• Title/Summary/Keyword: micro system

Search Result 4,282, Processing Time 0.036 seconds

The Effective in vitro Anti-dandruff Test Method with Resazurin(alarmar Blue$^{TM}$) (Resazurin(alarmar Blue$^{TM}$)을 이용한 효적인 in vitro항비듬력 측정법)

  • 박병덕;흥선영;정세규;조인식;구형서;한일민;이상명;이완규
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.25 no.3
    • /
    • pp.47-66
    • /
    • 1999
  • We have tried to measure the anti-dandruff effect of the several kinds of formulations by determining the MIC values of the P. ovale which was determined by resazurin(alarmar Blue$^{TM}$). To get high reproducibility, it was suggested that about 2.6$\times$10$^{5}$ cfu/$m\ell$ of P ovate should be incubated with alarmar Blue$^{TM}$, optimum dilution ratio between alarmar Blue$^{TM}$ and PBS buffer should be 1:1 -1:4, and optimum incubation time should be 16 ~ 24 hours. Even though 1:1 diluted alarmar Blue$^{TM}$ was incubated with P ovale, the metabolic activity of if ovule was not inhibited by alarmar BlueTM. The Minimum Inhibitory Concentration(MIC) values of several kinds of anti-dandruff formulation which were the mixture system between Zinc pyrithione and Climbazole make it possible to determine the optimal anti-dandruff formulation, which show similar results with that of microscopic MIC determination and that of SDDM(Skin-Disk Diffusion Method). It is expected that the anti-dandruff test method which uses alarmar Blue$^{TM}$ could be used as an effective in vitro test method because it was not so much affected by the turbidity of the broth and samples, and it can afford the MIC values of many samples within relatively short time by using microplate reader.te reader.

  • PDF

Tristetraprolin Overexpression in Gastric Cancer Cells Suppresses PD-L1 Expression and Inhibits Tumor Progression by Enhancing Antitumor Immunity

  • Guo, Jian;Qu, Huiheng;Shan, Ting;Chen, Yigang;Chen, Ye;Xia, Jiazeng
    • Molecules and Cells
    • /
    • v.41 no.7
    • /
    • pp.653-664
    • /
    • 2018
  • The RNA-binding protein tristetraprolin (TTP) binds to adenosine-uridine AU-rich elements in the 3'-untranslated region of messenger RNAs and facilitates rapid degradation of the target mRNAs. Therefore, it regulates the expression of multiple cancer and immunity-associated transcripts. Furthermore, a lack of TTP in cancer cells influences cancer progression and predicts poor survival. Although the functions of TTP on cancer cells have previously been researched, the mechanism of TTP on the interaction between cancer cells with their micro-environment remains undiscovered. In this study, we admed to determine the role of cancer cell TTP during the interaction between tumor and immune cells, specifically regulatory T cells (Tregs). We evaluate the capability of TTP to modulate the antitumor immunity of GC and explored the underlying mechanism. The overexpression of TTP in GC cells dramatically increased peripheral blood mononuclear lymphocyte (PBML) -mediated cytotoxicity against GC cells. Increased cytotoxicity against TTP-overexpressed GC cells by PBMLs was determined by Treg development and infiltration. Surprisingly, we found the stabilization of programmed death-ligand 1 (PD-L1) mRNA was declining while TTP was elevated. The PD-L1 protein level was reduced in TTP-abundant GC cells. PD-L1 gas been found to play a pivotal role in Treg development and functional maintenance in immune system. Taken together, our results suggest the overexpression of TTP in GC cells not only affects cell survival and apoptosis but also increases PBMLs -mediated cytotoxicity against GC cells to decelerate tumor progression. Moreover, we identified PD-L1 as a critical TTP-regulated factor that contributes to inhibiting antitumor immunity.

A Study on the Thermo-Mechanical Stress of MEMS Device Packages (마이크로 머신(MEMS) 소자 패키지의 열응력에 대한 연구)

  • Jeon, U-Seok;Baek, Gyeong-Uk
    • Korean Journal of Materials Research
    • /
    • v.8 no.8
    • /
    • pp.744-750
    • /
    • 1998
  • Unlike common device, MEMS(micro-electro-mechanical system) device consists of very small mechanical structures which determine the performance of the device. Because of its small mechanical structure inside. MEMS device is very sensitive to thermal stress caused by CTE(coefficient of thermal expansion) mismatch between its components. Therefore, its characteristics are affected by material properties. process temperature. and dimensions of each layer such as chip, adhesive and substrate. In this study. we investigated the change of the thermal stress in the chip attached to a substrate. With computer-aided finite element method (FEM), the computer simulation of the thermal stress was conducted on variables such as bonding material, process temperature, bonding layer thickness and die size. The commercial simulation program, ABAQUS ver5.6, was used. Subsequently 3-layer test samples were fabricated, and their degree of bending were measured by 3-D coordinate measuring machine. The experimental results were in good agreement with the simulation results. This study shows that the bonding layer could be the source of stress or act as the buffer layer for stress according to its elastic modulus and CTE. Solder adhesive layer was the source of stress due to its high elastic modulus, therefore high compressive stress was developed in the chip. And the maximum tensile stress was developed in the adhesive layer. On the other hand, polymer adhesive layer with low elastic modulus acted as buffer layer, and resulted in lower compressive stress. The maximum tensile stress was developed in the substrate.

