• 제목/요약/키워드: milling experiment

검색결과 204건 처리시간 0.023초

THE INFLUENCE OF SELECTED CHEMICAL TREATMENTS ON THE RUMINAL DEGRADATION AND SUBSEQUENT INTESTINAL DIGESTION OF CEREAL STRAW

  • Wanapat, M.;Varvikko, T.;Vanhatalo, A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제3권2호
    • /
    • pp.75-83
    • /
    • 1990
  • An experiment was conducted with three ruminally and intestinally cannulated non-lactating cows of Finnish Ayrshire breed, to assess the ruminal degradation characteristics of oat (Avena sativa), rye (Secale cereale) and rice (Oryza sativa) straw by the nylon bag technique, and the subsequent post-ruminal degradation of their rumen-undegraded residues by using the mobile bag technique, respectively. The straw samples were untreated or treated with aqueous $NH_3$ or with urea solution in cold or hot water. The untreated straw samples were milled or chopped, and the treated straw samples were chopped. The constant values a, b, and c were computed according to the exponential equation, where a = intercept of degradation curve at time 0, b = potentially degradable material, c = rate of degradation of band (a+b) = maximum potential degradability (asymptote). It was found that nitrogen contents of chemically treated straw were markedly increased by both $NH_3$ and urea treatments. Milling the samples attributed to a remarkable loss at 0 h incubation time as compared to chopping of the respective samples. However, chemical treatment markedly improved the b value and the subsequent (a+b) values for dry matter, organic matter, neutral-detergent fiber, and acid-detergent fiber of the samples. Furthermore, temperature of the water used in the urea solutions was considered essential, since urea in hot water rather than in cold water seemed to enhance the overall degradability. The disappearance of rumen-incubated straw residues from the mobile bags ranged from 4.5 to 9.6% for the parameters measured. On average, the OM disappearance from bags was clearly higher for the residues of urea treated straw compared to those of ammonia treated straw, but the disappearance of NDF tended, however, to be higher on the ammonia treatment.

Labview 소프트웨어를 활용한 파이프 절단 파워 측정 및 검증 (Measurement and verification of pipe cutting power using Labview software)

  • 장태호;김영식;장태수;류봉조
    • 디지털콘텐츠학회 논문지
    • /
    • 제18권7호
    • /
    • pp.1387-1391
    • /
    • 2017
  • 절단 파워 예측은 가공 툴 또는 공작기계의 최적 설계를 가능하게 하므로 기술 개발에 소요되는 시간과 비용을 줄일 수 있다. 이러한 이유로 정확한 절단파워 예측은 설계과정에서 매우 중요한 부분이다. 본 연구에서는 파이프 절단 파워를 이론적으로 예측하고 실험을 통해 검증한다. 우선, slotting 절단 파워 계산식을 사용하여 파이프의 절단 파워를 예측한다. 다음으로 파이프 절단기로 파이프를 절단하는 실험을 진행하며, 파이프를 절단하는 동안 모터에서 소비하는 파워를 embedded 소프트웨어인 Labview로 측정한다. 그리고 이론으로 계산한 절단파워와 실험으로 측정한 절단파워를 비교하여 정확성을 검증한다. 본 연구에서 사용한 파이프의 재질은 SUS304와 AL6N01이다. 그리고 본 연구에서는 실험을 통해 AL6N01 재질의 specific power 값을 구하였으며 추후 이 재질의 절단 및 절삭파워를 예측하고 최적의 가공기 및 툴을 설계하는데 이 값을 활용할 수 있다.

Alkali붕괴도검정을 위한 최적조건에 대하여 (Optimum Conditions for Alkali Digestibility Test in Rice)

  • 최진용;허문회
    • 한국작물학회지
    • /
    • 제19권
    • /
    • pp.7-13
    • /
    • 1975
  • 백미의 alkali 붕괴도 청정에 필요한 최적조건을 구하기 위하여 test-tube miller를 사용하여 도정하고 25$^{\circ}$, 30$^{\circ}$, 35$^{\circ}$ 및 4$0^{\circ}C$의 온도에서, 1.4%에서 2.8%까지 8수준의 KOH 농도로 일정한 시간을 두고, Indica, Japonica등 10품종을 사용하여 alkali붕괴도 시험을 행하여, 본 정 검정에 영향을 미치는 백미의 도정 정도, KOH 농도 처리온도 및 처리시간을 점토하였다. 그 결과를 요약하면 다음과 같다. 1. Test-tube miller에서 90분간 도정한 시료는 alkali검정에 적당한 도정도를 나타내었다. 2. Japonica와 Indica를동시에 검정할 경우에는 1.8%의 KOH농도에서, Japonica만을 검정할 경우에는 1.4% 혹은 그 이하의 농도에서, 또 Indica만을 검정할 경우에는 2.2%의 농도에서 각각 3$0^{\circ}C$, 18시간 동안 처리하는 것이 최적 조건으로 보였다.

