• Title/Summary/Keyword: microfluidics

Search Result 166, Processing Time 0.021 seconds

Experimental Study of Dynamic Behavior of a Water Droplet on Diverse Wrinkling Surfaces (마이크로 표면주름 구조에 따른 물방울 동적거동에 관한 실험적 연구)

  • Baek, Dae Hyeon;Zhao, Zhijun;Park, Sang-Hu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.6
    • /
    • pp.577-585
    • /
    • 2015
  • We fabricated multi-scale such as macro-, micro-, and multi-scale wrinkles by using repetitive volume dividing (RVD) method and thermal curing process. Also wrinkle surface was modified with coating of a self-assembled monolayer (SAM). We measured the contact angle of each wrinkled surface, and observed the behavior of droplets on sloping surface. Through experimental study, we found out that the contact angle was much higher in case of multi-scale and SAM coated wrinkles. And micro-scale wrinkle showed a high contact angle comparing with that of macro-scale wrinkle. Dynamic behaviors of a water droplet like sliding velocity on diverse wrinkled surfaces were dependent on their static contact angles. These results showed that hydro-dynamic characteristics were changed depending on the wrinkle structure and the material forming the wrinkle. These dynamic characteristics can be utilized in bio-chip, microfluidics, and many others in order to control easily chemical reactivity.

Development of a Three-Dimensional Barrier Embedded Kenics Micromixer by Means of a Micro-Stereolithography Technology (마이크로 광 조형기술을 이용한 3차원의 배리어가 포함된 케닉스 마이크로 믹서의 개발)

  • Lee In Hwan;Kwon Tai Hun;Cho Dong-Woo;Kim Dong Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.6 s.237
    • /
    • pp.904-912
    • /
    • 2005
  • The flow in a microchannel is usually characterized as a low Reynolds number (Re) so that good mixing is quite difficult to be achieved. In this regard, we developed a novel chaotic micromixer, named Barrier Embedded Kenics Micromixer (BEKM). In the BEKM, the higher level of chaotic mixing can be achieved by combining two general chaotic mixing mechanisms: (i) splitting/reorientation by helical elements inside the microchannel and (ii) stretching/folding via periodically located barriers on the channel wall. The fully three-dimensional geometry of BEKM was realized by a micro-stereolithography technology, in this study, along with a Kenics micromixer and a circular T-pipe. Mixing performances of three micromixers were experimentally characterized in terms of an average mixing color intensity of phenolphthalein. Experimental results show that BEKM has better mixing performance than other two micromixers. Chaotic mixing mechanism, proposed in this study, could be integrated as a mixing component with Micro-Total-Analysis-System, Lab-on-a-chip and so on.

Design and Fabrication of PZT Disc Actuated Micro Pump for Bio-Applications (I): Optimal Design of Ring-shaped Flab Valve Module (바이오용 압전디스크방식 마이크로 펌프 설계 및 제작(I) -링형 플랩밸브 모듈의 최적설계-)

  • Kim, Hyung-Jin;Seo, Young-Ho;Kim, Byeong-Hee
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.3
    • /
    • pp.355-361
    • /
    • 2012
  • Though a micro pump is a crucial element in miniaturized bio-fluidic systems or drug delivery systems, it has some intrinsic disadvantages such as backward flow, pulsation of flow, low repeatability and producibility, and high cost. To overcome these limitation, a PZT disc actuated micro pump including a novel ring-shaped multi-flap check valve is introduced. To enhance the performance of the micro pump, the static behaviour of flap valve module and the micro fluidic behavior of fluids are numerically modelled and analyzed. As results of the numerical analysis, the optimal dimension and configuration of the ring-shaped multi flap valve are $1{\times}0.05$ mm and 2 (inlet side)${\times}1$ (outlet side) type. The obtained maximum flow rates and flow resolution are about 90 ml/min and 30 ${\mu}l$/stroke respectively.

