• Title/Summary/Keyword: mmWave

Search Result 1,014, Processing Time 0.03 seconds

Design and Fabrication of Dual-Band Planar Monopole Antenna with Defected Ground Structure for WLAN Applications (WLAN 시스템에 적용 가능한 결함 접지 구조를 갖는 이중대역 평면형 모노폴 안테나 설계 및 제작)

  • Kang, Byeong-Nam;Rhee, Seung-Yeop;Jeong, Min-Joo;Choi, Domin;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.1
    • /
    • pp.42-49
    • /
    • 2018
  • In this paper, a dual-band microstrip-fed monopole antenna with a DGS(defected ground structure) for WLAN(wireless local area network) applications is presented. The antenna consists of a monopole and a defected ground, which were etched on both sides of the FR-4 substrate. The defected ground structure was used to obtain the dual band, while the step-by-step reduction in the monopole width was used to improve the impedance matching of the antenna. The antenna has an overall compact size of $44{\times}51{\times}1.6mm^3$, which was optimized by varying the size of the monopole and the ground plane such that it may resonate at the 2.4 GHz and 5 GHz bands of the WLAN. The measurement results showed that the antenna operates in the frequency band of 210 MHz(2.29~2.50 GHz) and 900 MHz(5.05~5.95 GHz) for a VSWR under 2, and showed omnidirectional radiation pattern at all desired frequencies.

Analysis of Runoff Impact by Land Use Change - Using Grid Based Kinematic Wave Storm Runoff Model (KIMSTORM) - (토지이용의 변화가 홍수유출에 미치는 영향분석)

  • Kim, Seong-Joon;Park, Geun-Ae;Chun, Moo-Kab
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.4 s.153
    • /
    • pp.301-311
    • /
    • 2005
  • The purpose of this study is to assess the quantitative effect of stream discharge due to land use changes. The upstream watershed of Pyeongtaek gauging station of Anseong-cheon ($592.6\;km^2$) was adopted. To accomplish the purpose, firstly, trace land use changes for the selected watershed which have some changes of land use by using Landsat images of 1986 and 1999 of the watershed and secondly, analyse the quantitative effect of stream discharge due to land use changes by applying GIS- based distributed hydrologic model KIMSTORM. The model was calibrated and verified at 2 locations (Pyeongtaek and Gongdo) by comparing observed with simulated discharge results for 7 storm events from 1998 to 2003. Model output was designed to provide information of land use impact on runoff components in the watershed and the sensitivity of impact level of each land use category on storm runoff. Land use impact was evaluated with the land use data sets for 1986 and 1999 for the same rainfall condition (160.5 mm). Area decrease of 4.8 percent of forest and 4.0 percent of paddy field during 13 years (1986 - 1999) within the watershed caused a 30.3 percent increase of peak runoff and a 9.3 percent increase of runoff volume.

Spatial Characteristics of Vegetation Development and Groundwater Level in Sand Dunes on a Natural Beach (해안사구의 지하수위와 식생 발달의 공간적 특성 연구)

  • Park, JungHyun;Yoon, Han-sam;Jeon, Yong-Ho
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.19 no.3
    • /
    • pp.218-226
    • /
    • 2016
  • Field observations were used to study the characteristics and influence of groundwater level fluctuations on vegetation development on the natural beach of a sandy barrier island, in the Nakdong River estuary. The spatial/temporal fluctuations of the groundwater level and the interactions with the external forces (weather, ocean wave and tide) were analyzed. The results indicated that when it rains the groundwater level rises. During summer, when precipitation intensity is greater than 20 mm/hour, it rose rapidly over 20 cm. Subsequently, it fell gradually during periods of no precipitation. Seasonal characteristics indicated that the groundwater level was high during the summer rainy season and tended to fall in the winter dry season. The time-averaged groundwater level, observed from the four observations over 3 years (2012-2014), was about 1.47 m, higher than mean sea level (M.S.L.). It was shown that the average annual groundwater level rises toward the land rather than showing intertidal patterns observation. Differences in the presence or absence of a coastal sand dunes affected the progress of vegetation. In other words, in environments of saltwater intrusion where the groundwater level varies, dependent on the distance from the shoreline and bottom slope, sand dunes can be provided to affect soil conditions and groundwater, so that vegetation can be grown reliably.

