• Title/Summary/Keyword: mixed resin

Search Result 411, Processing Time 0.037 seconds

Study on the Thermomechanical Properties of Epoxy-Silica Nanocomposites by FTIR Molecular Structure Analyses (FTIR 분자구조 해석을 통한 에폭시-실리카 나노복합소재의 열기계적 물성 연구)

  • Jang, SeoHyun;Han, Yusu;Hwang, DoSoon;Jung, Juwon;Kim, YeongKook
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.2
    • /
    • pp.51-57
    • /
    • 2021
  • This paper analyzed the effects of the concentration of nano-silica particles contained in epoxy resin on the thermomechanical properties of the composite materials. The 12nm sized nanoparticles were mixed with epoxy polymer by 5 different weight ratios for the test samples. The glass transition temperature, stress relaxation, and thermal expansion behaviors were measured using dymanic mechanical analyzer (DMA) and thermomechanical analyzer (TMA). It was shown that the nano particle mixing ratios had significant influences on the viscoelastic behaviors of the materials. As the content of the silica particles was increased, the elastic modulus was also increased, while the glass transition temperatures were decreased. Fourier Transform Infrared Spectroscopy (FTIR) results played an important role in determining the causes of the property changes by the filler contents in terms of the molecular structures, enabling the interpretations on the material behaviors based on the chemical structure changes.

How adjustment could affect internal and marginal adaptation of CAD/CAM crowns made with different materials

  • Hasanzade, Mahya;Moharrami, Mohammad;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.6
    • /
    • pp.344-350
    • /
    • 2020
  • PURPOSE. Recently introduced hybrid and reinforced glass ceramic computer-aided design/computer-aided manufacturing (CAD/CAM) materials have been used for full-coverage restorations. However; the effect of adjustment and type of materials on internal and marginal adaptation are unknown. This study aimed to evaluate and compare the marginal and internal adaptations of crowns made of three different CAD/CAM materials before and after adjustment. MATERIALS AND METHODS. One acrylic resin maxillary first molar was prepared and served as the master die. Thirty-six restorations were fabricated using CAD/CAM system (CEREC Omnicam, MCXL) with three materials including lithium disilicate (IPS e.max CAD), zirconia-reinforced lithium silicate (Suprinity), and hybrid ceramic (Enamic). Internal and marginal adaptations were evaluated with the reference point matching technique before and after adjustment. The data were analyzed using mixed ANOVA considering α=.05 as the significance level. RESULTS. The effect of adjustment and its interaction with the restoration material were significant for marginal, absolute marginal, and occlusal discrepancies (P<.05). Before adjustment, Suprinity had lower marginal discrepancies than IPS e.max CAD (P=.18) and Enamic (P=.021); though no significant differences existed after adjustment. CONCLUSION. Within the limitations of this study, crowns fabricated from IPS e.max CAD and Suprinity resulted in slightly better adaptation compared with Enamic crowns before adjustment. However, marginal, axial, and occlusal discrepancies were similar among all materials after the adjustment.

Biocompatibility and Bioactivity of Four Different Root Canal Sealers in Osteoblastic Cell Line MC3T3-El

