• 제목/요약/키워드: mini cone

검색결과 28건 처리시간 0.024초

Applicability of Mini-Cone Penetration Test Used in a Soil Box

  • Sugeun Jeong;Minseo Moon;Daehyeon Kim
    • 한국지반신소재학회논문집
    • /
    • 제22권4호
    • /
    • pp.83-92
    • /
    • 2023
  • In this study, we conducted verification of key influencing factors during cone penetration testing using the developed Mini Cone Penetration Tester (Mini-CPT), and compared the experimental results with empirical formulas to validate the equipment. The Mini-CPT was designed to measure cone penetration resistance through a Strain Gauge, and the resistance values were calibrated using a Load Cell. Moreover, the influencing factors were verified using a model ground constituted in a soil box. The primary influencing factors examined were the boundary effect of the soil box, the distance between cone penetration points, and the cone penetration speed. For the verification of these factors, the experiment was conducted with the model ground having a relative density of 63.76% in the soil box. It was observed that the sidewall effect was considerably significant, and the cone penetration resistance measured at subsequent penetration points was higher due to the influence between penetration points. However, within the speed range considered, the effect of penetration speed was almost negligible. The measured cone penetration resistance was compared with predicted values obtained from literature research, and the results were found to be similar. It is anticipated that using the developed Mini-CPT for constructing model grounds in the laboratory will lead to more accurate geotechnical property data.

Characterization of railway substructure using a hybrid cone penetrometer

  • Byun, Yong-Hoon;Hong, Won-Taek;Lee, Jong-Sub
    • Smart Structures and Systems
    • /
    • 제15권4호
    • /
    • pp.1085-1101
    • /
    • 2015
  • Changes in substructure conditions, such as ballast fouling and subgrade settlement may cause the railway quality deterioration, including the differential geometry of the rails. The objective of this study is to develop and apply a hybrid cone penetrometer (HCP) to characterize the railway substructure. The HCP consists of an outer rod and an inner mini cone, which can dynamically and statically penetrate the ballast and the subgrade, respectively. An accelerometer and four strain gauges are installed at the head of the outer rod and four strain gauges are attached at the tip of the inner mini cone. In the ballast, the outer rod provides a dynamic cone penetration index (DCPI) and the corrected DCPI (CDCPI) with the energy transferred into the rod head. Then, the inner mini cone is pushed to estimate the strength of the subgrade from the cone tip resistance. Laboratory application tests are performed on the specimen, which is prepared with gravel and sandy soil. In addition, the HCP is applied in the field and compared with the standard dynamic cone penetration test. The results from the laboratory and the field tests show that the cone tip resistance is inversely proportional to the CDCPI. Furthermore, in the subgrade, the HCP produces a high-resolution profile of the cone tip resistance and a profile of the CDCPI in the ballast. This study suggests that the dynamic and static penetration tests using the HCP may be useful for characterizing the railway substructure.

소형 콘의 온도보상 기법 연구 (Study of Temperature Compensation method in Mini-Cones)

  • 윤형구;정순혁;조세현;이종섭
    • 대한토목학회논문집
    • /
    • 제31권1C호
    • /
    • pp.29-38
    • /
    • 2011
  • 소형 콘은 해상도가 뛰어나 국부영역의 탐지를 위하여 다양하게 활용되고있다. 소형 콘은 변형률계 부착 면적이 부족하여 half-bridge 형태로 회로를 구성하고 있으며, 이는 주변온도 변화에 의하여 민감하게 반응하는 것으로 알려져있다. 본 논문의 목적은 이러한 온도영향을 해소하기 위하여 소형 콘의 온도보상 기법에 관한 연구를 수행하는 것이다. 본 연구를 수행하기 위하여 직경과 길이가 각각 15mm 그리고 56mm인 소형 콘을 개발하였다. 로드셀은 온도변화만을 반영할 수 있는 공간을 확보하기 위하여 후면으로 54mm 연장하여 제작되었다. 온도보상회로는 스트레인 게이지를 선단저항 부분, 주면마찰 부분 그리고 연장한 로드셀에 부착하여 소형 콘 내에서 휘트스톤 브리지(Wheatstone bridge) 회로를 구성하였다. 소형 콘의 일반적 회로구성인 half-bridge도 내부에 함께 구성하여 상호간의 결과값을 비교 및 고찰하였다. 여름과 겨울의 계절적인 온도변화에 따라 측정값의 오차를 검증하기 위하여 계절적 온도 변화 실험을 수행하였다. 또한 지반다짐 실험으로 지반의 상대밀도를 증가시켜 관입 시 주변 온도변화에 따라 측정값 변화도 관찰하였다. 측정결과 온도보상회로를 이용하여 측정한 값은 half-bridge 회로로 측정한 값과 차이를 보였으며, 더욱 안정화되고 이상적인 경향을 보였다. 본 논문은 소형 콘 사용시 온 도 영향에 대한 문제를 해소하고 더욱 신뢰성 높은 측정값을 획득할 수 있는 기법에 대하여 제시하였다.

