• 제목/요약/키워드: mirrors

검색결과 491건 처리시간 0.036초

DIFFRACTION ANALYSIS OF LAMOST - TWO SEGMENTED MIRRORS INCLUDED

  • Xu WENLI
    • 천문학회지
    • /
    • 제29권spc1호
    • /
    • pp.399-400
    • /
    • 1996
  • LAMOST is a special reflecting Schmidt telescope. Both the refleting Schmidt plate $M_A$ and the spherical primary mitrror $M_B$ are segmened mirrors. These two cofocus but not co-phase. The diffraction of the optical system is decided by the shape overlapping of $M_A$ and $M_B$. This paper describes the diffraction caculating results with different declination and different field angle. The diffraction influence to the image quality is acceptable in the error buget of optical system. It also proves that the size seletion of the sub-mirror is reasonable.

  • PDF

스위칭 가능한 거울을 이용한 광 크로스 커넥스 (optical cross connects based on switchable mirrors)

  • 김정호;이병호
    • 한국광학회지
    • /
    • 제11권3호
    • /
    • pp.163-165
    • /
    • 2000
  • 한 쌍의 파장 다중화기/역 다중화기와 스위칭 가능한 거울을 이용한 새로운 구조의 광 크로스 커넥트를 제안하였다. 실험에서는 스위칭 가능한 거울로써 $2\times2$ 광스위치에 루프(loop) 구조의 광섬유 거울을 연결한 것을 사용하여 제안된 구조의 광 크로스 커넥트의 성능을 광스펙트럼의 영역에서 검증하였다.

  • PDF

IGRINS : Mirror Mounts Optomechanical Design

  • ;박찬;이성호;;이한신;오희영;정화경;육인수;;김강민;천무영
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.155.1-155.1
    • /
    • 2011
  • The Korea Astronomy and Space Science Institute (KASI) and the Department of Astronomy at the University of Texas at Austin (UT) are developing a near infrared wide-band high resolution spectrograph, IGRINS (Immersion Grating Infrared Spectrograph). The white-pupil design of the instrument optics uses 7 cryogenic mirrors including 3 aspherical off-axis collimators and 4 flat fold mirrors. Two of the 3 collimators are H- and K-band pupil transfer mirrors and they are designed as compensators for the system alignment in each channel. Therefore, their mount design will be one of the most sensitive parts in the IGRINS optomechanical system. The other flat fold mirrors are designed within the limited area. Each of those includes the features of 3 axial hard points and 2 radial hard points with one spring plunger in order for the proper deflection of the mirror. The design work will include the computer-aided 3D modeling and finite element analysis (FEA) to optimize the structural stability and the thermal behavior of the mount models. The mount body will also include a tip-tilt and translation adjustment mechanism to be used as the alignment compensators.

  • PDF

직경 300 mm 광집속장치의 광학정렬 (Assembly of diameter 300 mm optical beam director)

  • 양호순;이윤우;김정주;엄해동;이수상;김연수;김현숙
    • 한국광학회지
    • /
    • 제16권6호
    • /
    • pp.521-526
    • /
    • 2005
  • 우리는 국내에서 처음으로 직경 300 mm인 광집속장치를 정렬 및 조립하였다. 이 장치는 주경, 부경 그리고 5개의 연결 거울로 구성된다. 이중에서 가장 중요한 부품인 주경은 각 구조물들과의 조립때마다 발생할 수 있는 변형을 정밀 측정하였다. 또한 사용되는 거울의 개수가 많기 때문에 광학정렬에는 체계적인 정렬 알고리즘을 도입하였다. 최종 조립결과 파면수차는 1.9 wave rms(wave =633 nm)로 예상치의 7배정도 큰 값이었다. 이것의 주원인은 조립 과정에서 발생한 연결 거울들의 변형인 것으로 확인되었다. 본 광집속장치를 정렬하면서 발생했던 문제점들에 대한 고찰은 향후 대형광학계를 만들 때 유용하게 사용될 수 있다.

