• 제목/요약/키워드: mixed organic solvent

검색결과 106건 처리시간 0.025초

자동차 정비공의 혈액 및 뇨검사 소견과 자각증상에 대한 조사 (Laboratory Findings and Subjective Symptoms of Car Repair Workers)

  • 이광성;이명구;조영채
    • 한국환경보건학회지
    • /
    • 제24권2호
    • /
    • pp.80-87
    • /
    • 1998
  • To evaluate the effects on health by exposure to low dose organic solvents, the author analyzed the air concentration of mixed organic solvents (toluene, xylene, butylacetate) at worker's breathing zone during painting, some laboratory findings of blood (WBC, RBC, Hb, Hct, SGOT, SGPT, TC, TG, HDL-C, LDL-C, IgG, IgM, IgA and IgE) and urine (hippuric acid, urinary protein, urobilinogen), surveyed the subjective symptoms those were obtained from 35 male workers exposed to mixed organic solvents, and 25 male workers not exposed to organic solvents who worked in car repair workshops in Taejon area from December 1, 1995, to February 29, 1996. The results were as follows: 1. The mean concentration of urinary hippuric acid of car painting worker group (organic solvent exposure group) was 0.76$\pm$ 0.21 g/l, which is significantly higher than that of non-exposed group. 2. In hematologic findings, the values of RBC, TC, LDL-C, IgG and IgE in the exposure group were significantly lower than those of the nonexposed group, but SGOT and SGPT in the exposure group were significantly higher than those of the non-exposed group. 3. Urinary hippuric acid levels showed positively correlated with toluene, urobilinogen and HDL-C levels, but those were negatively correlated with RBC, LDL-C, IgM levels. 4. Rates of the subjective symptoms such as "dizziness", "appetite loss", "weight loss", "palpitation", "chest tightness", "sore throat and eye discomfort", "tingling sense and acrodynia", "illusion or hallucination" and "decreaased motor power" were significantly higher in the exposure group than those of the non-exposed group.

  • PDF

활성탄소계 섬유포 전극을 이용한 전기이중층 커패시터용 유기 전해액의 제조 (Fabrication of Organic Electrolytes for Electric Double Layer Capacitor with Activated Carbon Cloth Electrode)

  • 강안수
    • 대한안전경영과학회지
    • /
    • 제2권2호
    • /
    • pp.95-108
    • /
    • 2000
  • Electrochemical charateristics of activated carbon fiber cloth(ACFC) electrode were studied with propylene carbonate(PC), ${\gamma}$-butyrolactone(GBL) and N,N-dimethyl-formamide(DMF) as a solvent and tetraethylammoniumtetrafluoroborate(TEABF$_4$), tetraethylammoniumhexafluorophosphate(TEABF$_{6}$), tetrabutylammoniumtetrafluoroborate(TBABF$_4$) and tetrabutylammonium hexafluorophosphate(TBAPF$_6$) as an electrolytes(active material). The concentrations of electrolytes were in the range of 0.2~1.2 N, the volume ratios of PC and DMF as a mixed solvent system, were 90:10, 80:20, 70:30, 60:40, 50:50, and 40:60 vol%. Electrochemical characteristics such as electric conductivity, internal resistance, and electric capacitance of fabricated unit cells were measured after the moisture of activated material was removed with molecular sieve. Electrochemical characteristics were better in mixed solvents system than in mono solvent system. The mono solvent system of 1.0 N electrolyte of GBL/TEABF$_4$ with activated carbon cloth electrodes showed better result but the mixed solvent system with PC and DMF/TEABF$_4$(50:50 vol%) and the concentration of 1.0 N electrolyte showed the best characteristics. Internal resistance was 3.47 $\Omega$ and specific capacitance was 19.1 F/g respectively.y.

  • PDF

The Influence of Mixed Solvents Volatility on Charge State Distribution of Peptides During Positive Electrospray Ionization Mass Spectrometry

  • Nielsen, Birthe V.;Abaye, Daniel A.;Nguyen, Minh T.L.
    • Mass Spectrometry Letters
    • /
    • 제8권2호
    • /
    • pp.29-33
    • /
    • 2017
  • Understanding the mechanisms that control and concentrate the observed electrospray ionisation (ESI) response from peptides is important. Controlling these mechanisms can improve signal-to-noise ratio in the mass spectrum, and enhances the generation of intact ions, and thus, improves the detection of peptides when analysing mixtures. The effects of different mixtures of aqueous: organic solvents (25, 50, 75%; v/v): formic acid solution (at pH 3.26) compositions on the ESI response and charge-state distribution (CSD) during mass spectrometry (MS) were determined in a group of biologically active peptides (molecular wt range 1.3 - 3.3 kDa). The ESI response is dependent on type of organic solvent in the mobile phase mixture and therefore, solvent choice affects optimal ion intensities. As expected, intact peptide ions gave a more intense ESI signal in polar protic solvent mixtures than in the low polarity solvent. However, for four out of the five analysed peptides, neither the ESI response nor the CSD were affected by the volatility of the solvent mixture. Therefore, in solvent mixtures, as the composition changes during the evaporation processes, the $pK_b$ of the amino acid composition is a better predictor of multiple charging of the peptides.

