• Title/Summary/Keyword: microelectrode

Search Result 141, Processing Time 0.022 seconds

Rapid Detection of Salmonella enteritidis in Pork Samples with Impedimetric Biosensor: Effect of Electrode Spacing on Sensitivity

  • Kim, Gi-Young;Moon, Ji-Hea;Hahm, Bung-Kwon;Morgan, Mark;Bhunia, Arun;Om, Ae-Son
    • Food Science and Biotechnology
    • /
    • v.18 no.1
    • /
    • pp.89-94
    • /
    • 2009
  • Frequent outbreaks of foodborne illness have been increasing the awareness of food safety. Conventional methods for pathogen detection and identification are labor-intensive and take days to complete. Some immunological, rapid assays are developed, but these assays still require prolonged enrichment steps. Recently developed biosensors have shown potential for the rapid detection of foodborne pathogens. In this study, an impedimetric biosensor was developed for rapid detection of Salmonella entritidis in food sample. To develop the biosensor, an interdigitated microelectrode (IME) was fabricated by using a semiconductor fabrication process. Anti-Salmonella antibodies were immobilized based on neutravidin-biotin binding on the surface of the IME to form an active sensing layer. To evaluate the effect of electrode gap on sensitivity of the sensor, 3 types of sensors with different electrode gap sizes (2, 5, and $10{\mu}m$) were fabricated and tested. The impedimetric biosensor could detect $10^3\;CFU/mL$ of Salmonella in pork meat extract with an incubation time of 5 min. This method may provide a simple, rapid, and sensitive method to detect foodborne pathogens.

Electrochemical Reduction of Thionyl Chloride : Catalytic Effects of Metalomacrocyclic Compounds (SOCl$_2$의 전기화학적 환원 : 금속-거대고리 화합물의 촉매효과)

  • Woo-Seong Kim;Yong-Kook Choi;Chjo Ki-Hyung
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.8
    • /
    • pp.744-752
    • /
    • 1993
  • Electrochemical reduction of thionyl chloride has been carried out at glassy carbon and microelectrode that modified by macrocyclic compounds. The catalyst molecules of macrocyclic compounds were adsorbed on the electrode surface and reduced thionyl chloride resulting in a generation of oxidized catalyst molecules. The concentration of catalysts and electrode immersion time were found to affect the catalyst performance strongly. Significant improvements in cell performance have been noted in terms of both exchange rate constants of up to 10 times and power densities of up to 220% at glassy carbon electrode. The diffusion coefficients obtained at carbon microelectrode were slightly different from that determined at glassy carbon electrode.

  • PDF

Electrochemical Behavior of a Nickel Hydroxide Particle for Ni-MH Battery by Microelectrode (마이크로전극에 의한 니켈수소전지용 수산화니켈 입자의 전기화학적 거동)

  • Kim, Ho-Sung;Oh, Ik-Hyun;Lee, Jong-Ho
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.2
    • /
    • pp.145-149
    • /
    • 2007
  • Electrochemical studies were performed for a single particle of nickel hydroxide for the cathode of Ni-MH batteries. A carbon fiber microelectrode was manipulated to make electrical contact with an alloy particle, and electrochemical experiments were performed. As a result of cyclic voltammetry, the oxidation/reduction and oxygen evolution reaction (OER) are clearly separated for a single particle. The total cathodic charge (Qred) is practically constant for the scan rate investigated, indicating that the whole particle has reacted. The total anodic charge(Qox) was larger than that of reduction reaction, and the magnitude of oxygen evolution taking place as a side reaction was enhanced at lower scan rates. As a result of galvanostatic charge and discharge measurement, the discharge capacity of single particle was found to be 250 mAh/g, value being very close to the theoretical capacity (289 mAh/g). The apparent proton diffusion coefficient(Dapp) using potential step method inside the nickel hydroxide was found to range within $3{\sim}4{\times}10^{-9}\;cm^2/s$.

