• Title/Summary/Keyword: micro-projection

Search Result 64, Processing Time 0.027 seconds

Development of High Resolution Micro-CT System for In Vivo Small Animal Imaging (소형 동물의 생체 촬영을 위한 고해상도 Micro-CT 시스템의 개발)

  • Park, Jeong-Jin;Lee, Soo-Yeol;Cho, Min-Hyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.95-101
    • /
    • 2007
  • Recently, small-animal imaging technology has been rapidly developed for longitudinal screening of laboratory animals such as mice and rats. One of newly developed imaging modalities for small animals is an x-ray micro-CT (computed tomography). We have developed two types of x-ray micro-CT systems for small animal imaging. Both systems use flat-panel x-ray detectors and micro-focus x-ray sources to obtain high spatial resolution of $10{\mu}m$. In spite of the relatively large field-of-view (FOV) of flat-panel detectors, the spatial resolution in the whole-body imaging of rats should be sacrificed down to the order of $100{\mu}m$ due to the limited number of x-ray detector pixels. Though the spatial resolution of cone-beam CTs can be improved by moving an object toward an x-ray source, the FOV should be reduced and the object size is also limited. To overcome the limitation of the object size and resolution, we introduce zoom-in micro-tomography for high-resolution imaging of a local region-of-interest (ROI) inside a large object. For zoom-in imaging, we use two kinds of projection data in combination, one from a full FOV scan of the whole object and the other from a limited FOV scan of the ROI. Both of our micro-CT systems have zoom-in micro-tomography capability. One of both is a micro-CT system with a fixed gantry mounted with an x-ray source and a detector. An imaged object is laid on a rotating table between a source and a detector. The other micro-CT system has a rotating gantry with a fixed object table, which makes whole scans without rotating an object. In this paper, we report the results of in vivo small animal study using the developed micro-CTs.

Optical System Design of Compact Head-Up Display(HUD) using Micro Display (마이크로 디스플레이를 이용한 소형 헤드업 디스플레이 광학계 설계)

  • Han, Dong-Jin;Kim, Hyun-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6227-6235
    • /
    • 2015
  • The HUD has recently been downsized due to the development of micro display and LED technology as a see through information display device, gradually expands the application areas. In this paper, using a DLP micro display device designed a compact head-up display(HUD) optical system for biocular observation of the image exhibition area 5 inches. It was analyzed for each design element of the optical system in order to design a compacted HUD. DLP, projection optical system and concave image combiner were discussed the design approach and the characteristics. Through a connection structure analysis of each optical system, detailed design specifications were set up and designed the optical system in detail. Put a folded configuration in the form of a white diffuse reflector between the projection lens and concave image combiner was designed to be independent, respectively. Distance of the projected image is adjustable up to approximately 2m ~ infinity and observation distance is 1m. Resolution could be recognized by 1 ~ 2pixels in HD($1,280{\times}720pixels$) class, various characters and symbols could be read. In addition, color navigation map, daytime video camera and thermal imaging cameras can be displayed.

Single-panel simulation on liquid crystal on silicon

  • Liao, Engle;Chiu, Jack;Peng, James
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.939-942
    • /
    • 2004
  • In this study, we report simulation results of single-panel LCOS (liquid crystal on silicon). Reflective LCOS microdisplays are widely used in various projection and near-eye application. For one panel system, liquid crystal response time is an important variable. The panel must switch fast enough to support the display of Field color sequential with high field rates. In order to have fast response and good contrast, a vertical alignment (VA) cell was used in this study. With suitable selection on LC parameters like temperature, viscosity, elastic constant and birefringence, it is possible to get response time of around 2ms from a 2.0 um-thick vertical alignment cell. This result also indicates an ease of production control on 2.0 um cells than 1.0 um cells.

  • PDF

Micro machining of Polymers Using Photothermal Process (광열반응을 이용한 폴리머의 미세가공기술)

  • 장원석;신보성;김재구;황경현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.616-619
    • /
    • 2003
  • Photochemical and photothermal effects have correlation with each other and depend on laser wavelength. Multi-scanning laser ablation process of polymer with DPSS(Diode Pumped Solid State) 3rd harmonic Nd:YVO$_4$ laser with wavelength of 355nm is applied to fabricate three-dimensional micro shape. The DPSSL photomachining system can rapidly and cheaply fabricate 2D pattern or 3D shape with high efficiency because we only use CAD/CAM software and precision stages instead of complex projection mask. Photomachinability of polymer is highly influenced by laser wavelength and its own chemical structure. So the optical characteristics of polymers for 355nm laser source is investigated by experimentally and theoretically.

  • PDF

Digital Tomosynthesis using a Flat-panel Detector based Micro-CT

  • Mandai, Koushik Kanti;Choi, Jeong-Min;Cho, Min-Hyoung;Lee, Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.5
    • /
    • pp.364-370
    • /
    • 2008
  • Recent development in large area flat-panel x-ray detector technology enables clinical application of digital tomosyntesis. Unlike conventional motion tomography using x-ray films, flat-panel x-ray detectors provide projection images in digital formats so that tomographic images can be synthesized in a more flexible way. For the digital tomosynthesis, precise movements of the x-ray source and the x-ray detector with respect to a fulcrum point are necessary. In this study, we apply the digital tomosynthesis technique to the flat-panel detector based micro-CT in which the flat-panel detector and the x-ray source rotate together on a circular arc. The experimental results suggest that flat-panel detector based 3D CTs can be used for digital tomosynthesis in the clinical environment.