  • PDF

Design of a Low Noise 6-Axis Inertial Sensor IC for Mobile Devices (모바일용 저잡음 6축 관성센서 IC의 설계)

  • Kim, Chang Hyun;Chung, Jong-Moon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.2
    • /
    • pp.397-407
    • /
    • 2015
  • In this paper, we designed 1 chip IC for 3-axis gyroscope and 3-axis accelerometer used for various IoT/M2M mobile devices such as smartphone, wearable device and etc. We especially focused on analysis of gyroscope noise and proposed new architecture for removing various noise generated by gyroscope MEMS and IC. Gyroscope, accelerometer and geo-magnetic sensors are usually used to detect user motion or to estimate moving distance, direction and relative position. It is very important element to designing a low noise IC because very small amount of noise may be accumulated and affect the estimated position or direction. We made a mathematical model of a gyroscope sensor, analyzed the frequency characteristics of MEMS and circuit, designed a low noise, compact and low power 1 chip 6-axis inertial sensor IC including 3-axis gyroscope and 3-axis accelerometer. As a result, designed IC has 0.01dps/${\sqrt{Hz}}$ of gyroscope sensor noise density.

Design of Vertical Type MEMS Probe with Branch Springs (분기된 구조를 갖는 수직형 MEMS 프로브의 설계)

  • Ha, Jung-Rae;Kim, Jong-Min;Kim, Byung-Ki;Lee, June-Sang;Bae, Hyeon-Ju;Kim, Jung-Yup;Lee, Hak-Joo;Nah, Wan-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.7
    • /
    • pp.831-841
    • /
    • 2010
  • The conventional vertical probe has the thin and long signal path that makes transfer characteristic of probe worse because of the S-shaped structure. So we propose the new vertical probe structure that has branch springs in the S-shaped probe. It makes closed loop when the probe mechanically connects to the electrode on a wafer. We fabricated the proposed vertical probe and measured the transfer characteristic and mechanical properties. Compared to the conventional S-shaped vertical probe, the proposed probe has the overdrive that is 1.2 times larger and the contact force that is 2.5 times larger. And we got the improved transfer characteristic by 1.4 dB in $0{\sim}10$ GHz. Also we developed the simulation model of the probe card by using full-wave simulator and the simulation result is correlated with measurement one. As a result of this simulation model, the cantilever probe and PCB have the worst transfer characteristic in the probe card.

Urban Stormwater Runoff Treatment by the RFS (RFS를 이용한 도시유출수처리)

  • Lee, Jun-Ho;Bang, Ki-Woong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.1
    • /
    • pp.159-167
    • /
    • 2000
  • In recent years, combined and separated sewer overflows (CSOs, SSOs) have been recognized as a significant pollution problem. To solve this problem a series of experiments were performed in a small scale Rapid Floc Settler (RFS) device to determine its ability in removing micro particles and dissolved materials from polluted waters. The RFS device is a compact physico-chemical wasterwater treatment system. Polyacrylamide (PAM) is used as a coagulant for treating stormwater in the RFS. The results of Jar test showed that PAM could be an excellent coagulant as compared with aluminum sulfate. and ferric chloride. In several experimental conditions, the influence of different variation parameters was tested to measure the efficiency of the RFS. Tests have been carried out with typical CSOs concentrations (50~1.000mg SS/L). The treatment efficiency with regard to SS and COD, which can be obtained at an overflow rate of $130m^3/m^2/day$, are 90% and 80%, respectively. Comparing other sedimentation technologies with RFS, the overflows rate of RFS is ten times faster. The distribution of particle size and number were analyzed. The RFS is suitable for the treatment of CSOs and also the removal of settleable and dissolved materials in urban stormwater runoff.

  • PDF

Development of Analysis Model for R&D Environment Change in Search of the Weak Signal (Weak Signal 탐색을 위한 연구개발 환경변화 분석모델 개발)

  • Hong, Sung-Wha;Kim, You-Eil;Bae, Kuk-Jin;Park, Young-Wook;Park, Jong-Kyu
    • Journal of Korea Technology Innovation Society
    • /
    • v.12 no.1
    • /
    • pp.189-211
    • /
    • 2009
  • The importance of searching the weak signal has been increasingly recognized to cope with rapidly changing circumstances as an environmental analysis technique. This study proposed the NEST process for the searching for the weak signal. The NEST (New & Emerging Signals of Trends) is a micro environmental analysis process based on both quantitative and qualitative method. For this, the weak signal Searching Board is developed and traditional methods as global monitoring, trend analysis, brainstorming and delphi method are implemented to NEST. The NEST process is consists of three stage modules; the global monitoring stage in search of seeds information related to the environmental change, the weak signal analysis stage using the weak signal Tracking Board, and the delphi valuation stage for objectifying the final result. The NEST provides the weak signal of the promising technology which can bring new paradigm and the Up-Coming Trends which can lead new trend in the future. These outputs can be used to select promising technology from firm level to national level. The NEST system can be effectively operated as well as in small group so that small and medium innovative firms can develop and execute their own NEST process individually.

