• 제목/요약/키워드: mid-rise

검색결과 239건 처리시간 0.03초

Determination of lateral strength and ductility characteristics of existing mid-rise RC buildings in Turkey

  • Ucar, Taner;Merter, Onur;Duzgun, Mustafa
    • Computers and Concrete
    • /
    • 제16권3호
    • /
    • pp.467-485
    • /
    • 2015
  • This paper presents a comprehensive work on determination of yield base shear coefficient and displacement ductility factor of three to eight story actual reinforced concrete buildings, instead of using generic frames. The building data is provided by a walkdown survey in different locations of the pilot areas. Very detailed three dimensional models of the selected buildings are generated by using the data provided in architectural and reinforcement projects. Capacity curves of the buildings are obtained from nonlinear static pushover analyses and each capacity curve is approximated with a bilinear curve. Characteristic points of capacity curve, the yield base shear capacity, the yield displacement and the ultimate displacement capacity, are determined. The calculated values of the yield base shear coefficients and the displacement ductility factors for directions into consideration are compared by those expected values given in different versions of Turkish Seismic Design Code. Although having sufficient lateral strength capacities, the deformation capacities of these typical mid-rise reinforced concrete buildings are found to be considerably low.

Changing Transmission Pattern of Plasmodium vivax Malaria in the Republic of Korea: Relationship with Climate Change

  • Park, Jae-Won
    • Environmental Analysis Health and Toxicology
    • /
    • 제26권
    • /
    • pp.1.1-1.6
    • /
    • 2011
  • Plasmodium vivax malaria has occurred annually in the Republic of Korea (ROK) since its re-emergence in 1993. P. vivax malaria in ROK has been strongly influenced by infected mosquitoes originating from the Democratic People's Republic of Korea. Korean P. vivax malaria has shown typical characteristics of unstable malaria transmitted only during the summer season, and displays short and long incubation periods. The changing pattern of the transmission period can be predicted by analyzing the seasonal characteristics of early primary attack cases with a short incubation period. Such cases began to gradually occur earlier in the 1990s after the re-emergence. Most of the malaria cases after mid-August are presumed to be early primary attack, short incubation period cases. Only primary transmission was possible until the early 2000s, whereas up to fourth or fifth transmission occurred in the mid-2000s. The results indicate that the length of transmission period has been gradually extending, which may be ascribed to a climate change-mediated temperature rise. Malaria and climate data should be integrated to analyze and predict the influence of climate change on malaria occurrence in ROK.

A comparative study on the seismic provisions of different codes for RC buildings

  • Bilgin, Huseyin;Hadzima-Nyarko, Marijana;Isik, Ercan;Ozmen, Hayri Baytan;Harirchian, Ehsan
    • Structural Engineering and Mechanics
    • /
    • 제83권2호
    • /
    • pp.195-206
    • /
    • 2022
  • Significant structural damages due to earthquakes reveal the importance of seismic design provisions. This paper presents a comparison between the seismic design provisions of Albania, Croatia, Iran, and Turkey for the design of mid-rise reinforced-concrete (RC) frames. Information on the historical development of the considered provisions are given. The code provisions are compared, illustrating the main differences in the minimum requirements for column and beam detailing and analysis for mid-rise RC frames. 4-story, 5-story, and 6-story buildings are designed according to each design code, and their performance is evaluated comparatively by using a displacement-based adaptive pushover procedure and eigenvalue analysis. It is observed that recent Turkish code has the highest and Albanian code has the lowest level of requirements in terms of member size and reinforcement detailing. The considered models indicate 15%, 20% and 50%, lower period values than the Croatia, Iran and Albania buildings, respectively. Additionally, building models per Croatia, Iran and Albania codes have 30%, 35% and 65% less base shear capacity when compared to Turkish building codes. Building models per Croatia and Iran codes indicate similar properties both in terms of strength and stiffness.

