• Title/Summary/Keyword: mode identification

Search Result 593, Processing Time 0.034 seconds

Mode analysis of end-milling process by recursive parametric modelling (순환 파라메트릭 모델링에 의한 엔드밀 시스템의 모드 분석)

  • Kim, T.H.;Kim, J.D.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.73-79
    • /
    • 2011
  • In this study, an analytical realization of end-milling system was introduced using recursive parametric modeling analysis. Also, the numerical mode analysis of end-milling system with different conditions was performed systematically. In this regard, a recursive least square modelling algorithm and the natural mode for real part and imaginary one was discussed. This recursive approach (RLSM) can be adopted for on-line end-milling identification. After experimental practice of the end-milling, the end-milling force was obtained and it was used for the calculation of FRF (Frequency response function) and mode analysis. Also the FRF was analysed for the prediction of a end-milling system using recursive algorithm.

Study on the Relationship between Carotid Intima-Media Thickness and Korean Standard of Pattern Identification in Ischemic Stroke Patients (뇌경색 환자의 경동맥 초음파 검사와 한방 중풍 변증과의 관련성 연구)

  • Kim, Kyoung Min
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.15 no.1
    • /
    • pp.29-38
    • /
    • 2014
  • ■ Objectives The purpose of this study was to investigate the correlation of The Korean Standard Pattern Identification for Stroke and Intima-Media Thickness of common carotid artery(CCA-IMT). ■ Methods 100 subjects with acute ischemic stroke were recruited from the patients admitted to DongEui Medical Center from the June 2011 to January 2014. We assessed 100 patient's Common Carotid Intima Media Thickness data by B Mode ultrasonography. We investigated pattern identification of all subjects based on Korean Standard Pattern Identification for Stroke-III. then, We analyzed their characteristics, risk factor, blood test result, life style. ■ Results We analyzed indicators of Korean Standard Pattern Identification for Stroke-III by Common Carotid Intima Media Thickness difference. As a result, pale complexion, look powerless, drowsiness like to lie, heat vexation and aversion to heat were significantly higher in the CCAIMT ≧ 1.0mm group then in the CCA-IMT < 1.0mm group. ■ Conclusion According to the analysis, the Relationship between Carotid Intima-Media Thickness and The Korean Standard Pattern Identification for Stroke in Ischemic Stroke Patients were founded. To acquire more concrete conclusion on this theme, we need more research.

  • PDF

Model Analysis of Plate using by Digital Test System (디지털 실험장치를 이용한 판의 모우드 해석)

  • Hong, Bong-Ki;Bae, Dong-Myung;Bae, Seong-Yoeng
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.29 no.1
    • /
    • pp.39-55
    • /
    • 1993
  • Modal Analysis is the process of characterizing the dynamic properties of an elastic structure by identifying its modes of vibration. A mode of vibration is a global property of an elastic structure. That is, a mode has a specific natural frequency and damping factor which can be identified from response data at practically any point on a structure, and it has a characteristic mode shape which identifies the mode spatially over the entire structure. Modal testing is able to be performed on structural and mechanical structure in an effort to learn more about their elastic behavior. Once the dynamic properties of a structure are known its behavior can be predicted and therefore controlled or corrected. Resonant frequencies, damping factors and mode shape data can be used directly by a mechanical designer to pin point weak spots in a structure design, or this data can also be used to confirm or synthesize equations of motion for the elastic structure. These differential equations can be used to simulate structural response to know input forces and to examine the effects of pertubations in the distributed mass, stiffness and damping properties of the structure in more detail. In this paper the measurement of transfer functions in digital form, and the application of digital parameter identification techniques to identify modal parameters from the measured transfer function data are discussed. It is first shown that the transfer matrix, which is a complete dynamic model of an elastic plate structure can be written in terms of the structural modes of vibration. This special mathematical form allows one to identify the complete dynamics of the structure from a much reduced set of test data, and is the essence of the modal approach to identifying the dynamics of a structure. Finally, the application of transfer function models and identification techniques for obtaining modal parameters from the transfer function data are discussed. Characteristics on vibration response of elastic plate structure obtained from the dynamic analysis by Finite Element Method are compared with results of modal analysis.

