• 제목/요약/키워드: mmWave

검색결과 1,014건 처리시간 0.032초

A 3-stage Wideband Q-band Monolithic Amplifier for WLAN

  • Kang, Dong-Min;Lee, Jin-Hee;Yoon, Hyung-Sup;Shim, Jae-Yeob;Lee, Kyung-Ho
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -2
    • /
    • pp.1054-1057
    • /
    • 2002
  • The design and fabrication of Q-band 3-stage monolithic microwave integrated circuit(MMIC) amplifier for WLAN are presented using 0.2$\square$ AIGaAs/lnGaAs/GaAs pseudomorphic high electron mobility transistor (PHEMT). In each stage of the MMIC, a negative feedback is used for both broadband and good stability. The measurement results are achieved as an input return loss under -4dB, an output return loss under -10dB, a gain of 14dB, and a PldB of 17dBm at Q-band(36~44GHz). These results closely match with design results. The chip size is 2.8${\times}$1.3mm$^2$. This MMIC amplifier will be used as the unit cell to develop millimeter-wave transmitters for use in wideband wireless LAN systems.

  • PDF

디퓨저 확대각이 임계노즐의 임계압력비에 미치는 영향 (The Influence of the Diffuser Divergence Angle on the Critical Pressure of a Critical Nozzle)

  • 김재형;김희동;박경암
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.131-134
    • /
    • 2002
  • Compressible gas flow through a convergent-divergent nozzle is choked at the nozzle throat under a certain critical pressure ratio, and then being no longer dependent on the pressure change in the downstream flow field. In practical, the flow field at the divergent part of the critical nozzle can affect the effective critical pressure ratio. In order to investigate details of flow field through a critical nozzle, the present study solves the axisymmetric, compressible, Wavier-Stokes equations. The diameter of the nozzle throat is D=8.26mm and the half angle of the diffuser is changed between $2^{\circ}\;and\;10^{\circ}$ Computational results are compared with the previous experimental ones. The results obtained show that the divergence angle is significantly influences the critical pressure ratio and the present computations predict the experimented discharge coefficient and critical pressure ratio with a good accuracy. It is also found that a nozzle with the half angle of $4^{\circ}$ nearly predicts the theoretical critical pressure ratio.

  • PDF

기계식 一葉심장밸브의 동적거동 해석 (Dynamic Behavior Analysis of Mechanical Monoleaflet Heart Valve Prostheses)

  • 천길정
    • 대한기계학회논문집
    • /
    • 제16권11호
    • /
    • pp.2090-2097
    • /
    • 1992
  • 본 연구에서는 밸브판의 거동을 2차의 회전계로 간주하고, 양력 및 항력(drag force)을 구하는데 있어 Reif등이 구한것과 동일한 방법을 이용하되 정지핀에 의해 그 최대 열림각이 제한을 받는 물리적 사실을 고려하고, 밸브를 통과하는 유량도 단위 입 력이 아닌 정현파(sine wave)로 간주하여 밸브판의 동적거동을 해석하였다. 해석대 상의 밸브 모델로는 Bjork-Shiley 27mm 1엽 밸브를 선정하였다.

연속파형 Nd:YAG 레이저를 이용한 SCM4강의 표면경화에 관한 연구 (A Study on the Surface Hardening of SCM4 Steel Using a Continuous Wave Nd:YAG Laser)

  • 나기대;신병헌;신호준;유영태
    • 한국공작기계학회논문집
    • /
    • 제16권5호
    • /
    • pp.24-32
    • /
    • 2007
  • Laser surface hardening is beneficially used for surface treatment of structural steel. Due to very rapid heating and cooling rates, structural low-alloy steel(SCM4) can be hardened as self quenching. The aim of this research project is to improve the influence of the process laser parameters: laser power, spot size, surface roughness, and traverse speed. The laser beam is allowed to scan on the surface of the workpiece at the constant power(1095W), varying the traverse speed at 0.3m/min, 0.5m/min and 0.8m/min. The optical lens with the elliptical profile is designed to obtain a wide surface hardening area with uniform hardness. From the results of the experiment, it has been shown that the stable hardness is about 600$\sim$700Hv, when the laser power, focal position and the traverse speed are P=1095W, z=0mm and v=0.3m/min.

