• Title/Summary/Keyword: microbalance

Search Result 186, Processing Time 0.03 seconds

Novel Detection Technology for Glycated Hemoglobin using Gold Nanoparticles (금 나노입자를 이용한 새로운 당화혈색소의 검출 기술)

  • Lee, Soo Suk
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.435-439
    • /
    • 2016
  • We report a novel detection technology for glycated hemoglobin (HbA1c) that is measured primarily to identify the three-month average plasma glucose concentration. In enzymatic measuring of glycated hemoglobin, the generated hydrogen peroxide was then used as a reducing agent of gold (III) for the synthesis of gold (0). Gold nanoparticles obtained from this novel approach were measured by optical and piezoelectric methods. In optical method, we have developed polymer based film-type sensor cartridge filled with all the reagents for glycated hemoglobin analysis and the cartridge worked very well having the detection limit of 0.53% of glycated hemoglobin. On the other hand, quartz crystal microbalance (QCM) sensors also have been developed to determine the abilities of surface modified QCM sensors at various levels of the concentration of glycated hemoglobin to bind gold nanoparticles and limit of detection was 0.90%. Finally, despite of relatively lower sensitivities of QCM sensor and film-type optical sensor than well-plate based optical detection, these two sensors were available to measure the glycated hemoglobin level for diabetes patients and normal person.

Study on the velocity of gadolinium atomic vapor produced by electron beam heating (전자빔 가열로 발생시킨 Gd 원자증기의 속도에 관한 연구)

  • 정의창;권덕희;고광훈;김택수
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.4
    • /
    • pp.228-234
    • /
    • 2003
  • The velocity of gadolinium(Gd) atomic vapor vaporized by an electron beam was measured by a microbalance. The velocity of about 900 ㎧ was obtained at an evaporation surface temperature of 2400-2500 K. The measured value was approximately 100 ㎧ faster than the maximum velocity of an ideal monatomic gas in an adiabatic expansion. This phenomenon can be explained that the internal energy of Gd atoms populated in higher excited levels at the high temperature should be convened to kinetic energy during adiabatic expansion. The calculated velocity agrees with the measured one when 100 excited energy levels are included in an enthalpy term for the velocity calculation. The characteristics of vapor flow as a function of heated surface temperature are also reported.

Formation of Indium Bumps on Micro-pillar Structures through BCB Planarization (BCB 평탄화를 활용한 마이크로 기둥 구조물 위의 인듐 범프 형성 공정)

  • Park, Min-Su
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.4
    • /
    • pp.57-61
    • /
    • 2021
  • A formation process of indium bump arrays on micro-pillar structures is proposed. The space to form indium bump on the narrow structures can be secured applying the benzocyclobutene (BCB) planarization and its etch-back process. We exhibit a detailed overview of the process steps involved in the fabrication of 320×256 hybrid camera sensor for short-wavelength infrared (SWIR) detection. The shear strength of the BCB, which has undergone the different processes, is extracted by quartz crystal microbalance measurement. The shear strength of the BCB is three orders of magnitude higher than that of the indium bump itself. The measured dark current distribution of the fabricated SWIR camera sensor indicates the suggested process of indium bumps can be useful for embodying highly sensitive infared camera sensors.

Measurement of I-TEDA Removal Rate Using QCM in Supercritical Carbon Dioxide (초임계이산화탄소 하에서 QCM을 이8한 I-TEDA의 제거특성 측정)

  • Yoo, Jae-Ryong;Koh, Moon-Sung;Sung, Jin-Hyun;Lee, Jeong-Ken;Park, Kwang-Heon
    • Clean Technology
    • /
    • v.14 no.2
    • /
    • pp.110-116
    • /
    • 2008
  • The radioactive wastes generated from the nuclear industry can be divided into the forms of solid, liquid, or gas. Radioactive methyl iodide, a gaseous radioactive waste, is absorbed by activated carbon with 5 wt% of Trietylenediamine (1,4-diazania-bicycle[2.2.2]octane, TEDA) impregnated on the surface. Methyl Iodide ($CH_3I$) is combined chemically with TEDA (the final product : I-TEDA). To recycle radioactive activated carbon, removal of I-TEDA from activated carbon is needed. A wet method for recycling impregnated active carbon was developed to remove radioactive I-TEDA using an acetonitrile solution, which produces lots of secondary wastes. We suggest the removal of I-TEDA by supercritical carbon dioxide with co-solvents. In this experiment, we used a quartz crystal microbalance (QCM) for measuring the removal rate of the I-TEDA. From the experimental results, methanol was found to be the optimum co-solvent, and the optimum conditions such as temperature, pressure, and co-solvent flow rate were obtained. Possibility of using supercritical fluid in the removal of I-TEDA from radioactive activated carbon was also discussed.

