• 제목/요약/키워드: microleakage

검색결과 261건 처리시간 0.023초

다양한 복합레진 시스템의 변연 누출도 (MICROLEAKAGE OF VARIOUS COMPOSITE RESIN SYSTEMS)

  • 김인수;민경산;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제28권2호
    • /
    • pp.127-133
    • /
    • 2003
  • The object of this study was to compare the microleakage between various composite resin systems of multistep, one-bottle, and self-etching systems using electrical conductivity. After making class V cavities ($4{\times}3{\times}1.5{\;}mm$ around CEJ), they were bulk filled with three kinds of resins of A3. Teeth were storaged in a saline solution for one day, after then, they were finished and polished using Sof-Lex system. Another stress of thermocycling was made for 500 times from $5^{\circ}{\;}to{\;}55^{\circ}C$ with each dwelling time of 10 seconds. Electrical conductivity (microamphere, $\mu\textrm{A}$) was checked four times: before and after cavity preparation, after filing, after thermocycling. One-way ANOVA and 95% Scheffe Post Hoc test was used for checking any statistical difference among groups. Another 95% Paired Samples T-test was also used for estimating any significant difference within group after cavity filling or thermocycling. The results were as follows: 1 Every specimen showed various range of microleakage after filing. There was, however, no difference between composite resin systems. 2. All composite resin systems showed marked increase in microleakage with a thermocycling (p<0.05), there was, however, no difference between composite resin systems. 3. Although there was no significant difference between groups (p=0.078), one-bottle and self-etching systems seemed to be unstable than multistep system. Within the limits of this study, it was concluded that much more consideration should be needed when using thermally unstable one-bottle and self-etching systems that have multi-advantages from simplified step. More studies will be needed to solve these kinds of problems.

Coronal microleakage of four temporary restorative materials in Class II-type endodontic access preparations

  • Yun, Sang-Mi;Karanxha, Lorena;Kim, Hee-Jin;Jung, Sung-Ho;Park, Su-Jung;Min, Kyung-San
    • Restorative Dentistry and Endodontics
    • /
    • 제37권1호
    • /
    • pp.29-33
    • /
    • 2012
  • Objectives: The purpose of this study was to evaluate the microleakage of 4 temporary materials in teeth with Class II-type endodontic access preparations by using a glucose penetration model. Materials and Methods: Glucose reaction test was performed to rule out the presence of any reaction between glucose and temporary material. Class II-type endodontic access preparations were made in extracted human premolars with a single root (n = 10). Each experimental group was restored with Caviton (GC), Spacer (Vericom), IRM (Dentsply-Caulk), or Fuji II(GC). Microleakage of four materials used as temporary restorative materials was evaluated by using a glucose penetration model. Data were analyzed by the one-way analysis of variance followed by a multiplecomparison Tukey test. The interface between materials and tooth were examined under a scanning electron microscope (SEM). Results: There was no significant reaction between glucose and temporary materials used in this study. Microleakage was significantly lower for Caviton and Spacer than for Fuji II and IRM. SEM observation showed more intimate adaptation of tooth-restoration interfaces in Caviton and Spacer than in IRM and Fuji II. Conclusions: Compared to IRM and Fuji II, Caviton and Spacer can be considered better temporary sealing materials in Class II-type endodontic access cavities.

컴포머의 수화팽창에 관한 연구 (A STUDY ON THE HYGROSCOPIC EXPANSION OF COMPOMER)

  • 박경진;김종수;권순원
    • 대한소아치과학회지
    • /
    • 제29권1호
    • /
    • pp.11-18
    • /
    • 2002
  • 컴포머는 산성화된 이중 기능성 레진 단량체와 fluoro-alumine-silicate 글라스 입자로 구성되어 초기에는 복합레진과 같이 광원에 의해 중합되며 이차적으로 구강내 수분을 흡수하면서 글라스 아이오노머 시멘트와 유사한 산-염기 반응으로 중합되고 이의 결과로 물성의 저하없이 지속적으로 불소를 유리한다고 보고되고 있으며, 물분자를 흡수하여 수화됨에 따라 서서히 팽창하여 광중합시의 수축을 보상하고 미세누출을 최소화할 수 있다고 보고되고 있으나 아직 확립되어 있지는 않은 상태이다. 이에 본 연구는 현재 소아치과 임상에서 많이 사용되고있는 컴포머를 대상으로 초기의 중합수축에 의한 미세누출이 수화 평창에 의해 감소되는지 여부를 복합레진과 비교하기 위하여 5급 와동의 교합면측과 치은면측의 미세누출양을 1일과 30일 후에 측정한 결과 30일 후 컴포머의 치은면측에서 현저히 낮은 미세누출을 보였다.

