• Title/Summary/Keyword: minimal condition

Search Result 364, Processing Time 0.02 seconds

Class-E Power Amplifier with Minimal Standby Power for Wireless Power Transfer System

  • Kim, Bong-Chul;Lee, Byoung-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.250-255
    • /
    • 2018
  • This paper presents a method for minimizing standby power consumption in wireless power transfer (WPT) system via magnetic resonance coupling (MRC) that operates at 6.78 MHz. The proposed circuit controls the required capacitance according to operational condition in order to reduce standby power consumption. Based on an impedance characteristic of the class-E power amplifier, operational principles of the proposed circuit are analyzed. Moreover, to verify the effectiveness of the proposed class-E power amplifier, an 8 W prototype for WPT system is implemented. The measured input power of the proposed class-E power amplifier at standby condition is reduced from 5.81 W to 3.53 W.

Introduction of a Bacterial Hemoglobin Gene for Improving Bacterial Growth under Hypoxic Condition

  • Chung, Chung-Nam;Yoon, Suk-Ran;Jun, Woo-Jin;Shim, Sang-In;Park, In-Ho;Chung, Jin-Woong
    • Journal of agriculture & life science
    • /
    • v.43 no.6
    • /
    • pp.77-84
    • /
    • 2009
  • Using recombinant DNA technology, the vector system containing minimal fragment of a bacterial hemoglobin gene (vgb) was constructed. When this vector was inserted into Escherichia coli, the growth of the host was significantly improved in both viable cell counts and absorbance measurement, compared to that of the wild type strain. In addition, by minimizing the size of bacterial hemoglobin in the vector, the ability of vgb in growth improvement was augmented, due to the reduction of metabolic burden from the maintenance and replication of the plasmid. By using this system, it is expected that the growth of microorganisms can be improved even in the hypoxic condition.

A Numerical Method for a High-Speed Ship with a Transom Stern

  • Kyoung Jo-Hyun;Bai Kwang-June
    • Journal of Ship and Ocean Technology
    • /
    • v.8 no.3
    • /
    • pp.8-17
    • /
    • 2004
  • A numerical method is developed for computing the free surface flows around a transom stern of a ship at a high Froude number. At high speed, the flow may be detached from the flat transom stern. In the limit of the high Froude number, the problem becomes a planning problem. In the present study, we make the finite-element computations for a transom stern flows around a wedge-shaped floating ship. The numerical method is based on the Hamilton's principle. The problem is formulated as an initial value problem with nonlinear free surface conditions. In the numerical procedures, the domain was discretized into a set of finite elements and the numerical quadrature was used for the functional equation. The time integrations of the nonlinear free surface condition are made iteratively at each time step. A set of large algebraic equations is solved by GMRES(Generalized Minimal RESidual, Saad and Schultz 1986) method which is proven very efficient. The computed results are compared with previous numerical results obtained by others.

ANNIHILATING PROPERTY OF ZERO-DIVISORS

  • Jung, Da Woon;Lee, Chang Ik;Lee, Yang;Nam, Sang Bok;Ryu, Sung Ju;Sung, Hyo Jin;Yun, Sang Jo
    • Communications of the Korean Mathematical Society
    • /
    • v.36 no.1
    • /
    • pp.27-39
    • /
    • 2021
  • We discuss the condition that every nonzero right annihilator of an element contains a nonzero ideal, as a generalization of the insertion-of-factors-property. A ring with such condition is called right AP. We prove that a ring R is right AP if and only if Dn(R) is right AP for every n ≥ 2, where Dn(R) is the ring of n by n upper triangular matrices over R whose diagonals are equal. Properties of right AP rings are investigated in relation to nilradicals, prime factor rings and minimal order.

