• 제목/요약/키워드: mitigation methods

검색결과 386건 처리시간 0.03초

무주-장수지역에 적용된 급경사지재해 대응공법 현장조사 (Field survey of slope hazards mitigation method in Muju-Jangsu area)

  • 송영석;조용찬;채병곤;김경수;김만일
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.1053-1059
    • /
    • 2009
  • In this study, slope hazards mitigation methods for a natural terrain are systematically classified to survey the mitigation methods and develop a data base system. Also, field survey sheets which can be recorded the features of mitigation methods installed in the natural slope are developed. The slope hazards mitigation methods in the natural slope are classified as hillside part method and valley part method. The slope part sheet and the valley part sheet are also drawn up for field survey. As the result of the filed survey of mitigation methods about 50 points in Muju and Jangsu area, grass painting and slope covering methods are dominant in case of slopes part. In case of valley part, slit dam, concrete check dam and slope foot barrier are applied simultaneously.

  • PDF

건축물 유형에 따른 라돈 저감 효과 평가 (Evaluation for Effectiveness of Radon Mitigation on Dwellings and Public Buildings in Korea)

  • 이동현;류승훈;조정흠;서성철
    • 한국산업보건학회지
    • /
    • 제24권4호
    • /
    • pp.518-527
    • /
    • 2014
  • Objectives: The adverse health effects attributed to exposure to radon have been well known over the world. However, the efforts for prevention and mitigation of radon have not been taken in Korea so far. The purpose of this study was to evaluate the effectiveness of mitigation methods applied for various types of houses and public buildings with high level of radon. Methods: Based on the results of "National Radon Survey" performed by the National Institute of Environmental Research(NIER) in 2010-2012, we selected 30 candidate buildings consisting of 20 houses and 10 public buildings with greater than $148Bq/m^3$ of radon level. We measured the concentration of radon in 30 buildings, using E-PERMs and RAD-7 during January to March of 2013. More than five E-PERMs and one RAD-7 per house were installed for seven days. Ten houses and five public buildings were finally chosen to be mitigated after mainly considering the level of radon and the location of buildings nationwide. Three mitigation methods such as Sealing, two types of Active Ventilation(window-shaped and wall-typed ventilations), and Active Soil Depressurization(ASD) were applied, and the concentrations of radon were measured before and after mitigation, respectively. To evaluate the effectiveness of mitigation methods, reduction rates of radon were calculated and Wilcoxon's signed-rank test was performed. Results: The mean concentration of 15 buildings just before radon mitigation was $297.8Bq/m^3$, and most of the buildings were located in Gangwon, Chungbuk, Chungnam, and Daegu areas(73.3%), and built in 1959-1998. The level of radon decreased from 48% to 90% and kept the below recommendation limit of $148Bq/m^3$ after installation of radon mitigation. Among mitigation methods applied, the reduction rate(58.7-90.4%) of radon attributed to ASD was the greatest than that of other methods, followed by Active Ventilation(48.4-78.4%) and Sealing(<22%). The effectiveness of radon reduction by window-shaped Active Ventilation(63.2-75.2%) was relatively better than that of wall-typed Active Ventilation(48.4-54.3%). Conclusions: The results of this study indicate that ASD could be more effective for radon mitigation. Moreover, our findings would be background information in future for making the strategy for radon mitigation nationwide, as well as for developing Korean-version of mitigation techniques according to types of dwellings in Korea.

낙석대책공법 비용편익분석기법 개발 (Development of Cost-Benefit Analysis Method for Rockfall Mitigation Methods)

  • 신민호;이성혁;김현기;김정기;노순미
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(II)
    • /
    • pp.417-422
    • /
    • 2003
  • Rockfall mitigation methods have been widely constructed along railway lines but aren't estimated with any economic analysis methods up to now. Therefore, this study applied a benefit-cost analysis to rockfall mitigation method to determine whether it is indeed an economically efficient construction. The Benefits were estimated based on data collected from disaster history, and included three types of benefits that are originated by reduction of train accident, train delay and rockfall removing cost. The costs included both construction cost and the maintenance cost of the selected method. This analysis could clarify the investment effect of rockfall mitigation method that would be built at rockfall prone slope.

  • PDF

독일 환경영향평가에서의 자연환경의 평가절차 (Use of Methods and Evaluation Systems of the Impact Mitigation Principle in German EIA)

  • Peters, Wolfgang
    • 환경영향평가
    • /
    • 제2권2호
    • /
    • pp.49-53
    • /
    • 1993
  • Before the EIA was established in the Federal Republic of Germany, the impact mitigation principle - a planning instrument, which has its legal foundation in the German nature conservation legislation already had {and still has} the function to valuate environmental impacts. The valuation principles and methods which have been developed in correlation to this instrument are now also used in the EIA. Particularly for the valuation of alternating effects on the different ecological landscape functions and for the valuation of ecological mitigation and compensation measures this valuation methods are used. These methods base on a special kind of modelling nature and environment Following the aim of the nature conservation act, which is to save the capacity of the landscape to perform its essential functions, not the ecological factors (soil, water, air etc.) itselfs are evaluated but the ecological functions of the landscape, which are based on the ecological factors.

