• Title/Summary/Keyword: miniature society

Search Result 571, Processing Time 0.025 seconds

The Effect of Delayed Compaction on Unconfined Compressive Strength of Soil-Cement Mixtures (지연다짐이 Soil-Cement의 압축강도에 미치는 영향)

  • 정일웅;김문기;도덕현
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.28 no.4
    • /
    • pp.66-76
    • /
    • 1986
  • This study was attempted to investigate the effects of delayed compaction on the unconfined compressive strengh and dry density of Soil-cement mixtures. Soil-cement construction is a time-consuming procedure. Time-delay is known as a detrimental factor to lower the quality of soil-cement layer. A laboratory test was performed using coarse and fine weathered granite soils. The soils were mixed with 7% cement at optimum moisture content and excess moisture content in part. Socondary additives such as lime, gypsum-plaster, flyash and sugar were tried to counteract the detri-mental effect of delayed compaction. The specimens were compacted by Harvard Miniature Compaction Apparatus at 0,1,2,4,6 hors after mixing. Two kinds of compactive efforts(9 kgf and 18 kgf tamper) were applied. The results were summarized as follows: 1.With the increase of time delay, the decrease rate of dry density of the specimen compacted by 9 kgf tamper was steeper than that of the specimen compacted by 18kgf tamper. In the same manner, soil-B had steeper decreasing rate of dry density than soil-A. 2.Based on the results of delayed compaction tests, the dry density and unconfined compressive sterngth were rapidly decreased in the early 2 hours delay, while those were slowly decreased during the time delay of 2 to 6 hours. 3.The dry density and unconfined compressive strength were increased by addition of 3% excess water to the optimum moisture content during the time delay of 2 to 6 hours. 4.Without time delay in compaction, the dry densities of soil-A were increased by adding secondary additives such as lime, gypsum-plaster, flyash and sugar, on the other hand, those of soil-B were decreased except for the case of sugar. 5.The use of secondary additives like lime, gypsum-plaster, flyash and sugar could reduce the decrease of unconfined compressive strength due to delayed compaction. Among them, lime was the most effective. 6.From the above mentioned results, several recommendations could be suggested in order to compensate for losses of unconfined compressive strenght and densit v due to delayed compaction. They are a) to use coarse-grained granite soil rather than fined-grained one, b) to add about 3% excess compaction moisture content, c) to increase compactive effort to a certain degree, and d) to use secondary additives like line gypsum-plaster, flyash, and sugar in proper quantity depending on the soil types.

  • PDF

Experimental Study on the Behavior Characteristics of Single Steel Pile in Sand Subjected to Lateral Loadings (사질토 지반에서 수평하중에 따른 단일강관말뚝의 거동특성에 관한 실험적 연구)

  • Kim, Daehyeon;Lee, Tae-Gwang;Kim, Sun-Hak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3548-3556
    • /
    • 2015
  • In order to fulfill the needs of reliable and economically feasible foundation, engineers should consider not only the working load that can endure extreme conditions but also apprehending precise behavior of continuous dynamic load while designing the foundation of offshore wind power generators. To actualize the foundation, a model pile was made in miniature. Also, calibration chamber was made and a 500mm height of sand-bed was made to perform "static lateral load experiment" and "repetitive loading experiment", total of two Lateral load tests. As a result, in Static Lateral load test, the bigger length/diameter of model pile led an increase in load displacement. However, when performing "Cyclic Lateral load test", the increase in number of under loading led the decrease in horizontal displacement from each repeated lateral load. While performing Static Lateral load test and repeated loading experiment, we could observe the decreasing in the rate of ultimate lateral load capacity increase of the pile. Also, it turned out that the higher relative density of the ground, the lower ultimate lateral load capacity by repeated horizontal loading.

