• 제목/요약/키워드: mock circulation

검색결과 36건 처리시간 0.02초

인공심장 판막의 수력학적 특성 (Design of a Hydrodynamic Mock Circulation System For Prosthetic Heart Valve Testing)

  • ;서수원;김기준;;김희찬;김인영;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 춘계학술대회
    • /
    • pp.146-151
    • /
    • 1993
  • A new hydrodynamic mock circulation system was developed, which can test prosthetic heart valves of various sizes in order to obtain valve parameters, such as pressure drop, regurgitation and valve performance index with a high reproducibility. High reproducibility can be obtained only under equal testing conditions, i.e., the compliance, resistance and inertance of the mock circulation system must be constant parameter estimation using actual pressure and flow data was applied to calculate these systemic variables in order to adjust them to create the necessary equal testing conditions.

  • PDF

혈관 삽입용 초소형 작동형 내시경의 개발(II) - 시스템 설계, 제작 및 체외 성능 분석 - (Development of Intravascular Micro Active Endoscope(II) -System Design, Fabrication and In-vitro Evaluation-)

  • 장준근;정석;이용구
    • Tribology and Lubricants
    • /
    • 제15권3호
    • /
    • pp.278-286
    • /
    • 1999
  • To predict the behavior of the intravascular micro active endoscope in the real human vascular system, a human mock circulation system was developed. The intravascular micro active endoscope which consists of micro active bending catheter and micro drug infusion catheter was driven in the velocity, Re number and temperature controlled flow. The three SMA (Shape Memory Alloy) zigzag type spring in the micro active bending catheter was heated by the electric current generated by PWM controller, and the shape memory effect made the actuator bend to any direction. The micro drug infusion catheter was driven through the inner hole of the micro active bending catheter. A mock circulation system is shaped from Ascending Arota to Femoral artery according to a human data (the data contains many vascular sizes and hydrographs of many control points). We developed a vascular model with glass and silicone tubes, and set the flow system with circulation parts, flow settling parts, and lots of valves. The heater and heat-controller was added to the How system to centre! the temperature of the How at 36.5$^{\circ}C$. The result showed that the developed intravascular micro active endoscope could be induced to any point in the vascular model.

인공신경망을 이용한 좌심실보조장치의 제어 (Control of Left Ventricular Assist Device using Artificial Neural Network)

  • 류정우;김훈모;김상현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.260-266
    • /
    • 1996
  • In this paper, we presents neural network identification and control of highly complicated nonlinear Left Ventricular Assist Device(LVAD) system with a pneumatically driven mock circulation system. Generally the LVAD system need to compensate nonlinearities. Hence, it is necessary to apply high performance control techniques. Fortunately, the neural network can be applied to control of a nonlinear dynamic system by learning capability. In this study, we identify the LVAD system with Neural Network Identification. Once the NNI has learned the dynamic model of LVAD system, the other network, called Neural Network Controller(NNC), is designed for control of a LVAD system. The ability and effectiveness of identifying and controlling a LVAD system using the proposed algorithm will be demonstrated by computer simulation.

  • PDF

송아지에 이식한 공기구동형 인공심장의 혈역학적 연구 (Hemodynamic study of Pneumatic Artificial Heart Implanted in Calves)

  • 박표원
    • Journal of Chest Surgery
    • /
    • 제23권3호
    • /
    • pp.438-451
    • /
    • 1990
  • Pneumatic total artificial heart[TAH] has been clinically applied for the purpose of permanent or temporary use followed by cardiac transplantation in the patients with end stage heart diseases. In spite of the good durability of the pneumatic TAH, thrombus formation, bleeding and infection resulted in death. The Tomasu heart, which is a type of pneumatic TAH, was used in this study. This model is a modified Jarvik heart and consists of atrial cuffs, outflow vascular grafts and thin-layer seamless diaphragm type of ventricles. Cardiac outputs of the left artificial heart were measured by Donovan`s mock circulation under variable conditions of driving parameters, and an experimental artificial heart implantation was performed in 4 calves to observe the changes of hemodynamic parameters in early postoperative period and hematologic and bio-chemical changes in a long-term survival case. In the mock circulation test, cardiac output of the heart was increased with the increase of the left atrial pressure and left driving pressure. Maximum cardiac output was obtained at the heart rate of 120 to 130/min and percent systole of 40 to 45Zo under the condition of a constant left driving pressure of 180mmHg and left atrial pressure of 10mmHg. During the first 24 hours of TAH pumping, driving pressure ranged from 178$\pm$5mmHg to 187$\pm$8mmHg for the left heart and from 58$\pm$6mmHg to 78$\pm$28mmHg for the right heart. The Mean arterial pressure significantly increased between 2 and 8 hours after the start of pumping. The survival time ranged from 27 hours to 46 days. The causes of death were respiratory failure in 2 cases, mechanical valve failure in one, and left ventricular outflow obstruction due to thrombus in a 46-day survival case. This study demonstrated that Tomasu artificial heart operated effectively during the first 24 hours of artificial heart pumping, but thrombus formation around the valve holding area was the main problem in long-term survival case.

