• Title/Summary/Keyword: mini implant

Search Result 117, Processing Time 0.028 seconds

Effectiveness of Mini-Implant for the Reduction of Mandibular Fracture

  • Kim, Nam-Ho;Heo, Jeong-Uk;Park, Jun-Sub
    • Journal of Korean Dental Science
    • /
    • v.6 no.1
    • /
    • pp.4-12
    • /
    • 2013
  • Purpose: This study sought to verify the usefulness of mini-implant and surgical steel wire in the treatment of mandibular fracture through the objective identifi cation of the change of bone structure and bone density before and after reduction by evaluating radiological change through fractal analysis when mandibular fracture is treated using mini-implant and surgical wire. Materials and Methods: This study looked at 45 patients (males: 38, female: 7) diagnosed with mandibular fracture in the oral and maxillofacial surgery division of Chung-Ang University Dental Hospital and who received open reduction and intra-osseous fi xation. Result: The average fracture dimension values were higher for the group of the patients who had mini-implants and surgical wire treatment. Conclusion: Based on the results of the study on the usefulness of the reduction technique using mini-implant and surgical steel wire in the treatment of mandibular fracture through the fractal analysis method, the reduction technique using mini-implant and surgical steel wire is regarded as an effective method of minimizing the gap between mandibular fracture fragments.

Geometrical design characteristics of orthodontic mini-implants predicting maximum insertion torque

  • Katic, Visnja;Kamenar, Ervin;Blazevic, David;Spalj, Stjepan
    • The korean journal of orthodontics
    • /
    • v.44 no.4
    • /
    • pp.177-183
    • /
    • 2014
  • Objective: To determine the unique contribution of geometrical design characteristics of orthodontic mini-implants on maximum insertion torque while controlling for the influence of cortical bone thickness. Methods: Total number of 100 cylindrical orthodontic mini-implants was used. Geometrical design characteristics of ten specimens of ten types of cylindrical self-drilling orthodontic mini-implants (Ortho Easy$^{(R)}$, Aarhus, and Dual Top$^{TM}$) with diameters ranging from 1.4 to 2.0 mm and lengths of 6 and 8 mm were measured. Maximum insertion torque was recorded during manual insertion of mini-implants into bone samples. Cortical bone thickness was measured. Retrieved data were analyzed in a multiple regression model. Results: Significant predictors for higher maximum insertion torque included larger outer diameter of implant, higher lead angle of thread, and thicker cortical bone, and their unique contribution to maximum insertion torque was 12.3%, 10.7%, and 24.7%, respectively. Conclusions: The maximum insertion torque values are best controlled by choosing an implant diameter and lead angle according to the assessed thickness of cortical bone.

Surgical orthodontic treatment of skeletal Class III malocclusion using mini-implant: correction of horizontal and vertical dental compensation (Mini-implant를 이용한 III급 부정교합의 수술교정치료: 수평, 수직적 치성 보상의 조절)

  • Im, Dong-Hyuk;Park, Hyun-Jung;Park, Jae-Woo;Kim, Jeong-Il;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.36 no.5
    • /
    • pp.388-396
    • /
    • 2006
  • Treatment of skeletal Class III malocclusion with mini-implant anchorage is discussed in relation to vertical control of the maxillary posterior dentoalveolar region and horizontal control of mandibular anterior teeth. A midpalatal mini-implant provided anchorage for intruding the maxillary posterior teeth. Mandibular mini-Implant implants were used to bring about labioversion of mandibular anterior teeth. After mandibular setback surgery, improvement of the facial profile was obtained both horizontally and vertically, Total treatment time was 11 months. Stable occlusion was maintained after 18 months of retention, The effectiveness and efficacy of mini-implants for the treatment of skeletal Class III malocclusion are also discussed.