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

Establishment of a Prediction Table of Parturition Day with Ultrasonography in Small Pet Dogs (소형 애완견에서 초음파 검사에 의한 분만일 예시표의 확립)

  • Oh, Ki-Seok;Kim, Bang-Sil;Park, Sang-Guk;Park, Chul-Ho;Kim, Jae-Hong;Mun, Byeong-Gwon;Kim, Hee-Su;Lee, Ju-Hwan;Park, In-Chul;Kim, Jong-Taek;Suh, Guk-Hyun;Son, Chang-Ho
    • Journal of Embryo Transfer
    • /
    • v.23 no.3
    • /
    • pp.155-160
    • /
    • 2008
  • Serial ultrasonographic examinations were performed to establish a prediction table of parturition date in pregnant Maltese, Yorkshire Terrier, Shih-tzu and Miniature Schnauzer bitches. The inner chorionic cavity diameter and fetal head diameter in 45 pregnant bitches were converted retrospectively based on the day of parturition. The data of inner chorionic cavity diameter obtained from Day-44 to Day-25 and fetal head diameter obtained from Day-25 to Day-1 were used to compile a equations of prediction of parturition date. The 70 pregnant bitches with unknown mating time were examined to assess an accuracy of the equations established in this study. And these results were applied to the prediction of parturition date and compared to actual parturition date. The accuracy for parturition date within 0, $\pm$1, and $\pm$2 days interval using the equations of prediction of parturition date were 64.3%, 22.8% and 12.8%, respectively. The overall accuracy of prediction table of parturition day based on the ICCD and HD was 100% accurate within $\pm$2 days. Therefore, the prediction table seems to be a useful tool of the prediction of parturition day in practice.

A study on basic characteristics of transmission lines employing various periodic strip structures on silicon substrate for a miniaturization of RF components (RF 소자의 소형화를 위해 실리콘 박막상에서 다양한 형태의 주기적 스트립 구조를 가지는 전송선로의 기본특성 연구)

  • Han, Sung-Jo;Jeong, Jang-Hyeon;Yun, Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.70-77
    • /
    • 2014
  • In this work, we studied basic characteristics of transmission lines employing various PSS (periodic strip structure) on silicon substrate for application to a miniaturization of RF components. According to the results, the transmission lines employing various PSS showed wavelength shorter than conventional coplanar waveguide due to their strong wave characteristics. Especially, with-contact structure was most effective for a miniaturization of RF component. Concretely, the size of the transmission line employing with-contact was only 4.39 % of the conventional coplanar waveguide, According to the bandwidth extraction result, the bandwidth of the transmission lines employing various PSS structures were wider than 384 GHz. Above results indicate that the transmission lines employing various PSS can be effectively used for application to a broadband and miniature RF component, and especially, with-contact is most effective for a miniaturization of RF components.

A Melon Fruit Grading Machine Using a Miniature VIS/NIR Spectrometer: 2. Design Factors for Optimal Interactance Measurement Setup

  • Suh, Sang-Ryong;Lee, Kyeong-Hwan;Yu, Seung-Hwa;Shin, Hwa-Sun;Yoo, Soo-Nam;Choi, Yong-Soo
    • Journal of Biosystems Engineering
    • /
    • v.37 no.3
    • /
    • pp.177-183
    • /
    • 2012
  • Purpose: In near infrared spectroscopy, interactance configuration of a light source and a spectrometer probe can provide more information regarding fruit internal attributes, compared to reflectance and transmittance configuration. However, there is no through study on the parameters of interactance measurement setup. The objective of this study was to investigate the effect of the parameters on the estimation of soluble solids content (SSC) and firmness of muskmelons. Methods: Melon samples were taken from greenhouses at three different harvesting seasons. The prediction models were developed at three distances of 2, 5, and 8 cm between the light source and the spectrometer probe, three measurement points of 2, 3, and 6 evenly distributed on each sample, and different number of fruit samples for calibration models. The performance of the models was compared. Results: In the test at the three distances, the best results were found at a 5 cm distance. The coefficient of determination ($R_{cv}{^2}$) values of the cross-validation were 0.717 (standard error of prediction, SEP=$1.16^{\circ}Brix$) and 0.504 (SEP=4.31 N) for the estimation of SSC and firmness, respectively. The minimum measurement point required to fully represent the spectral characteristics of each fruit sample was 3. The highest $R_{cv}{^2}$ values were 0.736 (SEP=$0.87^{\circ}Brix$) and 0.644 (SEP=4.16 N) for the estimation of SSC and firmness, respectively. The performance of the models began to be saturated when 60 fruit samples were used for developing calibration models. The highest $R_{cv}{^2}$ of 0.713 (SEP=$0.88^{\circ}Brix$) and 0.750 (SEP=3.30 N) for the estimation of SSC and firmness, respectively, were achieved. Conclusions: The performance of the prediction models was quite different according to the condition of interactance measurement setup. In designing a fruit grading machine with interactance configuration, the parameters for interactance measurement setup should be chosen carefully.

