• Title/Summary/Keyword: millimeter-band

Search Result 281, Processing Time 0.031 seconds

A Study on PAPR reduction in OFDM WPAN system using Millimeter Wave (Millimeter Wave를 이용하는 OFDM WPAN 시스템에서 PAPR 감소에 관한연구)

  • Kim, Wan-Tae;Yoo, Sun-Yong;Cho, Sung-Joon
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.2
    • /
    • pp.139-145
    • /
    • 2008
  • There has been lots of studies on communication systems using millimeter wave recently in many countries, specially in newly assigned 57GHz ~ 64GHz ISM band. Among those studies, IEEE 802.15.3c standard proposes OFDM (Orthogonal Frequency Division Multiplexing) systems for high data rate transmission support. But OFDM method has the PAPR (peak-to-Average Power Radio) problem The PAPR problem is to decline the performance of the transmission system due to signals distorted severely when passing through nonlinear components such as ADC/DAC and power amplifiers. In order to solve the problem of P APR, this paper suggests SSC (Sine Soft Clipping) and analyzes the PAPR, CCDF, PSD, BER by applying SAW(Surface Acoustic Wave) filter and power amplifiers to IEEE 802.15.3.c OFDM WPAN systems.

  • PDF

Millimeter-wave waveguide transducer using extended E-plane probe (연장된 E-plane 프로브를 이용한 밀리미터파 도파관 변환기)

  • Park, Woojin;Choe, Wonseok;Lee, Kookjoo;Kwon, Junbeom;Jeong, Jinho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.1
    • /
    • pp.159-165
    • /
    • 2018
  • In this paper, a low-loss wideband waveguide transducer is proposed for millimeter-wave communication and radar applications. A conventional E-plane probe transducer is generally designed using thin and flexible substrate at millimeter-wave frequencies, considering the very small waveguide size. However, it results in serious performance degradation caused by the bending of the substrate. In order to alleviate this problem and provide a reliable performance, we propose an extended E-plane probe transducer where the probe substrate is extended to and fix ed in the slit area formed in the waveguide wall. It is fabricated using $127{\mu}m$-thick substrate with dielectric constant of 2.2. The measurement in the back-to-hack configuration shows the excellent insertion loss of 1.35 dB (${\pm}0.35dB$) including the loss of 3 cm-long thru waveguide and return loss better than 13.8 dB over entire W-band (75-110 GHz). Therefore, it can be effectively applied for millimeter-wave high-speed communications and high-sensitivity radars.

Combined Hybrid Beamforming and Spatial Multiplexing for Millimeter-Wave Massive MIMO Systems (밀리미터파 Massive MIMO 시스템을 위한 공간 다중화 및 하이브리드 빔 형성)

  • Ju, Sang-Lim;Lee, Byung-Jin;Kim, Nam-Il;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.5
    • /
    • pp.123-129
    • /
    • 2018
  • Recently, as required wireless communication traffic increase, millimeter wave mobile technologies that can secure broadband spectrum are gaining attention. However, the path loss is high in the millimeter wave channel. Massive MIMO system is being researched in which can complement the path loss by beamforming by equiped large-scale antenna at the base station. While legacy beamforming techniques have analog and digital methods, practical difficulties exist for application to massive MIMO systems in terms of system complexity and cost. Therefore, this paper studies a hybrid beamforming scheme for massive MIMO system in the millimeter wave band. Also this paper considers spatial multiplexing scheme to serve multi-users with multiple received antennas. Gains of the beamforming and the spatial multiplexing schemes are evaluated by analyzing the spectral efficiency.

Study on the Brightness Temperature Measurement in the Human Body Using Millimeter-wave Radiometer (밀리미터파 라디오미터를 이용한 인체의 내부 밝기온도 측정에 관한 연구)

  • Jung, Min Kyoo;Kim, Tae Hun;Nah, Seung Wook
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.163-167
    • /
    • 2016
  • We have developed a millimeter-wave radiometer system for applications in the fields of medical imaging. In this paper, we introduced the brightness temperature measurement in the human body using Millimeter-wave Radiometer. Calibration of sensitivity of the radiometer system is essential to measure equivalent temperature (brightness temperature) of objects. We have developed, as a calibration source, a new type of black body for the millimeter wave region with temperature control capability. The system noise figure and temperature sensitivity of the system measured using the blackbody are 3.3 dB and 0.1 K, respectively. The brightness temperature of human body through clothes was measured to be around $38^{\circ}$[C].

Design and Implementation of Antennas for UWB Communications (UWB 통신을 위한 안테나 설계 및 구현)

  • Chae, Jeong-Sik;Ham, Jong-Wan;Jeong, Dae-Ryeong;Jung, Hoe-Kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.497-498
    • /
    • 2011
  • In 21 century, we use a variety of new wireless technologies focuses on broadcasting and Communications. Because of widely spread wireless-service, demand a lot of frequency. It requires various wireless access technologies. Especially UWB, SER, Millimeter Wave etc. Among them, UWB can use wide Frequency band, because it is different from Non-traditional approach which Frequency Band Using the exclusive rights granted by. Furthermore, it does not cause interference to other existing frequency, therefore this technology is attracting attention. In this paper, describe study on a UWB technology, design about useable antenna for UWB communication.

