• Title/Summary/Keyword: microwave digestion system

Search Result 34, Processing Time 0.024 seconds

Determination of Heavy Metal in Polyurethane by New Digestion Method and ICP-AES (새로운 전처리 방법과 ICP-AES에 의한 폴리우레탄 중의 중금속 분석)

  • Lim, Heon-Sung;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.363-367
    • /
    • 2004
  • A simple and convenient digestion method was developed for the determination of heavy metal in polyurethane sample using only nitric acid in open system without heating. This digestion method had prevented loss of volatile elements of Hg and As and reduced the pretreatment time for the sample digestion. The detection limit is lowered over 10 times than that of microwave digestion method. Recoveries in polyurethane material were 108% for As, 96 ~ 99% for Hg, 102 ~ 103% for Cr, 98 ~ 102% for Pb, 86 ~ 90% for Cd, and 90 ~ 93% for Cu.

Multi - elemental Analysis of Hair by Inductively Coupled Plasma/Mass Spectrometry (유도결합 플라스마 질량분석법에 의한 모발의 다원소 분석)

  • Cha, Myung Jin;Kang, Jun Mo;Park, Chang Joon
    • Analytical Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.335-340
    • /
    • 2002
  • An analytical method has been developed to determine multi-elements in human hair samples by inductively coupled plasma mass spectrometry (ICP-MS). 0.05 g of hair sample was added to the Teflon digestion bomb together with 1.5 mL of nitric acid and an appropriate amount of In as an internal standard. The sample was then decomposed in the microwave digestion system. The hair certified reference material, GBW 09101, was analyzed for the validation of the analytical method. The determined values were in good agreement with the certified values within the uncertainty range.

Analysis of selenium in oil refinery wastewater by hydride generation atomic absorption spectrometry (Hydride Generation Atomic Absorption Spectrometry를 이용한 석유정제폐수중의 selenium 분석)

  • Cheon, Mi-Hee;Kim, Chul;Lee, Hyun-Joo;Kang, Lim-Seok
    • Analytical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.399-406
    • /
    • 2003
  • This study was conducted to find out the analysis condition of selenium(Se) in oil refinery wastewater with a high concentration of Se using the atomic absorption spectrometry with hydride generation system (HG-AAS). From various experiments that reduced Se(VI) to Se(IV), the optimum pretreatment condition was determined to be a sample volume of 10 mL, HCl 10 mL, with a 30 min heating time in a water bath. In oil refinery wastewater, as the concentration of organics and constitution became higher, the recovery rates of Se decreased. Therefore, three acid digestion methods ($HNO_3/HClO_4$ digestion, $KMnO_4$ digestion, and microwave acid digestion) were tested on the recovery rates of Se in reference to the digestion of organics, petroleum and oxidation from organic Se(org.), Se(IV) to Se(VI). The experiment results showed that the average recovery rate of Se was the highest in microwave acid digestion, although all of the digestions were more than 90%. In consequence, the pretreatment procedure of microwave digestion followed by HCl addition was the most suitable for selenium analysis in oil refinery wastewater by using HG-AAS.

Matrix effect on the Determination of Inorganic Priority Pollutants in Sludges (오니 시료중의 무기 Priority Pollutants의 분석 과정에 미치는 매질의 영향)

  • Lee, Huk-Hee;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.297-304
    • /
    • 1998
  • The three analysis methods, EPA method 3050, the method offered by Ministry of Environment in Korea, and modified method corrected in this laboratory, were studied to investigate the effect of matrix on the analysis of inorganic priority pollutants. 7 inorganic priority pollutants(Ni, Cr, Cu, Zn, Pb, Cd, Hg) were spiked to the plating, leather, paper, electric, and dye sludges. Mean recovery of the elements except Hg was 95.5% when the procedure of EPA method was applied. However, recovery by the two other extraction methods showed 11.1% and 27.7%, respectively. Digestions were done by MDS (microwave digestion system) and $HNO_3+HClO_4$ methods. To study organic and inorganic matrix effect, samples were made by adding triethanol amine as a organic matrix and $FeCl_3{\cdot}6H_2O$+$AlCl_3{\cdot}6H_2O$ as a inorganic matrix, respectively. The extracts were analyzed by AAS and HG-AAS. Mean recovery of the elements by the $HNO_3+HClO_4$ procedure, except Hg, gave better result than that of the MDS method. Mean recovery of elements was decreased when organic and inorganic matrices were added in the sludge samples. The procedure of MDS and $HNO_3+HClO_4$ digestion gave higher recoveries than that of direct analysis. In general, the results of the studies showed a significant matrix effect on the inorganic priority pollutants analysis in sludges.

  • PDF

Determination of heavy metals in mainstream smoke by ORS-ICP-MS (ORS-ICP-MS를 이용한 담배 연기의 중금속 성분 분석)

  • Cho, Sung-Eel;Ji, Sang-Un;Hwang, Keon-Joong
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.30 no.1
    • /
    • pp.25-32
    • /
    • 2008
  • In this study, we compared three different pretreatment methods, such as block digestion, microwave digestion and solvent injection, coupled with Octopole Reaction System(ORS)-ICP-MS was used for the quantification of heavy metals in mainstream smoke of 2R4F reference cigarette, and then evaluated those efficiencies in the recovery, repeatability and reproducibility. In all methods, volatile heavy metals, As, showed the highest CV value, and Cd showed the lowest one. However, the solvent injection method showed the most stable recovery rate and CV value of 2.36 %. This method showed also advantages in time-consuming and compatibility with ICP-MS system. This results demonstrate that solvent injection method can be recommended as a superior pretreatment procedure to be able to reduce contaminants and spectral interference as well as loss of the elements interested.

