• Title/Summary/Keyword: mobile emission

Search Result 163, Processing Time 0.026 seconds

A New Analytical Method for Fluoroquinolones in Fisheries Products by High Performance Liquid Chromatography (HPLC를 이용한 어패류 중의 fluoroquinolone계 항균제의 분석법)

  • Jo Mi-Ra;Kim Poong-Ho;Lee Hee-Jung;Lee Tae-Seek
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.39 no.2
    • /
    • pp.59-65
    • /
    • 2006
  • Fluoroquinolones are the most common group of antibacterial agents currently used in the Korean aquaculture industry, and use of these agents has been increasing steadily. High performance liquid chromatography (HPLC) with fluorescence detection was used for the simultaneous determination of five fluoroquinolones in fish and shellfish: ofloxacin (OFL), pefloxacin (PEF), norfloxacin (NOR), ciprofloxacin (CIP), and enrofloxacin (ENRO). Fish and shellfish muscle was homogenized, and protein, lipid, and low molecular weight pigments were then excluded from the homogenate. The final eluates were analyzed by HPLC equipped with a Shiseido UG-120 type C18 reverse-phase column ($4.6{\times}250 mm$, $5{\mu}m$) and a fluorescence detector (excitation at 280 nm, emission at 450 nm). The mobile phase was 0.1 M phosphoric acid and acetonitrile solution (91:9, v/v) and tetrahydrofuran (THF) was added to it at a rate of 5 mL per a liter of the mobile phase. Adequate chromatography separation was obtained using the above method. Average recoveries of fortified samples at levels from 0.05 to 0.5 mg/kg were $72.3{\pm}2.5-84.5{\pm}1.2%$ for OFL, $82.7{\pm}3.3- 109.3{\pm}7.5%$ for NOR, $85.3{\pm}6.6-116.0{\pm}7.9%$ for PEF, $76.0{\pm}4.3-109.3{\pm}12.4%$ for CIP, and $78.7{\pm}5.9-100.0{\pm}9.8%$ for ENRO. The limit of detection of OFL was $5{\mu}g/L$, the others were $1{\mu}g/L$. We concluded that the new analytical method was suitable for the determination of fluoroquinolones in fish and shellfish.

Development of a Microwave Radiometer for Remote Sensing of Water Surface Temperature (수면 온도 원격탐사용 마이크로파 라디오미터의 개발)

  • Son, Hong-Min;Youn, Jeong-Beam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.9
    • /
    • pp.1107-1115
    • /
    • 2012
  • This paper presents the development processes of a microwave radiometer for remote sensing of water surface temperature. Achieving the measurement accuracy within $2^{\circ}C$ for water surface temperature of $5{\sim}30^{\circ}C$, the requirements and specifications of the microwave radiometer and its receiver are drawn. The receiver with high gain, high sensitivity is designed and implemented. The receiver has the bandwidth of 50 MHz, the system gain of 45.2 dB and the sensitivity of 0.56K at 5.02 GHz. The effectiveness of the developed microwave radiometer in the measurement of water surface temperature is demonstrated experimentally. The results show the microwave radiometer can detect water surface temperature for $7.5{\sim}18^{\circ}C$ within the accuracy of $0.45^{\circ}C$.

The PM2.5 Emission Source Contribution Analysis using The PMF Model in Urban Area (PMF 모델을 이용한 도심지역 PM2.5 오염원 기여도 분석)

  • Koo, Tai-Wan;Hong, Min-Sun;Moon, Su-Ho;Kim, Ho-Jung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.905-914
    • /
    • 2019
  • In this study, The PMF model was used to identify pollutant sources and their contribution to pollution sources of $PM_{2.5}$. The contribution of A city to each source was 19.8% for Secondary Sulfate, followed by Mobile 19.5%, Industry 16.0%, Biomass Buring 14.1%, Secondary Nitrate 14.1%, Oil Combustion 11.6%, Aged Sea Salt 2.6%, Soil 2.5% and so on. Sulfate and Ammonium concentrations were the highest contributing sources in the source profile, which was analyzed to be Secondary Aerosols produced by Photochemical Reactions of gaseous precursors (SOx and ammonia gas) in the atmosphere.

Estimation of Domestic Greenhouse Gas Emission of Refrigeration and Air Conditioning Sector adapting 2006 IPCC GL Tier 2b Method (국내 냉동 및 냉방부문 온실가스 배출량 산정 - 2006 IPCC GL Tier 2b 적용 -)