Film Image Transfer System (FITS): An Efficient Method for Proper Positioning of Orthodontic Mini-implants

  • Go, Taek-Su;Kim, Seong-Hun;Nelson, Gerald
    • Journal of Korean Dental Science
    • /
    • v.4 no.1
    • /
    • pp.20-25
    • /
    • 2011
  • Purpose: To describe the newly developed Film image transfer system (FITS) for proper positioning of the orthodontic mini-implant in the narrow interdental space and considerations for better application. Materials and Methods: A patient who was planning to have orthodontic mini-implant treatment on the posterior maxilla was recruited to assess the feasibility of FITS. Dental radiographic film and bite record was taken. And then the film image was transferred on the photographic emulsion coated model using transfer light through film projector (enlarger). After exposing the photo emulsion coating on the model, the image was developed with a working solution for a paper developer and fixed. The surgical guide for the mini-implant was fabricated from the transported FITS data. Results: The completed surgical guide was easily placed intraorally, and allowed a simple and rapid placement of the mini-implant. The site of the implant placement was accurate as planned position. Conclusion: In the reported case, The FITS technique represents an effort to minimize risk to the patient and produce consistently good results based upon accurate information about the anatomy of the implant site.

Diagnostic efficacy of a modified low-dose acquisition protocol for the preoperative evaluation of mini-implant sites

  • Tadinada, Aditya;Marczak, Alana;Yadav, Sumit
    • Imaging Science in Dentistry
    • /
    • v.47 no.3
    • /
    • pp.141-147
    • /
    • 2017
  • Purpose: The objective of this study was to compare the outcomes of surgical mini-implant placement when potential mini-implant sites were scanned using a lower-dose $180^{\circ}$ acquisition protocol versus a conventional $360^{\circ}$ acquisition protocol. Materials and Methods: Ten dentate human skulls were used to provide sites for potential mini-implant placement. The sites were randomly divided into 2 groups: $360^{\circ}$ and $180^{\circ}$ cone-beam computed tomography (CBCT) acquisition protocols. A small-volume $180^{\circ}$ CBCT scan and a $360^{\circ}$ CBCT scan of each site were acquired using a Morita Accuitomo-170 CBCT machine and then a mini-implant was placed. A follow-up $360^{\circ}$ CBCT scan was done as a gold standard to evaluate the location of the mini-implant and root perforation. Two raters evaluated the scans. Results: Ninety-eight percent of the mini-implants placed did not perforate any root structure. Two percent of the sites had an appearance suggestive of perforation. On a Likert scale, both raters agreed that their subjective evaluation of the diagnostic quality of the protocols, ability to make and read measurements of the sites, and preferences for the specified diagnostic task were comparable. The Cohen kappa showed high inter-rater and intrarater agreement. Conclusion: In this ex vivo study, we found that the $180^{\circ}$ rotational acquisition was as effective as the conventional $360^{\circ}$ rotational acquisition for the preoperative evaluation of potential mini-implant sites.

Multicentric retrospective clinical study on the clinical application of mini implant system (미니 임플란트 시스템의 적용에 대한 다기관 후향적 임상연구)

  • Kim, Young-Kyun;Yeo, In-Sung;Yi, Yang-Jin;Kim, Un-Kyu;Moon, Kyung-Nam;Jeon, Seung-Joon;Cho, Yong-Seok;Yun, Pil-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.4
    • /
    • pp.325-330
    • /
    • 2010
  • Introduction: Mini-implant system is applicable to areas of narrow space and area requiring temporary loading support. The purpose of this study was to evaluate the clinical outcome of a mini-implant system as well as the application of mini-implant system in the dental clinical field. Materials and Methods: The patients who had been operated from Jan 2007 to Dec 2007 in the four dental facility including Seoul National University Bundang Hospital were enrolled. To evaluate the factors associated with the clinical outcome, the patients were classified according to gender, age, area of surgery, type of implant, diameter and length of the implant, and the purpose of the mini-implant system application. Results: From 147 implants, only three implants failed, one of them was for temporary loading. There were no serious surgical or prosthetic complications in this study. Conclusion: An analysis of the preliminary data revealed a satisfactory clinical outcome. However, more long-term evaluation of narrow ridge type as well as the patient’s satisfaction on the use of a provisional type mini-implant system is needed.