Continuous Measurement of Ammonium-nitrogen and Nitrate-nitrogen using a Ion-Selective Microelectrode (이온선택성 미소전극을 이용한 암모니아성 질소 및 질산성 질소의 연속 농도 측정)

  • Lim, Mi-Ji;Seon, Ji-Yun;Park, Jeung-Jin;Byun, Im-Gyu;Park, Tae-Joo;Lee, Tae-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.718-724
    • /
    • 2008
  • The ion selective microelectrode (ISME) has been used for measuring the ion profile of DO, $NH_4{^+}-N$, $NO_2{^-}-N$ and $NO_3{^-}-N$ in biofilm. In this study we evaluated the detection limit and validity of ISME and applied ISME for the continuous measurement of $NH_4{^+}-N$ and $NO_3{^-}-N$ concentration in the modified Ludzack-Ettinger (MLE) process. Average detection limits of $NH_4{^+}-N$ and $NO_3{^-}-N$ ISME were $10^{-4.44}M$ and $10^{-4.62}M$, respectively. Since the ISME with $5{\sim}10{\mu}m$ of tip diameter showed a faster response time than that of $1{\sim}5{\mu}m$, the ISME with a tip diameter of $5{\sim}10{\mu}m$ was fabricated and used to make real-time ion detections. Direct monitoring of $NH_4{^+}-N$ and $NO_3{^-}-N$ concentrations in the aerobic (2) tank causes the instability of the electromotive force (EMF) for the initial 5~8 hours and also causes remarkable error values of $NH_4{^+}-N$ and $NO_3{^-}-N$ concentration. This phenomenon is caused by aeration and mixing in the reactor. Thus, the measuring chamber was newly designed for the aerobic (2) tank and then the EMF of the ISME were stabilized in less than 1 hour. Errors of $NH_4{^+}-N$ and $NO_3{^-}-N$ concentration were decreased after stabilization of the EMF. The ISME analysis were well corresponded to the results of auto analyzer and ion chromatography. Consequently, the concentration of $NH_4{^+}-N$ and $NO_3{^-}-N$ could be continuously measured for 178 hours by the ISME.

Analysis and Usefulness of Microelectrode Recording during Deep Brain Stimulation Surgery in Movement Disorders (이상운동질환에 대한 뇌심부자극 수술 중에 미세전극 기록의 분석과 유용성)

  • Baek, Jae-Seung;Park, Sang-Ku;Kim, Dong-Jun;Park, Chan-Woo;Lim, Sung-Hyuk;Hyun, Soon-Chul
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.4
    • /
    • pp.468-474
    • /
    • 2019
  • Deep brain stimulation (DBS) is an effective surgical procedure for treating drug refractory movement disorders, and DBS involves delivering high frequency electrical stimulation to deep brain nuclei. Microelectrode recording (MER) is a complementary test that can precisely identify the location of deep brain nuclei, along with MRI correlation, during DBS surgery to improve the surgical outcome and minimize side effects. The purpose of this paper is to analyze the neuro-physiological waveforms and identify the usefulness of MER by analyzing the MER performed during DBS surgery for treating movement disorders. We retrospectively reviewed 28 patients who underwent MER during DBS surgery for movement disorders from January to December 2018. Of the 28 patients, 38 MERs for the subthalamic nucleus (STN), 10 MERs for the globuspallidusinternus (Gpi), and 4 MERs for the ventral intermediate thalamic nucleus (VIM) were performed. In all the cases, the target sites were found and micro-stimulations were used to check for side effects and to readjust the target sites. The clinical symptoms of all 28 patients improved after surgery. In conclusion, MER is a useful test that employs neuro-physiological waveforms to accurately identify the deep brain nuclei, along with MRI correlation, to improve the DBS surgical outcomes for movement disorders and to minimize side effects.

Indicator-free DNA Chip Array Using an Electrochemical System

  • Park, Yong-Sung;Kwon, Young-Soo;Park, Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.4
    • /
    • pp.133-136
    • /
    • 2004
  • This research aims to develop a DNA chip array without an indicator. We fabricated a microelectrode array through photolithography technology. Several DNA probes were immobilized on an electrode. Then, target DNA was hybridized and measured electrochemically. Cyclic-voltammograms (CVs) showed a difference between the DNA probe and mismatched DNA in an anodic peak. This indicator-free DNA chip resulted in a sequence-specific detection of the target DNA.