  • Jun, Nu-Ri;Lee, Sun-Kyung;Lee, Sang-Im
    • Journal of dental hygiene science
    • /
    • v.21 no.4
    • /
    • pp.243-250
    • /
    • 2021
  • Background: Endodontic sealers or their toxic components may become inflamed and lead to delayed wound healing when in direct contact with periapical tissues over an extended period. Moreover, an overfilled sealer can directly interact with adjacent tissues and may cause immediate necrosis or further resorption. Therefore, the treatment outcome conceivably depends on the endodontic sealer's biocompatibility and osteogenic potential. This study aimed to evaluate the cell viability and osteogenic effects of four different sealers in osteoblastic cells. Methods: AH Plus (resin-based sealer), Pulp Canal Sealer EWT (zinc oxide-eugenol sealer), BioRoot RCS (calcium silicate-based sealer), and Well-Root ST (MTA-based calcium silicate sealer) were mixed strictly according to the manufacturer's instructions, and dilutions of sealer extracts (1/2, 1/5 and 1/10) were determined. Cell viability was measured using the water-soluble tetrazolium-8 (WST-8) assay. Differentiation was assessed by alkaline phosphatase (ALP) activity and mineralized nodule formation by Alizarin Red S staining. Results: The cell viability of the extracts derived from the sealers excluding Well-Root ST was concentration dependent, with sealer extracts having the least viability at a 1/2 dilution. At sealer extract dilution of 1/10, the test groups showed the same survival rate as that control group, with the exception of BioRoot RCS. Among all experimental groups, BioRoot RCS showed the highest cell viability after 48 hours. The ALP activity was significantly higher in a concentration-dependent manner. Furthemore, all four materials promoted ALP activity and mineralized nodule formation compared to the control at 1/10 dilutions. Conclusion: This is the first study to highlight the differences in biological activity of these four materials. These results suggest that the composition of root canal sealers appears to alter the form of biocompatibility and osteoblastic differentiation.

Effect of Overlaid White Charcoal Board on the Ethylene Gas Adsorption and Preservation Life of Strawberry (오버레이 백탄보드의 에칠렌가스 흡착과 딸기 보관성 효과)

  • Lee, Hwa-Hyoung;Cho, Youn-Mean;Park, Han-Sang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.86-92
    • /
    • 2004
  • This research was carried out to examine the ethylene gas adsorption and preservation life of white charcoal boards for packaging. Two types of white charcoal board were made of #40-60 charcoal particles and mixed charcoal particles with PVA and MDI resin by wet process. For not only beauty effect but also avoiding stain from touching, white charcoal boards were overlaid with two kinds of overlay material, thin printed paper and non woven fabric. A charcoal board adsorbed ethylene gas much more than the paper and even white charcoal itself. There was no difference between two board types, between overlay treatments, and between overlay materials. Gray mold growth of strawberry arised after 2 days in a paper box and after 4 days in a white charcoal board. Preservation life of white charcoal board box was approximately twice more than that. of a paper box. There was no difference in the ability of keeping freshness between two board types, between overlay treatments, and between overlay materials.

Effects of Precipitation pH of Black Liquor on Characteristics of Precipitated and Acetone-Fractionated Kraft Lignin

  • Ega Cyntia WATUMLAWAR;Byung-Dae PARK
    • Journal of the Korean Wood Science and Technology
    • /
    • v.51 no.1
    • /
    • pp.38-48
    • /
    • 2023
  • Two important steps in utilizing technical kraft lignin (KL) from black liquor to synthesize lignin-phenol-formaldehyde (LPF) resin are its extraction via precipitation and fractionation. However, the effects of precipitation pH and acetone fractionation on the characteristics of hardwood KL have not been studied for LPF resins. Therefore, this paper reports the effects of the precipitation pH of black liquor and acetone fractionation on the characteristics of KL from mixed hardwood species for LPF resins. The precipitation was conducted at various pH levels from 3 to 9 of black liquor to obtain crude KL (C-KL), which was used in acetone fractionation to produce acetone-soluble KL (AS-KL) and acetone-insoluble KL (AI-KL). Precipitation at pH 3 and 9 produced the highest and lowest yields of C-KL, respectively. As expected, the C-KL infrared spectra were similar regardless of the precipitation pH levels. As the pH increased, the molecular weight of C-KL increased. However, the molecular weight of AS-KL and AI-KL after acetone fractionation increased to a maximum of 4,170 and 47,190 g/mol at pH 7, then decreased to 3,210 and 19,970 g/mol at pH 9, respectively. The smallest molecular weights of AS-KL and AI-KL were 3,210 and 15,480 g/mol and were found at pH 9 and 3, respectively. These results suggest that both AS-KL at pH 9 and AI-KL at pH 3 have good potential as starting lignins for synthesizing LPF resins that require cross-linking for polymerization.

