• 제목/요약/키워드: mixed-use building

검색결과 230건 처리시간 0.031초

섬유 혼합토의 공학적 특성 (Engineering Properties of Fiber Mixed Soil)

  • 장병욱;박영곤
    • 한국농공학회지
    • /
    • 제44권1호
    • /
    • pp.116-124
    • /
    • 2002
  • Natural resources fur the construction materials such as good soil, sand, and coarse aggregates have been encountered to be short due to excessive use by human. Even though some soil has been found to be unsuitable for construction materials, soil with reinforcement can naturally be an answer to these alternatives. According to recently published papers on fiber mixed soil, fiber mixed with soil can improve shear strength, compressive strength and post-peak load strength retention. In this study, a series of tests were performed to clarify the characteristics of fiber mixed soil and to give basic data for design and construction and their engineering properties, that is, unconfined compressive strength, splitting tensile strength, shear strength, crack by drying, freeze-thaw, creep and Poisson\`s ratio, were investigated and analyzed. It has been shown that fiber mixed soil is one of good alternatives fur the civil and building construction materials.

Structural Design of Mid-Story SI Tall-building with RC Frame Placed on Steel Structure

  • Isobe, Tomonobu;Aono, Hideshi
    • 국제초고층학회논문집
    • /
    • 제10권3호
    • /
    • pp.173-178
    • /
    • 2021
  • In this paper we introduce Shinagawa HEART, located in Shinagawa district, Tokyo. It is a mixed-use building with residences on the upper floors, offices on the lower floors, and commercial uses on the first and second floors, and is intended to meet the various needs of a building on the border between residential and commercial areas. The upper floors of the building are made of reinforced concrete, while the middle and lower floors are made of steel with CFT columns. First, an overview of the structural plan of the building is presented. Next, the adoption of the middle layer seismic isolation and the switch between the lower steel structure and the upper reinforced concrete structure, which are the features of this building, are explained. Finally, the construction method adopted to achieve the design performance is explained.

Preferences for High-rise Mixed Use Buildings (HMUBs) for Living Space in Later Life Among Urban Residents

  • Hong, Hyung-Ock
    • International Journal of Human Ecology
    • /
    • 제7권2호
    • /
    • pp.17-27
    • /
    • 2006
  • The purpose of this research was to find out the preferences in HMUBs for living space in respondents' later life. For this purpose, this research was conducted by social survey research using a questionnaire for those who lived in an urban area around Seoul. The data was collected from November to December, 2005. The results of this research were as follows. Firstly, respondents agreed with living in high rise mixed use buildings in their later life because of convenience. Willingness to move into HMUBs was positive. Concerning preferred physical features, residents preferred living in either lower floors or higher floors because of safety or fine views. Regarding the usage of common space and facilities, they wanted to use them with other generations and preferred 2 bedroom type unit located in a suburban area. Secondly, the preference for living in a HMUB in later life was higher in women respondents than in men. Thirdly, the preference for living in a HMUB in later life was higher in upper floors than lower floors according to property and asset value. As a conclusion, the development of HMUB housing for older people has a bright prospect for urban residents in Korea.

고로슬래그가 혼입된 갯벌 모르타르의 역학적 특성 (The Mechanical properties of Mud Flat mortar mixed with Blast furnace slag)

  • 강윤영;김희두;강대규;양성환
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.32-33
    • /
    • 2015
  • Depending on the industrialization, construction market has grown buildings are based on concrete will continue to increase. But the problems of environmental pollution come to the fore with the indiscriminate use of concrete and rapid development. In addition, carbon dioxide(CO2) in the process of producing cement being emitted a large amount of has been caused a serious problem of environmental pollution. This trend is being actively conducted research to reduce the use of cement. In this study, eco-friendly materials, such as flats, Blast-furnace slag by mix and cement review the mechanical characteristics of the mudflats eco-friendly cement mortar to reduce the usability of the review were seen as a green building material.

  • PDF

Toward Net-Zero Energy Retrofitting: Building-Integrated Photovoltaic Curtainwalls

  • Kim, Kyoung Hee;Im, Ok-Kyun
    • 국제초고층학회논문집
    • /
    • 제10권1호
    • /
    • pp.35-43
    • /
    • 2021
  • With the rapid urbanization and growing energy use intensity in the built environment, the glazed curtainwall has become ever more important in the architectural practice and environmental stewardship. Besides its energy efficiency roles, window has been an important transparent component for daylight penetration and a view-out for occupant satisfaction. In response to the climate crisis caused by the built environment, this research focuses on the study of net-zero energy retrofitting by using a new building integrated photovoltaic (BIPV) curtainwall as a sustainable alternative to conventional window systems. Design variables such as building orientations, climate zones, energy attributes of BIPV curtainwalls, and glazed area were studied, to minimize energy consumption and discomfort hours for three cities representing hot (Miami, FL), mixed (Charlotte, NC), and cold (Minneapolis, MN). Parametric analysis and Pareto solutions are presented to provide a comprehensive explanation of the correlation between design variables and performance objectives for net-zero energy retrofitting applications.

