• Title/Summary/Keyword: miniaturization

Search Result 806, Processing Time 0.022 seconds

Blood Pressure Estimation for Development of Wearable small Blood Pressure Monitor Fusion Algorithm Analysis (웨어러블 초소형 혈압계 개발을 위한 혈압 추정 융합 알고리즘 분석)

  • Kim, Seon-Chil;Kwon, Chan-Hoe;Park, You-rim
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.11
    • /
    • pp.209-215
    • /
    • 2019
  • The most important personal health care in digital health care is a very important issue mainly for chronic diseases. Therefore, it is important to develop a simple wearable device for real-time health management. Existing blood pressure estimation wearable devices use PPG characteristics to analyze PTT and propose blood pressure estimation algorithms. However, the influencing factors of the algorithm such as the reproducibility of PPG, whether to apply various PTTs, and variables generated from the physical differences of the measurers are actually very complex. Therefore, in this study, the correlation between PTT, SBP, and DBP was analyzed, and it was designed to use PPG sensors for device miniaturization. The blood pressure estimation algorithm took into account differences in PPG, heart rate, and personal variables.

Beam Shaping and Speckle Reduction in Laser Projection Display Systems Using a Vibrating Diffractive Optical Element

  • Liang, Chuanyang;Zhang, Wei;Wu, Zhihui;Rui, Dawei;Sui, Yongxin;Yang, Huaijiang
    • Current Optics and Photonics
    • /
    • v.1 no.1
    • /
    • pp.23-28
    • /
    • 2017
  • The laser has been regarded as the potential illumination source for the next generation of projectors. However, currently the major issues in applying the laser as an illumination source for projectors are beam shaping and laser speckle. We present a compact solution for both issues by using a vibrating diffractive optical element (DOE). The DOE is designed and fabricated, and it successfully transforms the circular Gaussian laser beam to a low speckle contrast uniform rectangular pattern. Under a vibration frequency of 150 Hz and amplitude of $200{\mu}m$, the speckle contrast value is reduced from 67.67% to 13.78%, and the ANSI uniformity is improved from 24.36% to 85.54%. The experimental results demonstrate the feasibility and potential of the proposed scheme, and the proposed method is a feasible approach to the miniaturization of laser projection display illumination systems.

Development of IR Thermal Camera Detector based on Smartphone Interlocking for Hidden Camera Crime Prevention (몰래카메라 범죄방지를 위한 스마트폰 연동 기반의 IR 열카메라 탐지기 개발)

  • Kang, Young-Gil;Cho, Pil-Gu;Kim, Young-Gon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.6
    • /
    • pp.1-8
    • /
    • 2021
  • The performance of hidden camera cameras is improving day by day due to miniaturization and advanced technology integration according to the speed of technological development of smartphones. As this external networking computing environment is advanced and diversified, exposure to hidden cameras in addition to general safety cameras is also increasing. On the other hand, the technology for detecting and preventing hidden cameras is not keeping up with the development and speed of these hidden cameras. Therefore, in this study, the heat of the hidden camera was detected using infrared thermal detection technology based on general image and thermal image synthesis technology, and the reflectance of each wavelength according to the difference in ambient temperature was analyzed to reduce the false positive rate.

Design and fabrication of Ka-band high power and high efficiency waveguide spatial combiner (Ka 대역 고출력 고효율 도파관 공간 결합기 설계 및 제작)

  • Kim, Hyo-Chul;Cho, Heung-Rae;Lee, Ju-Heun;Lee, Deok-Jae;An, Se-Hwan;Lee, Man-Hee;Joo, Ji-Han;Kim, Hong-Rak
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.5
    • /
    • pp.19-26
    • /
    • 2021
  • This report proposes a waveguide spatial combiner with high power low loss. The proposed spatial combiner implements high power by combining from the center of each port through a waveguide. In particular, we implement low loss using TE01 mode, which has the lowest transmission track loss among modes of circular waveguide, and miniaturization is achieved by applying a new mode conversion method. IIn addition, it was confirmed that it was suitable for high output by calculating the insulation breakdown voltage of the new mode conversion structure through E-field analysis. The final 8-way waveguide spatial combiner was designed and manufactured, and the insertion loss was less than 0.4dB and the combining efficiency was 97% or more, confirming that the electrical performance was very good compared to the planar combining method.

Design and Fabrication of a High-Power Pulsed TWTA for Millimeter-Wave(Ka-Band) Multi-Mode Seeker (밀리미터파(Ka 밴드) 복합모드 탐색기용 고출력 펄스형 진행파관 증폭기(TWTA) 설계 및 제작)

  • Song, Sung-Chan;Kim, Sun-Ki;Lee, Sung-Wook;Min, Seong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.4
    • /
    • pp.307-313
    • /
    • 2019
  • The traveling wave tube amplifier (TWTA), which can be applied to the Ka-band millimeter-wave multi-mode seeker, consists of an high voltage power supply(HVPS), a grid modulator, a command and control, and an RF assembly. We designed a power supply that generates a -17.9 kV high voltage by synchronizing the pulse repetition frequency(PRF) and power supply switching frequency(i.e. synchronization frequency), and a high-speed grid-switching modulator for RF pulse modulation. The TWTA, which is fabricated through miniaturization with a volume of 3.18 L, has high pulse switching characteristics of up to 18.5 ns. The maximum rise/fall time of the grid on/bias signal and peak power is more than 564.9 W. Moreover, an excellent spurious performance of -68.4 dBc or less was confirmed within the range of PRF and PRF/2.

