• Title/Summary/Keyword: minimum area

Search Result 1,955, Processing Time 0.03 seconds

Plot Size for Investigating Forest Community Structure(III) -Adequate Plot Area of Shrub Stratum in a Pinus densiflora Forest at Chuwangsan Area- (삼림군집구조 조사를 위한 조사구 크기에 관한 연구(III) -주왕산지역 소나무림의 관목층 적정 조사구 면적-)

  • 박인협;문광선
    • Korean Journal of Environment and Ecology
    • /
    • v.8 no.2
    • /
    • pp.150-153
    • /
    • 1995
  • A Pinus densiflora forest in Chuwangsan was studied to determine the adequate plot area of shrub stratum for investigating forest community structure. Nineteen nested plots were set up in the studied forest, and species-area curve and performance curve were established. According to species-area curve, the minimum plot area where a given percentage increase in plot area produced less than the same percentage increase in number of species was 900$m^2$. The minimum plot area where a given percentage increase in plot area produced less than the half of the percent-age increase in number of species was 1,500$m^2$. According to performance curve of the importance values of the major species, the minimum plot area where the importance value of the major species was distinguished from each other was 1,400$m^2$. According to performance curve of species diversity, the minimum plot area was 750-1,500$m^2$. Similarity indices between plot area above 900$m^2$ and total plot area were more than 90% and similarity indices between plot area above 625$m^2$ and total plot area were more than 85%. It may be given as a conclusion that minimum plot area was about 1,500$m^2$ in case of requiring more accuracy.

  • PDF

The Weather Characteristics of Frost Occurrence Days for Protecting Crops against Frost Damage (서리 피해 방지를 위한 서리 발생일의 기상 특성에 대한 연구)

  • Kwon, Young-Ah;Lee, Hyo-Shin;Kwon, Won-Tae;Boo, Kyung-On
    • Journal of the Korean Geographical Society
    • /
    • v.43 no.6
    • /
    • pp.824-842
    • /
    • 2008
  • The main objective of the study was to analyze the weather conditions of frost occurrence for protecting crops against frost damage in Korea. The primary data used for the analysis of meteorological characteristics of frost occurrence days are the airmass pattern, minimum temperature, grass minimum temperature, daily temperature range, relative humidity, minimum relative humidity, mean wind speed in autumn and spring. Frost often occurs when the migratory anticyclone passes the southwest of Korea. The importance of grass minimum temperature measurements for agricultural purposes has previously been recognized. The grass minimum thermometer is capable of detecting ground frosts which are often not recorded by the minimum thermometer. The minimum temperature of frost occurrence days is above $0^{\circ}C$ in the coastal area, but the grass minimum temperature of frost occurrence days is below $0^{\circ}C$ in the whole area. The daily temperature of frost occurrence days is about 9 to $12^{\circ}C$ in the coastal area and is over $14^{\circ}C$ in the inland area. The minimum relative humidity of frost occurrence days is about 30 to 50%. The mean wind speed of frost occurrence days is less than 2m/sec.

A Study on Prediction of Hourly Cooling Load Using Building Area (건물 면적을 이용한 시간별 냉방부하 예측에 관한 연구)

  • Yoo, Seong-Yeon;Han, Kyu-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.11
    • /
    • pp.798-804
    • /
    • 2010
  • New methodology is proposed to predict the hourly cooling load of the next day using maximum/minimum temperature and building area. The maximum and minimum temperature are obtained from forecasted weather data. The cooling load parameters related to building area are set through a database provided from reference buildings. To validate the performance of the proposed method, the predicted cooling loads in hourly bases are calculated and compared with the measured data. The predicted results show fairly good agreement with the measured data for benchmarking building.

