• Title/Summary/Keyword: mini implant

Search Result 117, Processing Time 0.019 seconds

Association Between Dental Implants and Cognitive Function in Community-dwelling Older Adults in Korea

  • Ki, Seungkook;Yun, Jihye;Kim, Jinhee;Lee, Yunhwan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.52 no.5
    • /
    • pp.333-343
    • /
    • 2019
  • Objectives: This study aimed to evaluate the association between dental implants and cognitive function in community-dwelling older adults. Methods: Data were collected from the baseline survey (2016-2017) of the Korean Frailty and Aging Cohort Study. The study sample comprised 1115 community-dwelling people aged 70 years to 84 years who had 0-19 natural teeth. Dental implants and natural teeth were identified by panoramic radiography, while the cognitive function was assessed by the Korean version of the Mini-Mental State Examination (MMSE-KC). The association between dental implants and cognitive function was analyzed by multiple linear regression. Sensitivity analysis was performed to test for potential bias. Results: The mean number of natural teeth in the study population was 9.50 (standard deviation [SD], 6.42), and the mean MMSE-KC score was 24.93 (SD, 3.55). In the simple univariate analysis, tooth replacement, age, sex, smoking status, alcohol consumption, body mass index, osteoporosis, number of natural teeth, periodontitis, chewing discomfort, tooth-brushing frequency, education level, monthly household income, participation in economic activity, living alone, and marital status had a significant impact on the association. After adjusting for confounders, the association between dental implants and cognitive function remained significant (B, 0.85; standard error, 0.40; p<0.05). Age, body mass index, periodontitis, tooth-brushing frequency, and education level were also significantly associated with cognitive function. The results of the sensitivity analyses were consistent with those of the primary analysis. Conclusions: Dental implants were associated with cognitive function in older adults living in the community. Dental implants as tooth replacements may play a role in preserving cognitive function.

Which anchorage device is the best during retraction of anterior teeth? An overview of systematic reviews

  • Yassir, Yassir A.;Nabbat, Sarah A.;McIntyre, Grant T.;Bearn, David R.
    • The korean journal of orthodontics
    • /
    • v.52 no.3
    • /
    • pp.220-235
    • /
    • 2022
  • Objective: To evaluate the available evidence regarding the clinical effectiveness of different types of anchorage devices. Methods: A comprehensive literature search of different electronic databases was conducted for systematic reviews investigating different anchorage methods published up to April 15, 2021. Any ongoing systematic reviews were searched using PROSPERO, and a grey literature search was undertaken using Google Scholar and OpenGrey. No language restriction was applied. Screening, quality assessment, and data extraction were performed independently by two authors. Information was categorized and narratively synthesized for the key findings from moderate- and high-quality reviews. Results: Fourteen systematic reviews were included (11 were of moderate/high quality). Skeletal anchorage with miniscrews was associated with less anchorage loss (and sometimes with anchorage gain). Similarly, skeletal anchorage was more effective in retracting anterior teeth and intruding incisors and molars, resulting in minor vertical skeletal changes and improvements in the soft tissue profile. However, insufficient evidence was obtained for the preference of any anchorage method in terms of the duration of treatment, number of appointments, quality of treatment, patient perception, or adverse effects. The effectiveness of skeletal anchorage can be enhanced when: directly loaded, used in the mandible rather than the maxilla, used buccally rather than palatally, using dual rather than single miniscrews, used for en-masse retraction, and in adults. Conclusions: The level of evidence regarding anchorage effectiveness is moderate. Nevertheless, compared to conventional anchorage, skeletal anchorage can be used with more anchorage preservation. Further high-quality randomized clinical trials are required to confirm these findings.

Complications reported with the use of orthodontic miniscrews: A systematic review

  • Giudice, Antonino Lo;Rustico, Lorenzo;Longo, Miriam;Oteri, Giacomo;Papadopoulos, Moschos A.;Nucera, Riccardo
    • The korean journal of orthodontics
    • /
    • v.51 no.3
    • /
    • pp.199-216
    • /
    • 2021
  • Objective: The aim of this systematic review was to evaluate the complications and side effects associated with the clinical use of orthodontic miniscrews by systematically reviewing the best available evidence. Methods: A survey of articles published up to March 2020 investigating the complications associated with miniscrew insertion, in both the maxilla and mandible, was performed using 7 electronic databases. Clinical studies, case reports, and case series reporting complications associated with the use of orthodontic miniscrew implants were included. Two authors independently performed study selection, data extraction, and risk-of-bias assessment. Results: The database survey yielded 24 articles. The risk-of-bias assessment revealed low methodological quality for the included studies. The most frequent adverse event reported was root injury with an associated periradicular lesion, vitality loss, pink discoloration of the tooth, and transitory loss of pulp sensitivity. Chronic inflammation of the soft tissue surrounding the miniscrew with mucosal overgrowth was also reported. The other adverse events reported were lesion of the buccal mucosa at the insertion site, soft-tissue necrosis, and perforation of the floor of the nasal cavity and maxillary sinus. Adverse events were also reported after miniscrew removal and included secondary bleeding, miniscrew fracture, scars, and exostosis. Conclusions: These findings highlight the need for clinicians to preliminarily assess generic and specific insertion site complications and side effects.

