References
- Wieting, D. W., Akers, W., Feola, M., and Kennedy, J. H., "Analysis of a variable volume intra-aortic balloon pump in a mock circulatory system," J. Biomech., vol. 4, pp. 37-44, 1971. https://doi.org/10.1016/0021-9290(71)90014-5
- Donovan, F., "Design of a hydraulic analog of the circulatory system for evaluating artificial hearts," Artif. Cell. Blood Sub., vol. 3, pp. 439-449, 1975.
- Guyton, A. C., and Hall, J. E., Textbook of medical physiology, 10 ed. Saunders, Philadelphia, ch. vol. 17, pp. 175-182, 2001.
- Ferrari, G., De Lazzari, C., Kozarski, M., Clemente, F., Gorc-zynska, K., Mimmo, R., Monnanni, E., Tosti, G., and Guaragno, M., "A hybrid mock circulatory system: testing a prototype under physiologic and pathological conditions," ASAIO j., vol. 48, pp. 487-494, 2002. https://doi.org/10.1097/00002480-200209000-00009
- Timms, D., Hayne, M., McNeil, K., and Galbraith, A., "A complete mock circulation loop for the evaluation of left, right, and biventricular assist devices," Artif. organs, vol. 29, pp. 564-572, 2005. https://doi.org/10.1111/j.1525-1594.2005.29094.x
- Timms, D. L., Gregory, S. D., Greatrex, N. A., Pearcy, M. J., Fraser, J. F., and Stein- seifer, U., "A compact mock circulation loop for the in vitro testing of cardiovascular devices," Artif. Organs, vol. 35, pp. 384-391, 2010.
- Legendre, D., Fonseca, J., Andrade, A., Biscegli, J. F., Manrique, R., Guerrino, D., Prakasan, A. K., Ortiz, J. P., and Lucchi, J. C., "Mock circulatory system for the evaluation of left ventricular assist devices, endoluminal prostheses, and vascular diseases," Artif. Organs, vol. 32, pp. 461-467, 2008. https://doi.org/10.1111/j.1525-1594.2008.00569.x
- Wu, Y., Allaire, P. E., Tao, G., and Olsen, D., "Modeling, estimation, and control of human circulatory system with a left ventricular assist device," IEEE Trans. Contr. Syst. Tech., vol. 15, pp. 754-767, 2007. https://doi.org/10.1109/TCST.2006.890288
- Conlon, M. J., Russell, D. L., and Mussivand, T., "Development of a mathematical model of the human circulatory system," Ann. Biomed. Eng., vol. 34, pp. 1400-1413, 2006. https://doi.org/10.1007/s10439-006-9164-y
- Geertsema, A. A., Rakhorst, G., Mihaylov, D., Blanksma, P. K., and Verkerke, G. J., "Development of a numerical simulation model of the cardiovascular system," Artif. organs, vol. 21, pp. 1297-1301, 1997.
- Baloa, L., Boston, J., and Antaki, J., "Elastance-based control of a mock circulatory system," Ann. Biomed Eng., vol. 29, pp. 244-251, 2001. https://doi.org/10.1114/1.1355275
- Liu, Y., Allaire, P., Wood, H., and Olsen, D., "Design and initial testing of a mock human circulatory loop for left ventricular assist device performance testing," Artif. organs, vol. 29, pp. 341-345, 2005. https://doi.org/10.1111/j.1525-1594.2005.29058.x
- Hwang, C., Jeong, G. S., Jung, M. W., Kang, J. S., Lee, J. J., Park, Y. D., Lee, K. B., and Sun, K., "Development of wearable electropneumatic biventricular assist device," ASAIO J., vol. 51, pp. 38A, 2005.
- Merritt, H. E., Hydraulic control systems, Wiley New York, 1967.