CONSTRUCTION OF TWO- OR THREE-WEIGHT BINARY LINEAR CODES FROM VASIL'EV CODES

  • Hyun, Jong Yoon;Kim, Jaeseon
    • Journal of the Korean Mathematical Society
    • /
    • v.58 no.1
    • /
    • pp.29-44
    • /
    • 2021
  • The set D of column vectors of a generator matrix of a linear code is called a defining set of the linear code. In this paper we consider the problem of constructing few-weight (mainly two- or three-weight) linear codes from defining sets. It can be easily seen that we obtain an one-weight code when we take a defining set to be the nonzero codewords of a linear code. Therefore we have to choose a defining set from a non-linear code to obtain two- or three-weight codes, and we face the problem that the constructed code contains many weights. To overcome this difficulty, we employ the linear codes of the following form: Let D be a subset of ��2n, and W (resp. V ) be a subspace of ��2 (resp. ��2n). We define the linear code ��D(W; V ) with defining set D and restricted to W, V by $${\mathcal{C}}_D(W;V )=\{(s+u{\cdot}x)_{x{\in}D^{\ast}}|s{\in}W,u{\in}V\}$$. We obtain two- or three-weight codes by taking D to be a Vasil'ev code of length n = 2m - 1(m ≥ 3) and a suitable choices of W. We do the same job for D being the complement of a Vasil'ev code. The constructed few-weight codes share some nice properties. Some of them are optimal in the sense that they attain either the Griesmer bound or the Grey-Rankin bound. Most of them are minimal codes which, in turn, have an application in secret sharing schemes. Finally we obtain an infinite family of minimal codes for which the sufficient condition of Ashikhmin and Barg does not hold.

Cardiac Transplantation; 1 Case Report (심장이식 1례보고)

  • 송명근
    • Journal of Chest Surgery
    • /
    • v.26 no.3
    • /
    • pp.224-227
    • /
    • 1993
  • We experienced one case of orthotopic cardiac transplantation in a patient with end stage dilated cardiomyopathy. This 50 year-old female recipient was suffered from NYHA functional class IV cardiac failure and dependent upon intravenous inotropic support for 2 months [recipient category 1]. Her preoperative condition was grave with left ventricular ejection fraction of 20% and estimated systolic pulmonary arterial pressure [from Doppler study] was 50mmHg. The brain-dead donor was 31 year-old male with head trauma. The body sizes [weight, height] of the donor/recipient were 70 Kg, 165 cm / 43 Kg, 160 cm and appropriately overmatched. Preoperatively, identical ABO/Rh blood group [A+] and nonreacting HLA crossmatching were confirmed. On November 11 1992 cardiac transplantation was performed without complication. Multiple organ procurement team and heart transplantation team were organized the operation schedule appropriately to minimize the ischemic time. The pump time was 126 minutes and aortic crossclamping time of recipient heart was 73 minutes and, as a result, total ischemic time of the transplanted heart was 75 minutes. Postoperatively, the vital signs were stable with minimal inotropic support. The immunosuppressive therapy was commenced from preoperatively and cyclosporine, azathioprine, and corticosteroid were used as a combination therapy as scheduled and monitored with blood drug concentration, WBC count, renal function and most importantly regular endomyocardial biopsy.Now, 5 months after transplantation, the patient is in NYHA functional class II with minimal cardiac drug support.

  • PDF

Difference in Premenstrual Syndrome by Physical Activity Level in High School Girls (여고생의 신체활동 정도에 따른 월경전증후군의 차이)

  • Nam, KeonHee;Lee, YoungHee
    • Journal of Korean Public Health Nursing
    • /
    • v.28 no.2
    • /
    • pp.320-332
    • /
    • 2014
  • Purpose: This study was conducted in order to examine premenstrual symptoms (PMS) according to physical activity of high school girls. Method: Data were collected from 323 high school girls using structured questionnaires, Menstrual Distress Questionnaire (MDQ) and International Physical Activity Questionnaire (IPAQ). The data were analyzed using descriptive statistics, t-test, and AVOVA. Results: The mean score of PMS was low (2.200.81). Among the subcategories, negative feeling (2.491.26) was the highest. Physical activity levels were coded as inactive, minimal activity and health enhancing physical activity, among which minimal activity (53.0%) was the highest. Significant differences in PMS were observed according to subjective health condition (F=10.83, p<.001), alcohol intake (t=-1.99, p=.048), caffeine intake (F=3.04, p=.029), dietary habit (F=4.78, p=.009), amount of menstruation (F=4.57, p=.011), discomfort in daily life (F=28.94, p<.001), degree of menstrual pain (F=41.23, p<.001), method of menstrual pain relief (F=4.29, p=.015), and family history (F=11.45, p<.001). Significant difference in PMS was observed according to the physical activity level (F=3.12, p=.046), and health enhancing physical activity (2.540.87) was the highest. Conclusion: These findings suggest that PMS intervention programs would be considered factors related to PMS. Conduct of further studies is recommended for evaluation of the relationship between physical activity and PMS.