  • PDF

마이크로금형 구배각 제어를 위한 절삭가공조건 예측모델에 관한 연구 (A Study On Prediction Model of Cutting Conditions for Draft Angle Control)

  • 조지현;송병욱;서태일
    • 한국생산제조학회지
    • /
    • 제21권3호
    • /
    • pp.387-393
    • /
    • 2012
  • It is very difficult to determine suitable cutting conditions in order to obtain accurate cutting profiles because machining errors caused by tool deflection depend upon cutting conditions. In this study the relationship between real cutting profiles (inclined shapes and machining errors) and cutting conditions was modeled in order to fabricate draft angle on micro molds. CCD (Central Composite Design) of DOE (Design Of Experiment) and RSM (Response Surface Method) were applied in order to model the relationship between cutting conditions and machining errors. In order to use CCD the range of radial depth of cut was chosen by $10-90{\mu}m$ and the range of feedrate was chosen by 200-300mm/min, and 9 points of cutting conditions were chosen inside determined ranges. Then, actual cutting processes were carried out as respect to 9 points of cutting conditions, draft angles and real cutting profiles were measured on cutting profiles, each response surface function was determined by conducting response surface analysis and the functions were represented by 3-dimensional graphs, contour lines and $101{\times}101$ matrices. Consequently it is possible to determine suitable cutting conditions in order to obtain arbitrary given draft angles and cutting profiles by using modeling. To validate proposed approach in this study suitable cutting conditions were determined by modeling in order to obtain arbitrary given draft angle and cutting profile, and actual cutting processes were carried out. About 95% of good agreement between predicted and measured values was obtained.

치과용 임플란트 적용 비귀금속 코어와 관련된 전조골세포의 변화 (Changes in pre-osteoblast cells associated with non-precious metal cores with dental implants: Pilot test)

  • 박정현;강신영;김종우;김장주;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제40권2호
    • /
    • pp.63-69
    • /
    • 2018
  • Purpose: The purpose of this study is to investigate the non-precious metal core materials used in the dental laboratory to fabricate the implant superstructure by CAD / CAM method. And to observe and compare the morphology and distribution of the osteoblasts in relation to implant osseointegration. Methods: In this study, the mandibular right first molar tooth model was selected as an international standard to produce a single core. Using this model, the impression was made with the silicone rubber, the tooth model was scanned, and a single core was designed and 5-axis milling was performed. The materials used were Cobalt-Chromium and Nickel-Chromium, and the cores for dental implant top structures were fabricated according to the procedures of the dental labs. After the fabrication, the marginal area of the core was separated and cell culture experiment was performed. The osteoblast cells used MC3T3-E1, which is currently widely used. For morphological analysis of osteoblasts, cells were posttreated and observed using CLSM (Confocal Laser Scanning Microscope) and compared. Results: The cell adhesion behavior of the specimen surface measured by CLSM was uniformly distributed in specimen A (Cobalt-Chromium) than in specimen B (Nickel-Chromium). The distribution and changes of the cells were different in the two specimens. Conclusion : It is possible to confirm that specimen A (Cobalt-Chromium) is suitable for the living body through adhesion and proliferation of osteoblasts related to implant osseointegration in the non-precious metal superstructure used after implantation. It is considered that it is preferable to use Co-Cr when fabricating the superstructure.

