• Title/Summary/Keyword: microwave absorption

Search Result 170, Processing Time 0.02 seconds

EPR Investigation on a Quantitative Analysis of Eu(II) and Eu(III) in LiCl/KCl Eutectic Molten Salt

  • Park, Yong-Joon;Kim, Tack-Jin;Cho, Young-Hwan;Jung, Yong-Ju;Im, Hee-Jung;Song, Kyu-Seok;Jee, Kwang-Yong
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.1
    • /
    • pp.127-129
    • /
    • 2008
  • EPR spectroscopic technique was applied for a quantitative analysis of Eu(II) for a speciation of europium in a LiCl-KCl eutectic melt. By adopting the first absorption line of each isotopes (151Eu and 153Eu), a calibration plot was obtained. The calibration of the EPR intensity shows a good linearity according to the amount of Eu(II). The EPR intensity was identified to increase proportionally with a decrease of the attenuation parameter for EPR microwave power. The fluorescence technique was used qualitatively to find whether either of Eu(II) or Eu(III) ions exists in a molten salt sample. The ICP-AES technique was also adopted to determine the total concentration of europium in the sample, since EPR is only sensitive for detecting the Eu(II) ion. The extent of the reduction of Eu(III) in the LiCl-KCl eutectic melt at 723 K was determined by using this technique.

Evaluation of Total, Water-soluble and Hexavalent Chromium Contents in Construction Materials(Concretes, Cements)

  • Choi, In-Ja;Yoon, Chung-Sik;Choi, Sang-Jun
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.6
    • /
    • pp.497-501
    • /
    • 2007
  • The objective of the study is to determine the contents of total chromium, water-soluble chromium and hexavalent chromium in cements and concretes specimens taken from manufacturing or construction sites. Chromate is an allergen that is widespread in the environment and is richly contained in cements. Metals were extracted with microwave oven and analyzed by atomic absorption spectrometer. Hexavalent chromium was analysed by ion chromatography. The concentrations of total chromium, water-soluble chromium and hexavalent chromium in cements were $36.02{\sim}108.01,\;15.95{\sim}89.01\;and\;26.77{\sim}89.61\;mg/kg$, respectively. The concentrations of hexavalent chromium in cements were higher than 2 mg/kg, a maximum value recommended in Northern European Countries. The concentrations of total chromium, water-soluble chromium and hexavalent chromium in concretes were $17.44{\sim}76.25,\;0.98{\sim}17.71\;and\;ND{\sim}24.13\;mg/kg$, respectively. Especially Hexavalent chromium was detected only from concrete specimens from construction sites. It is oxidized or reduced status by environmental condition or surrounding materials.

Electron Spin Resonance of an Irradiated Single Crystal of L-alanine (인체 등가물질에 대한 방사선 조사)

  • 한영환;권수일
    • Progress in Medical Physics
    • /
    • v.4 no.1
    • /
    • pp.41-53
    • /
    • 1993
  • The electron spin resonanec of sigle crystals of L-alanine have been observed at T=300K, 100K and analyzed for different orieantations of the crystal in the magnetic field and at microwave frequency X-band. The stable free radical profuced by the irradiation is proved to be of the form CH$_3$CHR, where R is a group which has no nuclei with detectable coupling A notable dependence on temperature of the absorption was observed in the range from 1100K to 2l0K. It was concluded that the reorietation of the methy group of the radical H$_3$CCHR is quenched at low temperature.

  • PDF

Numerical Analysis of Loss Power Properties in the Near-Field Electromagnetic Wave Through A Microstrip Line for Multilayer Magnetic Films with Different Levels of Electrical Conductivity

  • Lee, Jung-Hwan;Kim, Sang-Woo
    • Journal of Magnetics
    • /
    • v.13 no.3
    • /
    • pp.92-96
    • /
    • 2008
  • There are few reports of high frequency loss behavior in the near-field for magnetic films with semiconducting properties, even though semiconducting magnetic materials, such as soft magnetic amorphous alloys and nanocrystalline thin films, have been demonstrated. The electromagnetic loss behavior of multilayer magnetic films with semiconducting properties on the microstrip line in quasi-microwave frequency band was analyzed numerically using a commercial finite-element based electromagnetic solver. The large increase in the absorption performance and broadband characteristics of the semiconducting/insulating layer magnetic films examined in this study were attributed to an increase in the loss factor of resistive loss. The electromagnetic reflection increased significantly with increasing conductivity, and the loss power deteriorated significantly. The numerical results of the magnetic field distribution showed that a strong radiated signal on the microstrip line was emitted with increasing conductivity and decreasing film thickness due to re-reflection of the radiated wave from the surface of the magnetic film, even though the emitted levels varied with film thickness.

