• Title/Summary/Keyword: micro-stress

Search Result 856, Processing Time 0.031 seconds

The relation between shape and interfacial stress of dental implants (치과용 임플란트의 형상과 계면 응력의 상관관계)

  • Kim, H. S.;Lee, S. U.;Cho, N. H.;Ko, J. Y.;Park, S. S.;lee, H.;Ahn, S.;Shim, J. S.;Lee, C. Y.;Moon, H. S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.128-131
    • /
    • 2002
  • Several FE models were developed based on micro-CT images of a mandibular specimen. A new dental implant model was suggested from parameter study for the relation between shape and interfacial stress of dental implants. It is found that the proposed model is highly beneficial.

  • PDF

Analysis of 3D Geometry and Compressive Behavior of Aluminum Open Cell Foam Using X-ray Micro CT (마이크로 X-ray CT를 활용한 알루미늄 개방형 폼의 형상 및 압축 거동 분석)

  • Kim, Y.I.;Kim, J.H.;Lee, J.K.;Kim, D.
    • Transactions of Materials Processing
    • /
    • v.20 no.7
    • /
    • pp.518-523
    • /
    • 2011
  • The three dimensional geometries of an aluminum open cell foam before and after uniaxial compressive loading were investigated using the X-ray micro CT(computed tomography). Aluminum 6101-T6 open cell foams of 10, 20, 40 ppi (pore per inch) were considered in this work. After the serial sectioning CT images of aluminum foams were obtained from non-destructive X-ray images, the exact 3D structure were reproduced and visualized with commercial image processing program. The relative density ratio was around the 7.0 to 9.0 range, the unit cells showed anisotropic shapes having the different dimensional ratios of 1.1 to 1.3 between the rise and the transverse directions. The yield stress increased with the relative density ratio and the volumetric strain increased proportionally with compressive strain. The plateau stress in the compressive stress-strain curve was caused by the buckling of ligaments.

Micro-pinholes in Composite Cobalt Nickel Silicides (코발트 니켈 합금 구조에서 생성된 실리사이드의 마이크로 핀홀의 발생)

  • Song, Oh-Sung;Kim, Sang-Yeob;Jeon, Jang-Bae;Kim, M.J.
    • Korean Journal of Materials Research
    • /
    • v.16 no.10
    • /
    • pp.656-662
    • /
    • 2006
  • We fabricated thermal evaporated 10 nm-$Ni_xCo_{1-x}$ (x=0.2, 0.5 and 0.8) /(poly)Si films to form nanothick cobalt nickel composite silicides by a rapid thermal annealing at $700{\sim}1100^{\circ}C$ for 40 seconds. A field emission scanning electron microscope and a micro-Raman spectrometer were employed for microstructure and silicon residual stress characterization, respectively. We observed self-aligned micro-pinholes on single crystal silicon substrates silicidized at $1100^{\circ}C$. Raman silicon peak shift indicates that the residual tensile strain of $10^{-3}$ in single crystal silicon substrates existed after the silicide process. We propose thermal stress from silicide exothermic reaction and high temperature silicidation annealing may cause the pinholes. Those pinholes are expected to be avoided by lowering the silicidation temperature. Our results imply that we may use our newly proposed composite silicides to induce the appropriate strained layer in silicion substrates.

Manufacturing and Tests of Cryostat for SMES (I) (SMES용 Cryostat 시제작 및 평가 (I))

  • 조전욱;심기덕;하홍수;김해종;김봉태;성기철;권영길;류강식;고득용
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.117-120
    • /
    • 2001
  • In this paper we present the results of manufacturing and tests of prototype cryostat for micro-SMES. The prototype cryostat with HTS current leads and refrigerator had been designed and manufactured for micro-SMES. The cryostat had been tested the helium boil-off and mechanical stress during transfer and vibration test. These results will be applied to micro-SMES cryostat.

