• Title/Summary/Keyword: mitigate

Search Result 2,520, Processing Time 0.026 seconds

Optimum Locations of Passe Conductor Loops for Magnetic Field Mitigation of Transmission Line using GA (유전 알고리듬을 이용한 송전선로 자계 저감용 도체루프의 최적 위치 선정)

  • Shin Myong-Chul;Kim Jong-Hyung
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.5
    • /
    • pp.234-241
    • /
    • 2005
  • The performance of passive conductor loop (hereinafter 'loop') method which is used to mitigate the magnetic field around overhead power transmission line is dependent on its configuration and installed location, which are affected by installation conditions of the loops such as objective areas and levels of magnetic field mitigation. Thus, because the design problem of loops is difficult and cumbersome by variety of their configuration and complexity of magnetic coupling mechanism, it is need to be formulated as a computer-based optimum problem to determine the most effective and reasonable loop model satisfying the installation conditions. In this paper, the optimum locations of the multi-wired multiple loops including series reactance compensations are searched by using the genetic algorithm (GA) to mitigate effectively the magnetic fields of relatively near points or far points from transmission line at Am height, and the magnetic fields mitigation characteristics of each loop are analyzed in the view of magnitude, direction and phase of cancellation fields by polarized vector concept to identify their adequacy and rationality for the installation objectives.

A Study on the Legal Assessment and Cases of Damages under CISG (국제물품매매계약에 관한 UN협약(CISG)상 손해배상액 산정기준의 해석과 적용)

  • Shim, Chong-Seok
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.55
    • /
    • pp.3-32
    • /
    • 2012
  • CISG article 74 establishes the general formula applicable in all cases where an aggrieved party is entitled to recover damages. It provides that damages for breach of contract comprise all losses, including loss of profits, caused by the breach, to the extent that these losses were foreseeable by the breaching party at the time the contract was concluded. An aggrieved party may claim under article 74 even if entitled to claim under article 75 or 76. The latter articles explicitly provide that an aggrieved party may recover additional damages under article 74. Articles 75 and 76 apply only in cases where the contract has been avoided. Article 75 measures damages concretely by reference to the price in a substitute transactions, while article 76 measures damages abstractly by reference to the current market price. Article 76 (1) provides that an aggrieved party may not calculate damages under article 76 if it has concluded a substitute transaction under article 75. If however, an aggrieved party concludes a substitute transaction for less than the contract quantity, both articles 75 and 76 may apply. Pursuant to article 77, damages recoverable under articles 74, 75 or 76 are reduced if it is established that the aggrieved party failed to mitigate losses. The reduction is the amount by which the loss should have been mitigated. Article 78 entitles a party to interest on the price and any other sum that is in arrears.

  • PDF

Control of a building complex with Magneto-Rheological Dampers and Tuned Mass Damper

  • Amini, F.;Doroudi, R.
    • Structural Engineering and Mechanics
    • /
    • v.36 no.2
    • /
    • pp.181-195
    • /
    • 2010
  • Coupled building control is a viable method to protect tall buildings from seismic excitation. In this study, the semi-active control of a building complex is investigated for mitigating seismic responses. The building complex is formed of one main building and one podium structure connected through Magneto-Rheological (MR) Dampers and Tuned Mass Damper. The conventional semi-active control techniques require a primary controller as a reference to determine the desired control force, and modulate the input voltage of the MR damper by comparing the desired control force. The fuzzy logic directly determines the input voltage of an MR damper from the response of the MR damper. The control performance of the proposed fuzzy control technique for the MR damper is evaluated for the control problem of a seismically-excited building complex. In this paper, a building complex that include a 14-story main building and an 8-story podium structure is applied as a numerical example to demonstrate the effectiveness of semi-active control with Magneto-Rheological dampers and its comparison with the passive control with the Tuned Mass Damper and two uncoupled buildings and hybrid semi-active control including the Tuned Mass Damper and Magneto-Rheological dampers while they are subject to the earthquake excitation. The numerical results show that semi-active control and hybrid semi-active control can significantly mitigate the seismic responses of both buildings, such as displacement and shear force responses, and fuzzy control technique can effectively mitigate the seismic response of the building complex.