Synthesis of UV Curable Polyurethane Adhesives Based on Various Compositions of Mixed Polyol with Improved Adhesion and Flexural Properties (다양한 조성의 혼용 폴리올에 기초한 접착력 및 굴곡성이 향상된 자외선 경화형 폴리우레탄 접착제의 합성)

  • Won-Young Lee;Soo-Yong Park;Guni Kim;Ildoo Chung
    • Journal of Adhesion and Interface
    • /
    • v.23 no.4
    • /
    • pp.137-143
    • /
    • 2022
  • In this study, the polyurethane acrylates (PUA) resin with good adhesive and flexibility for adhesive for shoes and clothing were synthesized using that poly(tetramethylene adiphate glycol) (PTAd), poly(tetramethylene ether glycol) (PTMG) as polyester polyol and polyether polyol respectively, including 4,4'-methylene diphenyl diisocyanate (MDI), isophorone diisocyanate (IPDI), 1,4-butandiol (1,4-BD), 2-hydroxyethyl methacrylate (2-HEMA) and dibutyl amine (DBA). The effect of polyol blend in the polyurethane acrylate on thermal and mechanical properties, adhesion strength and flexural strength were studied. The glass transition temperature (Tg) of PUA was confirmed in range of -70~-40 ℃. In addition, the glass transition temperature (Tg), decomposition temperature (Td), tensile strength adhesion strength and heat resistance were increased as increasing of PTAd amount while the elongation, water resistance and flexural properties were decreased. The synthesized polyurethane acrylate with 5:5 ratio of PTAd and PTMG indicated the highest adhesion strength and flexural properties.

Electrical and the Mechanical Properties of Graphite particle/carbon fiber hybrid Conductive Polymer Composites (흑연입자/탄소섬유 혼합 보강 전도성 고분자 복합재료의 전기적, 기계적 특성 연구)

  • Heo Seong-Il;Yun Jin-Cheol;Oh Kyung-Seok;Han Kyung-Seop
    • Composites Research
    • /
    • v.19 no.2
    • /
    • pp.7-12
    • /
    • 2006
  • Graphite particle/carbon fiber hybrid conductive polymer composites were fabricated by the compression molding technique. Graphite particles were mixed with an epoxy resin to impart the electrical conductivity in the composite materials. In this study, graphite reinforced conductive polymer composites with high filler loadings were manufactured to accomplish high electrical conductivity above 100S/cm. Graphite particles were the main filler to increase the electrical conductivity of composites by direct contact between graphite particles. While high filler loadings are needed to attain good electrical conductivity, the composites becomes brittle. So carbon fiber was added to compensate weakened mechanical property. With increasing the carbon fiber loading ratio, the electrical conductivity gradually decreased because non-conducting regions were generated in the carbon fiber cluster among carbon fibers, while the flexural strength increased. In the case of carbon fiber 20wt.% of the total system, the electrical conductivity decreased 27%, whereas the flexural strength increased 12%.

Preparation and identification of U(IV) for the investigation of behaviors of uranium in a disposal repository (처분장에서 우라늄 거동 규명을 위한 U(IV)의 제조 및 확인)

  • Kim, Seung Soo;Kang, Kwang Chul;Kim, Jung Suck;Jung, Euo Chang;Baik, Min Hoon
    • Analytical Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.143-147
    • /
    • 2008
  • U(IV) ion, the valance state of uranium presumed at in a deep-depth disposal of a spent fuel, was prepared and separated from U(VI) ion. In order to prepare U(IV) ion, tests were performed by adding several reducing agents into a uranyl solution or by dissolution of uranium oxide in a mixed acid added with a reducing agent. The valance states of the uranium in the prepared solutions were identified by separating two ions with a Dowex AG 50W-X8 cation exchange resins and measuring the solutions using a laser-induced fluorescence spectroscopy. However, U(IV) and U(VI) were not separated by a Lichroprep Si60 exchange resin in the same separation condition of Pu(IV) and Pu(VI).