Magnetic Properties and the Crystallization of Amorphous Nd-Fe-Ti-B (Nd-Fe-Ti-B 비정질 합금의 자기적 성질 연구)

  • 이승화;안성용;김철성;김윤배;김창석
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.3
    • /
    • pp.140-145
    • /
    • 1997
  • The amorphous state of $NdFe_{10.7}TiB_{0.3}$ and its nanocrystallization have been studied by X-ray diffraction, 모스바우어 spectroscopy, and a vibrating sample magnetometer (VSM), $NdFe_{10.7}TiB_{0.3}$ amorphous ribbons were fabricated by a sigle-roll melt-spinning method. The average hyperfine field $H_{hf}$(T) of the amorphous state shows a temperature dependence of $[H_{hf}(T)-H_{hf}(0)]/H_{hf}(0)=-0.46(T/T_c)^{3/2}-0.34(T/T_c)^{5/2}$ for $T/T_c<0.7$ indicative of spin wave excitation. The quadrupole splitting just above the Curie temperature $T_c$ is 0.46 mm/s, whereas the average quadrupole shift below $T_c$ is zero. The Curie and crystallization temperatures are determined to be $T_c$=380K and $T_x=490K$, respectively, for a heating rate of 5 K/min. The occupied area of nanocrystalline phase at around 770K is about 65%. Above the Curie temperature, VSM data show magnetic moments increases again. The formation of $\alpha$-Fe is the main reason for the increasing moment as conformed with the 모스바우어 measurements.

  • PDF

Broadband LTCC Receiver Module for Fixed Communication in 40 GHz Band (40 GHz 대역 고정통신용 광대역 LTCC 수신기 모듈)

  • Kim Bong-Su;Kim Kwang-Seon;Eun Ki-Chan;Byun Woo-Jin;Song Myung-Sun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.10 s.101
    • /
    • pp.1050-1058
    • /
    • 2005
  • This paper presents how to design and implement a very compact, cost effective and broad band receiver module for IEEE 802.16 FWA(Fixed Wireless Access) in the 40 GHz band. The presented receiver module is fabricated in a multi-layer LTCC(Low Temperature Cofired Ceramic) technology with cavity process to achieve excellent electrical performances. The receiver consists of two MMICs, low noise amplifier and sub-harmonic mixer, an embedded image rejection filter and an IF amplifier. CB-CPW, stripline, several bond wires and various transitions to connect each element are optimally designed to keep transmission loss low and module compact in size. The LTCC is composed of 6 layers of Dupont DP-943 with relative permittivity of 7.1. The thickness of each layer is 100 um. The implemented module is $20{\times}7.5{\times}1.5\;mm^3$ in size and shows an overall noise figure of 4.8 dB, an overall down conversion gain of 19.83 dB, input P1 dB of -22.8 dBm and image rejection value of 36.6 dBc. Furthermore, experimental results demonstrate that the receiver module is suitable for detection of Digital TV signal transmitted after up-conversion of $560\~590\;MHz$ band to 40 GHz.

A Study of the RCS Reduction by Pattern Synthesis for Singly Curved Structures (패턴 합성을 통한 단일 곡면 구조에서의 RCS 감소 기술에 관한 연구)

  • Kim, Woojoong;Seo, Hyeong Pil;Kim, Youngsub;Yoon, Young Joong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.4
    • /
    • pp.366-373
    • /
    • 2013
  • This paper discusses the singly curved phased reflector for reduced RCS pattern, which has minimized RCS level at boresight with a null by phase cancelation and the lowered RCS level of main beam by splitting the main beam into multi directions. Considering the reduced level of boresight and main beam compared to the same sized reference PEC, this proposed multi-beam reflector can be adopted in the mono-static radar and the bi-static radar environment. The proposed reflector is a multi-beam reflector, which has different phase distributions at each row for different steering angle. It is designed through an intermediate stage of a single and dual-beam reflector. The behaviors of the designed reflectors are verified through full-wave simulation and experiment. The reflectors are designed in the frequency of 10 GHz and it has a size $240{\times}180mm^2$($8{\times}6\;{\lambda}^2$) with the curvature k=3.3. From the measured results, the proposed reflectors reduce the reflected power by 17 dB at boresight.