  • PDF

Measurement of an Isoelectric Point and Softness of a EO-PO Adducted Zwitterionic Surfactant (EO-PO가 부가된 양쪽성 계면활성제의 등전점 및 유연력 측정에 관한 연구)

  • Lim, JongChoo;Mo, DaHee;Lee, JinSun;Park, JunSeok;Han, DongSung
    • Korean Chemical Engineering Research
    • /
    • v.50 no.3
    • /
    • pp.455-463
    • /
    • 2012
  • In this study, the measurement of physical properties of ethylene oxide-propylene oxide adducted zwitterionic surfactants were measured such as critical micelle concentration, surface tension, interfacial tension, contact angle, viscosity and foam stability. Also, the dual function characteristics of a zwitterionic surfactant were investigated by determining an isoelectric point, which were obtained using zeta potential measurement and QCM (quartz crystal microbalance) experiments. The isoelectric point of DEP-OSA82-AO zwitterionic surfactant determined by zeta potential measurement was close to that obtained by QCM experiment and both results have shown almost the same trend as that determined by the frictional property measured using an automated mildness tester. In particular, it has been observed that DEP32-OSA82-AO and DEP34-OSA82-AO surfactants provide better softening effect at a pH of acidic or neutral condition than at an alkaline condition. This result indicates that both surfactants act as a cationic surfactant at a pH of acidic or neutral condition and thus provide good softening effect during a rinsing cycle in the detergency process.

Introduction to Electrochemical Quartz Crystal Microbalance Technique for Leaching Study of Metals (금속 침출연구를 위한 전기화학적 미소수정진동자저울 기술 소개)

  • Kim, Min-seuk;Chung, Kyeong Woo;Lee, Jae-chun
    • Resources Recycling
    • /
    • v.29 no.1
    • /
    • pp.25-34
    • /
    • 2020
  • Electrochemical Quartz Crystal microbalance is a tool that is capable of measuring nanogram-scale mass change on electrode surface. When applying alternating voltage to the quartz crystal with metal electrode formed on both sides, a resonant frequency by inverse piezoelectric effect depends on its thickness. The resonant frequency changes sensitively by mass change on its electrode surface; frequency increase with metal dissolution and decrease with metal deposition on the electrode surface. The relationship between resonant frequency and mass change is shown by Sauerbrey equation so that the mass change during metal dissolution can be measured in real time. Especially, it is effective in the case of reaction mechanism and rate studies accompanied by precipitation, volatilization, compound formation, etc. resulting in difficulties on ex-situ AA or ICP analysis. However, it should be carefully considered during EQCM experiments that temperature, viscosity, and hydraulic pressure of solution, and stress and surface roughness can affect on the resonant frequency. Application of EQCM was shown as a case study on leaching of platinum using aqueous chlorine for obtaining activation energy. A platinum electrode of quartz crystal oscillator with 1000 Å thickness exposed to solution was used as leaching sample. Electrogenerated chlorine as oxidant was purged and its concentration was controlled in hydrochloric acid solution. From the experimental results, platinum dissolution by chlorine is chemical reaction control with activation energy of 83.5 kJ/mol.

The electrochemical desorption of an eicosanethiol monolayer by electrochemical quartz crystal microbalance (EQCM을 이용한 아이코산티올 단분자막의 전기화학적 탈착)

  • Chung, Chinkap
    • Analytical Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.383-389
    • /
    • 1995
  • A new approach for the measurement of the surface coverages of monomolecular films fabricated by spontaneous adsorption of thiol compounds on gold is described. It is based on the mass change measurement with EQCM for the reductive electrochemical desorption of thiol in aqueous KOH solution. The results were compared with that of charge calculation during electrochemical desorption. The surface coverage value for eicosanethiol agrees with that obtained by charge calculation of electrochemical reduction as well as that expected from a geometrical model of the compact monolayer.

  • PDF

Evaluation of an electrical impactor with porous metal substrate (다공성 금속판을 이용한 전기적 임팩터의 평가)

  • Jeong Jeong-Seon;Gwon Sun-Park;Lee Gyu-Won
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.276-277
    • /
    • 2002
  • One of drawbacks of the inertial impactor measurement is the required long sampling time (Keskinen et al., 1992). In a gravimetric method, an impaction substrate must be weighed and placed on the corresponding collection plate before being assembled. After sampling, the inertial impactor is disassembled and the collection plate is weighted again. The sampling time depends on the sampled particle mass because the collected particle mass must be sufficiently high to be measured by a sensitive microbalance. (omitted)

  • PDF

Resistance and Frequency Properties Analysis of QCM Coated with LB Films (LB막이 누적된 QCM의 저항 및 주파수 특성해석)

  • 강현욱;진철남;김정명;권명수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.465-467
    • /
    • 1997
  • The oscillating properties of quartz Crystal Microbalance(QCM) were analyzed by electrical measurement. We tried to analyze the properties of quartz crystal coated with Langmuir-Bladgett(LB) films using the frequency and resistance at resonance in the electrical equivalent circuit. The resonant frequency was decreased linearly as to layers of LB films, however, there are some gap between theoretical values, Sauerbrey's equation and experimental values. The resistance was increase nonlinearly as to layers.

  • PDF