Factors Affecting in Vitro Activity of LB20304, a New Flu-oroquinolone

  • Paek, Kyoung-Sook;Ahn, Mi-Jeong;Kim, Mu-Yong;Kim, In-Chull;Kwak, Jin-Hwan
    • Archives of Pharmacal Research
    • /
    • v.19 no.2
    • /
    • pp.143-147
    • /
    • 1996
  • LB20304 is a novel fluoroquinolone that exhibits a potent broad spectrum antibacterial activity against both gram-positve and gram-negative bacteria. The MICs (Minimal Inhibitory Concentration) of LB20304 were determined against both gram-positve and gram-negative bacteria under various conditions including several media, pHs, and inoculum concentrations. The in vitro activity of LB20304 was not significantly affected by the changes in testing conditions such as components of media and inoculum concentrations, but it was slightly reduced by acid condition. The MICs and MBCs (Minimal Bactericidal Concentration) of LB20304 against Staphylococcus aureus, Escherichia coli and Pseudomonas aeruginosa were hardly affected by the presence of 50 % human serum, mouse serum, guinea pig serum or horse serum, and the MBCs were equal to or at most four-times higher than the MiCs. The activities of LB20304 were decreased by the presence of high concentraion of $Mg^{++}$ or human urine (pH, 5.5) in the test media. The frequencies of mutants resistant to LB20304 were similar to or lower than those found in ciprofloxacin and sparfloxacin.

  • PDF

Parametric Study of a Fixed-blade Runner in an Ultra-low-head Gate Turbine

  • Mohamed Murshid Shamsuddeen;Duc Anh Nguyen;Jin-Hyuk Kim
    • New & Renewable Energy
    • /
    • v.20 no.1
    • /
    • pp.116-125
    • /
    • 2024
  • Ultra-low-head is an unexplored classification among the sites in which hydroelectric power can be produced. This is typically owing to the low power output and the economic value of the turbines available in this segment. A turbine capable of operating in an ultra-low-head condition without the need of a dam to produce electricity is developed in this study. A gate structure installed at a shallow water channel acting as a weir generates artificial head for the turbine mounted on the gate to produce power. The turbine and generator are designed to be compact and submersible for an efficient and silent operation. The gate angle is adjustable to operate the turbine at varying flow rates. The turbine is designed and tested using computational fluid dynamics tools prior to manufacturing and experimental studies. A parametric study of the runner blade parameters is conducted to obtain the most efficient blade design with minimal hydraulic losses. These parameters include the runner stagger and runner leading edge flow angles. The selected runner design showed improved hydraulic characteristics of the turbine to operate in an ultra-low-head site with minimal losses.

Experimental Study on DeNOx Characteristics of Urea-SCR System (Urea-SCR 시스템의 DeNOx 특성에 관한 실험적 연구)

  • Ham, Yun-Young;Lee, Seong-Ho;Jung, Hong-Seok;Shin, Dong-Hyun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.2
    • /
    • pp.180-186
    • /
    • 2009
  • To meet the NOx limit without a penalty of fuel consumption, urea SCR system is currently regarded as promising NOx reduction technology for diesel engines. SCR system has to achieve maximal NOx conversion in combination with minimal $NH_3$ slip. In this study, as a basic research to develop an algorithm for urea injection control, the characteristics of engine out NOx emission and behavior of NOx reduction during steady-state and transient conditions were investigated using 2L DI diesel engine. Test results show that on increasing the catalyst temperature the variations in the outlet NOx concentration are faster and maximal allowable $NH_3$ storage exponentially decreases. For change from a low to high engine load, it can be seen that a few seconds after load-step is required to reach full NOx conversion and the adsorbed amount of $NH_3$ at lower temperature desorb during the next temperature increase, causing $NH_3$ slip. Engine out NOx emission needs to be corrected because NOx emissions just after step load is lower than that of steay state condition.