원위치 관입실험기를 활용한 철도 노반 평가 (Railbed Evaluation by using In-situ Penetration Test)

  • 김주한;박정희;윤형구;고태훈;이종섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.261-267
    • /
    • 2011
  • The test fit has commonly used for the evaluation of the railbed condition, and indirect methods by using the compressional wave are also studied. the direct evaluation method by penetration test has not been studied. For the measurement of in-situ cone tip resistance of the railbed with minimizing the disturbance of the upper railbed. the cone penetrometer with the helical type outer rod(CPH) was developed. The outer rod, which has helical screw, is penetrated through the gravel layer and provides the reaction force for cone penetration testing. the cone tip resistances are measured by the mini cone penetrometer, where diameter is 15mm. For the developing the mini cone, strain gauge installation, circuit configuration, penetration rates and calibration process are considered. For the easy penetration of the screw rod in the field, the reaction force stepping plate and guide column are arranged. The screw rod are penetrated through the gravel layer. And the mini cone was pushed into the subgrade railbed at the penetration rate of 1mm/sec. The penetration test shows that the cone tip resistance increases along the depth. In addition, the subgrade condition is evaluated. This study demonstrates that the CPH may be effectively used for the evaluation of subgrade method any damage of the gravel layer.

  • PDF

Quantitative cone-beam computed tomography evaluation of hard and soft tissue thicknesses in the midpalatal suture region to facilitate orthodontic mini-implant placement

  • Oh, Song-Hee;Lee, Sae Rom;Choi, Jin-Young;Kim, Seong-Hun;Hwang, Eui-Hwan;Nelson, Gerald
    • 대한치과교정학회지
    • /
    • 제51권4호
    • /
    • pp.260-269
    • /
    • 2021
  • Objective: To identify the most favorable sites that optimize the initial stability and survival rate of orthodontic mini-implants, this study measured hard and soft tissue thicknesses in the median and paramedian regions of the palate using cone-beam computed tomography (CBCT) and determined possible sex- and age-related differences in these thicknesses. Methods: The study sample comprised CBCT images of 189 healthy subjects. The sample was divided into four groups according to age. A grid area was set for the measurement of hard and soft tissue thicknesses in the palate. Vertical lines were marked at intervals of 0, 1.5, and 3.0 mm lateral to the midpalatal suture, while horizontal lines were marked at 2-mm intervals up to 24 mm from the posterior margin of the incisive foramen. Measurements were made at 65 points of intersection between the horizontal and vertical lines. Results: The palatal hard tissue thickness decreased from the anterior to the posterior region, with a decrease in the medial-to-lateral direction in the middle and posterior regions. While the soft tissue was rather thick around the lateral aspects of the palatal arch, it formed a constant layer that was only 1-2-mm thick throughout the palate. Statistically significant differences were observed according to sex and age. Conclusions: The anterolateral palate as well as the midpalatal suture seem to be the most favorable sites for insertion of orthodontic mini-implants. The thickness of the palate differed by age and sex; these differences should be considered while planning the placement of orthodontic mini-implants.

Diagnostic efficacy of a modified low-dose acquisition protocol for the preoperative evaluation of mini-implant sites

  • Tadinada, Aditya;Marczak, Alana;Yadav, Sumit
    • Imaging Science in Dentistry
    • /
    • 제47권3호
    • /
    • pp.141-147
    • /
    • 2017
  • Purpose: The objective of this study was to compare the outcomes of surgical mini-implant placement when potential mini-implant sites were scanned using a lower-dose $180^{\circ}$ acquisition protocol versus a conventional $360^{\circ}$ acquisition protocol. Materials and Methods: Ten dentate human skulls were used to provide sites for potential mini-implant placement. The sites were randomly divided into 2 groups: $360^{\circ}$ and $180^{\circ}$ cone-beam computed tomography (CBCT) acquisition protocols. A small-volume $180^{\circ}$ CBCT scan and a $360^{\circ}$ CBCT scan of each site were acquired using a Morita Accuitomo-170 CBCT machine and then a mini-implant was placed. A follow-up $360^{\circ}$ CBCT scan was done as a gold standard to evaluate the location of the mini-implant and root perforation. Two raters evaluated the scans. Results: Ninety-eight percent of the mini-implants placed did not perforate any root structure. Two percent of the sites had an appearance suggestive of perforation. On a Likert scale, both raters agreed that their subjective evaluation of the diagnostic quality of the protocols, ability to make and read measurements of the sites, and preferences for the specified diagnostic task were comparable. The Cohen kappa showed high inter-rater and intrarater agreement. Conclusion: In this ex vivo study, we found that the $180^{\circ}$ rotational acquisition was as effective as the conventional $360^{\circ}$ rotational acquisition for the preoperative evaluation of potential mini-implant sites.