  • PDF

법랑질 접착에 대한 습윤 효과 (EFFECT OF WETNESS ON THE ENAMEL BONDING)

  • 고근호;조영곤;진철희;유상훈;김종욱;박병철;기영재;최희영;김종진
    • Restorative Dentistry and Endodontics
    • /
    • 제29권3호
    • /
    • pp.205-211
    • /
    • 2004
  • This study evaluated the microleakage and interfacial gap between enamel and composite resin under the dry and wet condition of the enamel surface. V shaped class 5 cavities were prepared on the occlusal portion of extracted human molars. Samples were divided into three groups:D group (air dry for 10-15s), BD group (blot dry with moist cotton pellet), and DR group (air dry for 10-15s and rewet with Aqua-Prep F for 20s), Cavities were filled using Aelitefil composite resin after applied One-Step. Microleakage was tested by 2% methylene blue dye solution and the data were statistically analysed by Kruskal-Wallis test and Mann-Whitney test. Also Enamel-resin interface was observed under SEM. Group BD showed statistically lower microleakage than group D (p < 0.05). but there was no statistically significant difference between group BD and DR (p > 0.05). At the enamel-resin interface, group D showed the gap of $2{\;}{\mu}m$ thickness, but group BD and DR showed close adaptation. In conclusion, the use of blot dry and rewetting agent (Aqua-Prep F) resulted in decreased microleakage and improved adhesion between enamel and resin when using One-Step.

제 5급와동에서 광중합 그래스 아이오노머 수복물의 미세변연누출에 관한 연구 (THE MICROLEAKAGE OF LIGHT-CURED GLASS LONOMER RESTORATIVE MATERIALS IN CLASS V CAVITIES)

  • 조인식;박준일;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.304-315
    • /
    • 1998
  • The purpose of this study was to evaluate the microleakage of light cured glass ionomer restorative materials in class 5 cavities. In this in vitro study, class 5 cavities were prepared on buccal and lingual surfaces of forty extracted human premolars and molars on cementum margin. These specimen were randomly divided into four groups of 10 each : Group 1 was Fugi II (control), Group 2 was Fugi II LC, Group 3 was Vitremer, and Group 4 was Dyract. Group 2 was also divided once more into 2 groups of 5 each : Group 2-1 was pretreated with dentin conditioner and Group 2-2 was not. All teeth were restored according to the manufacturer's instructions. After 500 thermocycling between $5^{\circ}C$ and $55^{\circ}C$, the 40 teeth were placed in 2 % Methylene blue dye for 24hr, then rinsed with tab water. The specimen were embedded in clear resin, then sectioned buccolingually through the center of restoration with a low speed diamond saw. The dye penetration on each of the specimen were then observed with a stereomicroscope at 20. The results of the study were statistically analyzed using the Student-Newman-Keuls Methods and the Mann-Whitney Rank Sum Test. Tooth restorative interfaces were evaluated using SEM analysis. Results were as follows, 1. Compared to conventional glass ionomer restoratioqs, all light cured glass ionomer restorations were fairly resistant to microleakage (P<0.05). 2. Groups 3 (Vitremer) and Group 4 (Dyract) were found to be the most resistant, Group 2 (Fugi II LC) fairly resistant, and Group 1 (Fugi II) least resistant to microleakage(P<0.05). 3. No significant differences were found between Group 2-1 and Group 2-2 (P>0.08). 4. With the backscattered SEM analysis, the degrees to which tight bonding occurred were also observed in all the groups except for Group 1. Group 4 showed the highest degree of tight bonding than any other materials used in this study.

  • PDF

Evaluation of Shear Bond Strength and Microleakage of Self-adhesive Giomer

  • Gwangsuk Kim;Juhyun Lee;Haeni Kim;Howon Park
    • 대한소아치과학회지
    • /
    • 제50권4호
    • /
    • pp.434-442
    • /
    • 2023
  • This study was aimed to evaluate the bonding performance of a self-adhesive giomer and compare it to a conventional flowable composite resin with regard to shear bond strength and microleakage in enamel and dentin. Healthy human premolars extracted for orthodontic treatments were used in the study. For shear bond strength tests, enamel and dentin specimens were prepared for the study group with self-adhesive giomer and for the control group with conventional flowable composite resin with a 5th-generation adhesive system. A universal testing machine was used to measure the shear bond strength. For the microleakage tests, specimens were immersed in a 2% methylene blue solution for 24 hours, cut into sections, and evaluated with a stereomicroscope for the extent of dye penetration. The results of the study showed no statistically significant difference in shear bond strength between the self-adhesive giomer and the conventional flowable composite resin in enamel (p = 0.091). On the contrary, in dentin, the self-adhesive giomer showed significantly lower shear bond strength (p < 0.0001). The microleakage of the self-adhesive giomer was significantly higher than that of the conventional flowable composite resin (p = 0.002). Self-adhesive giomer is considered useful for restoring small cavities at the enamel level of pediatric patients by reducing chair time with the advantage of a simple bonding process. However, as the study was conducted in a laboratory setting, further research in a clinical environment is deemed necessary.