Comparison study between recovered carbon black and commercial carbon black filled epoxy conductive materials

  • Huai M. Ooi;Pei L. Teh;Cheow K. Yeoh;Wee C. Wong;Chong H. Yew;Xue Y. Lim;Kai K. Yeoh;Nor A. Abdul Rahim;Chun H. Voon
    • Advances in materials Research
    • /
    • v.13 no.3
    • /
    • pp.221-232
    • /
    • 2024
  • Waste tire management and recycling have grown to be significant issues because they bring up a global environmental concern. Thus, turning recycled waste tires into useful products may help tackle the environmental issue. This research aims to study and compare the effect of recycled carbon black (rCB) and commercial carbon black (CB) at certain 15 vol. % of filler loading on the mechanical, thermal, morphology and electrical properties of epoxy/CB composites. For this project, epoxy resin, diethyltoluenediamine (DETDA), recovered carbon black (rCB) and commercial carbon black (CB) graded N330, N550, N660 and N774 were mixed and compared accordingly to the formulation determined. The CB content was dispersed in the epoxy matrix using the mechanical mixing technique. The distribution and dispersion of CB in the epoxy matrix affect the characteristics of the conductive composites. rCB content at 15 vol% was selected at fixed content for comparison purposes due to the optimum value in electrical conductivity results. The flexural strength results followed the sequence of rCB>N774>N660>N550>N330. As for electrical conductivity results, epoxy/N330 exhibited the highest conductivity value, while the others achieved a magnitude of X10-3 due to the highest external surface area of N330. In terms of thermal stability, epoxy/N330 and epoxy/N774 were slightly more stable than epoxy/rCB.

The Impact of Amalgam Exposure an Urinary Mercury Concentration in Children (어린이의 구강 내 아말감 노출이 요중 수은농도에 미치는 영향)

  • Jeon, Eun-Suk;Jin, Hye-Jung;Kim, Eun-Kyong;Im, Sang-Uk;Song, Keun-Bae;Choi, Youn Hee
    • Journal of dental hygiene science
    • /
    • v.14 no.1
    • /
    • pp.7-14
    • /
    • 2014
  • This study aims to evaluate the impact of varying exposure to dental amalgam on urinary mercury levels in children by measuring the number of amalgam-filled teeth and the variance of mercury concentration in urine over a period of 2 years. A total of 317 (male 158, female 159) elementary school children (1st~4th graders) attending 2 schools in urban regions participated in this study. At 6-month intervals, 4 oral examinations were conducted to check any variance in the conditions of dental caries and the status of dental fillings. Also, urine tests were conducted followed by a questionnaire survey. To elucidate the factors potentially affecting the mercury concentration in urine, t-test, ANOVA, chi-square test and a mixed model were used for the analysis. Regarding the status of dental fillings in line with examination time periods, deciduous teeth had more amalgam-filled surfaces than those filled with resin, whereas permanent teeth had more resin-filled surfaces than those filled with amalgam. A significant relevance was found between the exposure to dental amalgam and urinary mercury levels. Specifically, subjects whose teeth surfaces had been filled with dental amalgam showed higher urinary mercury levels than those who had no dental amalgam fillings. Based on the analysis using the mixed model, the increase in the number of teeth surfaces filled with amalgam was found to be the factor affecting the increase in urinary mercury levels. The urinary mercury levels were found to be highly associated with the exposure to dental amalgam. The more the teeth surfaces filled with amalgam, the higher the urinary mercury levels. Hence, even a trace of dental amalgam fillings can liberate mercury, affecting the variance in the urinary mercury levels. These findings suggest that some criteria or measures should be developed to minimize the exposure to dental amalgam. Moreover, relevant further studies are warranted.