2색 중첩 민인쇄의 광학적 해석과 중첩인쇄 순서에 관한 연구 (A Study on Optical Analysis and Overprinting Sequence in 2-Color Solid Overprints)

  • 강상훈
    • 한국인쇄학회지
    • /
    • 제15권2호
    • /
    • pp.1-4
    • /
    • 1997
  • Existing cleaning solvent using screen printing are the organic solvents including aromatic compounds carried with poisonous and stench. besides, Cleaning method of current screen printing are for the most part mixed cleaning method of dipping and polish. Using 1,1,1-TCE, CFC-113 alternative system cleaning solvent be substituted for existing cleaning solvent against screen printing ink measured the cleaning efficiency according to gravimetric analysis method and property change of gassamer according to Image Analyzer. Also, Cleaning process system carry with excellent cleaning efficiency studied which was proposed new cleaning process including ultrasonic cleaning process be substituted for existing mixed cleaning method of dipping and polish.

  • PDF

조선소 도장작업 노동자 유기용제 노출과 일간 변이 (Characteristics of Workers'Exposure Concentration and Daily Variations to Organic Solvents in Shipbuilding Painting Processes)

  • 안진수;박두용;강태선
    • 한국산업보건학회지
    • /
    • 제29권4호
    • /
    • pp.488-499
    • /
    • 2019
  • Objectives: This study was conducted to identify the characterization of organics solvent exposure among painting workers in the shipbuilding painting process, especially for their daily variations(within worker variance). Methods: Charcoal passive dosimeters were worn throughout each work shift for 20 days for five painting workers from October 19 to November 26, 2015. A total of 100 samples were collected, analyzed and compared with statutory workplace environmental measurements. Results: The geometric mean(GM) and geometric standard deviation(GSD) of mixed organic solvent(six substances) exposure index(EI) for the 100 samples were 0.42 and 4.42 respectively. The median and range of GSD for within worker EI representing five workers' daily EI variation is 3.72 and 2.63 ~ 5.20, respectively, which is classified as a very large variation(GSD>3). We were able to divide the painting process into two similar exposure groups(SEGs), Touch-up and Spray. Spray painting workers were much more exposed to organic solvent than Touch-up painting workers(GM=0.71 vs. 0.19), but less variably (GSD=3.64 vs. 4.10). xylene is the substance to which the workers were most exposed(GM=16.19 ppm, GSD=4.36), and the exposure characteristics of six substances including xylene is similar to those of EI. Conclusions: The daily variation of organic solvent exposure in the shipbuilding painting process is so high that statutory Assessment of Reliability of Work Environment Monitoring needs to be conducted with statistically sufficient number of samples and evidence.

Preparation of tungsten metal film by spin coating method

  • Lee, Kwan-Young;Kim, Hak-Ju;Lee, Jung-Ho;Sohn, Il-Hyun;Hwang, Tae-Jin
    • Korea-Australia Rheology Journal
    • /
    • 제14권2호
    • /
    • pp.71-76
    • /
    • 2002
  • Metal thin films, which are indispensable constituents of ULSI (Ultra Large Scale Integration) circuits, have been fabricated by physical or chemical methods. However, these methods have a drawback of using expensive high vacuum instruments. In this work, the fabrication of tungsten metal film by spin coating was investigated. First of all, inorganic peroxopolytungstic acid (W-IPA) powder, which is soluble in water, was prepared by dissolving metal tungsten in hydrogen peroxide and by evaporating residual solvent. Then, the solution of W-IPA was mixed with organic solvent, which was spin-coated on wafers. And then, tungsten metal films, were obtained after reduction procedure. By selecting an appropriate organic solvent and irradiating UV, the sheet resistance of the tungsten metal film could be remarkably reduced.

수-유기용매혼합용매중의 산-염기지원약에 관한 연구 (Behaviour of Acid-Base Indicators in the Aqueous Organic Solutions.)

  • 용군호
    • 약학회지
    • /
    • 제19권1호
    • /
    • pp.30-35
    • /
    • 1975
  • pKi values and sensitivity of acid-base indicators in the mixed solvent systems of water-alcohols and water-acetone at differential pH and in concentration media were determined by spectrophotometric method. When the concentration of the organic solvents were increased, the pKi values of sulfophthalein indicators, thymol blue and bromcresol purple, became larger whereas those of an axo indicator, methyl yellow, became smaller nad the pH values of the equivalent points of acids became smaller and the pH values of the equivalent points of acids became higher than those in the aqueous solution. potassium bicarbonate, a standard compound used in the organic solvent systems without a prerequisite procedure of expelling carbon dioxide by boiling.