Photocatalytic Activity of $TiO_2$ Powder with an Oxygen Deficiency in the Visible-Light Region (산소 결함형 $TiO_2$ 분말의 가시광에 대한 광촉매 활성)

  • Yang, Chun-Hoe
    • Journal of the Korean Applied Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • It prepared the $TiO_2$ powder which has photo-catalytic activity in the visible-light by the wet process with titanium oxysulfate. The titanium $dioxide(TiO_2)$ by the wet process creates a new absorption band in the visible light region, and is expected to create photocatalytic activity in this region. Anatase $TiO_2$ powder which has photocatalytic activity in the visible light region, is treated using microwave and radio-frequency(RF) plasma. But, the $TiO_2$ powder for the visible light region, which also can be easily produced by wet process. The wet process $TiO_2$ absorbed visible light between 400nm and 600nm, and showed a high activity in this region, as measured by the oxidation removal of aceton from the gas phase. The AH-380 sample appears the yellow color to be strong, the catalytic activity in the visible ray was excellent in comparison with the plasma-treated $TiO_2$. The AH-380 $TiO_2$ powder, which can be easily produced on a large scale, is expected to have higher efficiency in utilizing solar energy than the plasma-treated $TiO_2$ powder.

A Study on Electromagnetic Interference Shielding Effectiveness of the Metal Powders and Nano Carbon black /Fiber Reinforced Epoxy composites (메탈 파우더와 나노 카본 블랙/섬유강화 복합재료의 전자파 차폐효과에 관한 연구)

  • Han Gil-Young;Kim Jin-Seok;Ahn Dong-Gyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.8 s.185
    • /
    • pp.100-107
    • /
    • 2006
  • The objective of this research is to investigate the electromagnetic interference(EMI) shielding characteristics of fiber reinforced composites. We fabricated glass and carbon fiber reinforced composites filled with metal powder and nano carbon black. The measurements of shielding effectiveness(SE) were carried out frequency range 300MHz - 1GHz for commercial purposes such as electric or telecommunication devices. The return loss and loss due to absorption were also measured as a function of frequency in the micro wave(300MHz-1GHz) region. It is observed that the SE of the composites is the frequency dependent, increase with the increases in filler loading. The Mg metal powder filled composite showed higher SE compared to that of carbon black. The Mg metal powder/epoxy composite was shown to exhibit up to 40dB of SE. The results indicates that the composite having higher filler loading can be used for the purpose of EMI shielding as well as for some microwave applications.

Quality Characteristics of Jochung by Analyzing Traditional Manufacturing Process (조청의 전통제조공정 분석을 통한 품질특성)

  • Yang, Hye-Jin;Son, Ji-Hye;Lee, Yang-Soon;Ryu, Gi-Hyung
    • Food Engineering Progress
    • /
    • v.13 no.4
    • /
    • pp.235-242
    • /
    • 2009
  • The purpose of this study is to establish fundamental research data for quality characteristics of Jochung by analyzing traditional manufacturing process. Two different processed rices (non-glutinous rices cooked by steaming and using an electronic rice cooker) were compared in terms of water solubility index (WSI), water absorption index (WAI), paste viscosity, reducing suger content, solid content, and dextrose equivalent over soaking time. Reducing sugar content increased for the soaked non-glutinous rice, steamed sample and microwaved sample. After 4 hr, the WSI decreased as the soaking time increased. However, there was no significant difference between WAI of the raw non-glutinous rice and the soaked non-glutinous rice. As soaking time increased, paste and breakdown viscosity increased significantly. Rice was prepared by soaking in water for 12 hr followed by the saccharification time (4, 8, or 12 h) for manufacturing Jochung. The solid content and reducing sugar content of the Jochung increased as the soaking time increased. Reducing sugar content and dextrose equivalent of Jochung from steamed rice (cooked hard) were higher than those from microwaved ones. The amount of reducing sugar and dextrose equivalent was highest in Jochung from steamed rice cooked hard (saccarification for 12 hr), with 59.40${\pm}$0.11% and 76.99${\pm}$1.78, respectively. In conclusion, the highest quality characteristics were obtained in Jochung manufactured with non-glutinous rice soaked for 12 hr followed by sacharification for 12 hr.

