)

  • 조병완;한상주
    • Computational Structural Engineering
    • /
    • v.9 no.4
    • /
    • pp.209-217
    • /
    • 1996
  • An Inverse modal perturbation method was applied to estimate the assessments of the damages at the large-scaled marine structure, such as pier or dolphin, from the structural dynamic natural frequencies and mode shape. Vibrations of structural stiffness, natural frequencies and mode shapes from the eigenvalue analysis lead to the modal peturbation equations, which were considered with a second order term. This paper estimates the assessments of the damages for the structure with the decreased stiffness and shows the convergence of perturbation equation.

  • PDF

Life Analysis of Pneumatic Valve (공기압 밸브의 수명 분석)

  • Kang, Bo-Sik;Lee, Seung-Hun;Kim, Kyung-Soo;Lim, Nam-Gu;Kim, Hyoung-Eui
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1848-1853
    • /
    • 2007
  • In this study, we are to analyze the life and the main failure mode of pneumatic valves that are usually applied to the factory automation line. Pneumatic valves have complicated failure cause since they are organized as a complex of various elements. Therefore, in this paper, we analyzed the main failure mode of pneumatic valves, and then performed life test and performance test according to the international standards. On the basis of these processes, we estimated a shape parameter that is the main factor for the calculation of test time for the reliability of pneumatic valves by analyzing life distribution data.

  • PDF

Life Analysis of Flexible Tubes Fitting for Pneumatic system (공기압용 관연결 피팅의 수명 분석)

  • Kang, Bo-Sik;Song, Joo-Sub;Yoo, Yung-Chul;Kim, Hyoung-Eui
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1842-1847
    • /
    • 2007
  • In this study, we are to analyze the life and the main failure mode of flexible tubes fitting for pneumatic that are usually applied in the factory automation line. Flexible tubes fitting for pneumatic have complicated failure cause because they are organized as a complex of various elements. Therefore, in this paper, we analyzed the main failure mode of flexible tubes fitting for pneumatic, and then performed life test and performance test according to the international standards. On the basis of these processes, we estimate shape parameter that is the main factor for the calculation of test time for the reliability of flexible tubes fitting for pneumatic and their data analysis of life distribution.

  • PDF

Reduction of Transient Vibration on $H_2$ Piping System for Generator Cooling in a Power Plant (화력발전소 발전기 냉각용 수소배관계 과도진동 개선)

  • Yang, Kyeong-Hyeon;Kim, Sung-Hwi;Cho, Chul-Whan;Bae, Chun-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.588-592
    • /
    • 2002
  • There was the transient vibration on $H_2$ piping system for cooling the generator in a power plant. We found it was resulted from resonance between the natural vibration of the piping system and exciting force from the turbine rotor by measurement and simulation test. We verified it would be changed the mode shape of the piping system by several simulation test for the structural modification of the piping system. Therefore we concluded that the change of natural vibration mode depends on deeply changing effective length of pipe and reducing supports.

  • PDF

Step-Down Voltage Properties of Piezoelectric Transformer with Extensional Vibration Mode (Extensional 진동 모드를 이용한 압전 트랜스포머의 감압 특성)

  • Choi, Ji-Hyun;Bang, Kyu-Seok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.652-655
    • /
    • 2003
  • In this paper, step-down piezoelectric transformer is studied. The piezoelectric transformer, made of lead zirconate titanate solid solution ceramic, is operated by a fundamental contour-extensional vibration mode. The transformer of 14mm length, 14mm width and 4.5mm thickness was made up two shape(Type I and II). The resonant frequency (fr) is 144kHz and 128kHz at the load resistant of $7.5{\Omega}$ that is a similar to calculating matching impedance. The gain (G) obtained 0.19 and 0.08 at each resonant frequency, when applied input voltage is 25V. The temperature difference with the variation of load resistant was increased with increasing load resistant and was the lowest at $7.5{\Omega}$ near the matching of output impedance.

  • PDF

Vibration Control of Tower Structure under Wind Load (풍하중에 의한 타원형 구조물의 진동 제어)

  • Hwang Jae-Seung;Kim Yun-Seok;Joo Seok-Jun
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.427-430
    • /
    • 2002
  • The present parer outlines the system identification and vibration control performance of air traffic control tower of Yangyang international airport with tuned mass damper(TMD). From the free vibration test, natural frequency, damping ratio and mode shape of tower are obtained and these values are compared with the values from numerical analysis. In the vibration control test to evaluate the vibration control performance, equivalent damping ratio increased by tuned mass damper are obtained in case the TMD is operated as passive mode. Damping ratio of tower evaluated from free vibration test is about $1.0{\%}$. It is very low value than damping ratio recommended in general code. Damping ratio of passive mode is about $5{\%}$. These equivalent damping ratio increased by TMD is enough to enhance the serviceability of tower structure under wind load.

  • PDF

Experimental Method of a Super Structure (선체 상부구조물의 실험적 해석)

  • 박석주;박성현;오창근;제해광
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.328-334
    • /
    • 2001
  • Up to now. vibration analysis and vibration engineering have been developed, encompassing the aspects of both experimental and analytical techniques. Using experimental modal analysis or modal testing, the mode shapes and frequencies of practical structure can be measured accurately. Curve-Fitting Method is realized through experimental modal identification. In the experimental modal parameter estimation, the estimation of modal damping factor is difficult for complicated and large structure. Also numbers of Selected mode are determined before the procedure. This paper describes the vibration shape of the super-structure model of ship through experimental modal analysis.

  • PDF

fictive Noise Control of Enclosed Sound Field Using LQR Controller (LQR 제어기를 이용한 밀폐음장의 능동소음제어)

  • 유우열;김우영;황원걸;이유엽
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.1
    • /
    • pp.12-20
    • /
    • 2002
  • To control the noise of an enclosed sound field, we built a state space model using the acoustic modal parameter description. Using the state space model, we can investigate the controllability and observability, and find an appropriate position of control speaker and microphone to control sound field of the enclosed space. We implemented LQR(linear quadratic regulator) controller and reduced order observer to reduce the first acoustic mode. Experiments showed satisfactory results of 4∼10 dB reduction of magnitude of the first acoustic mode, and support the feasibility of the proposed scheme to lightly damped acoustic field.

A Study on the Effect of Beam Mode on the Size of Hardened Zone in Laser Surface Hardening (레이저 표면경화처리에서 빔의 형태가 경화층 크기에 미치는 영향에 관한 연구)

  • Kim, J.W.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.4
    • /
    • pp.64-72
    • /
    • 1993
  • Analytical models for the prediction of the size of hardened zone in laser surface hardening are presented. The models are based on the solutions to the problem of three-dimensional heat flow in plates with infinite thickness. The validity of the model was tested on medium carbon steel for Gaussian mode of beam. Then the model for rectagular beam was used for the predicition of the size of hardened zone on various hardening process parameters. From the calculation results it appeared that the size and shape of the hardened zone are strongly dependent on process parameters such as beam mode, beam size, and traverse speed.

  • PDF