• Title/Summary/Keyword: mmWave

Search Result 1,015, Processing Time 0.028 seconds

Design of a Ka-Band Orthomode Transducer (Ka-대역 직교모드변환기 설계)

  • 이종경;채범용;박동희;안병철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.1
    • /
    • pp.110-118
    • /
    • 2004
  • In this paper, a method is presented for the design of an orthomode transducer(OMT) operating at 21/31GHz frequency bands. A square waveguide is used in the common port while the WR-34 standard rectangular waveguide is used in the straight port. The straight port is connected to the common port via a multi-stage quarter-wave impedance transformer. The side port is coupled to the common port through a slot formed along the center line of the common square waveguide. An impedance transformer is employed to match the impedance of the coupling slot with that of the WR-51 waveguide at the output of the side port. Dimensions of the OMT are iteratively optimized employing the theory of waveguide. The validity of the proposed method is verified by fabricating and testing the designed orthomode transducer.

Design of a Tapered Slot Array Antenna with Uniplanar Feed (유니플래너 급전구조를 갖는 테이퍼드 슬롯 안테나의 설계)

  • Kim, Hye-Ri;Park, Noh-Joon;Kang, Young-Jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.2
    • /
    • pp.386-391
    • /
    • 2006
  • In this paper, a design of V-type Linearly Tapered Slot Antenna(V-LTSA) with uniplanar microstrip-to-coplanar stripline(CPS) transitions is presented. The effect of reducing and increasing with taper width G, teper length L and opening angle are also considered at 5.8 GHz. In the result of a simulation by using CST-MWS, the return loss characteristic came very wide band about 4.3GHz, or 1.8 Octave. Proposed V-LTSA design schemes are expected to be a good antenna for microwave and millimeter-wave communcations.

Electric aging phenomena of $0.2(PbMg_{1/3}Nb_{2/3}O_3)-0.8(PbZr_{0.475}Ti_{0.525}O_3)$ Multilayer Ceramic Actuators ($0.2(PbMg_{1/3}Nb_{2/3}O_3)-0.8(PbZr_{0.475}Ti_{0.525}O_3)$ 적층형 세라믹 액츄에이터의 전기적 열화 특성)

  • Koh, Jung-Hyuk;Jeong, Soon-Jong;Ha, Moon-Su;Lee, Dong-Man;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.219-222
    • /
    • 2003
  • $0.2(PbMg_{1/3}Nb_{2/3}O_3)-0.8(PbZr_{0.475}Ti_{0.525}O_3)$ 조성을 이용하여 $5{\times}5{\times}5mm^3$의 적층형 세라믹 액츄에이터 소자를 tape casting 방법으로 제작하였다. 전극재로서는 Ag-Pd를 이용하여 총 50층의 layer를 적층하였으며, 적층된 액츄에이터를 $1100^{\circ}C$의 온도에서 소결하였다. X-ray diffractometer를 이용하여 제작된 소자와 열화된 소자의 구조적인 특성을 분석하였다. 제작된 소자의 열화 특성을 알아보기 위하여 60 Hz 의 triangular wave를 인가하여 열화전과 후의 p-E hystcresis loop의 변화를 살펴보았으며, 인가된 전압의 변화에 따라서 소자에서 발생되는 양의 열을 측정하였다. 파괴된 소자의 파단면에 대한 SEM 분석을 통하여 소자의 파괴 메카니즘을 알아보도록 하였다. 이로부터 전기적 기계적 열화가 소자의 동작에 미치는 영향에 대해서 알아 보았다.

  • PDF

Brightness Characteristics by Applied Frequency for External Electrode Fluorescent Lamp (외부전극형 형광램프의 입력 주파수에 따른 휘도 특성)

  • Choi, Yong-Sung;Cha, Jae-Chea;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.12a
    • /
    • pp.75-78
    • /
    • 2006
  • An external electrode fluorescent lamps (EEFLs) have the advantage of a long lifetime in the early stages of the study on plasma discharge, interest in the lamp continues. Studies on the operation of external electrode fluorescent lamps have focused mainlyon its use of a type of high frequency (MHz). By performing high brightness using a square wave operation method with the low frequency below 100kHz, which is applied to a narrowed tube type lamp that has several mm of lamp diameter, an EEFL presented the possibility of using it as a light source for backlights. However, because an EEFL generates plasma using wall charges, which considers the impedance characteristics of glass based on the structural principle in discharge, it can be significantly affected by frequency. Thus, this study verifies the change in the characteristics of electromagnetic fields according to the change in frequency through a Maxwell's electromagnetic field simulation and examines the relationship between the change in the EEFL frequency and brightness by measuring the optical. characteristics. In addition, the characteristics of the transformation of energy orbits were verified by investigating the characteristics of the wavelength according to the change in frequency through the OES.