  • PDF

드라이클리닝 근로자들의 유기용제 폭로와 자각증상 (Study on the Exposure Levels of Organic Solvents and Subjective Symptoms of Dry-cleaning Workers)

  • 김수영;김정윤;이연경;이석구;이영수;조영채;이태용;이동배
    • Journal of Preventive Medicine and Public Health
    • /
    • 제31권4호
    • /
    • pp.628-643
    • /
    • 1998
  • To investigate the exposure levels of organic solvents and subjective symptoms of dry-cleaning workers, 77 male and 52 female dry-cleaning workers who had been worked in a small city of Chungnam province, and a large city, Taejon were selected for the study group. Air concentrations of organic solvents in the working environment were analyzed, and subjective symptoms of dry-cleaning workers were surveyed, from July to August 1996. The results obtained were as follows : 1. The concentrations of organic solvents in the working environment were within permissible TLV-TWA limits. 2. For the 13 symptom clusters, the most frequently complained symptom clusters were fatigue as 71.3%, and followed by depression and urinary disturbances as 53.5% and 51.9%. Other symptom clusters complained were below 50%. 3. Positive response rates of subjective symptoms were significantly higher in worker groups such as lived in a large city, female, higher education level, more frequently alcohol drinking, higher concentration of organic solvent in working environment, work in alone. 4. Workers who had used solvent B showed 2.3 point higher scores of subjective symptoms than those of solvent A. Of the subjective symptoms scores, amnesia and nervousness were higher in solvent B user group than solvent B user group. 5. As a result of factor analysis, 3 factors such as depression, urinary disturbance and neurologic disturbance were selected. 6. As a result of the logistic regression analysis, sex, the number of fellow workers, working time, region, job tenure, smoking, alcohol drinking, ventilating system, concentration of organic solvent in working environment and place of residence were selected for the related variables. For the conclusion, even though the concentrations of organic solvents in the working environments of dry-cleaning workers were within permissible limit of TLV-TWA, many dry-cleaning workers complained symptoms, such as fatigue, depression, urinary disturbances and so on. And the factors affecting to the symptoms of dry-cleaning workers were the number of fellow workers, work hours, region, job tenure, smoking and alcohol drinking.

  • PDF

AC 및 ACF에 포집된 혼합 유기용제의 열탈착 방법에 따른 분석 및 평가 (Analysis and Assessment by Thermal Desorption Method of Mixed Organic Solvents Collected on Activated Carbon(AC) and Activated Carbon Fiber(ACF))

  • 원정일;김기환;신창섭
    • 환경위생공학
    • /
    • 제16권1호
    • /
    • pp.72-90
    • /
    • 2001
  • This study was conducted to evaluate desorption efficiencies accuracy and precision by $CS_2$ and thermal desorption method for polar and non-polar organic solvents collected on activated carbon(AC), activated carbon fiber(ACF), carbosieve SIII, materials tested were Methyl alcohol, n-Hexane, Benzene, Trichloroethylene, Methyl isobutyl ketone and methyl cellosolve acetate and six different concentration levels of samples were made. The results were as follows ; 1. Accuracy on kind adsorbent and desorption method was low. In case of $CS_2$ desorption solvent, Overall B and Overall CV on AC and ACF were 43% and 6.63%, respectively. In case of thermal desorption method, accuracy of thermal desorption method appeared higher than solvent desorption method by AC 18.0%, 3.54%, ACF 2.6%, 2.57%, Carbosieve SIII 13.7% and 1.97%, respectively. 2. In the concentration level III, accuracy of thermal desorption method on adsorbent was in order as follow ; ACF > Carbosieve SIII > AC in the methyl alcohol and Carbosieve SIII > ACF > AC in the rest of them all subject material and Concentration levels showed good precision at EPA recommend standard (${\leq}{\;}30%$) 3. DEs by type of organic solvent adsorbent and desorption method are as follows ; In the case that desorption solvent is $CS_2$, DE of Methyl alcohol is AC 47.5%, DE of all materials is ACF about 50%. In the case of thermal desorption method, DE of Methyl alcohol is AC 82.0%, ACF 97.4%, Carbosieve SIII 86.3%. DE of the later case is prominently improved more than one of former. In particular, Except that DE of EGMEA is ACF 88.5%, DE of the rest of it is more than 95% which is recommend standard MDHS 72. With the result of this study, in order to measure various organic solvent occurring from the working environment, in the case of thermal desorption method, we can get the accurate exposure assessment, reduce the cost, and use ACF as thermal desorption sorbent which available with easy.

  • PDF