• Title/Summary/Keyword: mock up test

Search Result 354, Processing Time 0.031 seconds

Surface Curing Method of Hot weather Concreting with the Combination of Surface Curing sheets (표면 양생시트 조합에 의한 서중콘크리트용 표면 양생공법)

  • Lee, Ju-Suck;Kim, Jong-Back;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.785-788
    • /
    • 2006
  • This paper investigates the temperature history of slab mock-up specimens with various surface curing sheets, in order to determine a favorable surface curing method in hot weather condition. Test showed that insulating double bubble sheets+aluminum foil simultaneously on the upper section of a specimen prevented an increase of sudden temperature and a decrease of vaporization when placed during the hot weather condition. It also secured the high strength in early age. Therefore it is found that using the double bubble sheets+aluminum foil on concrete surface declined the plastic and drying shrinkage and inclined the early strength, thus improving the concrete quality.

  • PDF

A Study on Characteristics of Normal Strength Concrete adapted to Concrete Filled Steel Tube (콘크리트 충전강관구조(CFT) 적용을 위한 일반강도 콘크리트 물성에 관한 실험적 연구)

  • 강동현;강용학;정근호;이영도;이장오
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.46-51
    • /
    • 2001
  • As a rule, in case of CFT for high-rise building, high strength concrete is required since it should have high fluidity, segregation resistance and large proportion of cement per unit considering the fi11ing beneath the diaphragm. However, regarding the low-rise building under 20 stories, it is somewhat difficult to use high strength concrete. This is a fundamental study to develop a concrete with normal strength and high fluidity for CFT of low-rise building, whose purposes are in speculating several kinds of changes in concrete's characteristics through various experiments and offering basic documents for practicalization in si to and production through mock-up test.

  • PDF

The Fabrication and Control Logic Design of Proto-type Drive System (시험용 구동시스템의 제작 및 제어로직 설계)

  • Kim, S.G.;Lee, E.W.
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.36-38
    • /
    • 2001
  • A neutron controls a nuclear fission in the core of a reactor. Drive system for in-core neutron detector is an equipment that drives the detector and cable to survey neutron flux in the reactor. The drive system introduced by this paper was designed for mock-up system and fabricated to drive two drivers that having a different function. The system consists of a driver assembly, a power transmission part, and cable storage part. And there is a control panel that contains PLC and inverter. This paper is going to introduce the design and certify the operation status of completed system by control panal. And we conducted the test for torque measurement.

  • PDF

An Experimental Study on the Hydration Heat Control of Mass Concrete Using Heat Pipe (히트파이프를 이용한 매스콘크리트의 수화열 제어에 관한 실험 연구)

  • BaeK, Dong-Il
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.6
    • /
    • pp.81-86
    • /
    • 2007
  • In order to eliminate the hydration heat of mass concrete, this paper reports the results of hydration heat control in mass concrete using the OCHP (Oscillating capillary tube heat pipe). In the summarized results of the mock up experiments, distributing the heat pipe at 300 mm intervals based on the center of the test specimen was the most effective. A 200 mm turn interval for the heat pipe was measured to be the most appropriate, taking into account the reinforcement placing at the actual site. Therefore, when the hydration heat control method using the heat pipe developed in this study is applied, not only canconstruction efficiency & a reduction in the necessary construction time be expected, but so can outstanding economical effects.

Emission rates of VOCs/VVOCs from multi-layers and their impacts on indoor air quality of Apartments (마감공사후 경과시간에 따른 복합마감재의 VOCs/VVOCs 방출량과 실내농도에 관한 연구)

  • Yoon, Chang-Hyun;Kwon, Kyung-Woo;Park, Jun-Seok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.295-300
    • /
    • 2006
  • The purpose of this study is to evaluate the impacts of finishing materials' VVOCs and VOCs emission rates on indoor air quality of Apartment. VOCs emission rate of multi-layer finishing is predicted using the effective diffusion coefficient of each materials, and then the prediction is compared with Mock-up test and sample apartment house. From the results, the prediction of multi-layer finishing using the effective diffusion coefficient show good relation with the measured values.

  • PDF

Outside -20℃ Exposure Time Impact on Early Frost Damage (외기온 -20℃에 노출시간 변화가 콘크리트의 초기동해 피해에 미치는 영향)

  • Choi, Yoon-Ho;Han, Jun-Hiu;Lee, Hyuk-Ju;Lee, Young-Jun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.128-129
    • /
    • 2019
  • In this study, after exposing the normal concrete outside at $-20^{\circ}C$, when the above scored $20^{\circ}C$, we analyzed the limit points of the initial early frost damage to the concrete. As a result, it was confirmed that the degree of the upper part of the concrete when it was exposed outside the freezing point for 6 hours was zero.