합금공구강재의 절삭음 음향주파수 분석에 의한 엔드밀 마모 검출에 관한 연구 (A Study on the End Mill Wear Detection by the Analysis of Acoustic Frequency for the Cutting Sound(KSD3753))

  • 이창희;김낙철
    • 융합신호처리학회논문지
    • /
    • 제5권4호
    • /
    • pp.281-286
    • /
    • 2004
  • FMS, FMC, FA, IMS의 구축에 있어서 최하위 단위인 공작기계의 자동화가 중요하다. 이를 위해서는 공작기계의 공구 감시기능(tool monitoring system)이 수행되어야 한다. 본 논문은 공구 감시기능의 자동화를 위해 종전의 공구마모 검출방법과는 달리 엔드밀의 마모상태에 따라 발생하는 절삭음의 음향주파수 분석을 통해 마모정도를 검출하는 방법을 제안하였다. 즉, 머시닝센터에서 공구마모가 잘되는 합금공구강재를 사용하고 이때 발생하게 되는 절삭음(cutting sound)을 음향 분석하여 공구 마모와 관련이 있는 가진 주파수(tooth passing frequency)를 찾아내고 또한 이 주파수의 크기 값과 공구마모(flank wear) 변화를 연구하여 엔드밀의 마모 상태를 추정하였다 이를 위해 본 연구에서는 실험 장비를 구성하고 절삭속도, 엔드밀마모, 공구직경을 절삭조건으로 하여 측정된 절삭음을 FFT 처리하였다. 또한 측정된 값을 회귀분석으로 모델링한 결과 엔드밀 마모 검출오차범위가 5.8% 이내로 나타나 음향주파수 분석에 의한 엔드밀 마모검출 방법의 유효성을 확인할 수 있었다.

  • PDF

내외국산 소맥의 주요품종별 제분성 비교연구 (Studies on the milling quality of major varieties of domestic and foreign produced wheat)

  • 김희갑
    • 한국작물학회지
    • /
    • 제10권
    • /
    • pp.57-60
    • /
    • 1971
  • 한국산 소맥 5품종과 미국산소맥 3품종을 밀과 밀가루의 성분ㆍ회분ㆍ조단백질함량 및 제분율을 조사하였는데 그 성적을 요약하면 다음과 같다. 1. 수분은 한국산밀이 미국산밀보다 품종과 시료에 따른 차가 컸다. 2. 밀의 회분함량이 미국산 밀에서는 경질과 연질에 따라 차가 현저했는데 한국산밀에서는 그렇지 않았다. 3. 제분율은 한국밀중에서는 육성 003 한 품종만이 비교적 높고 기타는 미국밀에 비하여 현저히 낮았다. 4. 밀가루의 회분함량은 품종간의 차를 인정할수 없었다. 5. 밀가루의 조단백질함량은 한국밀보다 미국밀중에 현저히 높은 것이 있었다. 6. 밀의 조단백질함량과 밀가루의 조단백질함량과의 상관은 한국밀에서 보다 미국밀에서 현저하게 높았다.

  • PDF

다양한 바이오매스의 분쇄도 실험을 통한 미분탄 화력발전 적용가능성 연구 (Applicability of Various Biomasses to Pulverized Coal Power Plants in Terms of their Grindability)

  • 강별;이용운;류창국;양원
    • 청정기술
    • /
    • 제23권1호
    • /
    • pp.73-79
    • /
    • 2017
  • 기후 변화 대응을 위한 온실가스 감축 측면에서, 석탄화력발전소에서 바이오매스 사용량은 계속하여 증가되어 왔다. 파리 협정 이후 온실가스 감축 목표치가 더욱 구체화되면서 바이오매스 사용은 급격히 더 많아질 것으로 예상된다. 미분탄 석탄 화력발전에서 바이오매스 혼소시 가장 큰 문제점 중 하나는 바이오매스의 미분성이 석탄에 비해 훨씬 낮다는 것으로, 이를 해결하기 위해 가장 먼저 바이오매스의 미분성 측정 방법을 확립하는 작업이 필요하다. 석탄의 경우 HGI (hardgrove grindability index)측정 장치를 통해 분쇄도 측정이 가능하여 이를 표준으로 삼고 있지만, 바이오매스의 경우 표준 측정 방법이 확립되어있지 않다. 본 연구에서는 볼 밀과 입자 크기별 분포량을 이용한 석탄과 바이오매스의 분쇄 실험을 진행하였다. 실험에는 석탄 1종과 바이오매스 6종을 사용하였다. 분쇄시간에 따른 입자 분포량을 비교하고, $75{\mu}m$ 이하 입자 분포량으로 분쇄도를 평가하였다. 실험결과 반탄화 바이오매스 TBC (torrefied biomass chip)와 TWP (torrefied wood chip)는 발전용 사용적합 기준에 대해 대략적으로 70%의 값을 나타냈다. 다른 바이오매스들의 경우 반탄화 바이오매스와 비교했을 때 분쇄성이 훨씬 더 낮은 결과를 보였다. TBC와 TWP는 수분이 감소하고 섬유질 구조가 분해되는 반탄화 과정을 통해 분쇄가 향상되었다. 또한 분쇄도가 높은 반탄화 바이오매스가 소모전력이 낮게 측정되었다. 본 연구를 통해 바이오매스의 석탄화력발전 적용을 위한 표준화 작업의 기초 자료들을 확보할 수 있다.

