• Title/Summary/Keyword: microwave system

Search Result 877, Processing Time 0.028 seconds

Low-Temperature Sintering and Microwave Dielectric Properties of $(ZnMg)TiO_3$ System ($(ZHMg)TiO_3$계 세라믹스의 저온소결과 마이크로파 유전특성)

  • Sim, Woo-Sung;Bang, Jae-Cheol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.321-324
    • /
    • 2003
  • The effects of various sintering additives such as $Bi_2O_3+V_2O_5$, $BiVO_4$, $B_2O_3$, and $CuO+V_2O_5$ on the low-temperature sintering and microwave dielectric properties of $(ZnMg)TiO_3$ system were studied. Sintering was enhanced by the sintering additives and highly dense samples were obtained for $(Zn_{0.8}Mg_{0.2})TiO_3$ at the sintering temperature of $910^{\circ}C$. $(Zn_{0.8}Mg_{0.2})TiO_3$ with 6.19 mol.%$B_2O_3$ was found to show the best sintering and microwave dielectric properties.

  • PDF

A Design and Measurement of a Reference Signal Generator for a Radar System

  • Kim, Dong-Sik;Kim, Min-Chul;Lee, Su-Ho;Baik, Seung-Hun;Kwon, Ho-Sang;Jeong, Myung-Deuk
    • Journal of electromagnetic engineering and science
    • /
    • v.9 no.3
    • /
    • pp.118-123
    • /
    • 2009
  • This paper discusses the design and fabrication of a reference signal generator for a naval radar system, including the vibration environment test. The transmit signals of the S-band radar system are synthesized by the reference signal and the phase noise must lower than - 130 dBc/Hz at a 10 kHz offset frequency. To achieve this specification, the phase noise of the reference signal needs to be less than -165 dBc/Hz at a 10 kHz offset. For achieving very low phase noise performance by the reference signal generator, the phase locked loop technique is applied with a 10 Hz loop bandwidth. Also, this reference signal generator has ${\pm}0.35\;ppb$ short-term stability to minimize instant phase errors and high vibration sensitivity against a ship's shaking, unbalanced rotating of antennas and so on.

Array Topology of Microwave Wireless Power Transmission on Electronic Power System (전력계통 연계를 대비한 마이크로파 무선전력 송수신기 에레이 구성 고찰)

  • Lee, Dongho
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.1
    • /
    • pp.88-91
    • /
    • 2015
  • Wireless power transmission (WPT) is a technology using free space as a conductor for transmitting electric power, which aims to transfer not just the transmission signal but also the electrical energy itself. This paper takes issue with the microwave wireless transmission technology utilizing in long-distance transmission. To construct the WPT system, several components are needed, such as RF Oscillator which converts AC power to RF through DC status, high gain antenna and RF rectifier that converts RF back to DC. The array topology is good a candidate for wide use. The objective of this research is to study the efect of the WPT systmem on electric power system.

Modeling and Analysis of the Phase Noise in a Frequency Synthesizer for a Radar System (레이더용 주파수합성기의 위상잡음 모델링 및 분석)

  • Kim, Dong-Sik;Kim, Min-Cheol;Lee, Su-Ho;Jeong, Myeong-Deuk;Kwon, Ho-Sang
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.818-824
    • /
    • 2011
  • In this paper, we proposed a phase noise model of a frequency synthesizer for a radar system. Especially, it was proposed a phase noise model in a DAS(Direct Analog Synthesizer) and a frequency up converter system using Leeson's model. The proposed phase noise model was derived from the measurement data of model 1 and evaluated by adapting to model 2 and model 3 frequency synthesizers. The prediction phase noise by modeling was totally matched to the measured data and the effective analysis of the phase noise was done in a frequency synthesizer and a frequency converter of radar system.

Fabrication of Tomography System Using Microwave Multi-Channel Transceiver (전자파 기반 다채널 토모그래피 테스트베드 제작)

  • Kim, Hyuk-Je;Lee, Jong-Moon;Lee, Youn-Ju;Son, Seong-Ho;Jeon, Soon-Ik
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1093-1094
    • /
    • 2008
  • A tomography system using microwave multi-channel transceiver was fabricated and measured. The tomography system is applicable to detection of breast cancers in a human body. This system is configured by microwave muiti-channel transceivers, a illumination chamber housing monopole antennas and coupling liquid, and image reconstruction algorithm solving inverse scattering problem.