Soft Plasma Flash X-ray Generator Utilizing a Vacuum Discharge Capillary

  • Sato, Eiichi;Hayasi, Yasuomi;Usuki, Tatsumi;Sato, Koetsu;Takayama, Kazuyoshi;Ido, Hideaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.400-403
    • /
    • 2002
  • The fundamental experiments for measuring soft x-ray characteristics from the vacuum capillary are described. These experiments were primarily performed in order to generate line spectra such as x-ray lasers. The generator consists of a high-voltage power supply, a polarity-inversion ignitron pulse generator, a turbo-molecular pump, and a radiation tube with a capillary. A high-voltage condenser of 200 nF in the pulse generator is charged up to 20 kV by the power supply, and the electric charges in the condenser are discharged to the capillary in the tube after closing the ignitron. During the discharge, weakly ionized plasma forms on the inner and outer sides of a capillary. In the present work, the pump evacuates air from the tube with a pressure of about 1 mPa, and a demountable capillary was developed in order to measure x-ray spectra according to changes in the capillary length. In this capillary, the anode (target) and cathode elements can be changed corresponding to the objectives. The capillary diameter is 2.0 mm, and the length is adjusted from 1 to 50 mm. When a capillary with aluminum anode and cathode electrodes was employed, both the cathode voltage and the discharge current almost displayed damped oscillations. The peak values of the voltage and current increased when the charging voltage was increased, and their maximum values were -10.8 kV and 4.7 kA, respectively. The x-ray durations observed by a 1.6 ${\mu}$m aluminum filter were less than 30 ${\mu}$s, and we detected the aluminum characteristic x-ray intensity using a 6.8 ${\mu}$m aluminum filter. In the spectrum measurement, two sets of aluminum and titanium electrodes were employed, and we observed multi-line spectra. The line photon energies seldom varied according to changes in the condenser charging voltage and to changes in the electrode element. In the case where the titanium electrode was employed, the line number decreased with corresponding decreases in the capillary length. Compared with incoherent visible light, these rays from the capillary were diffracted and diffused greatly after passing through two slits.

  • PDF

Transient Change of Electrocardiogram in Two Young Women With Salicylate Intoxication - Two Cases Report - (아스피린 중독에 의한 심전도 변화 2례)

  • You Je-Sung;Park Jong-Woo;Choi Young-Hwan;Cho Young-Soon;Cho Kwang-Hyun;Park Jun-Seok;Chung Sung-Pil;Lee Hahn-Shick
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.4 no.1
    • /
    • pp.44-47
    • /
    • 2006
  • Symptoms of aspirin overdose may vary from acid-base disturbance, electrolyte abnormality, non-cardiogenic pulmonary edema, chemical hepatitis, seizure to cardiac toxicity. Cardiac adverse effects from aspirin are uncommon but there are reports of arrhythmia, cardiopulmonary arrest, and myocardial infarction. We report 2 cases of young women with aspirin overdose who exhibited ischemic changes on their ECGs a few hours after the ingestion with spontaneous recovery in a few days. First case, a 29 year old woman, presented to the emergency department 6 hours after ingesting 250 tablets of aspirin (325 mg/T). On examination, the temperature was $36.3^{\circ}C$: blood pressure, 105/72mmHg; Pulse, 111/min and respiratory rate, 24/min. Second case, a 27 year old woman, an hour after ingesting 60 tablets (325mg/T). On examination, the temperature was $36.0^{\circ}C$: blood pressure, 102/72 mmHg; pulse, 89/min and respiratory rate, 25/min. In both cases, ECG after 6 hours of ingestion had sinus tachycardia and developed T wave inversion on the anterior leads in the following ECGs. Their initial serum salicylate levels after 6 hours of ingestion were 71.2 mg/dL and 28.4 mg/dL respectively. These salicylate levels were resolving when these ECGs were observed. The ECG changes resolved in the following days and they were discharged without any further symptoms. Further studies are needed, but for the time being, when dealing with salicylate overdose, transient cardiac depression should be kept in mind to avoid adverse ischemic cardiac events.

