• Title/Summary/Keyword: mock location

Search Result 32, Processing Time 0.025 seconds

Title of the Paper in English (UHPC패널 현장 적용성 연구)

  • Yoon, Ju-Yong;Park, Yong-Kyu;Choi, Byung-Keol;Lee, Dae-Seek;Choi, Sang-Hun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.219-220
    • /
    • 2023
  • We attempted to examine field applicability by manufacturing panels using UHPC and conducting mock-up tests. Mock-up testing was conducted at the Busan location. To observe field applicability over a long period of time, it was produced and installed identically to actual panels.

  • PDF

Fake GPS Detection for the Online Game Service on Server-Side (모의 위치 서비스를 이용한 온라인 게임 악용 탐지 방안)

  • Han, Jaehyeok;Lee, Sangjin
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.27 no.5
    • /
    • pp.1069-1076
    • /
    • 2017
  • Recently $Pok\acute{e}mon$ GO implements an online game with location-based real time augmented reality on mobile. The correct play of this game should be based on collecting the $Pok\acute{e}mon$ that appears as the user moves around by foot, but as the popularity increases, it appears an abuse to play easily. Many people have used an application that provides a mock location service such as Fake GPS, and these applications can be judged to be cheating in online games because they can play games in the house without moving. Detection of such cheating from a client point of view (mobile device) can consume a large amount of resources, which can reduce the speed of the game. It is difficult for developers to apply detection methods that negatively affect game usage and user's satisfaction. Therefore, in this paper, we propose a method to detect users abusing mock location service in online game by route analysis using GPS location record from the server point of view.

An Automatic Diagnosis Methods for Impact Location Estimation

  • Kim, Jung-Soo;Lyu, Joon
    • Journal of IKEEE
    • /
    • v.3 no.1 s.4
    • /
    • pp.101-108
    • /
    • 1999
  • In this paper, a real time diagnostic algorithm for estimating the impact location by loose parts is proposed. It is composed of two modules such as the alarm discrimination module (ADM) and the impact-location estimation module(IEM). First, ADM decides whether the detected signal that triggers the alarm is the impact signal by loose parts or the noise signal. Second, IEM by use of the arrival time method estimates the impact location of loose parts. In order to validate the application of this method, the test experiment with a mock-up (flat board and reactor) system is performed. The experimental results show the efficiency of this algorithm even under high level noise and potential application to Loose Part Monitoring System (LPMS) for improving diagnosis capability in nuclear power plants.

  • PDF

Constructing Mock-up House and Evaluating Field Application for Development of Standard Long-Life Housing Model (장수명 공동주택 표준모델 개발을 위한 실험주택 건립과 현장적용성 평가)

  • Chin, Ju-Won;Jang, Han-Doo;Choi, Kyoung-Lyoul;Park, Joon-Young
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.167-172
    • /
    • 2008
  • The ultimate objective of this research is to develop the technologies for the construction of 100-year housing as the first task for improving housing environments. The technological development of 100-year housing makes it possible to advance construction technologies and part development, to develop long-life housing with durability and Flexibility responding to customers' needs for future living space. At first, for this purpose, the applications according to the types of the Standard Model of Long-life Housing are proposed to respond to the life-cycle of near-future demographic and social structure, and the construction of the Mock-up House execute based on the location selected during the 2nd year and the basic plan. Then the Standard Model of Long-life Housing are advanced and proposed through evaluating the field applicability of the Mock-Up House.

  • PDF

A Study on the Comparison of the Illuminance Values from Daylight Simulation and Mock-up Experiment for Suitable Application of Lighting Simulation (적합한 조명시뮬레이션 사용을 위한 주광 시뮬레이션과 Mock-up 실험 비교에 관한 연구)

  • Kim, Yu-Sin;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.35-44
    • /
    • 2010
  • Available daylight in inside offers comfortable view environment, and psychological and physical advantages to people in a room. Architectural design has a need for daylight prediction. But it is difficult to predict the illuminance values in daylight system. Using various Daylight simulation software is easy and simple, but we can find different results under the same conditions. This study compares with illuminance values from simulation (Lightscape 3.2, Relux 2007, Radiance 3.9) and Mock-up experiment with a same space and parameter of daylight (location of space and window, date, time and sky condition).

A Study on the Ventilation Effect by Establishment Location of Supply Opening and Exhaust Fan of Bathroom in Apartment House (공동주택 화장실의 급기구 및 배기팬 설치 위치에 따른 환기효과에 관한 연구)

  • 함진식
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2002.11a
    • /
    • pp.321-326
    • /
    • 2002
  • To design mechanical ventilation for bathroom of apartment houses where air supply and exhaust are taken Into consideration, mock-ups of ventilation systems, widely used in bathroom of apartment houses with an area of 100$m^2$, were made and installed in a laboratory, These ventilation mock-ups were available for control of air supply and exhaust, and the size of supply openings were 40cm$\times$1cm, 40cm$\times$3cm, 40cm$\times$5cm. They were installed at five positions, spaced 40cm at a height of 25cm from the floor. and the position of exhaust fans were four corners and center Exhaust fan established each one on corner of the ceiling and one in center. As result that measure ventilation effect by each condition, size of hole that supply air is big, and ventilation effect took effect to be good establishment location is low, Also, distance of exhaust fan is far with hole that supply air, ventilation effect took effect by superior thing.