Analysis of Street Trees and Heat Island Mosaic in Jung-gu, Daegu (대구광역시 중구의 가로수 및 열섬 모자이크 현황 분석)

  • Kim, Soo-Bong;Jung, Eung-Ho;Kim, Gi-Ho
    • Journal of Environmental Science International
    • /
    • v.15 no.4
    • /
    • pp.325-332
    • /
    • 2006
  • The purpose of this paper is to suggest practical suggestions to mitigate Urban Heat Island(UHI) problems in Daegu regarding urban surface temperature. Urban street trees's size and the relations between urban land use types and surface temperature are analysed using aerial photos, the numerical value map and Landsat TM image with special reference to Jung-gu. Total urban street tree's crown size is $156,217.6m^2$ and it is equal to 2.24% of study area. In addition, the size of 'city and residential area' is $6,681,870m^2$(95.7% of study area), which causes UHI and the total size of 'river' shows the lowest surface temperature area and 'road' and 'business and service area' are the highest surface temperature zones. Therefore, it is probable that the network between urban street trees and the lowest surface temperature areas mitigate UHI effects.

A Method of Avoid flooding in the Cluster (클러스터 내의 플러딩 회피 방안)

  • Kim, Tae-Wook;Sang, Nguyen Quang;Tuan, Van Phu;Kong, Hyung-Yun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.677-680
    • /
    • 2015
  • In this paper, we propsed scheme to mitigate conflict and loss of message in vehicle communication. And vehicles that exist in the moving direction, were grouping to the cluster form. Through, to select best relay vehicle, transmit a message to the destination. In addition, we applied the double rayleigh fading environment so that can applied in real-environments. Therefore, vehicle communication network applied proposed scheme, can be problem of mitigate conflict and loss of message. Thus, Increase the reliability of the received signal.

  • PDF

Non-equal DC link Voltages in a Cascaded H-Bridge with a Selective Harmonic Mitigation-PWM Technique Based on the Fundamental Switching Frequency

  • Moeini, Amirhossein;Iman-Eini, Hossein;Najjar, Mohammad
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.106-114
    • /
    • 2017
  • In this paper, the Selective Harmonic Mitigation-PWM (SHM-PWM) method is used in single-phase and three-phase Cascaded H-Bridge (CHB) inverters in order to fulfill different power quality standards such as EN 50160, CIGRE WG 36-05, IEC 61000-3-6 and IEC 61000-2-12. Non-equal DC link voltages are used to increase the degrees of freedom for the proposed SHM-PWM technique. In addition, it will be shown that the obtained solutions become continuous and without sudden changes. As a result, the look-up tables can be significantly reduced. The proposed three-phase modulation method can mitigate up to the 50th harmonic from the output voltage, while each switch has just one switching in a fundamental period. In other words, the switching frequency of the power switches are limited to 50 Hz, which is the lowest switching frequency that can be achieved in the multilevel converters, when the optimal selective harmonic mitigation method is employed. In single-phase mode, the proposed method can successfully mitigate harmonics up to the 50th, where the switching frequency is 150 Hz. Finally, the validity of the proposed method is verified by simulations and experiments on a 9-level CHB inverter.

The Model Proposal of Mobile Cloud Security Technology (모바일 클라우드 보안기술의 모델 제안)

  • Shin, Seung-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.6
    • /
    • pp.151-156
    • /
    • 2011
  • The Korean domestic cloud market will reach a value of 2 trillion Korean won by 2014. The domestic market is expected to grow rapidly in size despite the fact that there exist activation barriers in mobile cloud services, concerns about the reliability of service, and concerns about security and confidentiality of data. Under these circumstances, existing IT security technologies may be be utilized to provide sufficient response characteristics. Despite this, they must be optimized for mobile cloud computing and enhanced to mitigate inherent security flaws. In this study, mobile cloud security is covered along with use cases that cover the cases where mobile devices are particularly vulnerable and suggest ways to mitigate security vulnerabilities.