직선집속 PVDF 초음파트랜스듀서의 제작과 응용 I. 제작 및 특성평가 (Fabrication of PVDF Line Focus Ultrasonic Transducer and its Application I. Fabrication and Characteristics Evaluation)

  • 윤혁준;하강열;김무준
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1999년도 학술발표대회 논문집 제18권 1호
    • /
    • pp.387-390
    • /
    • 1999
  • 누설탄성표면파(Leaky Surface Acoustic Wave : LSAW) 측정에 사용하는 것을 목적으로 PVBF 압전막을 이용하여 직선집속 초음파트랜스듀서를 제작하고 그 특성을 평가하였다. 제작은 한쪽 면이 원통형 구조를 갖는 구리, 알루미늄, 3mmPVC-에폭시 3가지 재료를 배면층으로 사용하여 각각에 PVDF를 부착시켜서 수중에 음파를 방사하도록 구성하였고, 특성평가는 임펄스응답 특성과 음장 특성으로 나누어서 평가하였다. 임펄스응답 특성은 제작한 3종류의 집속 초음파트랜스듀서에 대해 실험적으로 측정하고, Mason 등가회로1)를 이용한 이론적 해석결과와 비교하였다. 음장특성 측정실험은 구리를 배면체로 하여 제작한 집속 초음파트랜스듀서에 대해서 실시하였고, 그 이론적인 계산결과는 Raylelgh-Somme-rfeld 회 절이론2)을 도입하여 초점면에 형성되는 음압분포를 계산하는 것으로 얻어졌다. 실험은 펄스 초음파 송수기 및 $2{\mu}m/step$으로 이동하는 정밀 x-y-z 스테이지를 컴퓨터에 연결하여 자동 측정하는 것으로 수행되었는데, 그 결과는 이론 해석결과와 비교적 잘 일치하였다.

  • PDF

압전회전작동기를 이용한 스텝모터에 관한 연구 (Research for Stepping Motor Using Piezoelectric Torsional Actuator)

  • 김준혁;김재환;정달도
    • 한국소음진동공학회논문집
    • /
    • 제15권4호
    • /
    • pp.499-505
    • /
    • 2005
  • In this paper, a new type of pi+ezoelectric stepping motor is designed, manufactured and tested. This motor is composed of piezoelectric torsional actuator and a pair of one-way clutch bearings. The torsional actuator consists of 16-polygonal tube of piezoceramic that can produce an angular displacement associated with shear mode. One-way clutch bearing converts oscillation of torsional actuator into a continuous stepping rotation. The proposed stepping motor does not require any conversion mechanism for stepping motion like any other motors. In the design process, the shear resonance mode of piezoelectric actuator is analyzed by using a commercial finite element analysis program, and the performance of the fabricated torsional actuator is measured. $0.124^{\circ}$ of maximum angular displacement is measured in square wave excitation on the actuator only. The stepping motor is manufactured by assembling a pair of one-way clutch bearings and the torsional actuator. The maximum rotation speed of 72rpm and the blocking torque of 3.136 mNm are measured at 3540 Hz and 100V/mm. Once the proposed piezoelectric stepping motor is miniaturized, it can be used for many compact and precise moving applications.

External Electrode Fluorescent Lamp (EEFL)의 입력 주파수에 따른 휘도특성 (Brightness Property by Applied Frequency for External Electrode Fluorescent Lamp (EEFL))

  • 이성진;양종경;최용성;이상헌;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.223-225
    • /
    • 2005
  • An external electrode fluorescent lamps (EEFLs) have the advantage of a long lifetime in the early stages of the study on plasma discharge, interest in the lamp continues. Studies on the operation of external electrode fluorescent lamps have focused mainly on its use of a type of high frequency (MHz). By performing high brightness using a square wave operation method with the low frequency below 100kHz, which is applied to a narrowed tube type lamp that has several mm of lamp diameter, an EEFL presented the possibility of using it as a light source for backlights. However, because an EEFL generates plasma using wall charges, which considers the impedance characteristics of glass based on the structural principle in discharge, it can be significantly affected by frequency. Thus, this study verifies the change in the characteristics of electromagnetic fields according to the change in frequency through a Maxwell's electromagnetic field simulation and examines the relationship between the change in the EEFL frequency and brightness by measuring the optical characteristics. In addition, the characteristics of the transformation of energy orbits were verified by investigating the characteristics of the wavelength according to the change in frequency through the OES.