  • PDF

Design and manufacture of atomatic microwave leakage inspection system (전자 오븐의 누설 고주파 자동 검사 시스템 설계와 제작)

  • 이만형;송지복;이석희;정영철;안희태
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.492-496
    • /
    • 1987
  • The testing philosophy and control schemes are investigated and applied to construct the Automatic Microwave Leakage Inspection System (AMLIS) . AMLIS is consists of three major parts such as Material Handling Mechanism, Fine Positioning Mechanism and Scanning Mechanism. The material Handling unit is designed to perform loading and unloading microwave oven onto the testing point by pneumatic cylinder and vacuum pump. The Fine positioning part includes X-Y-.THETA. table and distance sensing equipment. The scanning part is composed of five SCARA robots, which traverse X-Y-Z catesian coordinates respectively. The leakage testing probes are placed at the end of this each robot then the path and speed are both controlled via microprocessors. A performance test of this system combined with electric parts and software is done and the basic major function of system are accomplished.

  • PDF

Electromagnetic Field Distribution Analysis for Microwave Continuity Dry System (마이크로웨이브 연속 건조기를 위한 전자계 분포 해석)

  • 곽영복;김민준
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.214-217
    • /
    • 2001
  • Microwave continuous drier system mostly uses the ISM frequency band(915MHz or 2450MHz). It dry the material off from it's inside by the electromagnetic wave. The structure whose openings is needed for dry system to continuously feeds a materials into the system. So it is too difficult to shield the leakage of electromagnetic energy through the apertures. In this paper, we designed microwave continuous drier structure which operates at 2450MHz and analyzed the field distributions at the internal and external region of the structure.

  • PDF

Noninvasive Brain Stimulation Using a Modulated Microwave Signal

  • Seo, Taeyoon;Oh, Seongwoog;Jung, Dahee;Huh, Yeowool;Cho, Jeiwon;Kwon, Youngwoo
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.1
    • /
    • pp.70-72
    • /
    • 2018
  • We propose a microwave signal generation system for brain stimulation. The existing brain stimulation system uses a signal of several tens of kHz, and the magnetic field distribution is wide. Microwave is used to locally limit the distribution of the electromagnetic field and to change the action potential of the cell with less power. The switch modulates the microwave signal to obtain a pulse envelope. The action potential of the cell can be controlled to the excitation/inhibition state by adjusting the repetition frequency. These results are confirmed by measuring the cell potential of the mouse brain.

Development of simple and continuous microwave source using a microwave oven (전자오븐을 이용한 간편하고 연속적인 마이크로파 발생 장치 개발)

  • 권기청;김재현;김정희;이효석;전상진;허승회;최원호
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.3
    • /
    • pp.290-295
    • /
    • 2000
  • In order to utilize as a pre-ionization means for reproducible ohmic plasma on KAIST-TOKAMAK, a simple, safe, economical and continuous microwave source has been developed using a home kitchen micro-wave oven. The magnetron used in the study can provide 500 W of power at 2.45 GHz. A conventional magnetron in a home kitchen microwave oven generates microwave for 8 ms at every 16 ms periodically due to the periodic (60 Hz) high voltage applied to the magnetron cathode. In order to generate continuous microwave which is suitable for tokamak pre-ionization, the magnetron operation circuit has been modified using a DC high voltage (5 kV, 1 A) power supply. It provides high-voltage with small ripple for magnetron cathode bias. Using the developed magnetron system, electron cyclotron resonace heated (ECH) plasmas were produced and the characteristics of the system were studied by diagnosing the ECH plasma using Langmuir probe and $H_{\alpha}$ emission diagnostics.

  • PDF

Characteristics of Alkali-activated Natural Hwangtoh Paste Utilizing Microwave Heating

  • Kim, Baek-Joong;Yi, Chong-Ku;Kang, Kyung-In
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.5
    • /
    • pp.503-509
    • /
    • 2012
  • In this study, the potential use of indigenous natural loess(Hwangtoh) as a new construction material, via alkali activation in conjunction with microwave heating, was investigated. Hwangtoh pastes with three different mix proportions of varying alkali liquid concentrations at a constant liquid-to-Hwangtoh ratio of 0.55 were prepared. Through the investigation it was found that it is possible to prepare Hwangtoh paste with $19.02N/mm^2$ at the age of 4 hours with the alkali solution of 8M NaOH and 1:4.5 mass ratio of liquefied $Na_2SiO_3$ at the curing temperature of $60^{\circ}C$ by microwave heating. The strength development at early age of the alkali activated Hwangtoh paste specimens may be attributed to both a higher rate of reaction and moisture evaporation due to microwave heating.