  • PDF

Analytical and experimental modal analyses of a highway bridge model

  • Altunisik, Ahmet Can;Bayraktar, Alemdar;Sevim, Baris
    • Computers and Concrete
    • /
    • v.12 no.6
    • /
    • pp.803-818
    • /
    • 2013
  • In this study, analytical and experimental modal analyses of a scaled bridge model are carried out to extract the dynamic characteristics such as natural frequency, mode shapes and damping ratios. For this purpose, a scaled bridge model is constructed in laboratory conditions. Three dimensional finite element model of the bridge is constituted and dynamic characteristics are determined, analytically. To identify the dynamic characteristics experimentally; Experimental Modal Analyses (ambient and forced vibration tests) are conducted to the bridge model. In the ambient vibration tests, natural excitations are provided and the response of the bridge model is measured. Sensitivity accelerometers are placed to collect signals from the measurements. The signals collected from the tests are processed by Operational Modal Analysis; and the dynamic characteristics of the bridge model are estimated using Enhanced Frequency Domain Decomposition and Stochastic Subspace Identification methods. In the forced vibration tests, excitation of the bridge model is induced by an impact hammer and the frequency response functions are obtained. From the finite element analyses, a total of 8 natural frequencies are attained between 28.33 and 313.5 Hz. Considering the first eight mode shapes, these modes can be classified into longitudinal, transverse and vertical modes. It is seen that the dynamic characteristics obtained from the ambient and forced vibration tests are close to each other. It can be stated that the both of Enhanced Frequency Domain Decomposition and Stochastic Subspace Identification methods are very useful to identify the dynamic characteristics of the bridge model. The first eight natural frequencies are obtained from experimental measurements between 25.00-299.5 Hz. In addition, the dynamic characteristics obtained from the finite element analyses have a good correlation with experimental frequencies and mode shapes. The MAC values obtained between 90-100% and 80-100% using experimental results and experimental-analytical results, respectively.

Modal testing and finite element model calibration of an arch type steel footbridge

  • Bayraktar, Alemdar;Altunisk, Ahmet Can;Sevim, Baris;Turker, Temel
    • Steel and Composite Structures
    • /
    • v.7 no.6
    • /
    • pp.487-502
    • /
    • 2007
  • In recent decades there has been a trend towards improved mechanical characteristics of materials used in footbridge construction. It has enabled engineers to design lighter, slender and more aesthetic structures. As a result of these construction trends, many footbridges have become more susceptible to vibrations when subjected to dynamic loads. In addition to this, some inherit modelling uncertainties related to a lack of information on the as-built structure, such as boundary conditions, material properties, and the effects of non-structural elements make difficult to evaluate modal properties of footbridges, analytically. For these purposes, modal testing of footbridges is used to rectify these problems after construction. This paper describes an arch type steel footbridge, its analytical modelling, modal testing and finite element model calibration. A modern steel footbridge which has arch type structural system and located on the Karadeniz coast road in Trabzon, Turkey is selected as an application. An analytical modal analysis is performed on the developed 3D finite element model of footbridge to provide the analytical frequencies and mode shapes. The field ambient vibration tests on the footbridge deck under natural excitation such as human walking and traffic loads are conducted. The output-only modal parameter identification is carried out by using the peak picking of the average normalized power spectral densities in the frequency domain and stochastic subspace identification in the time domain, and dynamic characteristics such as natural frequencies mode shapes and damping ratios are determined. The finite element model of footbridge is calibrated to minimize the differences between analytically and experimentally estimated modal properties by changing some uncertain modelling parameters such as material properties. At the end of the study, maximum differences in the natural frequencies are reduced from 22% to only %5 and good agreement is found between analytical and experimental dynamic characteristics such as natural frequencies, mode shapes by model calibration.

