• Title/Summary/Keyword: microscopy analysis

Search Result 2,696, Processing Time 0.029 seconds

Study of the Microstructural Evolution of Tempered Martensite Ferritic Steel T91 upon Ultrasonic Nanocrystalline Surface Modification

  • He, Yinsheng;Yang, Cheol-Woong;Lee, Je-Hyun;Shin, Keesam
    • Applied Microscopy
    • /
    • v.45 no.3
    • /
    • pp.170-176
    • /
    • 2015
  • In this work, various electron microscopy and analysis techniques were used to investigate the microstructural evolution of a 9% Cr tempered martensite ferritic (TMF) steel T91 upon ultrasonic nanocrystalline surface modification (UNSM) treatment. The micro-dimpled surface was analyzed by scanning electron microscopy. The characteristics of plastic deformation and gradient microstructure of the UNSM treated specimens were clearly revealed by crystal orientation mapping of electron backscatter diffraction (EBSD), with flexible use of the inverse pole figure, image quality, and grain boundary misorientation images. Transmission electron microscope (TEM) observation of the specimens at different depths showed the formation of dislocations, dense dislocation walls, subgrains, and grains in the lower, middle, upper, and top layers of the treated specimens. Refinement of the $M_{23}C_6$ precipitates was also observed, the size and the number density of which were found to decrease as depth from the top surface decreased. The complex microstructure and microstructural evolution of the TMF steel samples upon the UNSM treatment were well-characterized by combined use of EBSD and TEM techniques.

Study on the Friction Force Microscopy Analysis of Diamond-like Carbon Films according to the Annealing Temperature (다이아몬드상 카본박막의 열처리 온도에 따른 Friction Force Microscopy 분석에 관한 연구)

  • Choi, W.S.;Cho, Y.;Park, Y.S.;Jeon, Y.;Heo, J.;Chung, I.;Hong, B.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.166-167
    • /
    • 2005
  • 본 연구에서는 RF 플라즈마 화학기상증착 장비를 사용하여 동일조건에서 합성된 100 nm 두께의 DLC박막을 RTA 장비를 사용하여 $N_2$ 분위기로 여러 가지 온도에서 ($300\sim900^{\circ}C$) 후열처리된 DLC 박막들의 마찰특성 변화를 AFM (Atomic Force Microscopy)의 FFM (Friction Force Microscopy) 모드를 사용하여 관찰하였다.

  • PDF

A Study of the Etched ZnO Thin Films Surface by Reactive Ion in the Cl2/BCl3/Ar Plasma (Cl2/BCl3/Ar 플라즈마에서 반응성 이온들에 의해 식각된 ZnO 박막 표면 연구)

  • Woo, Jong-Chang;Kim, Chang-Il
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.10
    • /
    • pp.747-751
    • /
    • 2010
  • In the study, the characteristics of the etched Zinc oxide (ZnO) thin films surface, the etch rate of ZnO thin film in $Cl_2/BCl_3/Ar$ plasma was investigated. The maximum ZnO etch rate of 53 nm/min was obtained for $Cl_2/BCl_3/Ar$=3:16:4 sccm gas mixture. According to the x-ray diffraction (XRD) and atomic force microscopy (AFM), the etched ZnO thin film was investigated to the chemical reaction of the ZnO surface in $Cl_2/BCl_3/Ar$ plasma. The field emission auger electron spectroscopy (FE-AES) analysis showed an elemental analysis from the etched surfaces. According to the etching time, the ZnO thin film of etched was obtained to The AES depth-profile analysis. We used to atomic force microscopy to determine the roughness of the surface. So, the root mean square of ZnO thin film was 17.02 in $Cl_2/BCl_3/Ar$ plasma. Based on these data, the ion-assisted chemical reaction was proposed as the main etch mechanism for the plasmas.

Fractographic Analysis of Ceramic Composites by Transmission Electron Microscopy using Surface Replication Technique (표면복제법을 이용한 세라믹 복합재료 파괴현상의 투과전자현미경 분석)

  • Jun, Hyeung-Woo;Kim, Gyeung-Ho;Kim, Byung-Ho
    • Applied Microscopy
    • /
    • v.26 no.4
    • /
    • pp.447-456
    • /
    • 1996
  • Fracture surfaces of materials contain useful information ranging from crack path to the mechanism of fracture. Since limitation of electron transparency requires a sample in the form of thin foil for TEM observations, it is impossible to extract such information directly from the fracture surfaces. In this study, the method of surface replication from the ceramic fracture surface is employed to characterize the process of crack propagation in ceramic matrix composites using TEM analysis. The surface replica from the fracture surface in ceramic materials provides detailed surface morphology and more importantly, loosened particles on the fracture surface are collected. Electron diffraction and chemical composition analyses of these particles reveal crack path in the specimen. Furthermore, one can determine the mode of fracture by observing the fracture surface morphology from the image of replica. Two examples are given to illustrate the potential of the surface replication technique. In the first example, apparent toughness increase in $B_{4}C-Al$ composites at high strain rate is investigated by surface replication to elucidate the mechanism of fracture at different strain rates. The polytypes of SiC formed during the sintering of SiC-AlN composite and their effect on the fracture behavior of SiC-AlN composite are analyzed in the second example.