A new optimized performance-based methodology for seismic collapse capacity assessment of moment resisting frames

  • Maddah, Mohammad M.;Eshghi, Sassan;Garakaninezhad, Alireza
    • Structural Engineering and Mechanics
    • /
    • 제82권5호
    • /
    • pp.667-678
    • /
    • 2022
  • Moment-resisting frames (MRFs) are among the most conventional steel structures for mid-rise buildings in many earthquake-prone cities. Here, a simplified performance-based methodology is proposed for the seismic collapse capacity assessment of these buildings. This method employs a novel multi-mode pushover analysis to determine the engineering demand parameters (EDPs) of the regular steel MRFs up to the collapse prevention (CP) performance level. The modal combination coefficients used in the proposed pushover analysis, are obtained from two metaheuristic optimization algorithms and a fitting procedure. The design variables for the optimization process are the inter-story drift ratio profiles resulting from the multi-mode pushover analyses, and the objective values are the outcomes of the incremental dynamic analysis (IDA). Here, the collapse capacity of the structures is assessed in three to five steps, using a modified IDA procedure. A series of regular mid-rise steel MRFs are selected and analyzed to calculate the modal combination coefficients and to validate the proposed approach. The new methodology is verified against the current existing approaches. This comparison shows that the suggested method more accurately evaluates the EDPs and the collapse capacity of the regular MRFs in a robust and easy to implement way.

Assessment of seismic retrofitting for soft-story buildings using gapped inclined brace system

  • Tohamy, Mohamed. A.;Elsayed, Mostafa. M.;Akl, Adel. Y.
    • Earthquakes and Structures
    • /
    • 제22권3호
    • /
    • pp.319-330
    • /
    • 2022
  • Retrofit of soft-story buildings due to seismic loads using Gap-Inclined-Brace (GIB) system is considered a new retrofit technique that aims to maintain both strength and stiffness of structure. In addition, it provides more ductility and less P-delta effect, and subsequently better performance is observed. In this paper, the effect of the eccentricity between GIB and the retrofitted column due to installation on the efficiency of the retrofitting system is studied. In addition, a modification in the determination method of GIB properties is introduced to reduce the eccentricity effect. Also, the effect of GIB system on the seismic response of mid-rise buildings with different heights considering soft-story at various heights has been studied. A numerical model is developed to study the impact of such system on the response of retrofitted soft-story buildings under the action of seismic loads. To achieve that goal, this model is used to perform a numerical investigation, by considering five case study scenarios represent several locations of soft-story of two mid-rise reinforced concrete buildings. At first, Non-linear static pushover analysis was carried out to develop the capacity curves for case studies. Then, Non-linear time history analyses using ten earthquake records with five peak ground accelerations is performed for each case study scenario before and after retrofitting with GIB. The results show that large GIB eccentricity reduce the ultimate lateral resistance and deformation capacity of the retrofitting system. Moreover, the higher the retrofitted building, the more deformation capacity is observed but without significant increase in ultimate lateral resistance.

식도의 중부계실: 1례 보고 (A Traction Diverticulum of the Mid-thoracioc Esophagus: A Case Report)

  • 김규태
    • Journal of Chest Surgery
    • /
    • 제8권1호
    • /
    • pp.51-56
    • /
    • 1975
  • The typical traction diverticulum of the mid-thoracic esophagus is conical or funnel shaped with a wide orifice, is small (rarely exceeding 2cm in length), and is situated horizontally or extends superiorly. It is a true diverticulum, having a complete investment by the esophageal muscle coats. Each of these characteristics promotes easy emptying of the diverticulum. Since food accumulation is presented, there is no tendency to progressive enlargement of the sac, and no associated dysphagia. The diverticula of mid-esophagus rarely develop and rarely produce symptoms. When symptoms develop, they are usually caused by granulomatous infections of the mediastinal lymph nodes. And also such diverticula only rarely give rise to significant complications, the most serious of which is a tracheobronchial fistula. Generally when such complications develop or a diverticulum itself produces symptoms, moderate or severe, surgery intervenes. A case of mid-esophageal diverticulum, traction type, which surgically treated with good results, was experienced at the Department of Thoracic Surgery of Kyung-Pook University. School of Medicine. In this case, there were substernal discomfort, acid regurgitation, and back pain for about 6 months. On the operative findings, it was noticed that the diverticulum was developed by traction and adhesion of perihilar nodes to the esophageal wall. The diverticulum was a small finger tip size and the neck of it was obscure. The surrounding inflammatory change was minimal.