Electrochemical Behaviors of the Surface-Treated Nickel Hydroxide Powder and Electrolyte Additive LiGH for Ni-MH Batteries (니켈수소전지용 수산화니켈 입자의 표면처리와 전해액 첨가제 LiOH의 전기화학적 거동)

  • Kim, Ho-Sung;Oh, Ik-Hyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.11 no.2
    • /
    • pp.115-119
    • /
    • 2008
  • Single particle of nickel hydroxide and the surface-treated one with cobalt element were performed to review the effect of LiOH additive in alkaline electrolyte for Ni-MH batteries using microelectrode test system. As a result of cyclic voltammetry, the electrochemical behaviors such as the oxidation/reduction and oxygen evolution reaction are clearly observed for a single particle of nickel hydroxide, respectively. Furthermore, the reduction current peak of nickel hydroxide added with LiOH in electrolyte was very low and broad compared with the normal nickel hydroxide without an additive LiOH, which had a bad effect to the crystallization structure of nickel hydroxide. However, it was found that capacity and cycle properties of the nickel hydroxide treated with cobalt greatly increased by the addition of LiOH.

Kinetic Parameter Analysis of Hydrogen Diffusion Reaction for Hydrogen Storage Alloy of Fuel Cell System (연료전지의 수소저장용 합금에 대한 수소확산반응의 속도론적 해석)

  • Kim, Ho-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.45-49
    • /
    • 2006
  • Electrochemical hydrogenation/dehydrogenation properties were studied for a single particle of a Mm-based(Mm : minh metal) hydrogen storage alloy($MmNi_{3.55}Co_{0.75}Mn_{0.4}Al_{0.3}$) for fuel cell and Ni-MH batteries. A carbon fiber microelectrode was manipulated to make electrical contact with an alloy particle, and the potential-step experiment was carried out to determine the apparent chemical diffusion coefficient of hydrogen atom($D_{app}$) in the alloy. Since the alloy particle we used here was a dense, conductive sphere, the spherical diffusion model was employed for data analysis. $D_{app}$ was found to vary the order between $10^{-9}\;and\;10^{-10}[cm^2/s]$ over the course of hydrogenation and dehydrogenation process. Compared with the conventional composite film electrodes, the single particle measurements using the microelectrode gave more detailed, true information about the hydrogen storage alloy.

The Effects of 1, 4-Dihydropyridine Calcium Antagonists on the Normal and Ca-dependent, Slow Channel Mediated Action Potentials in the Guinea Pig's Papillary Muscle (1, 4-Dihydropyridine 칼슘길항제가 유두근의 정상활동전압 및 Ca-dependent, Slow Channel Mediated Action Potential에 미치는 영향)

  • Kim, Min-Hyung;Chang, Seok-Jong
    • The Korean Journal of Physiology
    • /
    • v.22 no.2
    • /
    • pp.207-218
    • /
    • 1988
  • Effects of 1, 4-dihydropyridine compounds, such as nifedipine, nisoldipine, nitrendipine, and nimodipine which were calcium antagonists on the normal and Ca-dependent, slow channel mediated action potentials in the guinea pig's papillary muscle were investigated. The glass microelectrode was impaled into a papillary muscle cell for measurements of potential changes with the simultaneous tracing of isometric contraction. The concentration of Ca antagonists were 1 mg/l (nifedipine and nisoldipine), 2 mg/l (nitrendipine and nimodipine), which showed the maximal inhibition of isometric contraction (above 90%) and simultaneous effects on the normal action potentials and only the halves of those concentrations were sufficient to observe the effects on the calcium action potentials. The data for analysis were only chosen when the microelectrode was maintained in a cell throughout the experiments. 1, 4-Dihydropyridine compounds decreased the action potential duration but did not affect the resting membrane potential, overshoot, and upstroke velocity of the normal action potentials with the decrease in the isometric contraction. And with the decrease in the area and amplitude of isometric contraction, the area, amplitude, upstroke velocity and duration of Ca action potential was decreased. But the differences in the effects of the Ca antagonists were not observed. Therefore it is inferred that the changes in normal and Ca action potential induced by the 1, 4-dihydropyridine compounds with a common chemical structure would be caused by the slow inward Ca-current, not by a fast Na-current.

  • PDF