Integrity Estimation for Concrete Pontoon of Floating Structure (콘크리트 부유식 구조물 함체의 건전성 평가)

  • Park, Soo-Yong;Kim, Min-Jin;Seo, Young-Kyo
    • Journal of Navigation and Port Research
    • /
    • v.37 no.5
    • /
    • pp.527-533
    • /
    • 2013
  • This paper presents damage detection and estimation of stiffness parameter on a concrete scale model and a real structure of concrete pontoon using dynamic properties such as mode shapes and natural frequencies. In case of damage detection, dynamic impact test on a concrete scale model is accomplished to extract mode shapes and the practicality is verified by utilizing a damage detection technique. And the stiffness parameter of a real structure of concrete pontoon was estimated via system identification technique using the natural frequencies of the structure. The results indicate that the damaged elements of the scale model are found exactly using damage detection technique and the effective stiffness property of the real structure of concrete pontoon can be estimated by system identification technique.

Experimental evaluation of crack effects on the dynamic characteristics of a prototype arch dam using ambient vibration tests

  • Sevim, Baris;Altunisik, Ahmet Can;Bayraktar, Alemdar
    • Computers and Concrete
    • /
    • v.10 no.3
    • /
    • pp.277-294
    • /
    • 2012
  • The aim of the study is to determine the modal parameters of a prototype damaged arch dam by operational modal analysis (OMA) method for some damage scenarios. For this purpose, a prototype arch dam-reservoir-foundation model is constructed under laboratory conditions. Ambient vibration tests on the arch dam model are performed to identify the modal parameters such as natural frequency, mode shape and damping ratio. The tests are conducted for four test-case scenarios: an undamaged dam with empty reservoir, two different damaged dams with empty reservoirs, and a damaged dam with full reservoir. Loading simulating random impact effects is applied on the dam to crack. Cracks and fractures occurred at the middle of the upper part of the dams and distributed through the abutments. Sensitivity accelerometers are placed on the dams' crests to collect signals for measurements. Operational modal analysis software processes the signals collected from the ambient vibration tests, and enhanced frequency domain decomposition and stochastic subspace identification techniques are used to estimate modal parameters of the dams. The modal parameters are obtained to establish a basis for comparison of the results of two techniques for each damage case. Results show that approximately 35-40% difference exists between the natural frequencies obtained from Case 1 and Case 4. The natural frequencies of the dam considerably decrease with increasing cracks. However, observation shows that the filled reservoir slightly affected modal parameters of the dam after severe cracking. The mode shapes obtained are symmetrical and anti-symmetrical. Apparently, mode shapes in Case 1 represent the probable responses of arch dams more accurately. Also, damping ratio show an increase when cracking increases.

System Identification of Helicopter Using OCID Algorithm (OCID 알고리듬을 이용한 헬리콥터 시스템 판별)

  • Park, M.S.;Kim, B.D.;Roh, C.W.;Hong, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.556-559
    • /
    • 1999
  • In this paper, the Observer Controller IDentification/Eigensystem Realization Algorithm(OCID/ERA) is applied to identify the state space model of a helicopter in hover from a given set of the general input-output data. The objective of this paper is the evaluation of the utility of the OCID/ERA approach to the system identification of a system which has natural unstable mode like a helicopter and to give some guidelines before applying the technique to the real system. As it mentioned above, since a model helicopter is unstable naturally, the closed-loop system identification method(OCID/ERA) using excitation, output and feedback signals of the simulated system is applied.

  • PDF

Experimental Verification of the Structural Damage Identification Method Developed for Beam Structures (보 구조물에 대한 손상규명기법의 실험적 검증)

  • Cho, Kook-Lae;Shin, Jin-Ho;Lee, U-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.12
    • /
    • pp.2574-2580
    • /
    • 2002
  • In this paper, an experimental verification has been conducted for the frequency response function (FRF)-based structural damage identification method (SDIM) proposed for beam structures. The FRF-based SDIM requires the natural frequencies and mode shapes measured in the intact state and the FRF-data measured in the damaged state. Experiments are conducted for the cantilevered beam specimens with one slot and with three slots. It is shown that the proposed FRF-based SDIM provides damage identification results that agree quite well with true damage state.