• Title/Summary/Keyword: military facilities

Search Result 306, Processing Time 0.026 seconds

Research to define facility type, project consideration and restriction when conceiving civil-military sharing facilities, by applying the Delphi technique (델파이기법을 활용한 민군간 공용 시설유형 및 고려요소 판단 연구)

  • Gong, Keum Rok;Kang, Han-Seung;Ahn, Jin-Ho;Park, Young Jun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.2
    • /
    • pp.57-66
    • /
    • 2018
  • When developing projects to build facilities to be shared by both military bases and surrounding communities, strategies are needed to achieve two objectives: 1) minimize missteps and opposition from local communities in the process of developing and implementing such projects, and 2) promote cost-benefit optimization and user-satisfaction. With aim of promoting co-operation and co-existence between military bases and adjust communities, this research proposes esthetical factors to be considered in conceiving civil-military sharing facilities. It seeks experts' opinions on the development of civil-military sharing facilities, and examines critical factors (economic feasibility, security, and satisfaction, etc.) for project development as well as building types suitable for shared-use between military bases and local residents. It then establishes a method to prioritize facility-type and narrow down design factors (considerations and restrictions) in project development by applying quantitative analysis. The methodological approach of the research employs the Delphi survey method to quantitatively analyze qualitative information drawn from experts' opinions. At the first round of the survey, facility types, items for consideration and restrictions are drawn, and then at the second round of the survey, criticality of each item is analyzed. Finally, it reaches a conclusion on suitability of facility types for civil-military sharing facilities, and selects project considerations and restrictions when developing this kind of project.

Analyzing the Functional Spaces of Military Dining Facilities Using Analytic Hierarchy Process (AHP를 이용한 군 취사식당 기능공간 분석)

  • Lee, Seung-Hoo;Lee, Hyun-Soo;Park, Moonseo;Ji, Sae-Hyun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.5
    • /
    • pp.155-164
    • /
    • 2020
  • This research used Analytic Hierarchy Process(AHP) to analyze the importance and priority of functional space and evaluation factors of each functional space of the military dining facility. Dining in the military is an important factor in restoring combat power and promoting morale. The military dining facility serves as a not only for meals, but also for watching TV, education and club activities. Workers working in dining facility spend most of their work hours in dining facility, perform tasks such as cooking, dishwashing, and leftover disposal, and take breaks. As such, the military dining facility is a space where various functions are performed, and space planning should take into account these various functions when planning the building of the dining facility. However, the criteria for defense and military facilities, which are the basis for planning the space of military dining facility, are calculated only by simply analyzing the standard floor plan to match the size of the person-to. Therefore, when there is space to be reduced in the total area, there are side effects such as leaving visible table space without consideration for priority or functional space, unseen office space, and adjusting the entire area through reduction of the lounge. Accordingly, based on the priority of the space that the staff of the military dining facility considers important, this research aims to analyze the characteristics of each functional space through classification according to its unique function. This can be an indicator that can be used as a basis for future revision of the building floor area standards of the defense and military facilities standards, and it can improve usability with an efficient space plan that takes into account the characteristics of the Korean military and the satisfaction of its workers. Furthermore, efficient use of the defense budget through rational building plans can contribute to budget reduction.

ICAN, I3A Design Criteria for Military Defense Command & Control Facilities (국방 지휘·통제 시설을 위한 ICAN, I3A 설계기준)

  • Jo, Yun-Jeong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.4
    • /
    • pp.806-815
    • /
    • 2017
  • Korean Ministry of National Defense has criteria for military facilities but most were made with the focus on design criteria of facilities and especially in the case of information and communication, only overall criteria with the level of conceptual design are suggested without details. By comparing the design standards of ICAN and I3A that are applied in US Department of Defense, this study will suggest the desirable design standard of Korean military on command/control facilities and general/administrative facilities.