Evaluation of A Removal Process for the Residual Uranium from the Simulated Radwaste Solution by Solvent Extraction with TBP (TBP 용매추출에 의한 잔존 우라늄 제거공정 평가)

  • Lee, Eil-Hee;Kim, Kwang-Wook;Lim, Jae-Gwan;Kwon, Seon-Gil;Yoo, Jae-Hyung
    • Applied Chemistry for Engineering
    • /
    • v.9 no.2
    • /
    • pp.232-237
    • /
    • 1998
  • This study was carried out to find the optimal operating conditions for separation of residual uranium from the simulated radwaste solution containing 19 elements, and to evaluate the validity of the process. The selected process was based on the solvent extraction with TBP(tributyl phosphate). As an extractor, two miniature mixer-settlers with a total of 18 stages were used. Extraction yield of U, Np and Tc was about 99.2%. 32.1%, and 99.9%, respectively. The other elements were coextracted in the range of 1~4%. Extraction yield of U exceeded those of the previous work performed with batch system, which resulted in the low extractability of U (about 80%) according to the coexisting element such as Nd and Fe. It was due to the characteristics of multi-stage extractor. On the other hand, low extractability of Np was caused by various oxidation states in the nitric acid medium. In the case of Tc, its high extractability may be attributed to the complex formation with Zr and U, which is not well proved yet. All elements extracted with TBP were stripped into aqueous phase more than 99% by 0.01M $HNO_3$. From the results, this process has no problem with respect to in the same step was required, because Np was distributed in the raffinate and U product, respectively.

  • PDF

Establishment of Early Diagnosis and Surgical Operative Method in Puppies with Congenital Patellar Luxation (선천성 슬개골탈구를 지닌 자견의 조기 진단법 및 외과적 수술법 확립)

  • 정순욱;박수현
    • Journal of Veterinary Clinics
    • /
    • v.16 no.2
    • /
    • pp.309-320
    • /
    • 1999
  • Medial patellar luxation in dogs is one of the most common patellar problems presented to the veterinary practitioner. It is observed in toy and miniature breed and the majority of cases is a congenital form. Because of extensor mechanism's instability, it causes deformity and disorder in the growth of the affected limb when the luxation is left without treatment As lameness is not easily detectable in puppies, early diagnosis and correction are essential for therapy. Up to now, there has not been any reports refering to the diagnostic methods and the optimal age for correction in young dogs. Thirteen 45-90 days old puppies, have grade I and/or II medial patellar luxation. Only by palpation, all 13 dogs were diagnosed of patelar luxation. Skyline radiographic view was useful to interpret patellar morphology and depth of trochlear groove only above 60 days old. However, it was difficult to make definite diagnosis patellar luxation. The caudocranial and lateral radiographic view as well as ultrasonographic skyline view were not showed of patellar luxation. 2 puppies had unilateral patellar luxation and 11 puppies had bilateral patellar luxation which more serious on the left than on the right. Only 3 puppies among 11 puppies with bilateral patellar luxation were observed of lameness degree 1. Regardless of grade of patellar luxation and lameness, we performed trochlear chondroplasty using a U-shape sculpture blade to minimize cartilage injury, transposition of tibia tuberosity with No. 1 Supramid to align extensor mechanism and lateral imbrication. After surgery, we examined the operated animal daily for 10 days and on 15, 30 and 60 days after surgery respectively. After operation, pain and fever became normal on 7 days, swelling on 10 days, respectively. On 10 days after surgery, dogs showed normal standing position, and normal walking was observed in 15 days after surgery. In force plate analysis, the operated legs were normal weight bearing at 30 days after operation. After surgery, not only patellar luxation and clinical signs have been gradually reduced but also bone growth have become normal without showing growth physeal plate injury. The survival rate of puppies over 62 days old was 100%, while 42-45 days old 37.5%. The above results suggest that optimal age for surgical correction of congenital medial patellar luxation is recommended over 60 days old. In conclusion, combination of trochlear chondroplasty, transposition of tibia tuberosity, and lateral retinacular imbrication is appropriate for over 60 days old puppies to efficiently correct patellar luxation.

