An Experimental Study on the Hydration Heat Control of Mass Concrete Using Heat Pipe

히트파이프를 이용한 매스콘크리트의 수화열 제어에 관한 실험 연구

  • BaeK, Dong-Il (Department of Civil Engineering, Pukyung National University)
  • 백동일 (부경대학교 건설공학부)
  • Published : 2007.12.31

Abstract

In order to eliminate the hydration heat of mass concrete, this paper reports the results of hydration heat control in mass concrete using the OCHP (Oscillating capillary tube heat pipe). In the summarized results of the mock up experiments, distributing the heat pipe at 300 mm intervals based on the center of the test specimen was the most effective. A 200 mm turn interval for the heat pipe was measured to be the most appropriate, taking into account the reinforcement placing at the actual site. Therefore, when the hydration heat control method using the heat pipe developed in this study is applied, not only canconstruction efficiency & a reduction in the necessary construction time be expected, but so can outstanding economical effects.

Keywords

References

  1. 강석화, 정한중, 박칠림 (1996). '매스콘크리트의 외부구속응력에 관한 검토', 한국콘크리트학회논문집, 제8권, 제5호, pp 111-122
  2. 권중현 (2000). '플라이애쉬를 사용한 수중불분리성 콘크리트의 수화열에 관한 연구', 한국해양공학회논문집, Vol 14, No 4, pp 30-34
  3. 김명식, 백동일, 염치선, 배원만, 김강민 (2006). OCHP를 이용한 매스콘크리트의 수화열 제어 연구', 2006년 한국구조물진단학회 봄 학술발표회지, pp 493-496
  4. 백동일 (2007). 히트파이프를 이용한 매스콘크리트 수화열 제어공법 개발, 부경대학교 박사학위논문
  5. 이장화, 변근주 (1995). '매스콘크리트의 수화온도의 합리적 평가를 위한 실험 및 해석 연구', 대한토목학회논문집, 제15권, 제2호, pp 337-346
  6. 한국콘크리트학회 (2003). 콘크리트 표준시방서, pp 257-287
  7. ACI Committee 207 (1970). Mass Concrete for Dam and Other Massive Struture. ACI Proc, Vol 6, Appril, pp 7-17