• Title/Summary/Keyword: micro-parameters

Search Result 1,108, Processing Time 0.037 seconds

Micro-electrode machining characteristics using the Micro-EDM (마이크로 방전가공기를 이용한 미세전극 가공특성)

  • 안현민;김영태;박성준;이상조
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1003-1007
    • /
    • 2002
  • Micro-EDM is generally used far machining micro 3-D structure. For micro-EDM, first of all, micro-electrode fabrication is needed and WEDG system is proposed for tool electrode fabrication method. When tool electrode is fabricated using WEDG system, its characteristics are under the control of many EDM parameters. Also relations between the parameters affect electrode fabrication. In this study, experiments are carried out to analyze effects of EDM parameters on micro-electrode fabrication. Experimental method and analysis are used to experimental design method. Factors used in experiments are composed of applied voltage, capacitance, wire feed rate, spindle rotating speed, machining time. As a result of experiments, wire feed rate, machining time and capacitance is proportional to gap distance(material removal), the other parameters(applied voltage, spindle rotating speed) and relations between the parameters have little influence on machining.

  • PDF

Free vibration analysis of a three-layered microbeam based on strain gradient theory and three-unknown shear and normal deformation theory

  • Arefi, Mohammad;Zenkour, Ashraf M.
    • Steel and Composite Structures
    • /
    • v.26 no.4
    • /
    • pp.421-437
    • /
    • 2018
  • Free vibration analysis of a three-layered microbeam including an elastic micro-core and two piezo-magnetic face-sheets resting on Pasternak's foundation are studied in this paper. Strain gradient theory is used for size-dependent modeling of microbeam. In addition, three-unknown shear and normal deformations theory is employed for description of displacement field. Hamilton's principle is used for derivation of the governing equations of motion in electro-magneto-mechanical loads. Three micro-length-scale parameters based on strain gradient theory are employed for prediction of vibrational characteristics of structure in micro-scale. The results show that increase of three micro-length-scale parameters leads to significant increase of three natural frequencies especially for increase of second micro-length-scale parameter. This result is according to this fact that stiffness of a micro-scale structure is increased with increase of micro-length-scale parameters.

Probabilistic analysis of micro-film buckling with parametric uncertainty

  • Ying, Zuguang;Wang, Yong;Zhu, Zefei
    • Structural Engineering and Mechanics
    • /
    • v.50 no.5
    • /
    • pp.697-708
    • /
    • 2014
  • The intentional buckling design of micro-films has various potential applications in engineering. The buckling amplitude and critical strain of micro-films are the crucial parameters for the buckling design. In the reported studies, the film parameters were regarded as deterministic. However, the geometrical and physical parameters uncertainty of micro-films due to manufacturing becomes prominent and needs to be considered. In the present paper, the probabilistic nonlinear buckling analysis of micro-films with uncertain parameters is proposed for design accuracy and reliability. The nonlinear differential equation and its asymptotic solution for the buckling micro-film with nominal parameters are firstly established. The mean values, standard deviations and variation coefficients of the buckling amplitude and critical strain are calculated by using the probability densities of uncertain parameters such as the film span length, thickness, elastic modulus and compressive force, to reveal the effects of the film parameter uncertainty on the buckling deformation. The results obtained illustrate the probabilistic relation between buckling deformation and uncertain parameters, and are useful for accurate and reliable buckling design in terms of probability.

A Study on the Dynamic Analysis of Micro-Grid System (Micro-Grid 시스템의 동특성 해석에 관한 기초 연구)

  • Son, Kwang-M.;Lee, Kye-B.;Jeon, In-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.543-544
    • /
    • 2007
  • Micro-grid consists of micro-sources which adopt environmentally friendly and reliable power sources with independent real and reactive power control capability for providing premium power quality. This paper presents dynamic modeling and the stable operating range of the micro-grid system varying the parameters of the micro-sources. Case study results show the parameters affecting the stability of the micro-grid and the stable operating range of the micro-sources.

  • PDF

Experimental study on the surface integrity of electrode for WEDG process (WEDG 전극가공에서의 전극표면형상의 실험적 고찰)

  • 안현민;김영태;박성준;이송규;이상조
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.218-222
    • /
    • 2002
  • Micro-EDM is generally used far machining micro holes, pockets, and 3-D structures. For micro-EDM, first of all, micro-electrode fabrication is needed and WEDC system is proposed for tool electrode fabrication method. When tool electrode is fabricated using WEDG system, its characteristics are under the control of many EDM parameters. Also relations between the parameters affect electrode fabrication. In this study, experiments are carried out to analyze effects of EDM parameters about electrode surface integrity on micro-electrode fabrication. Experimental method and analysis are used to experimental design method. Factors used in experiments are composed of capacitance, resistance, pause time, wire feed rate, spindle rotating speed. As a result of experiments, capacitance and resistance affect electrode surface.

  • PDF

Study on Experimental Selection of Parameters in Laser Scattering Mechanism and Analysis of Laser Scattering Patterns in Solar Cell Wafer (레이저 산란 메커니즘 매개변수의 실험적 선정 및 태양전지 웨이퍼의 레이저산란패턴 분석에 관한 연구)

  • Kim, Gyung-Bum
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.2
    • /
    • pp.7-12
    • /
    • 2011
  • In this paper, a laser scattering mechanism are designed to detect micro defects such as dent, scratch, pinhole, etc. Its influential parameters are experimentally selected and scattering patterns of micro defects have been analyzed for silicon wafer in solar cell. As a result of experiments, scattered lights are rather increased in wafer surface with micro defects, in comparison to no micro ones. Scattering parameters are optimally selected for obtaining robust and high quality laser scattering images of micro defects. It is shown that scattered light components are linearly increased according to the increase of micro defect sizes, and the depth of micro-defects give a large influence on optical deflection.