  • PDF

RCP 시나리오 기반 WRF를 이용한 CORDEX-동아시아 2단계 지역의 가까운 미래 극한기온 변화 전망 (Near Future Projection of Extreme Temperature over CORDEX-East Asia Phase 2 Region Using the WRF Model Based on RCP Scenarios)

  • 서가영;최연우;안중배
    • 대기
    • /
    • 제29권5호
    • /
    • pp.585-597
    • /
    • 2019
  • This study evaluates the performance of Weather Research and Forecasting (WRF) model in simulating temperature over the COordinated Regional climate Downscaling EXperiment-East Asia (CORDEX-EA) Phase 2 domain for the reference period (1981~2005), and assesses the changes in temperature and its extremes in the mid-21st century (2026~2050) under global warming based on Representative Concentration Pathway (RCP) scenarios. MPI-ESM-LR forced by two RCP scenarios (RCP2.6 and RCP8.5) is used as initial and lateral boundary conditions. Overall, WRF can capture the observed features of temperature distribution reflecting local topographic characteristic, despite some disagreement between the observed and simulated patterns. Basically, WRF shows a systematic cold bias in daily mean, minimum and maximum temperature over the entire domain. According to the future projections, summer and winter mean temperatures over East Asia will significantly increase in the mid-21st century. The mean temperature rise is expected to be greater in winter than in summer. In accordance with these results, summer (winter) is projected to begin earlier (later) in the future compared to the historical period. Furthermore, a rise in extreme temperatures shows a tendency to be greater in the future. The averages of daily minimum and maximum temperatures above 90 percentiles are likely to be intensified in the high-latitude, while hot days and hot nights tend to be more frequent in the low-latitude in the mid-21st century. Especially, East Asia would be suffered from strong increases in nocturnal temperature under future global warming.

황체기능 평가에 관한 연구 (A Study on the Methods to Evaluate Adequacy of Luteal Function)

  • 배광범;김정구;문신용;이진용;장윤석
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제13권2호
    • /
    • pp.113-119
    • /
    • 1986
  • The present study was designed to assess the relationships between the methods to evaluate adequacy of luteal function. We measured mid-luteal serum progesterone levels by radioimmune assay, luteal phase lengths and mean post-ovulatory basal body temperature rise rates by basal body temperature charts in 40 in-phase-cycle infertile patients and 38 out-of-phase-cycle patients who underwent late-luteal endometrial biopsies at the sterility clinic of Department of Obstetrics and Gynecology, Seoul National University Hospital from Jan. 1986 to Aug. 1986. The results were summarized as follows: 1. No significant differences were found in mean age, mean duration of infertility, mean mid-luteal serum progesterone levels, and mean post-ovulatory temperature rise rate between in-phase-cycle patients and out-of-phase-cycle patients, but significant difference in mean luteal phase length between 2 groups was identified. 2. 91% of total patients sho had luteal phase lengths of less than 11 days showed out-of-phase-cycles. 3. In out-of-phase-cycle group with luteal phase lengths of less than 11 days, 50% had an endometrial lag of at least 4 days, but 10.7% had an endometrial lag of 4 or more days in group with luteal phase lengths of more than 11 days. 4. There was no significant correlation between mid-luteal serum progesterone level and endometrial lag of late luteal phase endometrial biopsy.

  • PDF

도시 건조환경 유형에 따른 서울시 주간 지표면 온도 변동성 분석: ECOSTRESS 데이터의 활용 (Examining Diurnal Thermal Variations by Urban Built Environment Type with ECOSTRESS Land Surface Temperature Data: Evidence from Seoul, Korea)