A Study on the Shipyard of the Costal Counties and the Naval Castle in the Southern Gyeongsang-do (경상도 남부지역 연해 군현과 수군영진의 선소(船所)에 관한 연구)

  • Kwon, Soon-Kang;Lee, Ho-Yeol
    • Journal of architectural history
    • /
    • v.28 no.2
    • /
    • pp.7-18
    • /
    • 2019
  • The Chosun Dynasty established and implemented measures to prevent Japanese invasion into the southern coast. To this end, the number of naval vessels and the number of ships were increased, and a shipyard(船所) was constructed to protect the safety of the vessels. The shipyard is a port facility where military vessels are anchored and repaired, as well as public facilities that are needed for military training on public and land, as well as facilities for storing supplies and equipment needed for ships on land and defense at the port entrance. Despite being such an important facility for national defense, Shipyard has not been noticed. Studies have shown that the position of shipyard is divided into the riverside type and the riverbank type, which is due to the topographical features of Korea. The repair cycle of naval vessels, the carrying out of Yeonhun(prevent the water from decaying the part of the ship, a raw tree was burned to smoke) and the place of sea training also affected the construction of the Gul River(掘江). The space structure of shipyard is divided into port entry facilities for monitoring and controlling at the entrance to the harbor, border facilities for folding and repairing military vessels, and land facilities for holding land exercises and administrative work of military vessels and military equipment.

Effect of Military Training Noise on Life Satisfaction of Residents Living Near Military Facilities (군사훈련 소음이 주민들의 삶의 만족도에 미치는 영향)

  • Kim, Wook;Cho, Young-Moo
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.10
    • /
    • pp.497-505
    • /
    • 2022
  • This study was conducted to confirm the effect of noise generated by military training on the life satisfaction of residents living near military facilities. In 2017, an interview survey was conducted on 904 adult residents living near military facilities. The life satisfaction score of the survey subjects was analyzed to be 3.17 out of a total of 5 points, which was confirmed to be lower than that of previous studies on adults. Factors influencing the life satisfaction of residents around military facilities were analyzed. Life satisfaction as dependent variables, demographic factors and physical damage experience factors, and mental damage experience factors were selected as independent variables. As a result of regression analysis, it was analyzed that monthly average household income (coef.=0.09, p<0.001), emotional anxiety (coef.=-0.34, p<0.001), and stress (coef.=-0.05, p<0.001) affected life satisfaction. This study is expected to be used as basic data for establishing policies to improve the life satisfaction of residents living in areas around military facilities.

The Comparative Study on the Satisfaction of the Physical Therapy facilities in the front Military hospitals and Divisions

  • Park, Giwan;Jung, Jihye;Lee, Seungwon
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.2
    • /
    • pp.217-224
    • /
    • 2021
  • Objective: This study is about the physical therapy facilities and environmental and service satisfaction of patients visiting in the front military hospitals and divisions. Design: Survey study Methods: Prior to this survey, 28 users of the front division and military hospital were surveyed in advance to verify the survey through reliability analysis. For this survey, 1,300 questionnaires were distributed to seven frontline divisions and three military hospitals, of which 578 military hospitals and 479 divisions were collected. Among them, 1,042 pieces of data were used for the analysis, excluding 15 questionnaires that exceeded the research period of the division. Analysis methods used Cronbach-α and multiple regression for mean comparison analysis, factor analysis for validation, and reliability verification to verify differences between groups. Results: As a result of the satisfaction analysis, the division's stage satisfaction was higher than that of military hospitals, and as a result of analyzing the satisfaction items by sector, accessibility, re-visit doctors, and professionalism accounted for a large portion in the field of physical therapy services. As a result of a regression analysis, the factors that affect the satisfaction of physical therapy had the greatest impact on facility and environmental satisfaction, and expertise in physical therapy services. Conclusions: In the future, it will be necessary to improve the comfort of the physical therapy room and the expertise of physical therapy in order to improve the satisfaction level of physical therapy at military medical facilities.