The Study of Standardization of Temperature Distribution of Interstitial Hyperthermia -In Phantoms and Living cat's brain tissue (Normal Tissue)- (915 MHz 극초단파 자입온열시 온도분포 적정화에 관한 연구 -조직등가물 및 가묘대뇌를 대상으로-)

  • Kyoung Hwan Koh;Cho Chul Koo;Park Young Hwan;Yoo Seong Yul;Kim Jong Hyun;Lee Seung Hoon
    • Radiation Oncology Journal
    • /
    • v.8 no.1
    • /
    • pp.7-15
    • /
    • 1990
  • The ultimate objective of our experiment is to obtain the precise distribution of temperature in malignant tumors occurring in cerebral parenchyme of human beings when we will carry out interstitial hyperthermia in the near future. To achieve this purpose, first of all, it is necessary to make an attempt at performing interstitial hyperthermia in vivo under the similar condition of human beings. Therefore, we chose cats as materials much alike tissue characteristics of human beings. Moreover, it is also necessary to get the basic data from dynamic phantom in order to standardize and compare results obtained from interstitial hyperthermia carried out in cats. By having performed these experiments we got the following results. 1) On doing interstitial hyperthermia with 915 MHz microwave, the possible treated volume was 2 cm by 2 cm by 6 cm according to $50\%$ specific absorption rate (SAR). 2) The distribution of temperature within non-circulated static phantom was much the same as power density in air, but we observed that the temperature, within $5\~10$ minutes, rose to more higher than $55^{\circ}C$ not measured with Ga-As fiberoptic thermistor which was not impeded by microwave after performing interstitial hyperthermia. 3) Within dynamic phantom in which normal saline was circulating, temperature reached steady state which was maintained for more than 45 minutes through transit period in 5 minutes after starting interstitial hyperthermia. 4) When we interrupted circulation in the dynamic phantom, we observed that temperature rose to the same level as in the static phantom. 5) We could carry out interstitial hyperthermia safely when we used the generating power below 5 watts. Abrupt interruption of circulation caused a rapid increase in temperature. Times taking to rise to maximum $55^{\circ}C$ were 15.2 minutes (SE 0.4),9.7 minutes (SE 0.3), and 6.3 min-utes (SE 0.4) respectively with generating powers of 5,10, and 15 watts.

  • PDF

Effects of Annealing Temperature on Electromagnetic Wave Absorption Characteristics in FeCuNbSiB Alloy Flakes/Polymer Composite Sheets (FeCuNbSiB 합금 박편/폴리머 복합 시트의 전자파 흡수 특성에 미치는 자성분말 어닐링 온도의 영향)

  • Noh, Tae-Hwan;Lee, Tae-Gyu
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.5
    • /
    • pp.198-204
    • /
    • 2007
  • The effects of annealing temperature on electromagnetic wave absorption characteristics in $Fe_{73.5}Cu_1Nb_3Si_{15.5}B_7$ (at%) alloy flakes/polymer composite sheets available for quasi-microwave band have been investigated. The composite sheet including the magnetic flakes annealed at $425{\sim}475^{\circ}C$ for 1 h exhibited highest power loss in the GHz frequency range as compared with the sheets composed of the alloy flakes annealed at higher temperature than $475^{\circ}C$ or in as-milled state. Moreover the imaginary part of complex permeability had largest value in the GHz frequency range for the sheets including the flakes annealed at $425{\sim}475^{\circ}C$. The large value of power loss of the sheets including the magnetic flakes annealed at $425{\sim}475^{\circ}C$ was attributed to the high imaginary part of the complex permeability. However, because of its large transmission parameter $S_{21}$, the composite sheet having the magnetic flakes annealed at $525^{\circ}C$ showed low power loss.

An Experimental Study on the Application of Measuring Method of Water Content for Quality Control of Concrete (콘크리트 품질관리를 위한 단위수량 측정 기법의 적용성에 관한 실험적 연구)

  • Kim, Yong-Ro;Choi, Il-Ho;Jung, Yang-Hee;Lee, Do-Bum
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.2
    • /
    • pp.179-188
    • /
    • 2007
  • Recently, the concern on the receipt of poor ready-mixed concrete in the construction field and the durability of concrete has been increased. Based on the such background, a large number of measuring methods of water content for fresh concrete have been developed and enforced in a developed country. In this study, to investigate practicality for quality control of ready-mixed concrete among various water content measurement techniques, microwave range method, air meter method and capacitance measurement method as measuring methods of water content were selected. Then, it was evaluated estimating performance of water content according to the change of binder types, fine aggregate types, absorption ratio, water content and water-binder ratio in series I and II. Also, it was examined influence on error occurrence of water content according to change of properties of used materials in series III. Finally, based on this study, it was proposed fundamental data to utilize measurement technique of water content to quality control of ready-mixed concrete in construction field.