컴퓨터 제작 홀로그램과 데오도라이트를 이용한 인공위성 카메라 주 반사경의 정점 좌표 측정 (Measurement of Primary-mirror Vertex Coordinates for a Space Camera by Using a Computer-generated Hologram and a Theodolite)

  • 강혜은;송재봉;양호순;김학용
    • 한국광학회지
    • /
    • 제28권4호
    • /
    • pp.146-152
    • /
    • 2017
  • 우주용 인공위성 카메라를 구성하는 반사경의 정렬은 광학계의 고분해능, 고성능을 얻기 위한 중요한 과정 중 하나이다. 반사경들의 상호정렬에는 큐브미러(cube mirror)가 대신 사용되기 때문에, 각 반사경과 해당 큐브미러 간의 상호위치관계 정보가 우선 필요하다. 따라서 우주용 카메라 반사경들의 정렬을 위해 각 반사경의 정점과 해당 큐브미러의 상대 좌표값을 정확하게 측정해야하며, 본 논문에서는 컴퓨터 제작 홀로그램(computer-generated hologram, CGH)의 정렬용 세그먼트와 광섬유를 이용하는 새로운 측정 시스템을 제안함으로써 우주용 카메라를 구성하는 반사경의 정점을 요구조건 이내로 측정할 수 있었다. 측정 시스템은 광학계 평가용 간섭계, CGH, 광섬유, 반사경으로 구성되어 있으며, 최종적으로 데오도라이트를 이용해 큐브미러를 기준으로 주 반사경의 정점에 위치한 광섬유 끝단의 3차원 상대 좌표값을 $25{\mu}m$ 이하의 정밀도로 측정할 수 있었다.

KASINICS 오프닝 광학계의 부품 가공 및 정렬 (FABRICATION AND ALIGNMENT OF PARTS OF THE KASINICS OFFNER SYSTEM)

  • 목승원;이성호;육인수;박영식;진호;한정열;문봉곤;차상목;김건희;임명신
    • 천문학논총
    • /
    • 제21권2호
    • /
    • pp.43-49
    • /
    • 2006
  • The KASINICS (KASI Near Infrared Camera System) is a ground-based Near-Infrared (NIR) imaging instrument developed by the Korea Astronomy and Space Science Institute (KASI). In this paper, we report the test results of the KASINICS camera optics system which is comprised of a 1-1 Offner relay. We measure that the surface RMS fluctuations of the Offner mirrors are at the level of $10^{-1}-10^{-2}$ of the target wavelengths, showing that the mirrors are sufficiently smooth for NIR observations. The alignment of the Offner optics system has been checked too. Our ray-tracing simulations find that the image quality should not degrade more than the pixel size of the KASINICS ($40{\mu}m$), if a de-centering or a tilt of the Offner mirrors are within 5mm, or $2.5^{\circ}$. Our measurement shows that the de-centering or the tilt of the Offner mirrors are less than 1 mm or $0.5^{\circ}$, assuring that the KASINICS image quality are not affected by the alignment errors. We have also measured that the optics resolution is $20{\mu}m$ and it does not degrade more than 10% over the detector surface area of 14.3 mm ${/times}$ 14.3mm. Overall, we conclude that the KASINICS optics system satisfies the design requirements for NIR imaging observations.

고리형 Enhancement Cavity 를 이용한 저출력 반도체 레이저의 제2조화파 발생 (Second Harmonic Generation of Low Power Laser Diode Using a Ring Enhancement Cavity)

  • 오차환
    • 한국광학회지
    • /
    • 제4권2호
    • /
    • pp.206-211
    • /
    • 1993
  • $LilO_3$ 결정에서 최대 출력 30mW의 저출력 CW 반도체레이저에 대한 제2조화파 발생 실험을 실시하였다. 두개의 오목 거울과 두개의 평면 거울로 이루어진 고리형 enhancement 공진기를 이용하여 제2조화파 변환 효율을 증가시켰다. 사용된 오목 거울의 곡률 반경은 50mm 이었고, $LilO_3$ 결정은 길이 5mm와 10mm의 두 개를 사용하였다. 펌핑 출력에 따른 제2조화파의 출력을 측정하고 이론값과 비교 하였다. 794nm의 펌프출력이 28mW 일 때 10mm의 $LilO_3$ 결정에서 $6.6{\mu}W$의 397 nm 출력을 얻을 수 있었다.