  • PDF

A Study on Cold-Weather Curing Quality Management Based on Using Energy Saving Electronic Heater (에너지 절감형 전기히터를 활용한 동절기 양생품질 관리방안)

  • Jo, Man-Ki;Hong, Sung-Min;Park, Jong-Hun;Kim, Jin-Sik;Lee, Dong-Hyun;Cho, Seong-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.109-110
    • /
    • 2020
  • In This study, we tried to review an efficient curing method in consideration of safety and constructability among the problems of winter construction. In other words, as a result of the mock-up test, the measured value of carbon monoxide was 0 ppm in the case of an electric hot air fan. Since there is no carbon monoxide, problems such as suffocation are expected to be solved. In terms of temperature characteristics, electric hot air fans exhibited high thermal efficiency performance with a slight difference in upper/lower temperatures compared to the existing ones. In the future, we plan to conduct thermal efficiency evaluation through actual site performance verification. We will propose an efficient curing method through applicability evaluation.

  • PDF

Surrogate Model-Based Global Sensitivity Analysis of Components of a Test Mock-Up Nuclear Containment Building subjected to Internal Pressure (내압을 받는 축소규모 원전 격납건물 구성요소의 대리모델 기반 전역 민감도 분석)

  • Son, Hoyoung;Lee, Jong-Ryun;Ju, Bu-Seog
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.303-304
    • /
    • 2023
  • 확률론적 위험성 평가는 하중, 재료특성 등과 같은 불확실성 인자를 고려하여 구조물의 안전성을 평가하는 기법이지만 모든 불확실성을 고려하는 것은 현실적으로 불가능하다. 또한 원전 격납건물은 콘크리트, 철근, 라이너, 텐던이 복잡하게 결합되어 있다. 따라서 전역민감도 분석을 통해 격납건물의 불확실성 인자 검토하고 선정하는 작업은 필요하다. 따라서 본 연구는 대리모델을 기반으로 축소규모 원전 격납건물의 전역 민감도 분석을 수행하고 격납건물의 주요 영향인자를 분석하고자 한다. 유한요소 해석 모델을 기반으로 대리모델의 학습데이터를 생성하였으며 구축된 대리모델의 성능지표를 분석하였을 때 높은 회귀성능을 갖는 것으로 판단된다. 대리모델을 기반으로 전역 민감도 분석을 수행한 결과 콘크리트의 인장균열이 발생하는 내압수준에서 민감도 지수는 콘크리트의 압축강도가 높지만, 전체적인 내압 구간에서 민감도 지수는 텐던의 탄성계수 및 항복강도가 높은 것으로 나타났다.

  • PDF

Development of Loaded Stream Fire Extinguishing Systems for Underground Transmission Cables (지중송전선로 접속부용 미분무 강화액 소화설비의 개발연구)

  • Lee, Sung-Mo
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.93-98
    • /
    • 2008
  • Full-scale fire extinguishment tests were conducted to develop loaded stream fire extinguishing systems for protecting underground transmission cables. The dimension of test mock-up was 5.5m height${\times}3m$ width ${\times}6m$ length, and six 154kV OF cables were piled up. Gasoline was used to ignite cates. Linear heat detection cables were installed on top of 154 kV OF cable and discharge nozzles were installed on the top and sidewalls, respectively. As a result, both surface fires and deap-seated fires were extinguished successfully within the specified 3 minutes by discharging loaded stream agent.

A Study on the Evaluation of Lighting Performance in an Office Space (사무공간의 조명성능 평가에 관한 연구)

  • 김한성;김영민;김강수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.16-22
    • /
    • 2003
  • The purpose of this study was to provide visual evaluation data in a workstation space when different lighting types were applied. For the performance evaluation, Radiance program was used for simulations, and the mock-up room(15.0x11.6x3m) was used for the actual test. The results of this study were as follows; 1) When the inidirect lighting simulation data using Radiance was compared with the actual data in a small workstation space, there was a 6.5% difference. Therefore, Radiance program was proved to be useful for the evaluation of lighting performance. 2) Higher light levels (higher light ratio (%)) were recorded in the straddled layout and lower light levels (lower light ratio (%)) were recorded in the centered layout condition in most cases. 3) Also, the results show that the indirect luminaires and the straddled layouts provide higher uniformity, whereas the direct luminaires and the centered layouts have lower uniformity.