A Study on the Thermal Characteristics of Midsummer in Daegu Metropolitan Area

  • Park, Myung-Hee;Lee, Joon-Soo;Ahn, Won-Shik;Kim, Hae-Dong;Oh, Sung-Nam
    • Journal of Environmental Science International
    • /
    • v.22 no.6
    • /
    • pp.667-677
    • /
    • 2013
  • This study aims to examine the actual status of the urban heat island in Daegu by analyzing the data of 17 automatic weather stations installed in the Daegu area. And the results can be summarized as follows: First, regarding the temperature distribution in Daegu by summer time zones, for the 31 days(August 1st till 31st), 18 days showed daily maximum temperature over $30^{\circ}C$, and 11 days indicated daily minimum temperature over $25^{\circ}C$. The day that showed the highest daily maximum temperature was August 5th, which indicated $36^{\circ}C$. Second, about the spatial distribution of time ratio exceeding $30^{\circ}C$ and $25^{\circ}C$, the area with the highest time ratio exceeding $30^{\circ}C$ is mostly the downtown(central area), eastern area, and northern area. Meanwhile, regarding the time ratio exceeding $25^{\circ}C$, the downtown area centering around the central area were high as over 70%, and the outskirts were low as under 65%. Third, considering the temporal distribution of daily maximum temperature and daily minimum temperature, daily maximum temperature was shown around 14:00 to 15:00 while the daily minimum temperature was indicated around 17:00 to 18:00. Daily maximum and minimum temperature were appeared at northeast and downtown, respectively. Fourth, regarding the spatial distribution of tropical days and tropical night days, tropical days showed 77% and tropical night days indicated 42% before and after the 24th and also the 13th each. Tropical days were occurred up to 24 days at northeastern area. And the southwestern area of Daegu showed under 22 days. The downtown showed the 14 days of the tropical night. However, the outskirts indicated relatively few days as under 10 days. Fifth, about the spatial distribution of the average daily temperature range (the difference between the highest temperature and lowest temperature), the central area, the central part of the city, showed the smallest as $7.2^{\circ}C$, and as it was closer to the northern area, it became larger, so in the eastern and northern area, it was over $8.8^{\circ}C$ or so.

The cooling effect of a paddy field area during summer (여름철 논에서의 기온저감 효과)

  • Song, Chul-Min;Kim, Jin-Soo;Park, Jong-Hwa;Jeong, Gu-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1497-1500
    • /
    • 2006
  • The cooling effect of paddy fields was compared with those of other land-use areas (upland, urban park, and urban residential area) during midsummer. The temperature were monitored using data logger at one hour intervals in study sites. Diurnal temperature range of study areas in clear days was larger than in cloudy days. Also, diurnal temperature ranges in paddy field, upland, and park areas were larger than those in the urban residential area during clear days. The paddy field or upland area has shown more remarkable cooling effect compared to urban residential areas: Mean duration of temperature below $25^{\circ}C$ in the paddy field area is longer(7 to 8 hours) than in the residential area; The time to fall to below $25^{\circ}C$ in the paddy field area is sooner than in the residential area; Mean daily minimum temperature in the paddy field area is much lower than in the residential area.

  • PDF

A Study on Minimum Separation Distance for Aboveground High-pressure Natural Gas Pipelines (지상 고압 천연가스 배관의 최소 이격거리 기준에 관한 연구)

  • Lee, Jin-Han;Jo, Young-Do
    • Korean Chemical Engineering Research
    • /
    • v.57 no.2
    • /
    • pp.225-231
    • /
    • 2019
  • In Korea, the minimum separation distance between aboveground high-pressure natural gas pipeline and buildings is regulated by Korea gas safety (KGS) code. In this paper, The technical backgrounds for the revision of the KGS code related to the minimum separation distance was presented. A consequence-based approach was adopted to determine the minimum separation distance by a reasonable accident scenario, which was a jet fire caused by the rupture of one inch branch line attached the gas pipeline. Where, the higher thermal radiation flux threshold was selected for workers in industrial area than for people in non-industrial area, because the workers in industrial area were able to escape in a shorter time than the people in public. As result of consequence analysis for the accident scenario, we suggested the KGS code revision that the minimum separation distances between high-pressure natural gas pipeline installed above ground and buildings should be 30 meter in non-industrial area and 15 meter in industrial area. The revised code was accepted by the committee of the KGS code and now in effect.