Effect and stability of miniscrew-assisted rapid palatal expansion: A systematic review and meta-analysis

  • Huang, Xinyi;Han, Yu;Yang, Shuangyan
    • The korean journal of orthodontics
    • /
    • v.52 no.5
    • /
    • pp.334-344
    • /
    • 2022
  • Objective: This study aimed to systematically analyze the effect and stability of miniscrew-assisted rapid palatal expansion (MARPE) to provide a reference for the clinical treatment of patients with maxillary transverse deficiency (MTD). Methods: We searched PubMed, Science Direct, Web of Science, Embase, Cochrane Library, CNKI, and Wanfang Database for relevant studies published before February 18, 2021 and selected them according to the eligibility criteria. The Cochrane Handbook for Systematic Reviews (version 5.1.0) criteria were used for the quality assessment of randomized controlled trials, while the scoring protocol of the methodological index for non-randomized studies was used for non-randomized controlled trials. Statistical analysis was performed using the RevMan5.3 software. Results: All the included studies showed a relatively high success rate of expansion. The changes in both the intermolar and alveolar widths after MARPE were statistically significant. MARPE exhibited greater skeletal expansion effects than did conventional RPE. The midpalatal suture was opened in parallel after MARPE. A small amount of relapse was observed 1 year after expansion. MARPE caused tooth inclination and a decrease in alveolar height, but it was less significant than in conventional RPE. Conclusions: MARPE may be an effective treatment modality for patients with MTD. It causes great transverse skeletal expansion in late adolescence. In comparison to conventional RPE, MARPE has lower detrimental periodontal effects and has certain clinical advantages.

Dentoalveolar effects of open-bite correction with the dual action vertical intra-arch technique: A finite element analysis

  • Sergio Estelita Barros;Kelly Chiqueto;Franciele Alberton;Katherine Jaramillo Cevallos;Juliana Faria;Bianca Heck;Leonardo Machado;Pedro Noritomi
    • The korean journal of orthodontics
    • /
    • v.54 no.5
    • /
    • pp.316-324
    • /
    • 2024
  • Objective: To evaluate tooth displacement and periodontal stress generated by the dual action vertical intra-arch technique (DAVIT) for open-bite correction using three-dimensional finite element analysis. Methods: A three-dimensional model of the maxilla was created by modeling the cortical bone, cancellous bone, periodontal ligament, and teeth from the second molar to the central incisor of a hemiarch. All orthodontic devices were designed using specific software to reproduce their morpho-dimensional characteristics, and their physical properties were determined using Young's modulus and Poisson's coefficient of each material. A linear static simulation was performed to analyze the tooth displacements (mm) and maximum stresses (Mpa) induced in the periodontal ligament by the posterior intrusion and anterior extrusion forces generated by the DAVIT. Results: The first and second molars showed the greatest intrusion, whereas the canines and lateral incisors showed the greatest extrusion displacement. A neutral zone of displacement corresponding to the fulcrum of occlusal plane rotation was observed in the premolar region. Buccal tipping of the molars and lingual tipping of the anterior teeth occurred with intrusion and extrusion, respectively. Posterior intrusion generated compressive stress at the apex of the buccal roots and furcation of the molars, while anterior extrusion generated tensile stress at the apex and apical third of the palatal root surface of the incisors and canines. Conclusions: DAVIT mechanics produced a set of beneficial effects for open-bite correction, including molar intrusion, extrusion and palatal tipping of the anterior teeth, and occlusal plane rotation with posterior teeth uprighting.

Influence of immediate loading on the removal torque value of mini-screws (교정력의 즉시 부하가 미니스크류의 제거 회전력에 미치는 영향의 평가)

  • Sun, Seung-Bum;Kang, Yoon-Goo;Kim, Seung-Hun;Mo, Sung-Seo;Kook, Yoon-Ah
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.400-406
    • /
    • 2007
  • The purpose of this experimental study was to evaluate the effect of immediate orthodontic loading on the stability at the bone-implant interface of titanium miniscrews in a rabbit model. Methods: Forty titanium miniscrews (1.6 mm diameter, 8 mm length) were inserted in the tibiae of 10 rabbits. Twenty test group miniscrews were subjected to continuous orthodontic forces of 200g immediately after implantation for a period of 6 weeks. The remaining 20 control group miniscrews were left unloaded for the same follow-up interval. Removal torque values were recorded using a digital torque gauge. An independent t-test was performed. Results: All the miniscrews were stable, and exhibited no mobility or displacement throughout the experimental period. Histologically, miniscrews were well-integrated into bone. No statistically significant differences in removal torque data were found between the loaded test and the unloaded control groups. Conclusions: These findings suggest that titanium miniscrews can be used as anchoring units for orthodontic tooth movement immediately after insertion.

Comparison of palatal bone thickness between 3D model and lateral cephalometric radiograph (성인 구개부 측모두부계측방사선 사진과 3D model의 골두께 비교)

  • Jang, Min-Guk;Lee, Jin-Woo;Cha, Kyung-Suk;Chung, Dong-Hwa;Lee, Sang-Min
    • The korean journal of orthodontics
    • /
    • v.41 no.5
    • /
    • pp.312-323
    • /
    • 2011
  • Objective: This study compared the bone thickness of the palate between lateral cephalogram and 3D model measurements. Methods: The subjects consisted of 30 adults (15 men,15 women) with a normal skeletal pattern and occlusion. The CT images were transformed to a 3D model, and were compared with the cephalometric image. Descriptive statistics for each variable were calculated. Results: In the 3D CT model, the mid-palatal area was the thickest part. It became thinner as the palate tapered laterally. In the male group, the thinnest portion was positioned 6 mm away from the mid-palate, while in the female group the thinnest portion was 8mm away from the mid-palate. Correlation analysis between the lateral cephalometric and 3D CT model revealed a significant correlation except in the mid palatal area and the area 2 mm lateral to the mid-palate in men, whereas there was a significant relationship in every area in the women. In both men and women, the highest correlation appeared in the area 8 mm lateral to the mid palate. Conclusions: Using regression analysis, an actual prediction of the bone thickness between the measured bone thickness of the lateral cephalometric radiograph and 3D model was made. This will provide useful information for mini-implant length selection when inserting into the palate.