Comparative Simulation of flicker Mitigating Efficiencies of Various Compensating Devices using Matlab/Simulink (Matlab/Simulink를 이용한 무효전력 보상장치의 플리커 저감 효과 연구)

  • Jung, Jae-Ahn;Cho, Soo-Hwan;Jang, Gil-Soo;Kang, Moon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.83-84
    • /
    • 2008
  • Voltage fluctuation, also known as flicker, is a power quality problem caused by nonlinear loads like electric arc furnace. Since it is interpreted as a variation of the supplied electrical energy, it causes the residential customers to feel much annoyed visually through the lamps. Due to the statistical nature of IEC (International Electrotechnical Commission) short-term flicker severity index, Pst, it is not feasible to pre-evaluate the flicker level using the transient power system simulators such as Sim Power System in Matlab/Simulink. So this paper presents not only how to design the Matlab/Simulink IEC flickermeter to yield the Pst value, which considering electric distribution environments of South Korea, but also how to mitigate the voltage flicker at the Point of Common Coupling (PCC). In order to achieve this, the flicker mitigation efficiencies of various compensating devices, such as Static Var Compensator (SVC), STATCOM will be applied and compared. The simulated result demonstrates which compensating equipment is the most efficient method to mitigate the flicker phenomenon.

  • PDF

Simplified Control Scheme of Unified Power Quality Conditioner based on Three-phase Three-level (NPC) inverter to Mitigate Current Source Harmonics and Compensate All Voltage Disturbances

  • Salim, Chennai;Toufik, Benchouia Mohamed
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.544-558
    • /
    • 2013
  • This paper proposes a simplified and efficient control scheme for Unified Power Quality Conditioner (UPQC) based on three-level (NPC) inverter capable to mitigate source current harmonics and compensate all voltage disturbances perturbations such us, voltage sags, swells, unbalances and harmonics. The UPQC is designed by the integration of series and shunt active filters (AFs) sharing a common dc bus capacitor. The dc voltage is maintained constant using proportional integral voltage controller. The shunt and series AF are designed using a three-phase three-level (NPC) inverter. The synchronous reference frame (SRF) theory is used to get the reference signals for shunt and the power reactive theory (PQ) for a series APFs. The reference signals for the shunt and series APF are derived from the control algorithm and sensed signals are injected in tow controllers to generate switching signals for series and shunt APFs. The performance of proposed UPQC system is evaluated in terms of power factor correction and mitigation of voltage, current harmonics and all voltage disturbances compensation in three-phase, three-wire power system using MATLAB-Simulink software and SimPowerSystem Toolbox. The simulation results demonstrate that the proposed UPQC system can improve the power quality at the common connection point of the non-linear load.

Utilization of aerobic granulation to mitigate membrane fouling in MBRs

  • Iorhemen, Oliver T.;Hamza, Rania A.;Tay, Joo Hwa
    • Membrane and Water Treatment
    • /
    • v.8 no.5
    • /
    • pp.395-409
    • /
    • 2017
  • Membrane bioreactor (MBR) is a compact and efficient wastewater treatment and reclamation technology; but, it is limited by membrane fouling. The control of membrane fouling significantly increases operational and maintenance costs. Bacteria and their byproducts - extracellular polymeric substances (EPS) - are major contributors to membrane fouling in MBRs. A recent attempt at fouling mitigation is the development of aerobic granular sludge membrane bioreactor (AGMBR) through the integration of a novel biotechnology - aerobic granulation - and MBR. This paper provides an overview on the development of AGMBR to mitigate membrane fouling caused by bacteria and EPS. In AGMBR, EPS are used up in granule formation; and, the rigid structure of granules provides a surface for bacteria to attach to rather than the membrane surface. Preliminary research on AGMBR using synthetic wastewater show remarkable membrane fouling reduction compared to conventional MBR, thus improved membrane filtration. Enhanced performance in AGMBR using actual municipal wastewater at pilot-scale has also been reported. Therefore, further research is needed to determine AGMBR optimal operational conditions to enhance granule stability in long-term operations and in full-scale applications.