  • PDF

A Retrospective Study of Oral Tumors in Dogs: 44 cases ($2002{\sim}2007$) (개에서 발생한 구강종양 44례 ($2002{\im}2007$))

  • Park, Shin-Ae;Yi, Na-Young;Jeong, Man-Bok;Kim, Won-Tae;Kim, Se-Eun;Park, Young-Woo;You, Mi-Hyeon;Choi, Min-Cheol;Yoon, Jung-Hee;Kim, Dae-Yong;Seo, Kang-Moon
    • Journal of Veterinary Clinics
    • /
    • v.26 no.1
    • /
    • pp.36-40
    • /
    • 2009
  • The purpose of this study was to determine the incidence and therapeutic outcomes of canine oral tumors in Korea. Medical records of dogs presented with oral tumor at the Veterinary Medical Teaching Hospital of Seoul National University from 2002 to 2007 were reviewed. The predominant breeds were Yorkshire terrier (n=14), miniature poodle (n=7), Shih Tzu (n=6), and maltese (n=4), in order. The mean age at onset was $10.0{\pm}3.8$ years. The most common tumor types included fibrous epulis (n=13), malignant melanoma (n=12), acanthomatous epulis (n=4), and squamous cell carcinoma (n=3). Surgical removal was performed in 29 cases; simple excision in 18 cases, partial mandibulectomy in 8 cases, and partial maxillectomy in 3 dogs. Outcomes of surgery were various according to the tumor types. Prognosis of dogs with fibrous epulis and acanthomatous epulis was good and that of dogs with malignant melanoma was poor.

Prevalence of dog erythrocyte antigen 1, determined via immunochromatography, in domestic dogs in Korea (면역 크로마토그래피법을 이용한 국내 반려견의 Dog erythrocyte antigen 1 분포도 조사 연구)

  • Kim, Eunju;Choe, Changyong;Yoo, Jae Gyu;Oh, Sang-Ik;Jung, Younghun;Cho, Ara;Kim, Suhee;Do, Yoon Jung
    • Korean Journal of Veterinary Research
    • /
    • v.58 no.2
    • /
    • pp.81-85
    • /
    • 2018
  • Blood group determination in dogs is an important factor in transfusion medicine to minimize immediate or delayed adverse reactions after red blood cells transfusion in small animal clinics. Dog erythrocyte antigen (DEA) 1 is the most important blood type due to its high degree of antigenicity causing acute transfusion adverse reactions. The aim of this study was to investigate the prevalence of DEA 1 in various dog breeds in Korea. As a result of testing 592 blood samples from more than 35 dog breeds, DEA 1 blood typing for each breed showed that 57.8% of Malteses, 63.3% of Poodles, 76.2% of Mastiff-like dogs, 72.5% of Pomeranians, 47.7% of Shih Tzus, 70.3% of mixed breeds, 60.0% of Yorkshire Terriers, and 71.4% of Beagles were DEA 1-positive. Miniature Schnauzers and Jindo breeds had a significantly high prevalence (100%) of DEA 1-positive dogs compared to that in other small breed dogs. This is the first report of immunochromatography-detected DEA 1 prevalence in various domestic dog breeds. Although additional studies need clarifying the potential blood transfusion risks in domestic breed dogs with DEA 1, the results of this study may be useful when selecting a blood donor.