신설국도의 시험시공을 통한 표층용 개질 아스팔트 공용성 평가 (Evaluation of Performance and Construction the New National Test Road Sites of Modified Asphalt)

  • 조규태
    • 한국도로학회논문집
    • /
    • 제4권3호
    • /
    • pp.43-49
    • /
    • 2002
  • 국내 아스팔트 포장은 중차량 교통량의 증가와 겨울철 및 여름철의 온도차이가 크게나는 환경조건하에서 공용되고 있다. 이러한 요인으로 인하여 포장 조기파손의 대부분인 소성변형의 문제점이 심각하며, 이에 대한 개선책으로 개질 아스팔트의 적용에 대한 연구들이 활발하게 진행되고 있다. 그러나, 대부분의 개질 아스팔트의 사용이 표층을 절삭하고 택코팅후 시공되고 있으며, 신설도로의 포장이 아닌 유지보수에서 많이 사용되고 있다. 본 연구는 부산지방국토관리청 산하의 신설국도의 도로포장현장에 개질 아스팔트 혼합물이 적용된 기층 위에 표층용 개질 아스팔트인 SBS PMA 혼합물과 PSMA 혼합물에 대하여 2차로로 200m를 시험 시공하였으며. 나머지 구간은 일반밀입도 아스팔트 혼합물로 시공하였으며, 시공에 사용된 재료에 대한 실내시험을 통한 공용성 및 장기 공용성 평가를 실시하고자 하였다. 실내 실험은 마샬안정도시험, 강도시험과 휠트랙킹 시험을 하여 분석하였으며, 현장의 시험 시공시 온도관리 및 평탄성에 대한 평가를 기초로 향후 장기 공용성 평가와 LCC 분석을 실시하여 가장 경제적인 개질 아스팔트를 평가하여 설계에 반영하고자 한다.

  • PDF

치과용 지르코니아 착색제의 건조정도가 지르코니아 색조에 미치는 영향 (Effect of coloring agent dryness on zirconia color)

  • 이주희;박진영;김해중;문윤희;김웅철
    • 한국산학기술학회논문지
    • /
    • 제19권8호
    • /
    • pp.176-182
    • /
    • 2018
  • 심미 치과보철물의 가장 중요한 요인 중의 하나는 치아의 색상이다. 지르코니아는 디자인, 밀링, 착색, 건조, 소결과정을 거치는데, 이때의 지르코니아 착색제의 건조 정도가 색조에 어떠한 영향을 미치는지 알아보고자 한다. 실험을 위해 캐드캠을 이용하여 지르코니아 블록별(L block(LAZOR), Z block(Zircos-E block posterior), A block(AlphaZ))로 각 15개씩 총 45개의 원형 시편을 제작하였다. 그다음 지르코니아 시편을 화학적 착색제를 이용하여 미건조(0sec), 중간건조(10sec), 완전건조(10min)의 온도유지시간(Temperature dwelling time)을 부여하여 오븐에서 건조한 후 제조회사 지시대로 지르코니아 시편을 소결하였다. 분광광도계를 이용하여 색조를 측정하였다. 치과용 지르코니아 시편의 건조유지시간에 따라 색조의 변화를 비교 분석하기 위해 One-way ANOVA를 시행하고, 사후검정으로 Tukey test를 실시하였다. 지르코니아 $L^*$값은 L, A 시편과 $a^*$값은 A 시편, $b^*$값은 Z 시편의 건조 정도에 따라 통계적으로 차이가 없으나 (p>0.05), $L^*$값은 Z 시편과 $a^*$값은 L, Z 시편, $b^*$값은 L, A 시편이 건조 정도에 따라 통계적으로 차이가 있었다(p<0.05). 결론적으로 착색제의 건조유지시간이 길수록 지르코니아 명도를 밝게 하고, 법랑질의 광학적 특성을 증가시킨다.