  • PDF

Stimulatory Effect of Ga-As Infrared Laser on the Regeneration of Injured Sciatic Nerves (손상된 좌골신경의 재생에 미치는 Ga-As 적외선 레이저의 효과)

  • 배춘식;임성철;박석천
    • Journal of Veterinary Clinics
    • /
    • v.19 no.3
    • /
    • pp.316-321
    • /
    • 2002
  • The purpose of this study was to examine the effect of Ga-As(Gallium-Arsenide, wave length; 904 nm) infrared laser irradiation on healing of the experimentally crush injured rat sciatic nerves. The bilateral sciatic nerves of 43 adult male Sprague-Dawley rats were compressed surgically with a straight hemostat (1 mm width). The right legs of all the rats were irradiated using a 27 mW Ga-As infrared laser (laser irradiated group). The radiation procedure was administered for 3 minutes every day for 1, 3, 5, and 7 weeks in each group. Left legs were not irradiated and served as the control group. The numbers of total myelinated axon and degenerated myelin in the sciatic nerves of bilateral legs were measured and analyzed with mage analysis system in order to make a morphological analysis of the effect of the Ga-As infrared laser on injured nerves. Total number of myelinated axons was increased with time interval, especially in the 1, 3. and 5 week of irradiated group. Conversely, the number of degenerated myelin was decreased with time interval, especially in the irradiated group. The effects in the irradiated group were more pronounced than those of the control group. In conclusion, the Ga-As infrared laser irradiation is a useful adjuvant therapy to the regeneration of the peripheral nerve injury.

An experimental study of the overall characteristics in an aero-valved pulsating combustor (空氣밸브型 脈動燃燒器의 特性에 관한 實驗的 硏究)

  • 오상헌;최병륜;임광열
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.2
    • /
    • pp.271-278
    • /
    • 1987
  • The experimental study was carried out to investigate the pressure fluctuation, operating frequency, noise emission and combustion characteristics in an aero-valved pulsating combustor. Measurements of the pressure fluctuation, mean temperature and ion current inside the combustion chamber indicate that combustion phenomena are characteristically similar to those in the diffusion flame. The measured frequency schedue indicates that the acoustic theory of the quarter wave tube can be approximated to give the operating frequency, but correction factor must be involved to estimate the correct operating frequency. The spectral behavior of the noise emission exhibits that frequency bands with high noise intensity are narrowly restricted to the neighborhood of the operating frequency signalling the low-frequency combustion characteristics of the pulsating combustor. Measurements of the operating characteristics as variation of the fuel nozzle diameter and injection angle with 4 fuel nozzles have been made, and it was found that the system produced the stable operating conditions up to the turn down ratio of 3 when the fuel nozzle diameter is 1.2mm, and the optimum fuel injection angle is thought to be in the neighborhood of 30.deg. radially.

Electrochemical Behavior of the Reduction of Thin Films of $Ag_3Fe(CN)_6$

  • Moon Seongbae;Moon Jung Dae
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.12
    • /
    • pp.1042-1045
    • /
    • 1994
  • A thin film of silver ferricyanide (Ag$_3$Fe(CN)$_6$) on a platinum or gold substrates can be reduced electrochemically to the salt of silver ferrocyanide in potassium nitrate solution. The color of these films are orange and these films are shown to be electrochromic. The voltammogram is shown the asymmetry of the oxidation compared to the reduction wave under various supporting electrolytes. The standard heterogeneous electron-transfer rate for these films and bare Pt electrode were 0.49 ${\times}$ l0$^{-2}$ and 1.30 ${\times}$ l0$^{-2}$ cm/s, respectively, obtained using a rotating disc electrode. Rough D$_0$ values, evaluated from the Levich equation, for Fe(CN)$_6^{3-/4-}$ at both SF thin film and a bare Pt disc electrode were shown as 1.2l ${\times}$ l0-6 and 0.94 ${\times}$ l0$^{-6}$ cm$^2$/s, respectively. The conductivities, as determined from the slops of the i-V curves for a ca. 1 mm sample for dried SF potassium rich and deficient bulk samples pressed between graphite electrodes, were 9.34 ${\times}$ l0$^{-9}$ and 5.80 ${\times}$ l0$^{-9}$ (${\Omega}$${\cdot}$cm)$^{-1}$, respectively.