  • PDF

Comparison of the Gel Formation Ability and Stability of Encapsulated Microbial Inoculant Using Extractable Alginate from Sea Tangle (다시마 추출 Alginate를 이용한 미생물 캡슐화제의 겔 형성능 및 생균력 비교)

  • Choi, So-Young;Yoon, Min-Ho;Whang, Kyung-Sook
    • Applied Biological Chemistry
    • /
    • v.49 no.3
    • /
    • pp.170-174
    • /
    • 2006
  • For the purpose of developing a high quality agricultural microbial inoculant, methods and materials for improving encapsulation were investigated. Preparation of capsule was conducted by improving extrusion system with micro-nozzle and peristaltic pump. The sodium alginate was selected because of its cheapness, stability of cells, and gel formation ability. The yields, physical properties and gel formation abilities of extractable alginate from sea tangle were investigated by hot water extractable and alkali soluble methods. The extraction yields of hot water extractable alginate (HWEA) and alkali soluble alginate (ASA) from sea tangle were 8 and 20%, respectively. The HWEA was almost not viscous even in 1.5% of the sample solution, whereas the ASA was very highly viscous in above 3% sample solution. The gel formation ability of each samples varied from 1.5% to 5% and the ASA showed a good gel formation ability at 3% solution as commercial alginate (CA). The soil microbial inoculant, Bacillus thuringiensis, Bacillus subtilis, Lactobacillus plantarum and Geotrichum candidum encapsulated sodium alginate with starch and zeolite for stabilizer. The survivability of encapsulated soil microbial inoculant using alginate without stabilizer appeared to be 66, 52, 70 and 50%, respectively. Inclusion of starch and zeolite with alginate bead increased viabilities in Bacillus sp. and Geotrichum candidum by 81-83% and 89%, respectively.

Preparation and Release Behavior of Ipriflavone-Loaded PLGA Microsphere for Tissue Engineered Bone (이프리플라본을 함유한 생분해성 PLGA 미립구의 제조 및 조직공학적 골재생을 위한 영향평가)

  • So, Jung-Won;Jang, Ji-Wook;Kim, Soon-Hee;Kim, Geun-Ah;Choi, Jin-Hee;Rhee, John-M.;Son, Young-Suk;Min, Byoung-Hyun;Khang, Gil-Son
    • Polymer(Korea)
    • /
    • v.33 no.1
    • /
    • pp.26-32
    • /
    • 2009
  • The aim of this research was to prepare microparticulate systems based on poly (lactide-co-glycolide)(PLGA) for the local release of ipriflavone in order to reduce bone loss. We developed the IP loaded PLGA microspheres using relatively simple oil-in-water(O/W) solvent evaporation method. HPLC was used to perform the in vitro release test of IP and morphology of cell attached on the micro-spheres was investigated using SEM. Cytotoxicity was assayed by cell counting kit-8 (CCK-8) test. Osteogenic differential cells were analyzed by ALP activity. Through RT-PCR analysis, we observed osteocalcin, ALP, and Type I collagen mRNA expression. The release of IP in vitro was more prolonged over 42 days and IP/PLGA microspheres showed the improvement on the cell proliferation, ALP activity and RT-PCR comparing with control (only PLGA). This initial research will be used to direct future work involved in developing this composite injectable bone tissue engineering system.

Rapid Nutrient Diagnosis of Cucumber by Test Strip and Chlorophyll Meter (Test Strip과 Chlorophyll Meter를 이용한 오이의 신속한 영양진단)

  • Kim, Kwon-Rae;Kim, Kye-Hoon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.36 no.5
    • /
    • pp.272-279
    • /
    • 2003
  • This study was performed to develop a more rapid and simple nutrient diagnosis method of plants than the conventional leaf analysis method. Cucumber (Cucumis sativus L. cv. jangil banbaek) was planted in the mixed media produced by mixing perlite and rock wool at 1:1 (v/v) ratio. The Yamazakki nutrient solution for cucumber was supplied to the media using micro-drip irrigation system. Experimental plots were consisted of no fertilization, deficient fertilization, adequate fertilization, and surplus fertilization for N, P and K. Specific color difference sensor value (SCDSV) measured by chlorophyll meter was closely related to total-N concentration in leaves measured by the conventional method. Nitrate, $PO_4$ and K concentration in petiole sap measured by test strips showed a significant relationship with total-N, P and K concentration in leaves. Linear regression equations between $NO_3$, $PO_4$ and K concentration in petiole sap and total-N, P and K concentration in the leaves were prepared. Optimum levels of $NO_{3}$, $PO_{4}$ and K in petiole sap were obtained by plugging the optimum concentrations of total-N, P and K in the leaves by other researchers into the equations. In conclusion, the SCDSV measured by chlorophyll meter and the concentration of $NO_3$, P and K in petiole sap measured by the test strips would be suitable for rapid estimation of plant nutrient status.