고막 패각을 잔골재로 사용한 철근콘크리트 보의 전단 거동에 관한 연구 (A Study on the Shear Behavior of Reinforced Concrete Beams Using of Cockle Shells as Fine Aggregate)

  • 김정섭;신용석
    • 한국건축시공학회지
    • /
    • 제4권2호
    • /
    • pp.89-95
    • /
    • 2004
  • 1) As result of specimen with shear reinforcing bar of reinforced concrete beam, ductile coefficient of specimen was high in specimen containing Cockle shells based on non-mixed specimen. In increase rate of specimens, yield strength was similar in specimens containing Cockle shells and non-mixed specimens and maximum strength was higher in specimen containing Cockle shells. 2) To sum up the above experimental results, it is found that using splitted Cockle shells as aggregate for concrete by 10%~ 15% showed the same or higher compressive strength and shear strength as concretes using general aggregate and it can be used as substitute aggregate of concrete. It is considered that for future use of splitted Cockle shells as substitute concrete aggregate, continuous researches of its durability, applicability and economy are needed.

CGS를 잔골재로 혼합 사용하는 모르타르의 공학적 특성 (Properties of Cement Mortar Using CGS as Mixed Fine Aggregate)

  • 한준희;이영준;현승용;박경택;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.138-139
    • /
    • 2018
  • This study is a basic review of the basic characteristics of mortar as a result of the use of concrete as a fine aggregate for CGS(coal gasification slag) generated from the IGCC(integrated gasification combined cycle). The analysis shows that CGS and crushed sand + seal sand mix is the best combination of CGS combined with about 75 % of CGS based on the effects of promoting liquidity and strength. This is expected to be a positive factor in securing the strength and flexibility of concrete given the optimal mix of CGS, and may also contribute to the improvement of quality.

  • PDF

급결마이크로시멘트 및 글리시딜아크릴레이트를 복합 적용한 누수현장 보수사례 (Rapid microcement and glycidylacrylate a Case Study on the Improvement of Water Leakage Site Applied to Mixed-use)

  • 조일규;유재형;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.241-242
    • /
    • 2019
  • This technology is a water leak repair technology using composite materials of concrete structures that block leakage of structures by injecting rapid microcement into the face of underground concrete to block water and injecting flexible glycidylacrylate. Rapid micro cement system repair materials are mixed with fine fibers to improve the flexural sensitivity of the material and to form a layer that blocks stabilized water at the back of the structure by allowing rapid and tight spatial filling during injection with high cohesion The glycidylacrylate repair material can control the expansion rate, and the external stress also has the characteristic that the form of the material is not destroyed or separated, which can also be applied to vibrating induced structures that produce repetitive fatigue loads, and has an effective durability in saline, alkali, acid (chloric acid, sulfuric acid, nitric acid).

  • PDF

택지개발지구내 단독주택지의 물리적 환경특성에 관한 연구 (A Study on the Physical Environment Characteristics of the Detached Housing Area in the Housing Site Development District)

  • 박몽섭;하재명
    • 한국주거학회논문집
    • /
    • 제15권3호
    • /
    • pp.43-51
    • /
    • 2004
  • The purpose of this study is to examine the physical characteristics of the detached housing area in the housing site development district. The process of this study is to investigate the characteristics of the physical structure and the building use, then to analyze the relationship of physical structure and the building use in the aspect of the morphological characteristics. The case study focuses on the Chil-kok2, An-Siml in Taegu. The streets pattern is composited gird and loop type mixed. The block is composited by 2 lots in general. But the obscurity of organization and character of the streets, the size and shape of lots which is not fit to the building use. A whole residential characters appears high residential density ratio. so residential environment became worse. The improving level of residential environment and efficiency of land use in the detached housing area of the housing site development district, firstly the propriety of the physical structure must be considered about detached house characters, and the housing uses which fit to the physical structure are needed, and also for the concrete realization of this, the designation of district, the zoning of residential area, the guideline of the district design, and establishment of comprehensive master planning in detached housing area are needed in aspect of the housing policy. As the result of this study, it suggests several design guideline to improve housing site development.

The ASHRAE Design Guide for Tall, Supertall and Megatall Building Systems

  • Simmonds, Peter
    • 국제초고층학회논문집
    • /
    • 제4권4호
    • /
    • pp.311-318
    • /
    • 2015
  • The ASHRAE Design Guide for Tall, Supertall and Megatall Building Systems was produced in collaboration with the CTBUH. The design guide outlines various tall building mechanical systems that are presently being designed or are planned for the future. Tall commercial buildings in particular present a series of design problems that set them apart from other functions. The Design Guide will be of interest to owners, architects, structural engineers, mechanical engineers, electrical engineers and other specialized engineers and consultants. This design guide addresses design issues for tall commercial buildings, which are very often mixed-use, and commonly consist of low level retail, office floors, residential units, and hotel uses.