Study on the Pre-treatment for Quantitative Analysis of Mercury in Paper Packaging Materials (지류포장재에서의 수은 정량분석을 위한 전처리 방법 연구)

  • Ko, Seung-Tae;Lee, Tai-Ju;Park, Ji-Hyun;Kim, Hyoung-Jin
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.42 no.5
    • /
    • pp.67-73
    • /
    • 2010
  • Paper packaging materials are essential in protection and transportation of commercial or industrial products. Raw materials for packaging paper production are mainly obtained from various grades of waste paper. For this reason, the recycled fibers from waste paper would probably have possibility of containing heavy metals. This study was focused on the development of optimum pre-treatment method for the quantitative analysis of mercury. The optimum pre-treatment for open digestion system were obtained at the treatment conditions of acid combination with $HNO_3/HCl/H_2O_2$ or $HNO_3/H_2SO_4$ at $80^{\circ}C$. The optimum pre-treatment conditions in closed digestion system were determinated by the acid combination with $HNO_3/HCl/H_2O_2/HF$ in microwave at 320 W for 20 min. The recovery rate in open digestion system was 85~94% and in closed digestion system was indicated as about 100%. Therefore, the closed system is superior than the open system in pre-treatment method for the quantitative analysis of mercury, and the detected mercury contents in the sample of KOCC, AOCC and kraft sack paper were measured below 1 ppm.

A Study of Analytical Method for Trace Metal Ions in Whole Blood and Urine by Inductively Coupled Plasma-Mass Spectrometry using Solid-Liquid Extraction Technique (유도결합 플라스마-질량분석법과 고체-액체 추출법을 이용한 혈액 및 소변중 미량금속의 분석에 관한 연구)

  • Lee, Won;Hur, Young-Hoe;Park, Kyung-Su
    • Analytical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.281-291
    • /
    • 1998
  • An analytical method for the simultaneous measurement of trace Cu, Sn, and Bi in blood and urine has been investigated by Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). Microwave oven was used for the pretreatment of blood samples using nitric acid and hydrogen peroxide in a closedvessel digestion system with 1 mL whole blood for 8 minutes. Amberlite IRC-718 resin was used as a solid phase in solid-liquid extraction technique for the removal of matrix interferences such as Na, S, P, and other polyatomic ion species. Detection limits for Cu, Sn, and Bi by this method were 0.000375 ng/mL, 0.000297 ng/mL, and 0.000174 ng/mL, respectively. Recoveries of 99.1% for Cu, 102.5% for Sn, and 98.4% for Bi were obtained for the standard spiked NIST SRM 955a blood sample. The developed method was applied for whole real blood and urine samples.

  • PDF

Analysis of multi-elemental concentration in hair according to effect of permanent wave and bleaching agents (모발의 탈색 및 퍼머넌트 웨이브 효과에 따른 다-원소금속 성분의 함량 분석)

  • Kim, Jun-Kwang;Ha, Byung-Jo
    • Analytical Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.524-528
    • /
    • 2007
  • Variations of the twenty one metal components (Mg, Al, V, Cr, Co, Sr, Ba, Na, K Mn, Fe, Cu, Zn, As, Hg, Pb, Ca, P, Mo, Cd, Sb) were analyzed in human hair sample by inductively coupled plasma mass spectrometry (ICP-MS). The effect of bleach and permanent wave manipulation on the elemental composition of hair were investigated. It was found that the composition of hair varied with hair bleach and permanent wave. Hair sample was collected from male in the age of thirties. Hair sample (0.05 g) was added to the Teflon digestion bomb together with 1.5 mL of nitric acid and an appropriate amount of In as an internal standard. The sample was then decomposed in the microwave digestion system. In normal hair, the contents of V, Cr, Mn, Fe, Co, Cu, Zn, As, Mo, Cd, Sb and P were increased in permanent wave hair, and Mg, Al, V, Co, Sr, Ba, Na and K were increased in bleached hair. But Mg, Al, Sr, Ba, Hg, Pb, Na, K, and Ca contents were decreased with permanent wave hair, Mn, Fe, Cu, Zn, As, Hg, Pb and Ca contents were decreased with bleached hair.

A Food and Nutrition System Analysis of South Korea

  • Jeffery Sobal;Lee, Soo-Kyung
    • Journal of Community Nutrition
    • /
    • v.5 no.4
    • /
    • pp.209-217
    • /
    • 2003
  • The food and nutrition system is a network of processes linking agriculture, food, eating, nutrition, and health. The system includes a series of nine stages (production, processing, distribution, acquisition, preparation, consumption, digestion, transport, and utilization) and two types of contexts (biophysical and sociocultural). Analysis of whole food and nutrition systems provides information about the structure and processes involved in the complete scope of food and nutrition, assisting in the identification of ″upstream″ influences and ″downstream″ consequences in the system. The current analysis gathered existing data about the food and nutrition system in South Korea from public sources and professional publications, and interpreted that information to consider how different elements of the system contribute to health. The findings revealed that South Korea has substantial domestic food production and processing supplemented by imports, widespread food distribution in markets and a growing number of Korean and Western restaurants, a relatively low percentage of household income spent on food, growing use of new food preparation methods such as microwave ovens, a rice/vegetable/fish based three-meal consumption pattern, few recorded digestive problems, increasing calorie storage as body fat, and a relatively low chronic disease prevalence compared to other developed societies. Examination of the full scope of the food and nutrition system provides a broad perspective using whole system thinking that can identify potential strategies for future research and intervention.