치과용 콘빔CT영상에서 미니임플란트를 위한 협측피질골 두께 (Buccal cortical bone thickness on CBCT for mini-implant)

  • 구종국;임성훈;이병진;김재덕
    • Imaging Science in Dentistry
    • /
    • 제40권4호
    • /
    • pp.179-185
    • /
    • 2010
  • Purpose : Cortical bone thickness is one of the important factor in mini-implant stability. This study was performed to investigate the buccal cortical bone thickness at every interdental area as an aid in planning mini-implant placement. Materials and Methods : Two-dimensional slices at every interdental area were selected from the cone-beam computed tomography scans of 20 patients in third decade. Buccal cortical bone thickness was measured at 2, 4, and 6 mm levels from the alveolar crest in the interdental bones of posterior regions of both jaws using the plot profile function of $Ez3D2009^{TM}$ (Vatech, Yongin, Korea). The results were analyzed using by Mann-Whitney test. Results : Buccal cortical bone was thicker in the mandible than in the maxilla. The thickness increased with further distance from the alveolar crest in the maxilla and with coming from the posterior to anterior region in the mandible (p<0.01). The maximum CT value showed an increasing tendency with further distance from the alveolar crest and with coming from posterior to anterior region in both jaws. Conclusion : Interdental buccal cortical bone thickness varied in both jaws, however our study showed a distinct tendency. We expect that these results could be helpful for the selection and preparation of mini-implant sites.

Cone-beam CT와 multi-detector CT영상에서 측정된 CT number에 대한 비교연구 (Comparison of CT numbers between cone-beam CT and multi-detector CT)

  • 김동수;한원정;김은경
    • Imaging Science in Dentistry
    • /
    • 제40권2호
    • /
    • pp.63-68
    • /
    • 2010
  • Purpose : To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Materials and Methods : Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, $\rho$ ($g/cm^3$), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. Results : CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were $\rho$=0.001H+1.07 with $R^2$ value of 0.999 for Somatom Emotion, $\rho$=0.002H+1.09 with $R^2$ value of 0.991 for Alphard VEGA, $\rho$=0.001H+1.43 with $R^2$ value of 0.980 for i-CAT and $\rho$=0.001H+1.30 with $R^2$ value of 0.975 for Implagraphy. Conclusion: CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

시멘트 페이스트의 슬럼프 유동 모사를 위한 분석적 해의 검토 (Review on Analytical Solutions for Slump Flow of Cement Paste)

  • 윤태영
    • 한국도로학회논문집
    • /
    • 제18권3호
    • /
    • pp.21-32
    • /
    • 2016
  • PURPOSES : In this paper, the analytical solutions suggested to simulate the behavior of rheological fluids were rigorously re-derived and investigated for fixed conditions to evaluate the applicability for the solutions on a mini-cone slump test of cement paste. The selected solutions with proper boundary conditions can be used as reference solutions to evaluate the performance of numerical simulation approaches, such as the discrete element method. METHODS : The slump, height, and spread radius for the given boundary and yield stress conditions that are determined by five different analytical solutions are compared. RESULTS : The analytical solution based on fluid mechanics for pure shear flow shows similar results to that for intermediate flow at low yield stresses. The fluid mechanics-based analytical solution resulted in a very similar trend to the geometry-based analytical solution. However, it showed a higher slump at high yield stress and lower slump at low yield stress ranges than the geometry-based analytical model. The analytical solution based on the mini-cone geometry was not significantly affected by the yield criteria, such as von Mises and Tresca. CONCLUSIONS : Even though differences among the analytical solutions in terms of slump and spread radius existed, the difference can be considered insignificant when the solutions were used as reference to evaluate the appropriateness of numerical approaches, such as the discrete element method.

Maxillary protraction using customized mini-plates for anchorage in an adolescent girl with skeletal Class III malocclusion

  • Liang, Shuran;Xie, Xianju;Wang, Fan;Chang, Qiao;Wang, Hongmei;Bai, Yuxing
    • 대한치과교정학회지
    • /
    • 제50권5호
    • /
    • pp.346-355
    • /
    • 2020
  • The treatment of skeletal Class III malocclusion in adolescents is challenging. Maxillary protraction, particularly that using bone anchorage, has been proven to be an effective method for the stimulation of maxillary growth. However, the conventional procedure, which involves the surgical implantation of mini-plates, is traumatic and associated with a high risk. Three-dimensional (3D) digital technology offers the possibility of individualized treatment. Customized mini-plates can be designed according to the shape of the maxillary surface and the positions of the roots on cone-beam computed tomography scans; this reduces both the surgical risk and patient trauma. Here we report a case involving a 12-year-old adolescent girl with skeletal Class III malocclusion and midface deficiency that was treated in two phases. In phase 1, rapid maxillary expansion and protraction were performed using 3D-printed mini-plates for anchorage. The mini-plates exhibited better adaptation to the bone contour, and titanium screw implantation was safer because of the customized design. The orthopedic force applied to each mini-plate was approximately 400-500 g, and the plates remained stable during the maxillary protraction process, which exhibited efficacious orthopedic effects and significantly improved the facial profile and esthetics. In phase 2, fixed appliances were used for alignment and leveling of the maxillary and mandibular dentitions. The complete two-phase treatment lasted for 24 months. After 48 months of retention, the treatment outcomes remained stable.