Indoor Radon Risk Assessment by Applying Measurement Concentrations and Exposure Times for Military Facilities and Underground Shopping Malls near Subway stations (군부대 시설 및 지하철 역사 주변 지하상가의 측정농도와 노출시간을 이용한 실내에서의 라돈 위해성 평가)

  • Kong, Jin Seok;Kim, Younghee
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.5
    • /
    • pp.345-351
    • /
    • 2016
  • Objectives: The objective of this study was to conduct risk assessment using indoor radon concentration and exposure times. Methods: The target facilities were military facilities before and after the application of radon reduction processes and underground commercial facilities in major subway stations in Seoul. Indoor radon concentrations were measured by passive sampler. Results: Radon concentrations in 13 military facilities were initially higher than the guidelines, but the levels were below guidelines after the application of radon reduction processes. Underground shopping mall radon concentrations near subway stations in Seoul satisfied the guidelines. However, indoor radon effective doses after radon reduction processes in some military facilities and those in underground shopping malls belonged to International Commission on Radiological Protection (ICRP) groups needing control management. Conclusion: Indoor radon management requires risk assessment data that takes into account working time (or residence time) in addition to management according to concentration guidelines.

A Feasibility Study Evaluating Standards for Covered-Positions Built with Concrete Materials (소부대 전투시설 방호두께 기준의 타당성 검토에 대한 기초 연구)

  • Kim, Suk-Bong;Kang, Young-Chul;Lee, Pil-Jae;Baek, Sang-Ho;Park, Young-Jun;Woods, Paul
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.571-576
    • /
    • 2009
  • In terms of protective engineering, there are no noticeable researches regarding covered-positions for smaller units in South Korea. So, standards to maintain and build protective facilities for larger units have been applied in ones for smaller units without any adjustment. The previous study was to calculate penetration depth of the concrete walls because the experiment performed indoor. In this outdoor experiment, velocity of projectile impact as one of the other important factors was considered to prove the validity of 30cm concrete wall thickness as effective protective level of the covered-position. Random effects and extraneous variables which could be occurred in outdoors experiment were controlled with statistical techniques. As a result, velocity of projectile impact was significant variable and the given standard, 30cm thickness of concrete walls was as valid as ever.

A Study on the Planning of Civil Defense Shelter and Design 3 - Focusing on Considerations Related to Military Threat - (민방위 대피시설 계획 및 설계 방안에 관한 연구 3 - 군사위협에 따른 고려 요소를 중심으로 -)

  • Park, Namkwun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.97-106
    • /
    • 2015
  • Currently, South Korea is exposed to various attacks of North Korea such as traditional, nuclear, and ABC weapons. Now it is hard to make an accurate estimate the damage may have been occurred to citizens due to those attacks. It is only possible to assume the rough outline. As a countermeasure to such military threats of North Korea, government-aided evacuation facilities services are going along across the board concerning the object, installation range, budget, and drawing standards. Whereas, in case of public evacuation facilities, there is no special regulation or principle in designation. Since various facilities are regarded as applicable, any protection against military threats can't be anticipated. In this study, military threats provoked by North Korea are figured out, thus the problem of plan and design that public evacuation facilities have are pointed out. This study suggest the result and proposal.

Performance Evaluation for Deteriorated Masonry in Military Facilities (조적조 노후 군시설의 성능 평가)

  • Yang Eun-Bum;Shin kyoung-Hee;Hwang Jong-Hyun;Kim In-Ho;Kim Yong-In;Park Tae-keun;Lee Chan Shik
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.434-438
    • /
    • 2001
  • Military facilities with masonry construction have a great portion in the whole military facilities. But lots of them have been used for more than 20 years, the degree of deterioration of the facilities are very serious. Futhermore, as small budget for the facilities maintenance and poor maintenance, the performance of the aged masonry facilities have continually decreased. We suggest a structural performance assesment criteria for the military facility through literature review, interview with experts and questionnaire. The assesment of structural performance includes the inclining and sinking degree of the facilities, durability of materials and resisting force of the structural members.

  • PDF