  • Shin, Myung-Hwan;Lyu, Young-Sook;Seo, Kyoung-Ae;Lee, Sue-Been;Lim, Cheolsoo;Lee, Sukjo
    • Journal of Climate Change Research
    • /
    • v.3 no.2
    • /
    • pp.117-128
    • /
    • 2012
  • The Government of South Korea has continued its effort to fixate virtuous circle of economic growth and climate change response to cope with international demands and pressure to commitment for greenhouse gas reduction effectively. Nationally, Korean Government has established "Enforcement of the Framework Act on Low carbon, Green Growth"(2010. 4. 13) to implement national mid-term GHG mitigation goal(30% reduction by 2020 compare to BAU), which established the foundation for phased GHG mitigation by setting up the sectoral and industrial goal, adopting GHG and Energy Target Management System. Also, follow-up measures are taken such as planning and control of mid-term and short-term mitigation target by detailed analysis of potential mitigation of sector and industry, building up the infrastructure for periodic and systematic analysis of target management. Likewise, it is required to establish more accurate, reliable and detailed sectoral GHG inventory for successfully establishment and implement the frame act. In comparison to the $CO_2$ emission, Especially fluorinated greenhouse gases (HFCs, PFCs, $SF_6$) are lacking research to build the greenhouse gas inventories to identify emissions sources and collection of the applicable collection activities data. In this study, with the refrigeration and air conditioning sector being used to fluorine refrigerant(HFCs) as the center, greenhouse gas emission estimation methodology for evaluating the feasibility of using this methodology look over and mobile air conditioning, fixed air conditioning, household refrigeration equipment, commercial refrigeration equipment for the greenhouse gas emissions were calculated. First look at in terms of methodology, refrigeration and air conditioning sector GHG emissions in developing country-specific emission factors and activity data of the industrial sector the construction of the DB is not enough, it's 2006 IPCC Guidelines Tier 2a (emission factor approach) rather than the Tier 2b (mass balance approach) deems appropriate, and each detail by process, sectoral activity data more accurate, if DB is built Tier 2a (emission factor approach) can be applied will also be judged. Refrigeration and air conditioning sector in 2009 due to the use of refrigerant greenhouse gas emissions ($CO_2eq.$) assessment results, portable air conditioner 1,974,646 ton to year, fixed-mount air conditioner 1,011,754 ton to year, household refrigeration unit 4,396 ton to year, commercial refrigeration equipment 1,263 ton to year was estimated to total 2,992,037 tons.

A Study on the Comparison of Air Pollutants Emissions according to Three Averaging Methods of Vehicular Travel Speed (자동차 평균통행속도 적용방식에 따른 대기오염 배출량 비교 연구)

  • Cho Kyu-Tak
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.4
    • /
    • pp.401-411
    • /
    • 2005
  • This study was conducted to develop a method to be able to estimate the vehicular emissions according to spatial scales-Seoul province, 25 counties and hundreds of grids $(1km{\times}1km)$. First, the emissions at each spatial scale was calculated by using the road network and the travel volume and speed of each link modeled by travel demand model (TDM). Second, the emission at each spatial scale was calculated on the basis of average speeds estimated by using three kinds of averaging method. These are called the provincial, volume-delay function (VDF) and zonal method, respectively. Third, three kinds of emissions and those by TDM are compared each other at three spatial scales. In Seoul (provincial scale), three kinds of emissions are less than those by TDM, but the differences of TDM from three speed averaging methods (SAMs) are small. The relative ratios of three SAMs to TDM are $88\~90\%\;in\;CO,\;99\~100\%\;in\;NOx,\;84\~85\%$ in VOCs. At county scale, NOx among three pollutants showed the highest correlation between TDM and three SAMs and the zonal method among three SAMs was proven to be the highest correlation with TDM. NOx showed the coefficients $(R^2)$ greater than 0.9 in all three SAMs but CO and VOC showed the coefficients $(R^2)$ greater than 0.9 in only zonal method. Slopes of co..elations of all pollutants showed the values close to '1' in zonal method. In the other two SAMs, slopes of NOx showed the values close to '1', but those of CO and VOC showed the values less than 0.85. At grid scale, correlations between TDM and three SAMs were not high. CO showed $0.68\~0.77\;in\;R^2s\;and\;58\~0.68$ in slopes. NOx showed $0.90\~0.94\;in\;R^2s\;and\;0.86\~0.94$ in slopes. VOC showed $0.56\~0.70\;in\;R^2s\;and\;0.48\~0.57$ in slopes. There are not high correlations between TDM and three SAMs in grid scale. This study showed that there is the most suitable method for calculating the average travel speed at each spatial scale and it is thought that the zonal method is more suitable than the VDF or provincial method.

Design and Implementation of an Emotion Recognition System using Physiological Signal (생체신호를 이용한 감정인지시스템의 설계 및 구현)

  • O, Ji-Soo;Kang, Jeong-Jin;Lim, Myung-Jae;Lee, Ki-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.1
    • /
    • pp.57-62
    • /
    • 2010
  • Recently in the mobile market, the communication technology which bases on the sense of sight, sound, and touch has been developed. However, human beings uses all five - vision, auditory, palatory, olfactory, and tactile - senses to communicate. Therefore, the current paper presents a technology which enables individuals to be aware of other people's emotions through a machinery device. This is achieved by the machine perceiving the tone of the voice, body temperature, pulse, and other biometric signals to recognize the emotion the dispatching individual is experiencing. Once the emotion is recognized, a scent is emitted to the receiving individual. A system which coordinates the emission of scent according to emotional changes is proposed.