2×2 Ti:LiNbO3 optical add/drop multiplexers utilizing tilted film-loaded SAW waveguides (Tilted Film-Leaded SAW 도파로를 이용한 2×2 Ti:LiNbO3 광 삽입/분기 멀티플렉서)

  • 강창민;정흥식
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.6
    • /
    • pp.657-662
    • /
    • 2003
  • Optimum Hamming apodized acousto-optic 2${\times}$2 add/drop multiplexers, using SiO$_2$ film loaded acoustic waveguide with angular offset to the Ti:LiNbO$_3$ waveguide, were fabricated. The four-port device consists of two input waveguides, a polarization beam splitter (PBS), two polarization conversion/acoustooptic tuning waveguide sections, a second PBS and two output waveguides. Insertion loss <7.1 ㏈ has been obtained and side-lobe of -19 ㏈ for -32 ㎽ RF driving power has been realized. Add/drop performance has been confirmed and a linear tuning rate of 8.1 nm/MHz and a 3 ㏈ spectral width of -1.5 nm were demonstrated.

Experimental study on liquid sloshing with dual vertical porous baffles in a sway excited tank

  • Sahaj, K.V.;Nasar, T.;Vijay, K.G.
    • Ocean Systems Engineering
    • /
    • v.11 no.4
    • /
    • pp.353-371
    • /
    • 2021
  • Sloshing behavior of liquid within containers represents one of the most fundamental fluid-structure interactions. Liquid in partially filled tanks tends to slosh when subjected to external disturbances. Sloshing is a vicious resonant fluid motion in a moving tank. To understand the effect of baffle positioned at L/3 and 2L/3 location, a shake table experiments was conducted for different fill volumes of aspect ratio 0.163, 0.325 and 0.488. For a fixed amplitude of 7.5 mm, the excitation frequencies are varied between 0.457 Hz to 1.976 Hz. Wave probes have been located at both tank ends to capture the surface elevation. The experimental parameters such as sloshing oscillation and energy dissipation are discussed here. Comparison is done for with baffles and without baffles conditions. For both conditions, the results showed that aspect ratio of 0.163 gives better surface elevation and energy dissipation than obtained for aspect ratio 0.325 and 0.488. Good agreement is observed when numerical analysis is compared with the experiments results.

RENOVATION OF SEOUL RADIO ASTRONOMY OBSERVATORY AND ITS FIRST MILLIMETER VLBI OBSERVATIONS

  • Naeun, Shin;Yong-Sun, Park;Do-Young, Byun;Jinguk, Seo;Dongkok, Kim;Cheulhong, Min;Hyunwoo, Kang;Keiichi, Asada;Wen-Ping, Lo;Sascha, Trippe
    • Journal of The Korean Astronomical Society
    • /
    • v.55 no.6
    • /
    • pp.207-213
    • /
    • 2022
  • The Seoul Radio Astronomy Observatory (SRAO) operates a 6.1-meter radio telescope on the Gwanak campus of Seoul National University. We present the efforts to reform SRAO to a Very Long Baseline Interferometry (VLBI) station, motivated by recent achievements by millimeter interferometer networks such as Event Horizon Telescope, East Asia VLBI Network, and Korean VLBI Network (KVN). For this goal, we installed a receiver that had been used in the Combined Array for Research in Millimeter-wave Astronomy and a digital backend, including an H-maser clock. The existing hardware and software were also revised, which had been dedicated only to single-dish operations. After several years of preparations and test observations in 1 and 3-millimeter bands, a fringe was successfully detected toward 3C 84 in 86 GHz in June 2022 for a baseline between SRAO and KVN Ulsan station separated by 300 km. Thanks to the dual frequency operation of the receiver, the VLBI observations will soon be extended to the 1 mm band and verify the frequency phase referencing technique between 1 and 3-millimeter bands.