Feasibility Study of Beta Detector for Small Leak Detection inside the Reactor Containment

  • Jang, JaeYeong;Schaarschmidt, Thomas;Kim, Yong Kyun
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.154-159
    • /
    • 2018
  • Background: To prevent small leakage accidents, a real-time and direct detection system for small leaks with a detection limit below that of existing systems, e.g. $0.5gpm{\cdot}hr^{-1}$, is required. In this study, a small-size beta detector, which can be installed inside the reactor containment (CT) building and detect small leaks directly, was suggested and its feasibility was evaluated using MCNPX simulation. Materials and Methods: A target nuclide was selected through analysis of radiation from radionuclides in the reactor coolant system (RCS) and the spectrum was obtained via a silicon detector simulated in MCNPX. A window was designed to reduce the background signal caused by other nuclides. The sensitivity of the detector was also estimated, and its shielding designed for installation inside the reactor CT. Results and Discussion: The beta and gamma spectrum of the silicon detector showed a negligible gamma signal but it also contained an undesired peak at 0.22 MeV due to other nuclides, not the $^{16}N$ target nuclide. Window to remove the peak was derived as 0.4 mm for beryllium. The sensitivity of silicon beta detector with a beryllium window of 1.7 mm thickness was derived as $5.172{\times}10^{-6}{\mu}Ci{\cdot}cc^{-1}$. In addition, the specification of the shielding was evaluated through simulations, and the results showed that the integrity of the silicon detector can be maintained with lead shielding of 3 cm (<15 kg). This is a very small amount compared to the specifications of the lead shielding (600 kg) required for installation of $^{16}N$ gamma detector in inside reactor CT, it was determined that beta detector would have a distinct advantage in terms of miniaturization. Conclusion: The feasibility of the beta detector was evaluated for installation inside the reactor CT to detect small leaks below $0.5gpm{\cdot}hr^{-1}$. In future, the design will be optimized on specific data.

VR Image Shooting Considering Post-Production based Raw Format (원규격 기반 후반작업을 고려한 실사 VR 영상 촬영)

  • Kim, Chulhyun
    • Journal of Broadcast Engineering
    • /
    • v.23 no.6
    • /
    • pp.866-875
    • /
    • 2018
  • With the popularity of VR content, actual image based VR 360-degree video production using various shooting devices has attracted attention in recent years. Requiring a lot of work, the existing VR content production was possible only at the level of the research institute, but the recent miniaturization of cameras has made the VR actual image shooting more common to the content creators. In this paper, we compare and study various VR contents distribute in today's context and analyze the strengths and weaknesses of robust actual image-based 360 video production in terms of cost. We are to point out the disadvantages that make it difficult for existing video shooting experts to use and suggest a solution for this. The experiment shooting proved that it can be operated more manually than action cam or integrated camera and 360-degree shooting on a raw format support camera is more suitable for film type post-production.

Analysis of Blood pressure influence factor Correction for Photoplethysmography Fusion Algorithm Calibration (광전용적맥파 융합 알고리즘 보정을 위한 혈압 영향인자 상관관계 분석)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.2
    • /
    • pp.67-73
    • /
    • 2019
  • The blood pressure measurement is calculated as a value corresponding to the pressure of the blood vessel using the pressure from the outside for a long time. Due to the recent miniaturization of measurement equipment and the ICT combination of personal healthcare systems, a system that enables continuous and real-time measurement of blood pressure with a sensor is required. In this study, blood pressure was measured using pulse transit time using Photoplethysmography. In this study, blood pressure was estimated by using systolic blood pressure. And it is possible to make measurement only with PPG itself, which can contribute to making a micro blood pressure measuring device. As a result, systolic blood pressure and PPG's S1-P and P-S2 were used to analyze the possibility of blood pressure estimation.

UWB/Bluetooth for a High Speed Wireless Communication Network Dual Band Microstrip Antenna Design (해상 고속 무선 통신망을 위한 UWB/Bluetooth용 이중대역 마이크로스트립 안테나 설계)

  • Oh, Mal-Geun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.7
    • /
    • pp.960-966
    • /
    • 2018
  • Communication antennas used at sea have been developed remarkably. However, the speed of this development is insufficient when compared with user demands. Therefore, we developed an antenna for UWB/Bluetooth that operates on 3 [GHz] and 5.72 [GHz] bands in order to use the high-speed communication network system which improved antenna miniaturization, gain and radiation patterns. To improve bandwidth, a microstrip patch antenna was selected and CST Microwave Studio 2014 program was used. Through the program, we calculated the slot width, length, transmission line width, etc. using a theoretical formula at each step. These figures were checked through simulation to see if they meet production standards. UWB for high-speed wireless communication for short-range communication at sea, Bluetooth for exchanging information at a short distance by connecting each device, and corresponding technology can be easily utilized.

Development of Energy Harvesting Technologies Platform for Self-Power Rechargeable Pacemaker Medical Device. (자가발전 심장박동기를 위한 에너지 수확 플랫폼 개발)

  • Park, Hyun-Moon;Lee, Jung-Chul;Kim, Byunng-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.3
    • /
    • pp.619-626
    • /
    • 2019
  • The advances of semiconductor and circuitry technology dovetailed with nano processing techniques have further enhanced micro-miniaturization, sensitivity, longevity and reliability in MID(Medical Implant Device). Nevertheless, one of the remaining challenges is whether power can sufficiently and continuously be supplied for the operation of the MID. Self-powered MID that harvest biomechanical energy from human motion, respiratory and muscle movement are part of a paradigm shift. In this paper, we developed a rechargeable pacemaker through self-power generation with the triboelectric nanogenerator. We demonstrate a fully implanted pacemaker based on an implantable triboelectric nanogenerator, which act as a storage as well as active movement on a large-animal(dog) scale. The self-power pacemaker harvested from animal motion is 2.47V, which is higher than the required pacemaker device sensing voltage(1.35V).