  • PDF

Analysis of BNNT(Boron Nitride Nano Tube) synthesis by using Ar/N2/H2 60KW RF ICP plasma in the difference of working pressure and H2 flow rate

  • Cho, I Hyun;Yoo, Hee Il;Kim, Ho Seok;Moon, Se Youn;Cho, Hyun Jin;Kim, Myung Jong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.179-179
    • /
    • 2016
  • A radio-frequency (RF) Inductively Coupled Plasma (ICP) torch system was used for boron-nitride nano-tube (BNNT) synthesis. Because of electrodeless plasma generation, no electrode pollution and effective heating transfer during nano-material synthesis can be realized. For stable plasma generation, argon and nitrogen gases were injected with 60 kW grid power in the difference pressure from 200 Torr to 630 Torr. Varying hydrogen gas flow rate from 0 to 20 slpm, the electrical and optical plasma properties were investigated. Through the spectroscopic analysis of atomic argon line, hydrogen line and nitrogen molecular band, we investigated the plasma electron excitation temperature, gas temperature and electron density. Based on the plasma characterization, we performed the synthesis of BNNT by inserting 0.5~1 um hexagonal-boron nitride (h-BN) powder into the plasma. We analysis the structure characterization of BNNT by SEM (Scanning Electron Microscopy) and TEM (Transmission Electron Microscopy), also grasp the ingredient of BNNT by EELS (Electron Energy Loss Spectroscopy) and Raman spectroscopy. We treated bundles of BNNT with the atmospheric pressure plasma, so that we grow the surface morphology in the water attachment of BNNT. We reduce the advancing contact angle to purity bundles of BNNT.

  • PDF

Study on the Thermal Analysis of Dyed Hair Depending on the Brightness Level (명도 차이에 따른 염색모발의 열분석에 관한 연구)

  • Kim, Moon-Sun;Lee, Gui-Young;Choi, Eun-Young;Kim, Dong-Heui;Chang, Byung-Soo
    • Applied Microscopy
    • /
    • v.38 no.3
    • /
    • pp.159-165
    • /
    • 2008
  • Morphological and physicochemical changes of a woman's virgin hair treated with various dye depths were investigated by using scanning electron microscopy and thermal analyzer. With the hair treated with the dye of the high brightness level, the speed of weight decrease was slower than compared with thermal analysis weight of a normal hair sample. We confirmed that the moisture content and protein composition of hair were changed depending on level depth of coloring agent. Moreover oxidative residues and dye molecules penetrated into the hair cause chemical changes of hair structure. As a result, the heat reaction speed of hair treated with high level coloring agent was made slower than normal hair.

Failure Analysis of Austenitic Stainless Steel Pipe (오스테나이트계 스테인레스 강관에서의 손상해석에 관한 연구)

  • 이상율;이종오;이주석;조경식;조종춘;이보영
    • Journal of Welding and Joining
    • /
    • v.11 no.1
    • /
    • pp.21-32
    • /
    • 1993
  • A cracking failure of a austenitic stainless steel elbow in a naphtha cracking line in a petrochenmical plant occurred, resulting in leakage of organic compound flowing inside the elbow. Due to the failure, emergency shutdown of the plant was enforced to repair the troubled part of the line. The repair cost as well as production loss during the unscheduled plant shutdown has cost the company a great amount of financial loss. In this studies, a failure analysis of the cracked elbow was performed using NDT, chemical analysis, microstructural analysis including optical microscopy as well as scanning electron microscopy with EPMA, mechanical testings such as tensile testing, hardness testing and Charphy impact test fractography. The results indicated that several problems such as a welding defect and presence of a detrimental phase which was found to be relate to improper postforming heat treatment process was identified and the failure was concluded to be due to a low temperature embrittlement of the defect-containing elbows.

  • PDF

Crystal Structure Analysis by Texture Electron Diffraction Pattern (Texture Electron Diffraction Pattern에 의한 결정구조 해석)

  • Lee, Su-Jeong;Jou, Hyeong-Tae;Kim, Youn-Joong;Moon, Hi-Soo
    • Applied Microscopy
    • /
    • v.32 no.3
    • /
    • pp.185-193
    • /
    • 2002
  • The works of texture electron diffraction patterns for crystal structure analysis are written in Russian or introduced briefly in books written in English, which makes it difficult to be understood. In addition to working out the equations, vector theory corrects some errors included in the established formulas for texture electron diffraction patterns.

Focused Ion Beam-Based Specimen Preparation for Atom Probe Tomography

  • Lee, Ji Yeong;Ahn, Jae-Pyoung
    • Applied Microscopy
    • /
    • v.46 no.1
    • /
    • pp.14-19
    • /
    • 2016
  • Currently, focused ion beams (FIB) are widely used for specimen preparation in atom probe tomography (APT), which is a three-dimensional and atomic-scale compositional analysis tool. Specimen preparation, in which a specific region of interest is identified and a sharp needle shape created, is the first step towards successful APT analysis. The FIB technique is a powerful tool for site-specific specimen preparation because it provides a lift-out technique and a controllable manipulation function. In this paper, we demonstrate a general procedure containing the crucial points of FIB-based specimen preparation. We introduce aluminum holders with moveable pin and an axial rotation manipulator for specimen handling, which are useful for flipping and rotating the specimen to present the backside and the perpendicular direction. We also describe specimen preparation methods for nanowires and nanopowders, using a pick-up method and an embedding method by epoxy resin, respectively.