Analysis on correlation between bone strength by FEA, micro-CT parameters and bone mineral density (유한요소법에 의한 골강도와 micro-CT 지표 및 골밀도간의 상관관계)

  • Yoon, Young-Nam;Lee, Wan;Lee, Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.37 no.1
    • /
    • pp.53-59
    • /
    • 2007
  • Purpose : Bone mineral density (BMD) and bone microarchitecture are important determinants for bone strength. Recently micro-CT have provided possibilities for measuring a variety of structural indices to characterize bone microarchitecture. The objective of this study was to compare the BMD and micro-CT parameters with Young's modulus calculated by finite element analysis (FEA) for the evaluation of bone strength. Materials and Methods Bone specimens were obtained from the 18 female rabbits aged 16 weeks. Of those, 36 samples (right and left femur) were selected for 3D micro-CT analysis $(ANT^{TM},\;SKYSCAN,\;Belgium)$ and BMD by PIXlmus 2 (GE Lunar Co. USA). Five microstructural parameters of micro-CT, such as trabecular thickness (Tb.Th), bone specific surface (BS/BV), percent bone volume (BV/TV), structure model index (SMI) and degree of anisotropy (DOA) were studied. Young's modulus was obtained by software program (ANSYS 9.0, ANSYS Inc, Canonsburg, PA) based on micro-CT three dimensional images. Results : Young's modulus assessed by FEA correlated significantly with Tb.Th, BV/TV, BS/BV and SMI respectively. Young's modulus showed higher correlation with these rnicrostructural parameters of micro-CT than BMD. Microstructural parameters except DOA showed significant correlations within the examined group. Conclusion The microarchitectural parameters o( micro-CT and BMD represented some informations in the evaluation of bone strength assessed by FEA.

  • PDF

A Study on the Stability of Micro-Grid System Considering Operating Range of Micro-Sources (Micro-Source의 운전 범위에 따른 Micro-Grid 시스템 의 안정도에 관한 연구)

  • Son, Kwang M.;Lee, Kye B.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.841-847
    • /
    • 2007
  • This paper deals with the micro-grid consisting of micro-sources which adopt voltage sourced inverters with independent real and reactive power control capability for providing premium power quality. This paper presents dynamic modeling and the stable operating range of the micro-grid system varying the parameters of the micro-sources. The fundamental frequency model of the micro-source inverters are considered to form a dynamic model of the micro-grid system. Stability analysis is performed based on the linearized dynamic model of the micro-grid system. Case study results show the parameters affecting the stability of the micro-grid and the stable operating range of the micro-sources.

Tool Alignment and Machining Accuracy in Micro End Milling (마이크로 머시닝에서의 공구 정렬과 가공정밀도)

  • An, Ju Eun;Lee, Sung Ho;Kwak, Jae Seob
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.2
    • /
    • pp.143-148
    • /
    • 2016
  • A micro end mill is one of the precise tools used in machining ultra-precision products such as microchannel and micropatterned mold. To achieve the required precision of these products, several studies investigated the cutting force, burr formation, and burr generation mechanism of micro end mills; however, there are few studies on the alignment of micro tools, which is the foundation of machining. Hence, in this investigation, relation expressions were derived to determine the relation between the misalignment parameters and the machining accuracy. At the same time, the effect of the machining parameters was analyzed using a multiple linear regression analysis and the analysis of variance. The results indicate that the tilting angle of a micro tool has more influence on the machining accuracy than other parameters.

Study of bony trabecular characteristics using bone morphometry and micro-CT (골형태분석법과 micro-CT를 이용한 골소주 특성에 대한 연구)

  • Song, Young-Han;Lee, Wan;Lee, Chang-Jin;Ji, Jung-Hyun;Lee, Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.37 no.1
    • /
    • pp.27-33
    • /
    • 2007
  • Purpose : The research was done to investigate the effectiveness of 2D bony morphometry and microstructure of micro-computed tomography (micro-CT) on the osteoporotic bony change. We performed the bone morphometric analysis of proximal femur in ovariectomized rabbits with BMD and micro-CT examination. Materials and Methods : Twenty-one female (Newzealand, about 16 weeks old, 2.9-3.4kg) rabbits were used. Three rabbits were sacrificed on the day when experiment began (Baseline). The remaining 18 rabbits were divided into two groups. One group was ovariectomized bilaterally (OVX) and the other animals were subjected to sham operation (Sham). Bone specimens were obtained from the right and left femur of sacrificed rabbits. At intervals of 1, 2, 3, 5, 6 months respectively, BMD tests were performed on the proximal femur by using PIXlmus 2 (GE Lunar Co. USA), 2-dimensional bone morphometric analysis by custome computer program and 2D/3D bone structure analysis by micro-CT (Skyscan 1072, Antwerpen, Belgium). Statistical analysis was carried out for the correlation between bone morphometry, micro-CT and BMD Result : BV/TV, Tb.Th, Tb.N of micro-CT parameters showed higher values in sham group than OVX group. N.Nd/Ar.RI, N.NdNd, N.NdTm, N. TmTm, PmB/Ar.RI, 3-D BoxSlope of 2D morphometric parameters showed higher values in Sham group than OVX group. The micro-CT parameters of Tb.Sp, Tb.N were statistically significant correlated with BMD respectively. Several 2D morphometric parameters were statistically significant correlated with BMD respectively. Conclusion : Several parameters of 2D bony morphometry and micro-CT showed effective aspects on the osteoporotic bony change.

  • PDF