• 제목/요약/키워드: mode attenuation

검색결과 156건 처리시간 0.019초

Attenuation of Fundamental Longitudinal Guided Wave Mode in Steel Pipes Embedded in Soil

  • Lee, Ju-Won;Shin, Sung-Woo;Na, Won-Bae
    • 비파괴검사학회지
    • /
    • 제30권6호
    • /
    • pp.539-547
    • /
    • 2010
  • In this study, characteristics of the fundamental longitudinal guided wave mode, L(0,1), which is a usual mode employed in the inspection of the above-ground pipe, of the buried pipe were numerically investigated considering property changes in the surrounding soil. Results showed that soil conditions are significantly affecting the attenuation of L(0,1) mode in the pipe embedded in soil. Especially, if the soil is partially saturated, the attenuation of L(0,1) mode is larger and is very similar regardless of the degree of water saturation in the surrounding soil. However, when the soil is fully saturated, the attenuation of L(0,1) mode is less and show different trend with its partially saturated counterparts.

주변 흙의 특성이 물이 찬 매립된 배관에서 전파되는 기본 유도 종파 모드 감쇠에 미치는 영향 (Effect of Surrounding Soil Properties on the Attenuation of the First Guided Longitudinal Wave Mode Propagating in Water-filled, Buried Pipes)

  • 이주원;나원배;신성우;김재민
    • 한국해양공학회지
    • /
    • 제24권4호
    • /
    • pp.32-37
    • /
    • 2010
  • This study presents the attenuation characteristics of the first guided longitudinal wave mode propagating in water-filled, buried steel pipes in order to investigate the effects of soil saturation and compaction on the attenuation patterns. For numerical calculation of attenuation, 10 different combinations of S-wave velocity, P-wave velocity, and soil densities were considered. From the attenuation dispersion curves, which were obtained using Disperse software, we determined that the attenuation decreases as saturation increases, whereas it increases as compaction increases. Over the frequency range from 0.2 to 0.4 MHz, the first longitudinal wave mode has attenuations that are relatively lower than for other ranges, is faster than the first flexural wave mode, and is sensitive to defects aligned in the axial direction. Hence, the first longitudinal wave mode over the mentioned frequency range would be the proper choice for long-range buried pipelines that transport water.

수치해석과 모형실험을 통한 매립배관에서의 유도초음파 L(0,2) 모드의 감쇠 특성 평가 (Attenuation Characterization of L(0,2) Guided Wave Mode through Numerical Analyses and Model Experiments with Buried Steel Pipe)

  • 이주원;나원배
    • 한국해양공학회지
    • /
    • 제27권1호
    • /
    • pp.16-23
    • /
    • 2013
  • By carrying out numerical analyses and model experiments, this paper presents the attenuation characterization of an L(0,2) guided ultrasonic wave propagating in a buried steel pipe. From this investigation, we first find that the L(0,2) mode has a better attenuation property. Second, it is shown from the numerical analyses that the attenuation increases with increases in the soil embedment length (0, 500, 1000, and 1500 mm) and degrees of saturation (0, 50, 99, and 100%). Third, it is also shown from the model experiment that the attenuation increases as the embedment lengths and soil moisture quantities (0, 10, 20, and 30 kg) increase. Finally, we find that an exponential extrapolation gives a better attenuation prediction because the extrapolation gives similar attenuation patterns between the numerical and experimental results.

지하매설 유체함입 강파이프의 감쇠특성 규명 (Attenuation Characteristics of the Buried Steel Water Pipes)

  • 박경조;강우석;김이곤
    • 동력기계공학회지
    • /
    • 제13권1호
    • /
    • pp.39-45
    • /
    • 2009
  • The attenuation of the fundamental non-torsional modes that propagate down buried steel water pipes has been studied. The mode shapes, mode attenuation due to leakage into the surrounding medium and the scattering of the modes as they interact with pipe joints and fittings have been investigated. In the low frequency region the mode predicted to dominate over significant propagation distances approximates a plane wave in the water within pipe. The established acoustic technique used to locate leaks in buried steel water pipes assumes that leak noise propagates as a single non-dispersive mode at a velocity related to the low frequency asymptote of this water borne mode.

  • PDF

지반의 수분 상태에 따른 매립 배관에서의 유도초음파 모드 감쇠 변화 (Effect of Moisture Conditions in Soils on Mode Attenuation of Guided Waves in Buried Pipes)

  • 이주원;신성우;나원배;김영상
    • 한국안전학회지
    • /
    • 제25권4호
    • /
    • pp.42-47
    • /
    • 2010
  • Recently, many techniques have been developed for the inspection of pipelines using guided waves. However, few researches have been made on the application of those techniques for buried underground pipes. Guided wave motions in the buried pipes are somewhat different from those of on-ground pipes which have traction-free (air) boundary condition on outer pipe walls and thus are strongly affected by the mechanical property of the surrounding soils. Therefore, it should be investigated the effect of soil properties on the guided wave behavior in buried pipe. On the other hand, the mechanical property of soil is largely depending on its moisture conditions nevertheless of other influential factors such as void ratio. In this study, the effect of moisture conditions in soils on mode attenuation of guided waves in the buried pipe is investigated. To this end, numerical study is performed to characterize mode attenuation behavior in buried pipes and the effective mode which is suitable for long range inspection is identified.