  • PDF

Fabrication of Nano-Size Specimens for Tensile Test Employing Nano-Indentation Device (나노 인장시험을 위한 압축 시험기용 인장시편 제작에 관한 연구)

  • Lim, Tae Woo;Yang, Dong-Yol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.10
    • /
    • pp.911-916
    • /
    • 2015
  • In the nano/micro scale, material properties are dependent on the size-scale of a structure. However, conventional micro-scale tensile tests have limitations to obtain reliable values of nano-scale material properties owing to residual stress and elastic slippage in the gripping/aligning process. The indenter-driven nano-scale tensile test provides prominent advantages simple testing device, high-quality nano-scale metallic specimen with negligible residual stress. In this paper, two-types of specimens (a specimen with multi-testing parts and a specimen with a single-testing part) are discussed. Focused ion beam (FIB) is employed to fabricate a nano-scale specimen from a thin nickel film. Using the specimen with a single-testing part, we obtained a nano-scale stress-strain curve of electroplated nickel film.

Al-7020의 Pulse-GMA용접에 관한 연구 2

  • 김재웅;허장욱;나석주;백운형
    • Journal of Welding and Joining
    • /
    • v.6 no.4
    • /
    • pp.54-62
    • /
    • 1988
  • Major problems in welding Al-7020 include shrinkage, rpopositgy in welds and loss of strength in the heat affected zone. Thus it is important to examine the mechanical properties and reliability of welds. In this study, a series of experiments was carried out to determine the mechanical properties such as micro-hardness distribution, tensile strength, porosity and residual stress distribution of the Al-7020 weldment made by pulse-GMA welding. The resuts of the experiemnts are as folows. 1) The micro-hardness of weld metal and heat affected zone was lower than that of the base metal. 2) The tensile strength of the deposited metal was much lower than that of the base metal. 3) The porrosity in weld metal zone was negligible under the adopted conditsion of experiemnts. 4) The residual stress in the weld metal was lower than that of the heat affected zone, because the weld metal was softened. And the mciro-hardness distribution, the tensile strength and the residual stess distribution of the weldment in the as-welded condition were compared with those of the weldment after heat treatment.

  • PDF

Diamond-Like Carbon Films Prepared by Magnetized Inductively Coupled Plasma (자화된 유도 결합형 플라즈마를 이용한 다이아몬드성 탄소박막 증착)

  • Kim, Joong-Kyun;Lee, Ho-Jun;Whang, Ki-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.323-325
    • /
    • 1995
  • An Inductively Coupled Plasma(ICP) was employed to prepare the Diamond-Like Carbon film with $CH_4$ gas. We observed the changes of mechanical, optical properties and internal stress of the films according to the variation of discharge power and negative-self bias. When weak magnetic field is applied, the properties of film are observed to change drastically. In magnetized case, the micro-hardness and the internal stress increase up to critical point and droped down in marked contrast to unmagnetized case. It suggests that large amount of ion flux exists due to high dissociation rate of the reactive radicals in plasma with magnetic field as reported elsewhere. As a result of FT-IR absorption measurement it could be confirmed that the $CH_x$ bonding and the micro-hardness and the internal stress decreased with the increase of negative-self bias.

  • PDF

Analysis of Resonance Based Micromechanical Bio-Chemical Sensing Structures (공진 기반 마이크로기계 생화학 센싱 구조물의 해석)

  • Yeo, Min-Ku;Shin, Yoon-Hyuck;Yim, Hong-Jae;Lim, Si-Hyung
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1767-1772
    • /
    • 2008
  • A microcantilever is a well-known MEMS structure for sensing bio-chemical molecules. When bio-chemical molecules are adsorbed on the microcantilever's surface, resonance frequency shift is generated. There are two issues in this phenomena. The first one is which one between mass change and surface stress change effects is more dominant on the resonance frequency shift. The second one is what will be the performance change when the boundary condition is changed from cantilevers to double clamped beams. We have studied the effect of surface stress change and compared it with that of mass change by using FEM analysis. Furthermore, for microstructures having different boundary conditions, we have studied Q-factor, which determines the detection limit of micro/nano mechanical sensors.

  • PDF