Design of Torsion-typed Smooth Picture Actuator for DLP Projection TV

  • Moon, Yang-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.564-568
    • /
    • 2006
  • Smooth picture module is operated by vibration to tilt the light from the DMD (digital micro mirror device) of DLP projection TV, which makes the screen of the TV smoother and DMD chip cost lower. To satisfy the vibration characteristics of smooth picture module, it is designed by optimizing moment of inertia, spring constant and damping coefficient, using structural and fluid dynamic simulation that showed a good agreement with experimental data. To reduce the material cost and moment of inertia, engineering plastic is used and the reliability is estimated. A VCM (voice coil motor) type actuator for smooth picture has to satisfy performance requirements such as higher driving force, lower power consumption, and lower cost. The initial design and optimization for VCM was performed using FE analysis. It allowed us to optimize the design of magnetic circuit of the proposed actuator to obtain higher force while maintaining a lower cost.

  • PDF

Dynamically Collimated CT Scan and Image Reconstruction of Convex Region-of-Interest (동적 시준을 이용한 CT 촬영과 볼록한 관심영역의 영상재구성)

  • Jin, Seung Oh;Kwon, Oh-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.151-159
    • /
    • 2014
  • Computed tomography (CT) is one of the most widely used medical imaging modality. However, substantial x-ray dose exposed to the human subject during the CT scan is a great concern. Region-of-interest (ROI) CT is considered to be a possible solution for its potential to reduce the x-ray dose to the human subject. In most of ROI-CT scans, the ROI is set to a circular shape whose diameter is often considerably smaller than the full field-of-view (FOV). However, an arbitrarily shaped ROI is very desirable to reduce the x-ray dose more than the circularly shaped ROI can do. We propose a new method to make a non-circular convex-shaped ROI along with the image reconstruction method. To make a ROI with an arbitrary convex shape, dynamic collimations are necessary to minimize the x-ray dose at each angle of view. In addition to the dynamic collimation, we get the ROI projection data with slightly lower sampling rate in the view direction to further reduce the x-ray dose. We reconstruct images from the ROI projection data in the compressed sensing (CS) framework assisted by the exterior projection data acquired from the pilot scan to set the ROI. To validate the proposed method, we used the experimental micro-CT projection data after truncating them to simulate the dynamic collimation. The reconstructed ROI images showed little errors as compared to the images reconstructed from the full-FOV scan data as well as little artifacts inside the ROI. We expect the proposed method can significantly reduce the x-ray dose in CT scans if the dynamic collimation is realized in real CT machines.

A Study on the Usefulness of 3D Imaging in Micro-CT for Observing the Microstructure of Mice (흰쥐 미세구조 관찰을 위한 Micro-CT 3D 영상의 유용성에 관한 연구)

  • Lee, Sang-Ho;Lee, Jong-Seok;Lim, Cheong-Hwan;Jung, Hong-Ryang;Chai, Kyu-Yun;Han, Beom-Hee;Han, Sang-Hyun;Hong, Dong-Hee;Han, Tae-Jong;Park, Sung-Hoon;Mo, Eun-Hee;Jun, Hong-Young
    • Journal of Digital Convergence
    • /
    • v.12 no.3
    • /
    • pp.367-375
    • /
    • 2014
  • In this thesis we observe microvascular structure in mice by using micro-computed tomography (CT), which is high-resolution X-ray imaging equipment that can acquire Real-time dynamic image, and it aims to investigate the usefulness of micro-CT developed by Institute for Radiological Imaging Science Wonkwang University School of Medicine. After acquiring the systemic images of rats, contrast-enhanced 3D images of vascular structures could be acquired by using Maximum Intensity Projection (MIP) and Volume Rending Technique (VRT), This was divided into each vascular system of head, abdomen and heart and systemic vascular system.

A Mathematical Definition of Cognitive Science

  • Hyun, Woo-Sik
    • Proceedings of the Korean Society for Cognitive Science Conference
    • /
    • 2010.05a
    • /
    • pp.2-7
    • /
    • 2010
  • Formally, we may define cognitive science as the convergent study between symbolic and connectionist approaches at macro and micro levels. Since what we refer to as the human mind is regarded as a mathematical product of the human brain and the computing machine, we can obtain two mathematical dynamical projections: one from the set of human brains to the set of mind, the other from the set of computing machines to the set of mind. Then, we are having a new projection from the classical models to the quantum mind.

  • PDF

Study on the Application of Exicimer Laser(1) (엑사이머 레이저 응용 기술에 관한 연구(I))

  • Hwang, Gyeong-Hyeon;Yun, Gyeong-Gu;Lee, Seong-Guk;Kuzmichov, A.V.
    • 연구논문집
    • /
    • s.25
    • /
    • pp.115-120
    • /
    • 1995
  • The aim of this project is the development of technology of production of micro mechanical parts. Materials are Cr, pt or film (thickness $1000-3000\AA$) on glass substrate. Method of manufacturing is resistless direct laser ablation based on the projection technology. A source of radiation is KrF excimer laser(248nm), Experiments of threshold energy are carried out and the results are analyzed by SEM.

  • PDF