Dielectric Band-Pass Filter with Attenuation Poles at Desired Frequencies

  • Lee, Moon-Que
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권6호
    • /
    • pp.268-271
    • /
    • 2004
  • An analytic design formula is proposed for a TEM mode dielectric bandpass filter with attenuation poles at desired frequencies in the stop band. In order to sustain the constant ripple in the passband due to attenuation poles, the initial resonant frequencies of the various resonators adopted in a filter with attenuation poles are newly calculated. The proposed design theory is verified by designing various bandpass filters with attenuation poles in the stop band.

Mode Selection of Leaky Lamb Waves in Steel Plate

  • ;;;나원배
    • 한국해양공학회지
    • /
    • 제22권1호
    • /
    • pp.6-12
    • /
    • 2008
  • The dispersion and attenuation of Lamb and Leaky Lamb waves propagating in a 1 mm-thick steel plate were investigated. For acquiring a long(or large) range inspection capability, the fundamental symmetric and anti-symmetric wave modes(S0 and A0) over law frequencies were studied. Based on the dispersion curves, as well as pitch-catch and multi-mode simulations, it was shown that the S0 mode over law frequencies is the proper mode to minimize the dispersion and attenuation. In addition, it was shown that the S0 mode couldbe easily distinguished under multi-mode simulation since it has a larger group velocity than the A0 mode.

적층내 탄성 유도초음파의 모드 특성에 관한 연구 (A Study on Elastic Guided Wave Modal Characteristics in Multi-Layered Structures)

  • 조윤호;이종명
    • 비파괴검사학회지
    • /
    • 제28권2호
    • /
    • pp.211-216
    • /
    • 2008
  • 이 연구에서 다층구조물에서 각 모드에 대한 위상속도, 군속도, 감쇠 그리고 파형구조를 구하는 프로그램을 개발하였다. 판의 수와 재료 물성치를 변화시키면서 각 모드의 파형구조를 얻었다. 유체가 닿아 있는 구조물에서 유도파를 이용한 비파괴 검사의 성공여부는 에너지 손실을 최소화하는 모드선정의 최적화이다. 이 연구에서는 자유표면판재의 표면에서 정규화된 두께방향의 변위가 감쇠의 변화를 예측하기 위해서 사용되었으며 감쇠와 파형구조의 관계를 밝혔다. 이것은 유도파의 감쇠를 물이 닿아 있는 경우 복소수근을 찾는 수학적 어려움을 경감하면서 자유표면에서 두께방향 변위의 변화로부터 손쉽게 얻을 수 있다. 이 연구를 통하여 다층구조물에서 보다 민감하고 효율적인 비파괴 검사를 위한 유도파의 모드선정의 최적화 개념을 완성했다.

유도초음파의 감쇠계수에 대한 실험적 고찰 (Experimental Investigation for the Attenuation Coefficient of Ultrasonic Guided Wave)

  • 이동진;조윤호;이준현;신동철
    • 비파괴검사학회지
    • /
    • 제29권5호
    • /
    • pp.458-465
    • /
    • 2009
  • 일반적인 산업현장에서 내부결함 평가를 위해 사용되어온 유도초음파기법은 비결함 지역에서는 에너지 감쇠를 고려하지 않고 적용되어 왔다. 결함 지역에서의 신호는 산란과 반사에 의해서 분명한 감쇠가 발생하지만 비결함 지역에서도 작은 감쇠가 발생한다. 또한 분산선도에서 판파(Lamb wave)는 각 두께, 주파수에 의해 분산성이 달라지기에 각 모드에 적합한 감쇠계수를 찾는 것은 중요하다. 이를 위해 접촉식 PZT(piezoelectric)센서를 이용한 pitch-catch 방식으로 거리에 따른 각 모드의 감쇠계수를 구하였다. 본 연구에서는 흔히 쓰이는 알루미늄과 구리판으로, 두께 차이, 모드 차이, 재질 차이에 의한 실험적인 감쇠율을 구하는데 중점을 두었다. 그 결과 각 변수에 따라 감쇠계수는 달라지며, 정량화가 필요하다는 것을 확인하였다.

진동모드에 따른 각종 장갑의 방진효과 분석 (An Analysis of Vibration Attenuation Effect of the different type of Gloves and Drilling Mode)

  • 황성환;이형일;이동충
    • 산업경영시스템학회지
    • /
    • 제24권69호
    • /
    • pp.65-73
    • /
    • 2001
  • The objective of this study is to evaluate the vibration attenuation effects of the different type of gloves and drilling mode while operating a light-weighted powered hand drill. For the experimental design, five different kinds of glove(barehanded cotton partly coated anti-vibration, and open-finger vibration glove) two types of push force level(100N and 200N) and two types of drilling mode(impact and non-impulsive) were considered. Six healthy male subjects were employed to drive screws into a vertically mounted marble plate with a powered hand drill in a randomly ordered experimental conditions. The findings of this study are summarized as follows; (1) It was found that the best combination of overall BMS transmissibility was using impact drilling mode with anti-vibration glove among evaluated experimental conditions (2) The wearing open finger vibration glove in mid-frequency level and anti-vibration glove with impact drill in high-frequency were the best in the result from mean corrected transmissibility equation of ISO 10819.

  • PDF