Flow Characteristics in a Microchannel Fabricated on a Silicon Wafer (실리콘 웨이퍼 상에 제작된 미소 유로에서의 유동특성)

  • Kim, Hyeong-U;Won, Chan-Sik;Jeong, Si-Yeong;Heo, Nam-Geon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1844-1852
    • /
    • 2001
  • Recent developments in microfluidic devices based on microelectromechanical systems (MEMS) technique find many practical applications, which include electronic chip cooling devices, power MEMS devices, micro sensors, and bio-medical devices among others. For the design of such micro devices, flows characteristics inside a microchannel have to be clarified which exhibit somewhat different characteristics compared to conventional flows in a macrochannel. In the present study microchannels of various hydraulic diameters are fabricated on a silicon wafer to study the pressure drop characteristics. The effect of abrupt contraction and expansion is also studied. It is found from the results that the friction factor in a straight microchannel is about 15% higher than that in a conventional macrochannel, and the loss coefficients in abrupt expansion and contraction are about 10% higher than that obtained through conventional flow analysis.

Measurement of cell aggregation characteristics by analysis of laser-backscattering in a microfluidic rheometry

  • Shin, Se-Hyun;Hou, J.X.;Suh, Jang-Soo
    • Korea-Australia Rheology Journal
    • /
    • v.19 no.2
    • /
    • pp.61-66
    • /
    • 2007
  • The aggregation characteristics of red blood cells (RBCs) are known as important factors in the microvascular flow system, and increased RBC aggregation has been observed in various pathological diseases, such as thrombosis and myocardial infarction. This paper describes a simple microfluidic device for measuring the RBC aggregation by integrating a microfluidic slit rheometry and laser-backscattering technique. While a decreasing-pressure mechanism was applied to the microfluidic rheometry, a syllectogram (the light intensity versus time) showed an initial increase and a peak caused by the high shear stress-induced disaggregation, immediately followed by a decrease in the light intensity due to RBC aggregation. The critical shear stress (CST) corresponding to the peak intensity was examined as a new index of the RBC aggregation characteristics. The CST of RBCs increased with increasing aggregation-dominating protein (fibrinogen) in the blood plasma. The essential feature of this design was the combination of the rheometric-optic characterization of RBC aggregation with a microfluidic chip, which may potentially allow cell aggregation measurements to be easily carried out in a clinical setting.

Fabrication of Ceramic-based Passive Mixers for Microfluidic Application by Thick Film Lithography (후막리소그라피를 이용한 세라믹기반의 미세유체소자용 수동형 혼합기의 제조)

  • Choi, Jae-Kyung;Yoon, Young-Joon;Lim, Jong-Woo;Kim, Hyo-Tae;Koo, Eun-Hae;Choi, Youn-Suk;Lee, Jong-Heun;Kim, Jong-Hee
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.11
    • /
    • pp.739-743
    • /
    • 2008
  • Microfluidic device can be applied in a wide range of chemical and biological technology. In this paper, ceramic-based T-type passive mixers for microfluidic applications were fabricated by LTCC process combined with thick film photolithography. The base ceramic material in thick film was amorphous cordierite $((Mg,Ca)_2Al_4Si_5O_{18})$ and photoimageable polymers were added to give a photosensitivity. Two types of passive mixer, which showed the channel width of 1.0 mm and $200{\mu}m$, respectively, were designed considering mixing efficiency in the channel and their microfluidic properties were discussed in detail.

Development of Engine Piston Ring Surface for Friction Reduction using Micro Abrasive Air Jet (Micro-AAJ를 이용한 엔진 피스톤 링의 마찰 저감 표면 개발)

  • Choi, Soochang;Ro, Seung-Kook;Lee, Hyun-Hwa;Park, Jong-Kweon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.5
    • /
    • pp.389-394
    • /
    • 2014
  • In this paper, we report a new manufacturing method for friction reduction using micro-AAJ (abrasive air-jet) machining. AAJ machining employs compressed air to accelerate a jet of high-speed particles to mechanically machine features, including micro-channels and micro-holes, into glass, metal, or polymer substrates for use in microfluidics, MEMS (micro electromechanical systems). And we introduce the micro-AAJ machining system, which consists of a micro-AAJ nozzle and a five-axis positioning system. Various micro-AAJ nozzles can be used, depending on the required surface structure, and three-dimensional machining is possible. We machined samples under six different conditions and describe machining results obtained while using it. We also measured the coefficient of friction of micro-textured surfaces. We report the coefficient of friction of micro-textured surfaces patterned using micro-AAJ machining for engine piston ring.