The comparison of microleakage on intracoronal restoration after non-vital bleaching

  • Jung, Jae-Eun;Lee, Hee-Joo;Hur, Bock
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.584.2-584
    • /
    • 2001
  • The purpose of the present study were to evaluate microleakage of a fourth generation dentin-bonding agent following a walking bleaching treatment, to determine the effect of temporary postbleaching dressing with calcium hydroxide on microleakage and to investigate the effect of delayed intracoronal restoration on micro leakage. Forty extracted non-carious incisors were selected and conventional root canal treatment was performed. The teeth were randomly divided into 4 groups of 10 specimens each.(omitted)

  • PDF

제V급 복합레진 수복물의 표면전색이 미세변연누출에 미치는 효과 (The Effect of Surface Sealing on the Microleakage of Class V Composite Resin Restorations)

  • 윤연희;현홍근;김영재;김정욱;장기택;이상훈;김종철;한세현
    • 대한소아치과학회지
    • /
    • 제34권3호
    • /
    • pp.359-369
    • /
    • 2007
  • 본 연구는 다양한 순환 및 시효 조건 하에서 제V급 복합레진 수복물의 표면전색이 미세변연누출에 미치는 효과에 대해 알아보고자 하였다. 100개의 건전한 소구치의 협면에 제V급 와동을 형성하고 제조사의 지시대로 광중합형 복합레진으로 수복하였다. 무작위로 나누어 표면전색을 시행하지 않는 I군과 표면을 산부식 후 표면전색을 시행한 II군으로 설정한 후 열순환(thermocycling)을 하였다. 각 군에서 하위군(A군= 열순환 외 다른 시효조건이 없는 군, B군=칫솔질군, C군=부하순환군, D군=칫솔질과 부하순환을 모두 시행한 군, E군=6개월간 증류수에 보관한 군)으로 나누어 각각에 맞는 시효조건을 시행하였다. 2% methylene blue 용액에 침윤시켜 변연의 미세누출정도를 평가하여 다음과 같은 결과를 얻었다. 1. 표면전색을 시행하지 않은 군의 교합변연과 치은변연에서 시효조건에 따른 미세누출의 유의한 차이는 보이지 않았다(p>0.05). 2. 표면전색을 시행한 군의 교합변연에서는 시효조건에 따른 미세누출의 유의한 차이가 없었다(p>0.05). 3. 표면전색을 시행한 군의 치은변연에서는 부하순환이나 6개월간 증류수에서 보관하는 시효과정을 거친 군에서 미세누출이 유의하게 크게 나타났다(p<0.05). 4. 시효조건이 없는 군과 칫솔질군의 경우, 표면전색을 시행한 군이 표면전색을 시행하지 않은 군에 비해 유의하게 적은 미세누출결과를 보였다(p<0.05). 5. 부하순환을 시행한 군과 6개월간 증류수에서 보관한 경우에는 표면전색을 시행한 군과 표면전색을 시행하지 않은 군 사이에 미세누출의 차이가 있었지만 유의차가 없었다(p>0.05). 따라서 이 연구의 결과는 변연부분의 미세간격으로 침투한 표면전색제가 처음에는 미세누출을 감소하는데 효과를 보여주었으나, 교합시 교두가 휘어져서 생기는 응력과 장기간의 수분흡수로 인한 변화를 견디기에 불충분함을 보여주었다.

  • PDF

심미적 포스트 코어의 종류에 따른 미세누출에 관한 연구 (Microleakage of endodontically treated teeth restored with three different esthetic post and cores)