  • PDF

EEFL의 주파수 변화에 따른 전기적 특성과 휘도특성 (Luminance Properties and Electrical Properties by Applied Frequency of External Electrode Fluorescent Lamp(EEFL))

  • 이성진;이종찬;박노준;박대희
    • 전기학회논문지
    • /
    • 제56권2호
    • /
    • pp.355-360
    • /
    • 2007
  • The recent TFT-LCD Trend that is done large size gradually. As size of monitor great, though problem happens, it is that consumer's request which it makes monitor combined TV function. Monitor and TV are no difference externally greatly, but define difference happens as for backlight. An external electrode fluorescent lamp (EEFL) has an advantage of a long lifetime in the early stages of the study on plasma discharge, interest in the lamp continues. Researches on the operation of external electrode fluorescent lamps have focused mainly on its use of a type of high frequency (MHz). By performing high Luminance using a square wave operation method with the low frequency below 100kHz, which is applied to a narrowed tube type lamp that has several mm of lamp diameter, EEFL presented the possibility of using it as a light source for back-lights. However, because EEFL generates plasma using wall charges, which considers the impedance characteristics of glass based on the structural principle in discharge, it can be significantly affected by frequency. Thus, this study verified the change in the characteristics of electromagnetic fields according to the change in frequency through a Maxwell electromagnetic field simulation and examined the relationship between the change in the EEFL frequency and Luminance by measuring the optical characteristics.

초음파센서를 이용한 냉중성자원 수직공 형상측정 (Measurement of the Shape of the Cold Neutron Source Vertical Hole by Ultrasonic Wave Sensor)

  • 박국남;최창웅;심철무
    • 대한기계학회논문집A
    • /
    • 제24권9호
    • /
    • pp.2167-2173
    • /
    • 2000
  • The HANARO (High-flux Advanced Neutron Application Reactor) has operated since 1995. The Cold Neutron(CN) hole was implanted in the reflector tank from the design stage. Before a vacuum chamber and a moderator cell for the cold neutron source are installed into the CN hole, it is necessary to measure the exact size of the inside diameter and thickness of the CN hole to prevent the interference problem. Due to inaccessibility and high radiation field in the CN hole, a mechanical measurement method is not permitted. The immersion ultrasonic technique is considered as the best method to measure the thickness and the diameter. The 4 axis manipulator of the 2 channel of a sensor module was fabricated. The transducer of 10 MHz results in 0.03 nun of resolution. The inside diameter and thickness for 550 points of the CN hole were measured using 2 channel ultrasonic sensors. The results showed that the thickness is in the range of 13-6.7 mm and inside diameter is in the range of o 156-165. These data will be a good reference in the design of a cold neutron source facility.

두 평면 전극 사이의 절연체 구조물에 의해 유도되는 양의 유전영동을 이용한 삼차원 입자 정렬기 (A Three-Dimensional Particle Focusing Channel Using the Positive Dielectrophoresis (pDEP) Guided by a Dielectric Structure Between Two Planar Electrodes)

  • 추현정;도일;조영호
    • 대한기계학회논문집A
    • /
    • 제33권3호
    • /
    • pp.261-264
    • /
    • 2009
  • We present a three-dimensional (3D) particle focusing channel using the positive dielectrophoresis (pDEP) guided by a dielectric structure between two planar electrodes. The dielectric structure between two planar electrodes induces the maximum electric field at the center of the microchannel, and particles are focused to the center of the microchannel by pDEP as they flow from the single sample injection port. Compared to the previous 3D particle focusing methods, the present device achieves the simple and effective particle focusing function without any additional fluidic ports and top electrodes. In the experimental study, approximately 90 % focusing efficiency were achieved within the focusing length of 2mm, on both x-z plane (top-view) and y-z plane (side-view) for $2{\mu}m$-diameter polystyrene (PS) bead at the applied voltage over 15 Vp-p (square wave) and at the flow rate below 0.01 ${\mu}l$/min. The present 3D particle focusing channel results in a simple particle focusing method suitable for use in integrated microbiochemical analysis system.