Analysis of Benzo(a)pyrene in Red Ginseng Beverage (홍삼음료 증 벤조피렌 분석)

  • Hu, Soo-Jung;Jin, Sun-Hee;Choi, Dong-Mi
    • Journal of Food Hygiene and Safety
    • /
    • v.23 no.1
    • /
    • pp.26-30
    • /
    • 2008
  • Polycyclic Aromatic Hydrocarbons(PAHs) contamination arises from several source including processing of food(smoking, direct drying, cooking) and environmental contamination of air, water or soil. A red ginseng is produced by steaming the root followed by drying. The methodology involved extraction with n-hexane and washing with water, clean-up on Sep-Pak Florisil Cartridges and determination by HPLC/FLD. The mobile phase was a mixture of acetonitrile and water in 8:2 by the isocratic elution and the excitation wavelength of fluorescence detector was 294 nm and its emission wavelength was 404 nm. The average recovery was about 105% and the relative standard deviation was 0.5. The levels of benzopyrene in the selected red ginseng beverage samples were not detected.

Study on Extraction Condition and Analysis Methods of Benzopyrene in Black Ginseng (흑삼에서 벤조피렌의 추출 조건 및 분석 방법에 관한 연구)

  • Cho, Young-Ho;Song, Kyu-Yong;Baek, Myoung-Ki;Lee, Jong-Wha;Lee, Gye-Won
    • YAKHAK HOEJI
    • /
    • v.56 no.3
    • /
    • pp.145-151
    • /
    • 2012
  • To develop fundamental data of herbal materials with heat treatment, we studied analytical and extraction methods of benzopyrene in black ginseng and validated by HPLC analysis. Benzopyrene was successfully separated in mobile phase of acetonitrile:water (80 : 20) and detection of excitation 294 nm, emission 404 nm. The calibration curve of benzopyrene was linear over the concentration range of 1.17~37.50 ng/ml with correlation coefficient of above 0.999. The limit of detection (LOD) and quantitation (LOQ) of benzopyrene was 0.25 and 0.75 ng/ml, respectively. Hexane extraction method was used as a new extraction method for benzopyren and the efficient of extraction was over 95%. In conclusion, analytical method and extraction method were suitable for the determination of benzopyrene in the black ginseng and could be applied to fundamental study and guideline of herbal materials with heat treatment.

PAHs Source Fingerprints for Municipal Incinerator, Motor Vehicle Fuels and Industrial Boilers Emission (발생원별에 따른 PAHs 배출특성)

  • 박찬구;윤중섭;김민영;손종열;모세영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.3
    • /
    • pp.331-343
    • /
    • 2004
  • The results of individual PAH source profiles that can be applied to receptor model are as follows. The sum of 16 PAH concentrations was 391.41 ng/S㎥ in a tunnel. Phenanthrene was the most abundant compound among 16 PAH, and then pyrene, fluoranthene, anthracene, and naphthalene can be seen in elevated contents. 11,056.61 ng/S㎥ of 16 PAH concentrations in BC oil boiler was two times higher than 6,582.57 ng/S㎥) of those in LNG boiler. Naphthalene was the most abundant compound in both facilities. Phenanthrene, anthracene, and acenaphthylene were the second dominant compound group in order from both facilities. BC oil boiler had relatively high concentration of pyrene compared to LNG boiler that had high concentration of fluorene and did not detect pyrene. The sum of 16 PAH concentrations emitted from MSW incinerators after APCD (air pollution control device) was three times higher than those from MSW incinerators before APCD. However, the concentrations of more than 4-ring PAH compounds (e.g., benzo (a)anthracene) before APCD were higher than those after APCD. This fact implies that PAHs generated by combustion process are eliminated in APCD and they are continuously produced in stack or atmosphere by PAHs precursors.

Simplified HPLC Method for the Determination of Mirtazapine in Human Plasma and Its Application to Single-dose Pharmacokinetics

  • Gwak Hye-Sun;Lee Na-Young;Chun In-Koo
    • Biomolecules & Therapeutics
    • /
    • v.14 no.1
    • /
    • pp.40-44
    • /
    • 2006
  • Mirtazapine is an antidepressant agent with dual action on both the noradrenergic and serotonergic neurotransmitter systems. A simple high performance liquid chromatographic method has been developed and validated for the quantitative determination of mirtazapine in human plasma. A reversed-phase Cl8 column was used for the determination of mirtazapine with a mobile phase composed of 0.01M ammonium acetate solution (pH 4.2) and acetonitrile (75:25, v/v%) at a flow rate of 1.2 mL/min. Terazosin hydrochloride was used as an internal standard. The fluorescence detector was set at excitation and emission wavelengths of 290 and 350 nm, respectively. Intra- and inter-day precision and accuracy were acceptable for all quality control samples including the lower limit of quantification of 3 ng/mL. Mirtazapine was stable in human plasma under various storage conditions. This method was used successfully for a pharmacokinetic study using plasma samples after oral administration of a single 30 mg dose as mirtazapine base to 8 healthy volunteers. The maximum plasma concentration of mirtazapine was $64.1{\pm}28.0ng/mL$ at 1.8 h, and the area under the curve and elimination half-life were calculated to be $674.1{\pm}218.5ng\;h/mL\;and\;23.4{\pm}3.8h$, respectively.