Optimal area for rectangular isolated footings considering that contact surface works partially to compression

  • Vela-Moreno, Victor Bonifacio;Luevanos-Rojas, Arnulfo;Lopez-Chavarria, Sandra;Medina-Elizondo, Manuel;Sandoval-Rivas, Ricardo;Martinez-Aguilar, Carmela
    • Structural Engineering and Mechanics
    • /
    • v.84 no.4
    • /
    • pp.561-573
    • /
    • 2022
  • This paper presents a new model to obtain the minimum area of the contact surface for rectangular isolated footings, considering that the contact surface works partially to compression (a part of the contact surface of the footing is subjected to compression and the other is not in compression or tension). The methodology is developed by integration to obtain the axial load "P", moment around the X axis "Mx" and moment around the Y axis "My". This document presents the simplified and precise equations of the four possible cases of footing subjected to uniaxial bending and five possible cases of footing subjected to biaxial bending. The current model considers the contact area of the footing that works totally in compression, and other models consider the contact area that works partially under compression and these are developed by very complex iterative processes. Numerical examples are presented to obtain the minimum area of rectangular footings under an axial load and moments in two directions, and the results are compared with those of other authors. The results show that the new model presents smaller areas than the other authors presented.

창원지역 지하수 수질과 DRASTIC에 의한 지하수 오염취약성 평가

  • 김무진;함세영;정재열;장성;차용훈
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.459-462
    • /
    • 2004
  • This study assesses groundwater vulnerability to contaminants in 12 administrative districts of the city of Changwon, using DRASTIC technique. DRASTIC was originally applied to situations in which the contamination sources are at the ground surface, and the contaminants flow into the groundwater with infiltration of rainfall. However, groundwater contamination in urban areas can also be related to excessive pumping resulting in a lowering of the water level. The correlation coefficient between minimum DRASTIC indices and the degree of poor water quality for 10 districts is low as 0.40. The correlation coefficients between minimum DRASTIC indices and the groundwater discharge rate, and between minimum DRASTIC indices and well density per unit area are 0.70 and 0.87, respectively. Thus, to evaluate the potential of groundwater contamination in urban areas, it is necessary to consider other factors such as groundwater withdrawal rate and well density per unit area with ratings and weights as well as the existing six DRASTIC factors.

  • PDF

Spatial Query Processing Based on Minimum Bounding in Wireless Sensor Networks

  • Yang, Sun-Ok;Kim, Sung-Suk
    • Journal of Information Processing Systems
    • /
    • v.5 no.4
    • /
    • pp.229-236
    • /
    • 2009
  • Sensors are deployed to gather physical, environmental data in sensor networks. Depending on scenarios, it is often assumed that it is difficult for batteries to be recharged or exchanged in sensors. Thus, sensors should be able to process users' queries in an energy-efficient manner. This paper proposes a spatial query processing scheme- Minimum Bounding Area Based Scheme. This scheme has a purpose to decrease the number of outgoing messages during query processing. To do that, each sensor has to maintain some partial information locally about the locations of descendent nodes. In the initial setup phase, the routing path is established. Each child node delivers to its parent node the location information including itself and all of its descendent nodes. A parent node has to maintain several minimum bounding boxes per child node. This scheme can reduce unnecessary message propagations for query processing. Finally, the experimental results show the effectiveness of the proposed scheme.

A numerical method for the limit analysis of masonry structures

  • Degl'Innocenti, Silvia;Padovani, Cristina
    • Structural Engineering and Mechanics
    • /
    • v.18 no.1
    • /
    • pp.1-20
    • /
    • 2004
  • The paper presents a numerical method for the limit analysis of structures made of a rigid no-tension material. Firstly, we formulate the constrained minimum problem resulting from the application of the kinematic theorem, which characterizes the collapse multiplier as the minimum of all kinematically admissible multipliers. Subsequently, by using the finite element method, we derive the corresponding discrete minimum problem in which the objective function is linear and the inequality constraints are linear as well as quadratic. The method is then applied to some examples for which the collapse multiplier and a collapse mechanism are explicitly known. Lastly, the solution to the minimum problem calculated via numerical codes for quadratic programming problems, is compared to the exact solution.