  • PDF

Development of Multiple Beam Optical Tweezers

  • Lee Dong-Jin;LeBrun Thomas W.;Balijepalli Arvind;Gorman JasonJ.;Gagnon Cedric;Hong Dae-Hie;Chang Esthe rH.
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1501-1506
    • /
    • 2005
  • This paper presents the design of a multiple beam optical tweezers instrument used for manipulating micro/nano-sized components. The basic equations used in designing the optical tweezers are derived and the stable and time-sharing multiple beam optical tweezers are constructed with scanning mirrors. The laser beam passes through a series of optical components such as lenses, mirrors, and scanning mirrors, and overfills the entrance aperture of microscope objective, which gives a stable trap. By rotating the laser beam with the scanning mirror, the focal positions are translated in the specimen plane and multiple micro/nano-sized objects can be moved. The constructed optical tweezers is used to manipulate cells and liposomes simultaneously and to trap multiple nano-wires. The experiments prove that the developed optical tweezers can be a very versatile manipulation tool for studying gene therapy and nano device fabrication.

  • PDF

IGRINS : Collimating Mirror Mount Opto-mechanical Design

  • Rukdee, Surangkhana;Park, Chan;Chun, Moo-Young;Yuk, In-Soo;Lee, Sung-Ho;Lee, Han-Shin;Kim, Kang-Min;Jeong, Hwa-Kyung;Strubhar, Joseph;Jaffe, Daniel T.
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2011년도 한국우주과학회보 제20권1호
    • /
    • pp.30.4-31
    • /
    • 2011
  • The Korea Astronomy and Space Science Institute (KASI) and the Department of Astronomy at the University of Texas at Austin (UT) are developing a near infrared wide-band high resolution spectrograph, IGRINS (Immersion Grating Infrared Spectrograph). The white-pupil design of the instrument optics uses 7 cryogenic mirrors including 3 aspherical off-axis collimators and 4 flat fold mirrors. Two of the 3 collimators are H- and K-band pupil transfer mirrors and they are designed as compensators for the system alignment in each channel. Therefore, their mount design will be one of the most sensitive parts in the IGRINS optomechanical system. The design work will include the computer-aided 3D modeling and finite element analysis (FEA) to optimize the structural stability of the mount models. The mount body will also include a tip-tilt and translation adjustment mechanism to be used as the alignment compensators.

  • PDF

단안렌즈 스테레오를 이용한 깊이 지도 (Depth Map Using New Single Lens Stereo)

  • Changwun Ku;Junghee Jeon;Kim, Choongwon
    • 한국정보통신학회논문지
    • /
    • 제4권5호
    • /
    • pp.1157-1163
    • /
    • 2000
  • 논문에서 우리는 한 대의 카메라 전면에 위치한 4개의 거울을 이용한 실질적인 스테레오 비젼 시스템을 제안한다. 스테레오 이미지는 한 대의 CCD 카메라 정면에 위치한 4개의 거울을 이용하여 좌/우 이미지가 절반씩 만들어진다. 3차원 공간에서 물체 위의 한 점은 4개의 거울로 인해 2개의 가상 점으로 변환된다. 전통적인 스테레오 비젼 시스템과 같이 2개 가상 점이 위치한 좌/우 이미지 사이의 변위는 물체 위의 점에 대 한 깊이와 직접 관련이 된다. 그러므로 이 시스템은 카메라가 한 대만 사용해 카메라 교정과 스테레오 이미지 획득에 큰 장점이 있다.

  • PDF