  • 전규원;박유진
    • 지역연구
    • /
    • 제40권2호
    • /
    • pp.107-130
    • /
    • 2024
  • 도시의 지표면 기온 변화는 도시민의 열 쾌적성, 에너지 소비, 나아가 건강에 영향을 미치는 주요한 환경요인이다. 많은 연구가 도시 지표면 기온과 도시 건조환경(built-environment) 형태 간의 관계를 탐색해 왔으나 대부분 극궤도위성 자료를 사용해 정오 시간대 기온만을 분석하였다. 본 연구는 다양한 시간대 지표면 기온을 관측하는 ECOSTRESS 위성 자료를 활용하여 서울시 여름철 지표면 기온의 주간 변동을 탐색하였으며 기온 변동이 건조환경 유형별로 차별적으로 나타나는지 분석하였다. ECOSTRESS는 2018년 발사된 NASA 위성으로 점진 변화 궤도를 운항하며 다양한 시간대 지표면 온도를 70m 고해상도로 관찰한다. 본 연구는 2019~2022년 이른 오전(6:25AM)과 늦은 오후(5:26PM)에 걸친 자료를 수집하여 서울시 지표면 온도의 시계열 자료를 구축하였다. 환경 특성을 반영하는 녹지, 수면, 건축 형태(건폐율, 용적률, 높이) 데이터를 기반으로 계층적 군집분석을 실시해 8가지 건조환경 유형을 도출하였으며, 유형별 온도변동 특성을 비교하였다. 각 유형은 저층고밀거주지(low-rise compact), 저밀아파트단지(low-BCR Apt.), 강변 중고층 주거단지(Riverside Mid-rise Apt.), 중고층 용도혼합지역(mid-to-high-rise mixed use), 고층고밀지역(high-rise compact), 초고층빌딩(skyscrapers), 산림, 수면(하천)을 나타내었다. 분석 결과, 지표 기온의 공간적 격차는 새벽 이후 증가하여 정오(12:04)에 극대화된 뒤 다시 감소하였으며, 기온 변화가 급격한 지역과 안정적인 지역이 구분되었다. 저층 고밀 거주지와 고층 고밀지역의 경우 기온이 빠르고 높게 증가하여 기온변동성이 높았고, 저밀 아파트단지는 기온이 온화하고 완만하게 증가하며 기온 변동성이 낮았다. 건조환경 유형 간 평균기온의 서열은 시간별로 변화하지 않고 유지되었다. 이러한 결과는 폭염과 일교차 증가에 적응할 수 있는 도시형태에 시사점을 제공한다.

An Analysis of X-Factor, Triple X-Factor, and the Center of Pressure (COP) according to the Feel of the Golf Driver Swing

  • Kim, Yong-Seok;So, Jae-Moo
    • 한국운동역학회지
    • /
    • 제26권3호
    • /
    • pp.265-272
    • /
    • 2016
  • Objective: The aim of this study was to analyze X-factor, triple X-factor, and the center of pressure (COP) according to the feel of golf driver swing. Method: For this research, 9 golfers from the Korea Professional Golfers' Association (age: $30.11{\pm}2.98yrs$, height: $178.00{\pm}8.42cm$, weight: $76.22{\pm}8.42kg$, experience: $10.06{\pm}3.11yrs$) were recruited to participate in the experiment. Twelve Motion Analysis Eagle-4 cameras were installed and an image analysis was conducted by using the NLT (non-linear transformation) method, and 2 units of Kistler type 5233A dynamometer were used to measure ground reaction force. The sampling ratio was set at 1000 Hz. The golfers each took 10 swings by using their own driver, and chose the best and worse feel from among 10 shots. A paired-sample t-test was used to analyze the results. Results: In regard to feel, no change in head speed, X-factor, and the triple X-factor's X-factor stretch, hip rise, and head swivel, was observed (p>.05). Regarding ground reaction force, a difference was observed between the top of the backswing (p<.05) and impact (p<.05) in the vertical force of the left foot. For COP, a difference was also observed between the mid backswing (p<.001), late backswing (p<.001), and top of the backswing (p<.05) for the right foot X-axis and Y-axis mid follow through (p<.01). Conclusion: It can be reasoned that, irrespective of feel, the head speed, X-factor and triple X-factor's X-factor stretch, hip rise and head swivel did not have an effect on drive distance for domestic golfers, and the vertical reaction force of the left foot and left-right movement span's pressure dispersal of the right foot had an increasing effect on drive distance.