Contact non-linear finite element model analysis of initial stability of mini implant (접촉 유한요소모델을 이용한 미니 임플란트의 초기 응력분포 연구)

  • Yoon, Hyun-Joo;Jung, Ui-Won;Lee, Jong-Suk;Kim, Chang-Sung;Kim, Jung-Moon;Cho, Kyoo-Sung;Kim, Chong-Kwan;Choi, Sung-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.681-690
    • /
    • 2007
  • Mini implants had been used provisionally for the healing period of implants in the beginning. But it becomes used for the on-going purpose, because it is simple to use, economic and especially suitable for the overdenture. But there is few studies about the stability of mini implants, that is most important factor for the on-going purpose, and particularly the implant parameters affecting the initial stability. The purpose of this study was to evaluate the stress and the strain distribution pattern of immediate-loaded screw type orthodontic mini-implant and the parameters affecting the initial stability of immediate-loaded mini-implant. Two dimensional finite element models were made and contact non-linear finite element analysis was performed. The magnitude and distribution of Von Mises stresses were evaluated. The obtained results were as follows: 1. The stress was concentrated on the thread tip of an implant in the cortical bone. 2. The direction of load is the most important factor for the stress distribution in cortical bone. 3. The diameter of an implant is the most important factor for the stress distribution in the trabecular bone. In conclusion, if the horizontal load vector is successfully controlled, mini-implants, which diameter is under 3mm, can be used for the on-going purpose.

Interdisciplinary treatment of Class III malocclusion using mini-implant: problem-oriented orthodontic treatment (Mini-implant를 이용한 III급 부정교합 환자의 협진 치료: 문제중심의 교정치료)

  • Im, Dong-Hyuk;Kim, Young-Shin;Cho, Min-Ah;Kim, Ki-Sung;Yang, Sung-Eun
    • The korean journal of orthodontics
    • /
    • v.37 no.4
    • /
    • pp.305-314
    • /
    • 2007
  • Interdisciplinary treatment of Class III malocclusion with congenital missing of unilateral maxillary canine and anterior crossbite is discussed focusing on a problem-oriented treatment planning, treatment progress, and treatment result. Maxillary mini-implant provided anchorage for distalization of the maxillary right porsterior dentition. Mandibular mini-implants were used to distalize the whole mandibular dentition. Total treatment time was 17 months to achieve a successful treatment goal. Stable occlusion was maintained after 12 months of retention.

Mini-implant with additional retentive structure by using digital method (부가적인 유지구조를 가진 미니 임플란트의 디지털 수복 증례)

  • Hwang, Su-Hyun;Bae, Eun-Bin;Cho, Won-Tak;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.119-126
    • /
    • 2022
  • Mini-implant has been reported as an alternative method to conventional diameter implants in the treatment of mandibular anterior region with narrow ridge. However, one-piece type mini-implant showed biological and technical complications, such as peri-implantitis by residual cement and prosthetic detachment. Recently, one-piece type mini-implant with additional retentive structure has been introduced to increase the retention and stability of the mini-implant. The mini-implant is based on spreading the upper retentive structure with a spreader and connected it with the inner surface of the zirconia prosthesis. In two cases, we tried to reduce these complications through the mini-implant on the narrow mandibular anterior region, and it was possible to reduce the overall treatment period through a digital system. In this case report, restoration using the digital mini-implant system showed improvement of patient satisfaction on the aspect of function and esthetic in the narrow mandibular anterior region.

MINI ONGOING IMPLANT TO REPLACE ANTERIOR SINGLE MISSING TOOTH WITH LIMITED SPACE: A CLINICAL REPORT

  • Kim, Ji-Won;Bae, Hanna Eun-Kyong;Hwang, Sun-Hong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.331-337
    • /
    • 2005
  • For a missing teeth, orthodontic treatment may be a better choice of treatment in comparison to a conventional prosthetic replacement such as FPD, resin bonded prosthesis in view of aesthetics, periodontal health and function. Occasionally after an orthodontic treatment, an insufficient space may occur. The mini-implant could be an alternative in situations of narrow ridge dimension, where conventional root form implant could be compromised. The aim of this clinical report is to describe how a space that could not be restored with a traditional root form endosteal implant was managed and to present a technique to achieve optimal anterior esthetics in single implant restoration.