  • PDF

인공심장용 무선에너지 전송 시스템의 개발 (Development of transcutaneous energy transmission system for implantable total artificial heart)

  • 이우철;안재목;이상훈;민병구
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.762-767
    • /
    • 1991
  • To make electromechanical total artificial heart implantable inside the body, transcutaneous energy transmission system was designed and simulated by using PSPICE program. The fabricated system was evaluated by using Mock circulation system and showed comparable performance with the D.C power supply

  • PDF

Time-Varying Hemodynamic Characteristics Simulation using Computerized Mock Circulatory Loop System with Servo Flow Regulator

  • Moon, Youngjin;Son, Kuk Hui;Choi, Jaesoon
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권6호
    • /
    • pp.264-270
    • /
    • 2015
  • A mock circulatory loop system has been developed to construct a simulator for trainees in cardiopulmonary bypass systems or to simulate a test environment for cardiac-assist devices. This paper proposes a computerized mock circulatory loop system whose node is modularized by using a servo control flow regulator to simulate dynamic change of the hemodynamic status. To observe the effect of time-varying resistance, one with hemodynamic properties, the proposed system replicates the planned cross-sectional areas of the outlet of a ventricular assist device in terms of voltage input of a servo valve. The experiment is performed (1) for steady-input commands of selected area sizes and (2) for dynamic commands such as monotonous increase and decrease, and oscillatory functions of the voltage input, and a computer program based on LabVIEW (National Instruments, Austin, USA) processes every measured data and control command to the servo valve. The results show that the pressure and flow at the target points with respect to time-varying resistance match intuitive estimation: the pressure at the outlet and the pressure drop between both sides of the valve increased and the flow at the outlet decreased for increased resistance.

체외 순환 보조 장치 위한 공기방울 감지 장치 개발 (Development of Bubble Detector for Extracorporeal Circulation Support System)

  • 이혁수
    • 융합신호처리학회논문지
    • /
    • 제11권4호
    • /
    • pp.298-302
    • /
    • 2010
  • 체외 순환 보조 장치는 호흡부전 및 심부전 등에 사용하는 장치이며 세계적으로 많은 연구 개발과 임상에의 사용이 계속되고 있다. 이 장치들을 사용할 때 주의해야할 사항중 하나는 공기 색전증이다. 공기 색전증은 정맥혈내로 공기가 들어갈 수 있는 여러 가지 수술 과정 및 진단 과정의 합병증으로 일어날 수 있으며, 수술부위가 심장보다 위치, 수술 과정 중 체강, 체외 순환 보조 장치를 사용할 때 공기의 유입이 생길 수 있다. 이러한 문제를 해결하기위해 비유전율 상수의 변화를 이용한 공기방울 감지 장치를 개발했다. 모의순환 장치에서 실험해본 결과 튜브 안의 공기 양에 따라 신호의 차를 분명하게 보여주어 공기방울을 감지할 수 있었다.

Valved Conduit with Glutaraldehyde-Fixed Bovine Pericardium Treated by Anticalcification Protocol

  • Lim, Hong-Gook;Kim, Gi Beom;Jeong, Saeromi;Kim, Yong Jin
    • Journal of Chest Surgery
    • /
    • 제47권4호
    • /
    • pp.333-343
    • /
    • 2014
  • Background: A preclinical study was conducted for evaluating a valved conduit manufactured with a glutaraldehyde (GA)-fixed bovine pericardium treated using an anticalcification protocol. Methods: Bovine pericardia were decellularized, fixed with GA in an organic solvent, and detoxified. We prepared a valved conduit using these bovine pericardia and a specially designed mold. The valved conduit was placed under in vitro circulation by using a mock circulation model, and the durability under mechanical stress was evaluated for 2 months. The valved conduit was implanted into the right ventricular outflow tract of a goat, and the hemodynamic, radiologic, histopathologic, and biochemical results were obtained for 6 months after the implantation. Results: The in vitro mock circulation demonstrated that valve motion was good and that the valved conduit had good gross and microscopic findings. The evaluation of echocardiography and cardiac catheterization demonstrated the good hemodynamic status and function of the pulmonary xenograft valve 6 months after the implantation. According to specimen radiography and a histopathologic examination, the durability of the xenografts was well preserved without calcification at 6 months after the implantation. The calcium and inorganic phosphorus concentrations of the explanted xenografts were low at 6 months after the implantation. Conclusion: This study demonstrated that our synergistic employment of multiple anticalcification therapies has promising safety and efficacy in the future clinical study.

인공신경망 Feedforward 제어기를 이용한 좌심실 보조장치의 제어실험 (Control of Left Ventricular Assist Device Using Neural Network Feedforward Controller)

  • 정성택;김훈모;김상현
    • 한국정밀공학회지
    • /
    • 제15권4호
    • /
    • pp.83-90
    • /
    • 1998
  • In this paper, we present neural network for control of Left Ventricular Assist Device(LVAD) system with a pneumatically driven mock circulation system. Beat rate(BR), Systole-Diastole Rate(SDR) and flow rate are collected as the main variables of the LVAD system. System modeling is completed using the neural network with input variables(BR, SBR, their derivatives, actual flow) and output variable(actual flow). It is necessary to apply high perfomance control techniques, since the LVAD system represent nonlinear and time-varing characteristics. Fortunately. the neural network can be applied to control of a nonlinear dynamic system by learning capability In this study, we identify the LVAD system with neural network and control the LVAD system by PID controller and neural network feedforward controller. The ability and effectiveness of controlling the LVAD system using the proposed algorithm will be demonstrated by experiment.

  • PDF

인공신경망 Feedforward제어기를 이용한 좌심실보조장치의 제어실험 (Control of Left Ventricular Assist Device using Neural Network Feedback Feedforward Controller)

  • 정성택;류정우;김상현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.150-155
    • /
    • 1997
  • In this paper,we present neural network for control of Left Ventricular Assist Device(LVAD)system with a pneumatically driven mock cirulation system. It is necessary to apply high perfomance control techniques, since the LVAD system represent nonlinear and time-varing characteristics. Fortunately, the neural network can be applied to control of a nonliner dynamic system by learning capability. In this study,we identify the LVAD system with neural network and control the LVAD system by PID controller and neural network feedforward controller. The ability and effectiveness of controlling the LVAD system using the proposed algorithm will be demonstrated by computer simulation and experiment.

  • PDF