  • PDF

보호철판을 이용한 가스배관 유도전압대책에 관한 연구 (A Study on the Existing Induced Voltage Mitigation Method on Gas Pipelines using Steel Plate)

  • 하태현;이현구;배정효;김대경;이성진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.354-356
    • /
    • 2001
  • The demand of the power and gas energy have been rapidly increasing with the industralization, therefore, the area where buried pipelines run parallel with the adjacent power lines and cross them increases in Seoul as well as other cities. These situation cause AC interference from the power lines. However, there aren't any standards to preserve the pipelines from AC interference in Korea. We just use other country's criteria directly. Other developed countries have used the various AC interference mitigation methods such as lumped grounding. cancellation wires and gradient control wires etc.. This paper introduces the steel plate method which is using for AC interference mitigation method in Korea and investigates the effects of mitigation methods through case study by computer simulation.

  • PDF

국내 토석류 재해 현황 및 피해저감 방안 (The Current States of Debris Flow Hazards and Suggestion of Damage Mitigation Methods in Korea)

  • 채병곤;조용찬;송영석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.302-311
    • /
    • 2008
  • There have been repetitive landslides and debris flows on natural terrain induced by intensive rainfalls which have never been experienced during the last a few decades in Korea. Frequencies and magnitudes of landslides and debris flows are steeply increased after 2000 resulting in huge damages of human beings and facilities. According to a statistical data from NEMA, the human deaths induced by landslides and slope hazards occupies 22.3% of the total human deaths by all the natural hazards in Korea during the last 30 years. Among the human deaths by landslides and slope hazards, 85% of the damages were caused by landslides and debris flows on natural hazards. Therefore, this paper summarizes important events of landslides and debris flows, their characteristics, and suggests some methods of damage mitigation.

  • PDF

직류전기철도의 누설전류 간섭대책(1) 국내 현황 (Mitigation of Stray Current Interference from DC Electric Railroad(1) Domestic Conditions)

  • 하윤철;배정효;하태현;이현구;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.270-272
    • /
    • 2005
  • With the wide spread of direct current (DC) electric railroads in Korea, the stray currents from negative return rails become a pending problem to the safety of nearby underground infrastructures, such as gas pipelines, water distribution lines, heat pipelines, POF cables, etc. The mitigation of such interference, however, is mainly dependent on stray current drainage bond methods, which connect the underground metallic structures to the negative feeder cables attached to the rails with diodes (polarized drainage) or thyristors (forced drainage). Despite some merits of these methods, they increase the total amount of stray currents from rails and cause other interference problems. In this paper, we summarize the domestic conditions of stray current interference and describe a conceptual design of other mitigation methods for such interference.

  • PDF

연안역의 환경과 미티게이션 기술 (Water Environment and Mitigation Technique of Coastal Zone)

  • 최영박
    • 기술사
    • /
    • 제33권1호
    • /
    • pp.51-60
    • /
    • 2000
  • The mitigation technique is to minimize influences to the environments, and it is one of the environmental management(or administration) to techniques. Its objective is to create sustainable environment by keeping human assistance to the environment as minimal as possible. It restores, creates, enhances, and most importantly preserves the environment by avoiding, minizing, rectifying, eliminating, and compensating the natural circumstances The evaluation of adverse effects to the environment and their reduction is as follow: HEP(Habitat Evaluation Procedure) WET(Wet land evaluation technique) HGM(Hydro Geomorphic Assessment) BEST(Biological Evaluation Standardized Technique) Since there are both pro and cons in the American and Japanese mitigation methods, it is hard to choose which one is better.

  • PDF

Recent advances and future potential of anaerobic ceramic membrane bioreactors for wastewater treatment: A review

  • Cha, Minju;Kim, Soyoun;Park, Chanhyuk
    • Membrane and Water Treatment
    • /
    • 제11권1호
    • /
    • pp.31-39
    • /
    • 2020
  • Anaerobic membrane bioreactor (AnMBR) treatment has been widely studied in recent years because of the potential for production of bio-energy from wastewater and energy-positive operation of wastewater treatment plants. Several AnMBR systems, including those that incorporate ceramic membranes, take advantage of enhanced water permeability and low membrane fouling potentials. Given that differences in the ceramic membranes may influence the results of AnMBR studies, relevant details are discussed in this review, which focuses on the profiles of common ceramic membranes used in AnMBR, treatment and filtration performances of different anaerobic ceramic membrane bioreactors (AnCMBRs), and the membrane fouling mitigation methods available for effective AnCMBRs operation. The aim of this review is to provide a comprehensive summary of AnCMBR performance, feed wastewater characteristics, operating conditions, and the methods available for effective fouling mitigation.

Classification and Comparison of EMI Mitigation Techniques in Switching Power Converters - A Review

  • Yazdani, Mohammad Rouhollah;Farzanehfard, Hosein;Faiz, Jawad
    • Journal of Power Electronics
    • /
    • 제11권5호
    • /
    • pp.767-777
    • /
    • 2011
  • Power electronic systems such as switching power supplies are accounted as noise sources for other sensitive circuits. EMI caused by power converters can disturb the normal operation of the converter and other adjacent systems. Major research is concentrated on EMI mitigation for power converters in which the main concern is compliance with EMC standards to ensure proper operation of converters and nearby systems. This paper reviews EMI reduction techniques related to switching power converters with emphasis on the conducted EMI. A comprehensive review of significant research works is performed and various methods are thoroughly discussed and compared. Also, a classification of methods is presented. Moreover, converter prototypes are realized which contain several EMI mitigation techniques and their effects are presented via experimental results.