  • PDF

A Study on the Comparison of the Illuminance Values from Lighting Simulation and Mock-up Experiment for Suitable Application of Lighting Simulation (조명시뮬레이션의 적절한 사용을 위한 Mock-up 실험 측정값과 주광 시뮬레이션 결과값 비교에 관한 연구)

  • Lim, Ji-Sun;Jun, Byung-Kuk;Kim, Yu-Sin;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.17-20
    • /
    • 2009
  • Available daylight in inside offers comfortable view environment, and psychological and physical advantages to people in a room. Architecture design has need of daylight prediction for reflection efficiently daylight. But it is difficult to predict the illuminance values in daylight system. Using various lighting simulation software is easy and simple, but we can find different results under the same conditions. This study compares with illuminance values from simulation (Lightscape 3.2, RELUX 2007, RADIANCE 3.9) and Mock-up experiment with the same space and parameter of daylight (location of space and window, date, time and sky condition).

  • PDF

A Study on the Ventilation Effect by Various Location of Air Intake and Exhaust Fan of Bathroom in Apartment Housing (공동주택 화장실의 급기구 및 배기팬 설치위치에 따른 환기효과에 관한 연구)

  • Ham Jin Sik;Lee Kwang Myung
    • Journal of the Korean housing association
    • /
    • v.15 no.5
    • /
    • pp.77-84
    • /
    • 2004
  • The mock-ups of ventilation system, which has been widely adopted for the bathroom with the area of 100 $m^2$ apartment housing, were established and tested to design mechanical ventilation for apartment housing bathroom where air supply exhaust are relatively important. These ventilation mock-ups were capable of controlling intake and exhaust, which has the size of supply openings as 40cm${\times}$1cm, 40cm${\times}$3cm, 40cm${\times}$5cm. They were established at five locations, spaced 40cm from each other at a height of 25cm from the floor. The exhaust fans were located at four corners and center of the ceiling. The results this ventilation effect measurement by different condition are showing that when the size of air supply is bigger and the location is lower, the effect of ventilation was relatively higher. In addition, as the distance between exhaust fan and air supply was farther, the ventilation effect were getting highly efficient.

An Application of the Novel Techniques Detecting Partial Discharge Employable to GIS Using Optical Sensor

  • Ryu, Cheol-Hwi;Jung, Seung-Yong;Koo, Ja-Yoon;Yeon, Man-Seung
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.3
    • /
    • pp.396-400
    • /
    • 2007
  • A novel technique has been proposed and related experimental works have been performed in order to detect the partial discharges and the location of the possible defects introduced into the Gas Insulated Switchgear. For this purpose, a prototype HY Pockels sensor has been developed and then employed in order to investigate its field applicability for finding the location of the defects using a 170kV GIS mock-up. Our proposed sensor enables us to measure the electric field variation due to the PD occurrence. In addition, the different PD patterns are observed, which might be dependant on the location and the distance of the sensor with respect to the PD source. Throughout this work, its linear response has been proved to be admissible as a function of the applied voltage. And also the position of the PD source might be distinguished by comparing the PD patterns.

An Automatic Diagnosis Method for Impact Location Estimation

  • Kim, Jung-Soo;Joon Lyou
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1998.10a
    • /
    • pp.295-300
    • /
    • 1998
  • In this paper, a real time diagnostic algorithm fur estimating the impact location by loose parts is proposed. It is composed of two modules such as the alarm discrimination module (ADM) and the impact-location estimation module(IEM). ADM decides whether the detected signal that triggers the alarm is the impact signal by loose parts or the noise signal. When the decision from ADM is concluded as the impact signal, the beginning time of burst-type signal, which the impact signal has usually such a form in time domain, provides the necessary data fur IEM. IEM by use of the arrival time method estimates the impact location of loose parts. The overall results of the estimated impact location are displayed on a computer monitor by the graphical mode and numerical data composed of the impact point, and thereby a plant operator can recognize easily the status of the impact event. This algorithm can perform the diagnosis process automatically and hence the operator's burden and the possible operator's error due to lack of expert knowledge of impact signals can be reduced remarkably. In order to validate the application of this method, the test experiment with a mock-up (flat board and reactor) system is performed. The experimental results show the efficiency of this algorithm even under high level noise and potential application to Loose Part Monitoring System (LPMS) for improving diagnosis capability in nuclear power plants.

  • PDF