Valve actuation effects on discrete monopropellant slug delivery in a micro-scale fuel injection system

  • McDevitt, M. Ryan;Hitt, Darren L.
    • Advances in aircraft and spacecraft science
    • /
    • v.1 no.4
    • /
    • pp.409-425
    • /
    • 2014
  • Converging flows of a gas and a liquid at a microchannel cross junction, under proper conditions, can result in the formation of periodic, dispersed microslugs. This microslug formation phenomenon has been proposed as the basis for a fuel injection system in a novel, 'discrete' monopropellant microthruster designed for use in next-generation miniaturized satellites. Previous experimental studies demonstrated the ability to generate fuel slugs with characteristics commensurate with the intended application during steady-state operation. In this work, numerical and experimental techniques are used to study the effect of valve actuation on slug characteristics, and the results are used to compare with equivalent steady-state slugs. Computational simulations of a valve with a 1 ms valve-actuation cycle show that as the ratio of the response time of the valve to the fully open time is increased, transient effects can increase slug length by up to 17%. The simulations also demonstrate that the effect of the valve is largely independent of surface tension coefficient, which is the thermophysical parameter most responsible for slug formation characteristics. Flow visualization experiments performed using a miniature valve with a 20 ms response time showed less than a 1% change in the length of slugs formed during the actuation cycle. The results of this study indicate that impulse bit and thrust calculations can discount transient effects for slower valves, but as valve technology improves transient effects may become more significant.

Microchannels for the Flow Control of Two Fluids with Different Volumes (부피가 다른 두 유체의 효과적인 유동제어를 위한 미세채널)

  • La, Moon-Woo;Ho, Jae-Yun;Kim, Dong-Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.1
    • /
    • pp.89-95
    • /
    • 2012
  • In this paper, microchannels for the flow control of two fluids with different volumes have been designed, fabricated, and verified. The dimensions of the inlets were determined based on the Stokes equation in order to realize that the flow of the two fluids meet at the same time, and to maintain a certain configuration when the flows passed through each inlet channel. The designed microchannels were confirmed using computational fluid dynamics simulation for the incompressible, Newtonian, and transient flows. In addition, a microfluidic system containing the designed microchannels was fabricated by soft lithography, and the pressure-driven flows of the two fluids were characterized by microfluidic experiments.

Mixing Efficiency Evaluation in Y-channel Micromixer Using LIF Confocal Microscope (LIF 공초점 현미경을 이용한 Y-채널 마이크로믹서의 혼합 효율 평가)

  • Kim, Kyoung-Mok;Shin, Yong-Su;Ahn, Yoo-Min;Lee, Do-Hyung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.2 s.257
    • /
    • pp.159-166
    • /
    • 2007
  • Mixing between two or more reagents is one of important processes in biochemical microfluidics. In efficient micromixer design, it is essential to analyze flow pattern and evaluate mixing efficiency with good precision. In this work, mixing efficiency for Y-channel micromixer is measured by fluorescence intensity using LIF(Laser Induced Fluorescence) Confocal Microscope. The Y-channel micromixers are fabricated with polydimethylsiloxane(PDMS) and those are bonded to glass plate through Plasma bonding. Nile Blue A is injected into the micromixer as a fluorescence dye for measuring of fluorescence intensity by He/Ne laser. For visualization of the flow pattern, dynamic image capturing is carried out using CAM scope. For the comparison with computer simulation, modified SIMPLE algorithm for incompressible flow equation is solved for the same geometry as in the experiment. Throughout the experiments and computer simulation, accurate mixing efficiency evaluation process for a PDMS Y-channel micromixer is established.