  • PDF

Development of Life Test Equipment with Real Time Monitoring System for Butterfly Valves

  • Lee, Gi-Chun;Choi, Byung-Oh;Lee, Young-Bum;Park, Jong-Won;Nam, Tae-Yeon;Song, Keun-Won
    • International Journal of Fluid Machinery and Systems
    • /
    • v.10 no.1
    • /
    • pp.40-46
    • /
    • 2017
  • Small valves including ball valves, gate valves and butterfly valves have been adopted in the fields of steam power generation, petrochemical industry, carriers, and oil tankers. Butterfly valves have normally been applied to fields where in narrow places installing the existing valves such as gate valves and ball valves have proven difficult due to the surrounding area and the heavier of these valves. Butterfly valves are used to control the mass flow of the piping system under low pressure by rotating the circular disk installed inside. The butterfly valve is benefitted by having simpler structure in which the flow is controlled by rotating the disc circular plate along the center axis, whereas the weight of the valve is light compared to the gate valve and ball valve above-mentioned, as there is no additional bracket supporting the valve body. The manufacturing company needs to acquire the performance and life test equipment, in the case of adopting the improving factors to detect leakage and damage on the seat of the valve disc. However, small companies, which are manufacturing the industrial valves, normally sell their products without the life test, which is the reliability test and environment test, because of financial and manpower problems. Furthermore, the failure mode analysis of the products failed in the field is likewise problematic as there is no system collecting the failure data on sites for analyzing the failures of valves. The analyzing and researching process is not arranged systematically because of the financial problem. Therefore this study firstly tried to obtain information about the failure data from the sites, analyzed the failure mode based on the field data collected from the customers, and then obtained field data using measuring equipment. Secondly, we designed and manufactured the performance and life test equipment which also have the real time monitoring system with the naked eye for the butterfly valves. The concept of this equipment can also be adopted by other valves, such as the ball valve, gate valve, and various others. It can be applied to variously sized valves, ranging from 25 mm to large sized valves exceeding 3000 mm. Finally, this study carries out the life test with square wave pressure, using performance and life test equipment. The performance found out that the failures from the real time monitoring system were good. The results of this study can be expanded to the other valves like ball valves, gate valves, and control valves to find out the failure mode using the real time monitoring system for durability and performance tests.

Research on the Multi-electrode Plasma Discharge for the Large Area PECVD Processing

  • Lee, Yun-Seong;You, Dae-Ho;Seol, You-Bin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.478-478
    • /
    • 2012
  • Recently, there are many researches in order to increase the deposition rate (D/R) and improve film uniformity and quality in the deposition of microcrystalline silicon thin film. These two factors are the most important issues in the fabrication of the thin film solar cell, and for the purpose of that, several process conditions, including the large area electrode (more than 1.1 X 1.3 (m2)), higher pressure (1 ~ 10 (Torr)), and very high frequency regime (VHF, 40 ~ 100 (MHz)), have been needed. But, in the case of large-area capacitively coupled discharges (CCP) driven at frequencies higher than the usual RF (13.56 (MHz)) frequency, the standing wave and skin effects should be the critical problems for obtaining the good plasma uniformity, and the ion damage on the thin film layer due to the high voltage between the substrate and the bulk plasma might cause the defects which degrade the film quality. In this study, we will propose the new concept of the large-area multi-electrode (a new multi-electrode concept for the large-area plasma source), which consists of a series of electrodes and grounds arranged by turns. The experimental results with this new electrode showed the processing performances of high D/R (1 ~ 2 (nm/sec)), controllable crystallinity (~70% and controllable), and good uniformity (less than 10%) at the conditions of the relatively high frequency of 40 MHz in the large-area electrode of 280 X 540 mm2. And, we also observed the SEM images of the deposited thin film at the conditions of peeling, normal microcrystalline, and powder formation, and discussed the mechanisms of the crystal formation and voids generation in the film in order to try the enhancement of the film quality compared to the cases of normal VHF capacitive discharges. Also, we will discuss the relation between the processing parameters (including gap length between electrode and substrate, operating pressure) and the processing results (D/R and crystallinity) with the process condition map for ${\mu}c$-Si:H formation at a fixed input power and gas flow rate. Finally, we will discuss the potential of the multi-electrode of the 3.5G-class large-area plasma processing (650 X 550 (mm2) to the possibility of the expansion of the new electrode concept to 8G class large-area plasma processing and the additional issues in order to improve the process efficiency.

  • PDF