  • PDF

Design of Compact Q-Band Waveguide-to-Microstrip Transition for UAV Millimeter-Wave Radiometer Applications (무인항공기 밀리미터파 라디오미터 응용을 위한 소형 Q대역 도파관-마이크로스트립 전이구조 설계)

  • Woo, Dong Sik;Jeong, Jong-Hyeog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.4
    • /
    • pp.266-269
    • /
    • 2018
  • A compact Q-band waveguide-to-microstrip transition for UAV(Unmanned Aerial Vehicle) radiometer applications is presented. The key features of this transition are simplicity, compactness, easy matching, and lower sensitivity to the dimensions and fabrication tolerances. The simple E-plane patch-type design is insensitive to the backshort cavity enclosure and misalignment between the waveguide and microstrip substrate. The primary parameters are optimized using a three-dimensional(3D) electromagnetic simulator(ANSYS HFSS). It exhibited better than 20-dB return loss at mid-band frequencies with less than 1-dB insertion loss for the back-to-back transition, and a return loss better than 15 dB over the frequency range of 36 GHz to 42 GHz.

Specular Reflectance Measurements of Dielectric Plates in Millimeter Frequency Range

  • Kang, Jin-Seob;Kim, Jeong-Hwan;Kang, Kwang Yong;Yoon, Dae Hwan;Park, Sung Won
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.2
    • /
    • pp.78-87
    • /
    • 2018
  • This paper describes specular reflectance measurements of dielectric plates in three waveguide frequency bands: D-band (110-170 GHz), G-band (140-220 GHz), and J-band (220-325 GHz). The transmit (Tx) part of the proposed specular reflectance measurement system is stationary, while the receive (Rx) part and the material under test (MUT) holder are concentric-rotating with a 2:1 speed ratio for specular reflectance measurements. In specular reflectance measurements, the first step measures the specular reflection coefficients of an MUT and a metal plate on the MUT holder located at the center of the Tx and Rx parts, and the second step calculates the specular reflectance defined by the specular reflection power (i.e., intensity) of the MUT normalized to that of the metal plate. Multiple reflection effects between the Tx and Rx antennas and the MUT on the measured specular reflectance are minimized by averaging out the multiple specular reflectances measured with changing the separation distance between the two antennas by ${\lambda}/8$ intervals. Measurement results of the perpendicular-polarized specular reflectance of commonly used dielectric plates are verified by comparing those with the analytic results and show that the results measured over the overlapped frequency range of the D-/G-bands and at the boundary frequency of the G-/J-bands agree well with the results for the other band, respectively.

Performance Evaluation of Beamforming Scheme in Millimeter Wave Wireless Communication System (밀리미터파 무선통신 시스템에서의 빔포밍 기법 성능 평가)

  • Nguyen, Thanh Ngoc;Jeon, Taehyun
    • Journal of Satellite, Information and Communications
    • /
    • v.11 no.3
    • /
    • pp.133-137
    • /
    • 2016
  • Millimeter wave wireless communication systems, especially those targeting indoor high rate data transfer, have a strong requirement for high quality wireless link. Unfortunately, in this frequency band, the electromagnetic wave has to sustain the high propagation loss caused by the smaller wavelengths. In this scenario, beamforming technique, which enhances the link quality by focusing the radiation power on a direction, becomes one of the most important techniques in millimeter wave band wireless communication. In recent year, there been conducted many research on beamforming to improve the performance of wireless system. In this paper, we evaluate the performance of a simplified codebook-based beamforming scheme which is based on multiple-procedure and three-state beam selection. The simplified scheme significantly reduces beamforming setup time, comparing to the exhaustive searching, two-level searching adopted in IEEE 802.15.3c standard, and also conventional multi-level scheme.

A Study on the Predictive Model of Propagation Path Loss in Millimeter-Wave Band (밀리미터파 대역에서 전파경로손실 예측 모델)

  • Kim, Song-Min
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.42 no.2
    • /
    • pp.23-28
    • /
    • 2005
  • This study was to suggest the propagation path loss and predictive model of propagation path analysis in order to apply the frequency in the millimeter-wave band to the real time inter-vehicle communication system. This study was to suppose the case of inter-vehicle communication on the one-way two-lanes road in the big cites with a lot of traffic jams in order to analyze the effect by the reflected wave of multipath. As a simulation of suggested model, it found out that the propagation path by the reflected wave was about 0.1[m]$\sim$5.1[m] longer than the one by the direct wave during the transmission of 100[m] wave direct path. Also, as a result of comparing the propagation path loss, the loss would be about -0.8[dB]$\sim$-4.2[dB] larger in case of wall reflection and -0.8[dB]$\sim$-1[dB] vehicle reflection. From the result above, this researcher found out that the path loss of reflected wave produced by the walls was about -3.2[dB] larger than the path loss produced by the adjacent vehicles.

A Study on Development of the High-Power Low-Loss Waveguide Circulator for Ka-band Millimeter-Wave Seeker (밀리미터파대역(Ka-대역)탐색기용 고 전력 저 손실 도파관 순환기 개발에 관한 연구)

  • Jung, Chae-Hyun;Han, Sung-Min;Baek, Jong-Gyun;Lee, Kook-Joo;Park, Chang-Hyun;Kwon, Jun-Beom
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.6
    • /
    • pp.83-88
    • /
    • 2017
  • In this paper, a 3-port waveguide circulator of Ka-band millimeter-wave for isolation between transmit channel and receive channel at high power transmit mode is designed and fabricated for the seeker of the guided missile and circulator performance is verified through the S-parameter, high power and operation temperature test. At the configuration design, interface design between a seeker antenna and the circulator is considered and half-height of standard waveguide is applied for minimum and light weight body. The shape of permanent magnet and ferrite is optimized by simulation and tuning dielectrics at each port are placed for the best performance. In Fc(center frequency)${\pm}1000MHz$, designed waveguide circulator has below -20 dB return loss, below 0.5 dB insertion loss and below -23 dB isolation. It is found that circulator characteristics is similar to design results.