  • 박지근;박지만;박은진
    • 대한치과보철학회지
    • /
    • 제47권1호
    • /
    • pp.53-60
    • /
    • 2009
  • 연구목적: 오늘날 심미적 요구의 증가로 치아색 포스트 코어에 대한 많은 관심이 모아지고 있으며 다양한 연구가 진행 중이다. 현재 화이버 포스트 (ParaPost fiber White, Coltene Whaledent, Cuyahoga Falls, USA), 지르코니아 포스트 (CosmoPost, Ivoclar Vivadent, Schann, Germany) 등에 관한 논문은 다소 나와 있으나 요즘 여러 분야에서 관심을 받고 있는 CAD/CAM (computer-aided design/computer-aided manufacturing) 방식으로 지르코니아를 가공한 절삭형 지르코니아 포스트 코어에 대한 연구는 많지 않은 실정이다. 이 연구의 목적은 CAD/CAM을 이용한 지르코니아를 비롯하여 근관치료된 치아에서 사용된 세 가지 다른 치아색 포스트 코어에 대해 미세누출 (microleakage)을 비교해 보는 것이다. 연구 재료 및 방법: 발치된 건전한 상악 절치 27개를 채택하여 백악법랑질경계 (CEJ)에서 절단하여 근관치료를 시행하고, 세군 (각 9개)으로 나누었다. 각군들은 화이버 포스트와 콤포짓트 레진 코어 (1군), 지르코니아 포스트와 열가압형 세라믹 코어 (2군), CAD/CAM 절삭형 지르코니아 포스트 코어 (3군)로 수복하였다. $5-55^{\circ}C$ 1000회 열순환 처리 (thermocycling)를 시행하고, 2% 메틸렌 블루로 $37^{\circ}C$에서 24시간 염색하였다. 치아장축과 평행하게 순설방향으로 절단하여 미세누출을 현미경과 컴퓨터 프로그램을 사용하여 분석을 하였다. 데이터는 one-way ANOVA와 Scheffe's multiple range test (${\alpha}=0.05$)로 분석하였다. 결과: 모든 군에서 미세누출을 보였으며, 지르코니아 포스트와 열가압형 세라믹 코어군 (2군)에서 치근계면 입구에서는 다소 많은 미세누출을 보였으나 포스트 끝에 이르러서는 거의 미세누출이 없는 결과를 보였다. 화이버 포스트와 콤포짓트 레진 코어군 (1군)과CAD/CAM 절삭형 지르코니아 포스트 코어군 (3군)에서는 부위별로 균등한 미세누출을 보였다. 결론: 화이버 포스트와 콤포짓트 레진 코어군, 지르코니아 포스트와 열가압형 세라믹 코어군, CAD/CAM 절삭형 지르코니아 포스트 코어군 모두에서 미세누출을 보였고, 이 중에서 지르코니아 포스트와 열가압형 세라믹 코어군이 좀 더 큰 미세누출에 대한 저항성을 보였으며 화이버 포스트와 콤포짓트 레진 코어군, CAD/CAM 절삭형 지르코니아 포스트 코어군은 유사한 양상을 보였으나, 각 실험군 간에 통계적으로 유의한 차이는 인정되지 않았다. (P>.05)

Micro-CT를 이용한 복합 레진 수복물 미세 누출도의 정량 분석 (Quantitative Micro-CT Evaluation of Microleakage in Composite Resin Restorations)

  • 이상익;현홍근;김영재;김정욱;이상훈;김종철;한세현;장기택
    • 대한소아치과학회지
    • /
    • 제34권2호
    • /
    • pp.222-233
    • /
    • 2007
  • 치과 수복 재료 검사 시 가장 중요하고 기본적인 것은 치아와 수복물 사이의 미세누출에 대한 평가이다. 미세 누출을 평가하는 방법은 여러 가지가 있지만 이들 대부분은 많은 단점들을 가지고 있다. 최근에 개발된 미세 단층촬영법(micro-CT)을 이용하면 시편을 비파괴적으로 처리하여 특정 밀도에 해당하는 부분의 3차원적 영상을 얻을 수 있으므로, 이를 이용하면 정확하고 정량적인 미세누출 평가도 가능할 것이다. 이 연구의 목적은 micro-CT를 사용하여, 레진 수복물의 미세 누출도를 정량적이고 비파괴적으로 측정할 수 있는 새로운 방법을 찾아내고, 이 새로운 방법을 기존의 색소 침투법과 비교해보는 것이다. 이를 위해, 위의 두 가지 방법을 사용하여 두 종류의 상아질 접착 시스템의 미세누출도가 평가되었다. 사람의 건전 소구치 40개를 임의로 20개씩 두 군으로 나누고 다음과 같이 처리하였다. Group 1 : $Adper^{TM}$ Singe Bond 사용 후 제 V급 와동 레진 수복, Gourp 2 : $Adper^{TM}\;Promp^{TM}$ L-pop 사용 후 제 V급 와동 레진 수복 모든 치아의 5급 와동은 $Filtek^{TM}$ Supreme으로 수복하였다. 그 후 각 군 중 10개의 치아는 micro-CT를 사용하여 미세 누출도를 평가하고, 나머지 10개는 기존의 색소 침투법으로 평가하였다. 이 연구의 결과는 다음과 같았다. 1. Micro-CT를 사용한 경우, 1군은 2군보다 통계적으로 유의성 있게 적은 양의 미세 누출을 보였다(p<0.01). 2. 기존의 색소 침투법을 사용한 경우에서 1군은 2군보다 적은 미세누출을 보였으며 이는 통계적으로 유의성이 있었다. (p<0.01). 3. 두 군간의 미세 누출도는 micro-CT를 사용한 방법에서 더 현저한 차이를 보였다. 4. 두 가지 방법 모두에서 법랑질 변연 부분보다 상아질 변연 부분에서 더 많은 미세 누출을 보였다.

  • PDF